SS & Feeder Management
SS & Feeder Management
Power TransformersGenerally 33/11 KV Capacity (MVA)1.6, 3.15, 5, 8 Location- Ideally, Power transformers should be located at places with the following factors into considerationLine Loss in 33 KV Feeders is Minimum Line Loss in 11 KV Feeders is Minimum Power Supply Quality (Voltage) is maintained
33/11 KV
(KVA)-
Ideally, DTRs should be located at places with the following factors into considerationLine Loss in 11 KV Feeders is Minimum Line Loss in LT Line is Minimum Power Supply Quality (Voltage) is maintained
can be optimized by way of proper Feeder and Substation Management In case of high loss making feeders the priority may be given in load shedding while handling power shortage Reorientation of feeders, substations and upgradation can further help improving revenues Installation of proper capacity of capacitors In ABT(Availability Base Tariff) regime, by managing feeder/ substation load, revenue can be improved
Applications
Providing GSM/GPRS/CDMA/Radio based communication solutions to the utility industry end users and OEM's to benefit from this technology in their electrical networks, SCADA systems and for metering.
DATA EXPLOITATION
Energy Management Software which can read meters in a sub-station and provide various reports Energy Monitoring Suite which provides, reporting, trending, trading, analysis, etc. Energy Trading and Enterprise Optimization Software Solutions Integration Capabilities to work tools like Cyme etc., for network modlling, voltage studies, etc., Customized Solutions based on customers specification
WORK PLAN
ENERGY
33 KV Feeders in a Distribution System This is the level of Voltage at which Discoms buy Power from GRIDCO Mixed Load 33 KV Feeders Dedicated Feeder Industrial Feeder For Carrying out Energy Accounting & Audit, Metering of 33 KV Feeders at the Grid Substation, at incoming side of 33/11 KV Substations and all 33 KV Consumers is a must.
11 KV Feeders in a Distribution System 11 KV Feeders emanate from 33/11 KV Power Substations Mixed Load 11 KV Feeders Dedicated Feeder Industrial Feeder
For Carrying out Energy Accounting & Audit, Metering of 11 KV Feeders at the source of 11 KV Feeders at 33/11 KV Substation and at all the DTRs and 11 KV Consumers is a must.
LT Lines in a Distribution System LT Lines emanate from 11/0.4 KV Distribution Substations For Carrying out Energy Accounting & Audit of LT Lines, Metering at the source of LT Line and Consumers is a must.
on Improvement in Billing
By Reduction of Theft in HT Consumers Strengthening MRT, Conducting Raids, Repeated Checking, Strict action against Dishonest Consumers. By Reduction of Theft in LT Consumers By Strengthening Vigilance Wing, Conducting raids, Load Surveys, Strict action against Dishonest Consumers By Monitoring of Spot Billing activities
Focus
By Reduction of Line Losses in 33 KV &11 KV Feeders and LT Lines Reduction of Transformer Losses in 33/11 KV Trfs and in DTRs.
Need to be tagged to LT Lines, DTRs, 11 KV Lines, 33/11 KV Substations, 33 KV Lines and Input Points.
WAY FORWARD
Commitment of top leadership Organisational Restructuring Clear responsibilities and accountability
Feeder Managers
SUSTAINABILITY
Linking
the Energy Audit Module with Billing Databases for continuous monitoring Maintaining the data quality Prepare an operational model Consistency of systems for access and extract data from any sources