You are on page 1of 13

1 NEW DATA MANAGER 16 BREAK

2 EDIT RELEVANT OBJECTS FOR CALCULATION 17 RESET CALCULATION


3 DATE/TIME OF CALCULATION CASE 18 USER SETTING
4 EDIT TRIGGER 19 MAXIMIZE GRAPHICS WINDOWS
5 DATA VERIFICATION 20 MAXIMIZE OUTPUT WINDOWS
6 CALCULATE LOAD FLOW 21 SELECT TOOLBAR
7 CALCULATE OPTIMAL LOAD FLOW 22 CALCULATE INITIAL CONDITIONS
8 CALCULATE SHORT CIRCUIT 23 START SIMULATIONS
9 EDIT SHORT CIRCUIT 24 STOP SIMULATION
10 EXECUTE DPL SCRIPTS 25 EDIT RESULT VARIABLES: FREQUENCY CHARACTERISTIC
11 OUTPUT CALCULATION ANALYSIS 26 EDIT SIMULATION EVENTS
12 DOCUMENTATION OF DEVICES DATA 27 MODAL ANALYSIS
13 COMPARING OF RESULTS ON/OFF 28 SET EIGENVALUE
14 EDIT COMPARING OF RESULTS 29 SELECT PLOT TYPE
15 UPDATE DATABASE 30 RESULT OF MODAL ANALYSIS
31 PARAMETER IDENTIFICATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

A B C D E F G H I J K L M N O P Q R S T U V W X Y
A freeze mode P cut
B zoom in Q copy
C zoom back R paste
D zoom all S reconnet element
E print T select graphic attributes
F set drawing format U color representation
G rebuild V title block on/off
H insert new graphic W legend block on/off
I insert existing raphic X draw existing net elements
J graphic option Y station feeder option
K show layer
L undo
M mark all elements
N edit and browse data
O delete element
terminal short terminal point terminal rectangular terminal

circular terminal u-terminal polygonal terminal

busbar single bus bar system with tie breaker double busbar system double busbar system with tie breaker

1 1/2 busbar system general busbar system

circuit breaker disconnector load break disconnector load-switch

fuse grounding switch surge arrester

synchronous machine asynchronous machine doubly-fed induction machine external grid

ac voltage source ac voltage source two terminals ac current source

general load low-voltage load

shunt/filter RLC shunt/filter rl shunt filter c shun filter rlcrp

shunt/filter rlccrp static var system

line 2-winding transformer 2-N winding transformer 2-winding transformer

auto transformer series reactor series reactor (x=0) series capacitor

nec/ner common impedance 3-winding transformer booster transformer

rectifier/inverter 2-dc connections rectifier/inverter 1-dc connection pwm converter/2-dc connections pwm converter/1-dc connection

softstarter dc valve inductive coupling dc

dc-voltage source dc-voltage source/2 terminals dc-current source dc-current source/two terminals

dc-dc converter composite branch composite node composite node

You might also like