You are on page 1of 10

Ethical Review

• Health and Environment Safety


Provide a safe, healthy, and clean working environment

- Human Rights and Labor Standards


Respect human being
Secure human rights and dignity of people
Non-discrimination

- Anti-Corruption
Employees must ensure that the company’s interests are never compromised

Should not offer or make illegal payments


Company will cooperate with governmental authorities to eliminate corruption
• Conflict of interest
Employees must act in the interest of the company
Ensure that any personal association does involve a conflict of interest
with the company’s operations

- Quality of products and services


Supply products of world-class quality
Products shall meet applicable national and international standards
Utilities and Waste treatment

• Flue Gas Treatment


- Hydrogen Purifier used for capturing hydrogen from flue gas emitted
- Fluid- Bed Adsorbers are installed (Zeolites as adsorbent)

Copyright: Health and Environmental impacts Division


Recommendations and Future Work

-Carbon capture, utilization, and storage (CCUS)


Carbon Dioxide will be separated, treated, and transported to storage
location
-Since it is a costly process, will be part of the future plan
Safety
• Nodes
HAZAN

Part ID Hazard Cause O C R Recommended Revised


Description Control Risk

            - Incorporate TIC  
            where cooling  
Reactor Rupture of High pressure C 3 3C fluid in the jacket  
(R-101) reactor vessel and temperature       maintains the 3D
in tank temperature of
(exothermic the reactor
runaway)  
- Incorporate
pressure relief
valves

             
  -Thermal       -Regular  
  expansion of       inspection of  
  fluid due to sun       pressure control  
Storage exposure or       valves  
Tank external heat          
(E-106) source          
        - Pressure gauge  
-Inadequate       readings should  
  ventilation due D 2 2D be recorded 3D
  to pressure relief   regularly
Explosion valve failure  
  -Safety showers
-Automated are designed to
pressure control pour water on
system personnel in
malfunction case of fire
               
          - proper  
 
 
 
 
•    
 
 
 
 
 
ventilation
-minimizing
 
 
 
 
 
  •    
 
 
 
 
 
potential
ignition sources
 
 
  Methanol          
    getting in •         -Installing fire  
    contact with D 2 2D detection and 3D
Vaporizer Explosions • Vaporizer
sparks, hot (E-101) suppression
(E-101) surfaces, or systems
open flames  
- Safety Showers
are designed to
pour water on
personnel in
case of fire

               
            Incorporate FIC  
  Flooding of the Reboiler duty is C 3 3C to control the 3D
  column above set point steam flow to
Distillation the reboiler,
Column decreasing it
(E-103)

               
               
    -Non       - installation of  
  Release of installation of       carbon Review
Absorber hazardous gas gas D 4 4D absorbers not
(E-102) to atmosphere Capturers maintenance of required
  gas absorption
  system
-Failure of flue
gas capturing
system
 
HAZOP