You are on page 1of 7

Daily Pick Up Error Countermeasure Study Report

Target
0.08%

Date Shift Line Model M/C Table Feeder Type Part No Count Error PPM %

01-08-23 1st 18

Root Cause PIC

No data LNB error start 05.00 ~ 11.40 am


Daily Pick Up Error Countermeasure Study Report
Action Before After
Change hard disk & restore LNB backup.
Start run 11.45 am

Result
Count
Error
Percentage %

Trend Graphic
Daily Pick Up Error Countermeasure Study Report
Target
0.08%

Date Shift Line Model M/C Table Feeder Type Part No Count Error PPM %

01-08-23 2nd 18

Root Cause PIC

No data LNB error start 05.00 ~ 11.40 am


Daily Pick Up Error Countermeasure Study Report
Action Before After
Change hard disk & restore LNB backup.
Start run 11.45 am

Result
Count
Error
Percentage %

Trend Graphic
Daily Pick Up Error Countermeasure Study Report
Target
0.08%

Date Shift Line Model M/C Table Feeder Type Part No Count Error PPM %

Tray no
01-08-23 3RD 19 BHB 56801 V2.2 7 14 module TB0227CS1102 16 3 2712 18.75
5

Root Cause PIC

Part Condition In Pallet ( Tray ) Component Module Mansur


Cause Error Not Pickup In Pallet
Daily Pick Up Error Countermeasure Study Report
Action Before After
Check Pallet Condition Module & Check
Pickup Position

NB : Line Running 2nd Close Po 3rd Not Running


Image Image
Result
Count
Error
Percentage %

Trend Graphic
Daily Pick Up Error Countermeasure Study Report

Top 1 Causal Factor Analysis

Shift M/C Table Feeder Part No Count Error PPM % Causal Factor
1st

2nd

3rd 3 1 6L 24228000020 9024 4 275 0.08

Causal Factor

Unstable Pick Up Index Image Recognition Error Pickup Pressure