Data Configuration
Note: The only difference between the two configuration modes is the
process that the configuration data takes effect
LMT GBAM
Loading
Level Authority
Guests Guests can only view the data.
Users In addition to the authority of guests, users can also perform
system maintenance, such as equipment maintenance, alarm
management, and performance management.
Operators In addition to the authority of users, operators can also perform
data configuration on the equipment.
Administrators Administrators have the root authority. In addition to the
authority of operators, administrators can also perform user
management.
Custom The custom authority is defined by administrators.
One GDPUC board can handle 968 voice channel, GDPUC board take N+1
configuration mode, all TC resource is shared in resource pool mode
In fact, all the boards can be configured in all slots except GTNU and
GSCU, but considering engineering, LMT give us a standardization
configuration:
GSCU fixed to occupy slot 6 and 7 in GMPS/GEPS/GTCS frame
GTNU fixed to occupy slot 4 and 5 in GMPS/GEPS/GTCS frame
GGCU fixed to occupy slot 12 and 13 in GMPS frame
GXPUM fixed to occupy slot 0 and 1 in GMPS/GEPS frame
GXPUC fixed to occupy slot 8 and 9 in GMPS/GEPS frame
GDPUC fixed to occupy slot 0 ~ 3,8 ~ 13 in GTCS frame
Choose Start > Programs > HUAWEI Local Maintenance Terminal >
BSC6000V900R001Cxx > BSC6000 Local Maintenance Terminal to
start the BSC6000 Local Maintenance Terminal :
After the BSC properties are configured, they take effect in the entire
BSC. Do not modify these properties unless necessary.
network planning.
Remarks
After the BSC information is configured, do not modify it
unless necessary.
After the BSC properties are configured, they take effect in the entire
BSC. Do not modify these properties unless necessary.
For a remote subrack, the line clock extracted form the A interface
serves as the reference clock.
For a local subrack, the line clock extracted form the A interface
serves as the reference clock or system clock
Add a cabinet
Add a board
The cabinet where the power distribution box is located has at least one
subrack configured
The subrack that controls the power distribution box is already configured
The GGCU, GTNU, and GSCU can be deleted only when their
subracks are deleted
The boards in the GMPS, GEPS, and GTCS are configured in
sequence
The GMPS or GEPS requires at least two GXPUMs, two GEIUBs or
two GOIUBs, and two GEIUTs or two /GOIUTs
The GTCS must be configured with at least two GDPUCs, two GEIUTs
or two GOIUTs, and two GEIUAs or two GOIUAs
Each GXPUM and GXPUC has four CPUs, ranging from 0 to 3. Each
of the other boards has only one CPU
Each GDPUC has 22 DSPs, ranging from 0 to 21.
Each GEIUB, GEIUP, GEIUP, or GEIUA has 32 ports, ranging from 0
to 31
Adding a BTS
Configuring the basic attributes of a BTS
Adding or deleting BTS boards and modifying the attributes of BTS
boards
Adding or deleting slave chains of a BTS
Moving a BTS
The number of cells under a BTS cannot exceed 12. A cell supports a
maximum of 24 TRXs
The maximum number of TRXs that a BTS supports varies with the BTS
type
The number of BTS levels cannot exceed seven
The active TMU boards and the TRX boards cannot be added in this
operation
You cannot delete active TMU boards or TRX boards in this operation
Add a cell
Modify the attributes of cells, TRXs, and channels
Modify cell adjacent relations
To add a cell
If the added cell has adjacent cells, modify the cell handover
parameters to configure the cell adjacent relationship after adding
the cell
Adding TRXs may cause the lack of timeslots and the need of
adding subracks and boards
In the Back up data of GBAM dialog box, select a file, and then
select Obtain file from GBAM
To check whether the data of a board in the LMT and that in the
GBAM is consistent
Ensure that the extensions of the result files are .xml