MAIN SYSTEM START UP


49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

1.- All controls in the operator's console


must be set to "OFF" or "Neutral"

Access Stairs: Neutral


Protective Cover for Window: Neutral Water Injection: Neutral
Adjusting the fan: Neutral
Tool Wrench: Neutral
Bar Holders: Neutral

Switch – Hoist/Pulldown Speed: Neutral


Hoist/Pulldown Rheostat : Neutral
Gate Drill Bits Display: Neutral

Hoist Brake: Neutral

Propulsion Selector: Neutral

Operation Selector: Neutral

Main Compressor: Neutral Automatic leveling: Neutral

Environmental controller: Neutral Switch Mastil/Winche: Neutral

Mast Support Safe: Neutral Switch – Rotary Speed: Neutral

Mast Safe: Neutral Rotary Rheostat: Neutral

2 Bit Wrench: Neutral


49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

2.- All emergency stop buttons


must be in raised position.

Emergency Stop: UP Emergency Stop: UP

3
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

3.- Starting in the cabinet located in the machine


room, the main switch of the compressor must
be "ON". Main Compressor
ACD/ACC/ACO
ON

4
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

4.- All MCC breakers have to be ON

480VAC
Aux Power.
MAB/GFR/PSR/GFT
ON

5
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

Fan Filter
PFB/PFCF/
PFCR/PFO
ON

Take Dust Fan Filter Motor


PFBB/PFBC/PFBO
ON

Rotary Blower
RMBB/RMBC/RBP
ON

Hoisting / Push Blower Drill Bit


Rotary
HPMBB/HPMBC/HBO
ON
Oil Cooler
OCB/OCCC/OCO
ON

6
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

Compressor
fan radiator
RFB/RFC/RFO
ON

7
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

Air Conditioner
OCAB
ON

Lighting transformer
LCTB
ON

Cable Reel Motor


CRCB/CRC/CRO
ON

Welding #1
ON

Welding #2
ON

8
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

5.- The programmable controller cabinet make sure the control button closing
is in the release position. Set the fan switch in the room pressurization
machine in the desired operating position.
Verify that the switches of the power supply terminal operator display, input and output PLC

, are in the "ON".

Stop Control Supply Switches,


button Monitor Pantalla,
UP PLC input switch,
Pressurization Fan
PLC Output Switch
Switch
ON
Auto

9
49HR_Drill/M2/T07/

2.7. MAIN SYSTEM START UP

6.- Press the starter button on the air compressor in the controller cabinet
programmable to start the main compressor.

Air Compressor
Starter Button
Press