3. Outline of ESB
Emergency Generator
Source of electric power:
Aux. Generators
Battery
Emergency Generator
Main Elements of Distribution
System
Main Switch Board (MSB)
Emergency Switch Board (ESB)
Auxiliary Switchboard
Engine Control Console
Group Starter Panel
Individual Starter (Steering gear)
Invertor Panel
(Starter for Deck Machinery)
2. Outline of MSB
Structure of MSB
Skeleton of Power Supply & Distribution
Bas Bar Isolation Method
Protection of Generator
Protection of Feeder Circuit
Protection of Transformer
Auto starting of Stand-by DG
Preferential trip
Precaution of frequent tripping of MCCB due to
overcurrent. MCCB braking capacity Icu / Ics
(Module 12a)
Outline of MAIN SWITCHBOARD
Watching status of 5
generator and feeder circuit
Structure of MSB
Skeleton of power supply &
distribution
Skeleton of power supply and
Generated power is concentrated
distribution on the 440V main busbar
Concentrated power is divided
Feeder bus-2 Feeder bus-2 440V main busbar
440V main busbar Feeder bus-1 Feeder bus-1 into two feeder busbars (left and
right) and subdivided by MCCB for
100V busbar 100V busbar
feeders in feeder panel..
2* 1*
MCCB MCCB MCCB MCCB
MCCB MCCB MCCB ACBMCCBACB ACB ACB ACB MCCBACBMCCB MCCB MCCB *ACB; Receiving power generated
by generator and
protection of the generator.
External View of a
Disconnecting Switch.
Disconnecting Switch
Confirm No Volt on Bus Bar
Disconnecting the Bus Bar using
special tool
Bus Bar Disconnected by DS Type
Special tools for Bus Bar Disconnection
ACB as Disconnecting Switch
(Could be manually tripped under
load condition)
Protection of Generator
MAINMAIN
BUS BUS
ACB (ARTYPE)
ACB (AR TYPE)
GG
OVER CURRENT
OVER CURRENT
RELEASE DEVICE
RELEASE DEVICE
"AGR-21S-PRU"
"AGR-21S-PRU"
DIESEL
DIESEL
ENGINE
ENGINE
PROTECTION
PROTECTION ELEMENTS
ELEMENTS
1, OVER SPEED
1, OVER SPEED
2, L O2,LOW
L O LOW PRESSURE
PRESSURE
3, C F3,WC HIGH
F W HIGH TEMP
TEMP
Protection of Feeder circuit
* Over current protection and Short circuit protection for a feeder circuit generally depends
on the molded case circuit breaker which is called MCCB.
* Breaking capacity of MCCB must be greater than the prospected short circuit current
at a point where the MCCB is installed.
* There are two protection systems. One is selective tripping and another one is Back up
protection
440V
Feeder bus
MCCB for
Transformer
To 100V
CT Transformer Feeder
SHT
Following feeder must be equipped in Emergency Switchboards and the power must be
recovered within 45secs when blackout occurs.
EG EG engine
control panel
EMERGENCY GENE. (M/S)
Circuit Diagram
of #1 Gen Panel
EC-01 p.61
Please open file EC-01
Верху справа - номер колодки (TB1), где она находится можно
посмотреть на стр 60.
DRAW NO - показывает номер чертежа с которого выходят
концы
WIRE MARK - маркировка внутреннего провода на колодке
TERM NO - номер клеммы на которой "сидит" конец
PREFERENCE NO - маркировка внешнего провода