You are on page 1of 20

‫‪Api 570‬‬

‫‪In service Piping Inspection Code‬‬

‫الفصل األول راح نعرف التالي ‪:‬‬


‫‪ api570 -1‬يحتوي على شنو وشنو الغرض منة ؟‬
‫‪ api 570 -1‬يشتغل على يا نوع من االنابيب ؟‬
‫‪ – 2‬على يا نوع من الفلود ؟‬
‫‪ – 3‬شوكت منكدر انطبق ال ‪api 570‬‬
‫‪-4‬‬
What api 570 cover ?
‫شنو الموجود بهذا الكود ؟‬

2. Repair + alteration

1. INSPECTION 3. Rating
What api 570 cover ?
‫شنو الموجود بهذا الكود ؟‬

1. inspection
2. Repair + Alteration
3. Rating

01 02 03
metallic piping pressure
fiber-reinforced plastic FRP
relief
Glass reinforced plastic GRP
valve
Api 570 for in-service piping

Not for new


construction of
piping
Inservice-piping

New Construction
‫هذا الكود مخصص الي نوع من الفلود‬
For hydrocarbon & checmical fluids
Api 570 only for the following piping

1- Metallic piping
2- fiber-reinforced plastic FRP
FRP/GRP 玻璃纤维

Glass reinforced plastic GRP

Api 570 applicable only for


1- metallic piping
2- GRP / FRP piping
Their pressure relief valve
FRP/GRP 玻璃纤维
Api 570 NOT used for :
PE Polyethelene
FRP/GRP 玻璃纤维
Api 570 NOT used for :

PP polypropylene
FRP/GRP 玻璃纤维
Api 570 NOT used for :

PS Polysewer
FRP/GRP 玻璃纤维
Api 570 NOT used for :

ABS acrylonitrile
butadiene styrene
Api 570 doesn’t
cover
1. Instrumentation tubes
2. exchanger tubes
3. control valves
4. retired piping
5. Piping abandoned in place
Process piping systems that are
temporarily out of service but
have been mothballed
(preserved for potential future
use)

are still covered by Api 570


Api Intent of this code
Insure on-going integrity of piping systems

570 ‫هدف الكود ايحدد الفحوصات لالنابيب الداخلة في الخدمة‬


‫وطرق مراقبتها‬
Api Shall not be used :
570 1- as a substitute for the original construction
requirements
2- in conflict with any prevailing regulatory
requirements .
Api 570 used for the following
Type of fluid
raw, intermediate, and finished petroleum and chemical products
catalyst lines
hydrogen, natural gas, fuel gas, and flare systems

sour water and hazardous waste streams


hazardous fluid services;

cryogenic fluids such as: liquid N2, H2, O2, and air

high-pressure gases greater than 150 psig such as: gaseous He, H2,
O2, and N2
API 570 optional for :

• hazardous fluid services below designated threshold limits, as


defined by jurisdictional regulations
• water
• Steam
• steam-condensate
• boiler feed water
• and Category D fluid
• fire protection systems
Fittness for service
evaluating in-service damage for piping
Risk-Based
Inspection (RBI)
Can be used for determining inspection interval .

Api 580 for risk-based inspection (RBI) program