boiler efficiency increased by about 1%. TYPE OF APH
RECUPERATIVE TYPE- Heat exchangers
without storage. Example: Tubular type & Plate type
REGENERATIVE TYPE-Heat exchangers with
storage Example: Ljunstrom APH ADVANTAGE OF REGENERATIVE APH • COMPACT IN SIZE
• HIGH SURFACE AREA TO WEIGHT
RATIO
• EASY & ECONOMIC REPLACEMENT OF
HEATING ELEMENTS SOME SALIENT COMPONENTS OF REGENERATIVE APH HEATING ELEMENTS SEALING SYSTEM DRIVE MECHANISIM SUPPORT & GUIDE BEARING WITH LUBRICATION SYSTEM FIRE SENSING ELEMENTS DRIVE MECHANISM
• MAIN DRIVE IS ELECTRIC MOTOR
WITH H/C, SPEED REDUCER GEARBOX & RACK-PIN ARRENGEMENT.
• EMERGENCY DRIVE IS AIR MOTOR
SUPPORT & GUIDE BEARINGS • SUPPORT BEARING IS SPHERICAL ROLLER THRUST BEARING, LOCATED AT BOTTOM • GUIDE BEARING IS SHERICAL ROLLER BEARING, LOCATED AT TOP • BOTH SUPPORT & GUIDE BEARINGS ARE PROVIDED WITH INDEPENDENT OIL CIRCULATION SYSTEM. FIRE SENSING ELEMENTS • DURING START-UP DUE TO POOR COMBUSTION UNBURNT OR PARTIALLY UNBURNT OIL CONDENSING AND DEPOSITING ON HEATING ELEMENT SURFACE • AS THE GAS TEMPERATURE ENTERING APH INCREASES,THE DEPOSIT FORMED TO A HARD VARNISH-LIKE MATERIAL THAT CAN IGNITE IN THE RANGE OF 315 TO 370 DEG FIRE SENSING ELEMENT MOST OF THE HEAT GENERATED DUE TO IGNITION IS ABSORBED BY THE METAL OF HEAT TRANSFER ELEMENT NEARBY & IT IS VERY ESSENTIAL TO DETECT IT AT THIS STAGE. IF THIS REMAIN UNDETECTED IT WILL CONTINUE TO GENERATE HEAT UNTILL THE METAL OF HEAT TRANSFER ELEMENT REACHES 730 TO 765 DEG & AT THIS STAGE METAL MAY IGNITE WITH TEMPERATURE OF 1650 OR HIGHER. FIRE SENSING ELEMENT
• TO DETECT THIS AT EARLY STAGE
THERMOCOUPLES STRATEGICALLY LOCATED IN HOT & COLD END WHICH CONTINIOUSLY MONITOR ANY ABNORMAL INCREASE IN TEMPERATURE OF LEAVING AIR & GAS FROM APH, WILL GENERATE APH FIRE. Increase in leakage Increased fan power consumption Higher leakage increases gas volume, so a higher velocity, affects ESP performance in a major way. Lowers measured exit gas temperatures and unless corrected, gives erroneous boiler efficiency values Eats up fan margins, at times limiting the unit output GAS & AIR SIDE PR. DROP