Professional Documents
Culture Documents
GIKEN (2016) Silent Piling
GIKEN (2016) Silent Piling
&
IMPLANT FOUNDATIONS
2016/11/25
Agenda
6. Case Studies
The Silent Piler
Plant Layout
Sheet Pile
Silent Piler
Principles of the Press-in Method
Press-in Mechanism: Use of Reaction Force
The Penetration Technology
Initial Piling
Noise & Vibration
✔ ×
Noise & Vibration
✔ ×
Noise & Vibration
400 – 750mm
Applicable Piles for Press-in Method
Z Sheet Pile
575 – 708mm
Applicable Piles for Press-in Method
King Post Combi-wall (UB + Sheet)
Applicable Piles for Press-in Method
Tubular Pile
600 –2500mm
Applicable Piles for Press-in Method
Tubular Pile with Interlocks
600 –2000mm
Applicable Piles for Press-in Method
Combi-Gyro Wall (Tube/Z System)
Applicable Piles for Press-in Method
Combi-Gyro Wall (Tube/U System)
Silent Piler Models & Applicable Piles
U Section Z Section Tubular Pile
(width: mm) (width: mm) (diameter: mm)
Silent Piler
575 - 708
Model
400 500 600 750 600 800 1000 1200 1500 2000 2500
Single Pair
F111 ✔
F201 ✔ ✔ ✔
F301-700 * ✔ ✔ ✔
F301-G1000 ✔ ✔ ✔
✔
F401-1400 ✔
**
F401-G1200 ✔ ✔ ✔
F501-G1500 ✔ ✔ ✔ ✔
GRV2540 ✔ ✔
20m
15m
13m
10m
Double Pile
Applicable to;- Augering
Cobbles, Boulders,
Mode
Buried Obstructions,
Rock etc…
Pile Depth
20m
Single Pile
15m
10m
Water Jetting
5m Standard Mode Mode
10 20 30 40 50 500
Max. SPT N Value
Penetration Technologies
Tubular Pile
Applicable to;-
Cobbles, Boulders, Augering Mode
Buried Obstructions, Rock etc… Mode
30m
Pile Depth
20m
10m
Standard
Mode
5m
15 50 500
Max. SPT N Value
Achievable Depth
Steel Tubular Pile φ800mm L=59.5m
Implant Foundations
IMPLANT FOUNDATION
“Embedded Piled Foundation installed into ground
by the Press-in Method”
Implant Foundations
Implant Foundation Durability Resiliency Footprint
Gravity Foundation
6.0E+06
Diaphragm Wall
Wall Bending Stiffness EI (kNm2/m)
5.0E+06
Combi-Gyro Wall
2.0E+06
Contiguous Wall
1.0E+06
90
Secant Pile Wall
Combi-Gyro
80 Wall
Cost Index (%)
70
60
Contiguous Wall
50
40
30
0 1,000 2,000 3,000 4,000 5,000 6,000
10.7m
Cantilevered
Wall
φ914mm Tubes
New York
Long Island Express & Cross Island Parkway
Road Retaining Wall
Implant Retaining Wall (Cantilevered)
Implant Retaining Wall (Cantilevered)
Residential Property
Erith
(R/H=7.0m)
Implant Retaining Wall (Anchored)
London
M25 Junction 12 Improvement
Road Retaining Wall
Retaining Wall Cladded with Bricks
National Road A2, LONDON
Φ914mm Tubes
Crossrail Project, London
Implant Cofferdam
Geotextile
Completed Project
Implant Basement Wall
St David’s 2, CARDIFF
Implant Basement Wall
St David’s 2, CARDIFF
Shear Connectors
Implant Basement Wall
Slab Connection Details
Shear Stud
Water Bar
Plate
Shear Stud
Implant Basement Wall
Slab Connection Details
Shear Studs
Hydrophilic Strip
(Water Swelling Material)
Completion
Completion
Singer Island, FLORIDA
Implant Flood Defense Wall
Post Installation
Implant Flood Defense Wall
Completion
Difficult Conditions (Above Water)
Improvement of Port & Harbor
Batangas, Philippines
General Cargo Berth Construction Works
Completion
Difficult Conditions (Above Water)
Cofferdam Installation above Water
After De-watering
10m
Difficult Conditions (At Height)
www.giken.com/en
88