Cleaning
&
Cleaning Verification
INTERGASTRA
Committed To Serve
Centers for Disease Control (CDC), USA, 2008
Cleaning is the removal of visible soil (e.g., organic and inorganic material)
from objects and surfaces and normally is accomplished manually or
mechanically using water with detergents or enzymatic products. Thorough
cleaning is essential before high-level disinfection and sterilization because
inorganic and organic materials that remain on the surfaces of instruments
interfere with the effectiveness of these processes. Decontamination removes
pathogenic microorganisms from objects so they are safe to handle, use, or
discard.
Cleaning of every material that is used in the hospital should be carried out
prior to the disinfection or sterilization process…
Hal ini bukanlah dekontaminasi dan tidak menghilangkan kemungkinan transmisi kuman
kepada pekerja, oleh karena itu pekerja harus selalu menggunakan alat pelindung diri
dan mengikuti standard K3 yang sudah ditentukan.
b. Setelah alat diterima di lokasi pencucian maka perlu dilakukan disassembly. Bagian-
bagian yang dapat dilepas harus dilepas, ikuti petunjuk dari pabrikan instrument. Hal ini
bertujuan untuk memberi akses bagi katalis pembersihan, disinfektant ataupun sterilant
ke permukaan instrument.
c. Pisahkan alat dan klasifikasikan group alat yang memerlukan proses yang sama.
Pisahkan alat yang tajam untuk menghindari kecelakaan kerja. Pisahkan alat yang
mudah rusak untuk menghindari resiko kerusakan.
INTERGASTRA
Committed To Serve
Pre-Cleaning:
d. Rendam alat dalam cairan yang sudah diperbolehkan. Jangan rendam dalam air
garam, gunakan deterjen atau enzymatic deterjen yang sesuai untuk instrument, hindari
perendaman terlalu lama (i.e. satu malam).
INTERGASTRA
Committed To Serve
Cleaning:
Pencucian dapat dilakukan secara manual atau secara otomatis.
Pencucian dengan musuh dapat mengurangi resiko operator ter-ekspos pada darah dan
cairan tubuh, pencucian manual diperlukan untuk instrument yg rumit dan rapuh.
Ikutin aturan dari pabrikan instrument termasuk deterjen yang harus digunakan, suhu
air dan metode pembersihan.
a.Rendam alat alat yang memungkinkan seluruhnya ke dalam air, apabila ada bagian
yang tidak bisa direndam seluruhnya, minimalkan terjadinya aerosol. Gunakan
sikat dan lap untuk membersihkan kontaminan.
f. Periksa alat-alat pencucian, periksa sikat dan lainnya apabila terjadi kerusakan, harap
diganti. Bersihkan, disinfeksi dan keringkan alat alat bantu pencucian seperti sikat, lap
dan lainnya sebelum disimpan.
INTERGASTRA
Committed To Serve
Cleaning:
d. pembilasan, bilas instrument secara menyeluruh, deterjen yang tersisa dapat bereaksi
dengan disinfectant/sterilant. Bilas instrument berlumen dengan air bebas kontaminan.
d.Kemas instrument yang perlu di sterilkan kecuali untuk flash sterilisasi. Pengemasan
yang dipergunakan harus mengakomodasi proses vakum dan penetrasi uap.
e.Proses cleaning perlu di audit secara rutin, perbaikan perlu dilakukan sesuai dengan
hasil audit
INTERGASTRA
Committed To Serve
ACTION CONCENTRATION
TIME TEMPERATURE
Water Quality
INTERGASTRA Hard Water
Air Sadah
Committed To Serve
Calcium Carbonate
Water Ca2+ Sulphate
SO42- CO32- Magnesium
H2O Mg2+ Iron
Fe2+
Fluorine Copper
F- Aluminum Cu2+ Sodium
Potassium Al3+ Na+
K+
Hydroxide
OH-
Bicarbonate Phosphate Zinc
HCO3- Silicates PO43- Zn2+
Nitrate Chlorine
NO3- SiO2
Cl-
Water Quality
INTERGASTRA Hard Water
Air Sadah
Committed To Serve
Water Quality
INTERGASTRA Ion Metal
Committed To Serve
Committed To Serve
Water Quality
INTERGASTRA Ph
Committed To Serve
Committed To Serve
Water Quality
INTERGASTRA Silica
Committed To Serve
Committed To Serve
Water Quality
INTERGASTRA Anion Korosif
Committed To Serve
Committed To Serve
Water Quality
INTERGASTRA Air Murni
Committed To Serve
Organic Inorganic
•Come from living organisms i.e. fat, grease, •Come from the Earth i.e. hard water deposits,
blood, mucous & microorganisms residues from cleaners, skin preps & medical
solutions
•Acidic in nature, pH 0 - 6
•Alkaline in nature pH 8 - 14
•Best removed using alkaline detergents
•Best removed using acidic detergents
INTERGASTRA
Committed To Serve
Selection of Detergent
a.Ikuti aturan pabrikan untuk tipe kontaminan sebaiknya menggunakan deterjen apa
yang efektik.
2.Deterjen alkali
Biasanya berbahan dasar sodium hydrozie (NaOH) atau potassium hydroxide
(KOH)
Efektif di suhu > 50°C
Ph basa dari 9 -12
Apabila terlalu basa masa membutuhkan netralisasi
3.Neutralizer
Ph asam < 7
Biasa digunakan sebagai netralisasi
Dapat dipergunakan untuk menghilangkan karat dan bercak
4. Rinse aid
Ph netral atau sedikit asam
Berisikan surfaktant, membantu proses pengeringan dan mencegah bercak
The Importance of Cleaning!
Page 37
• The Importance of Cleaning!
• Ensure better contact between the disinfectant and sterilant with any
remaining infectious microorganisms!
Page 38
Reasons for Manual Cleaning
• Lack of mechanical equipment
Reasons for Manual Cleaning
• Instrument design and manufacturers recommendations
– Essential for department cleaning protocols
Reasons for Manual Cleaning
• Amount of soil and condition of soil on the instrument
– Poor protocol at the point of use
– Instruments that have been allowed to dry
Reasons for Manual Cleaning
• National and local standards of practice
– Prerequisite to mechanical cleaning
Action
Water Flow, impingement
and Brushing
44
Time
Process Time
• Detergent manufacturers’
recommendations
Inside joint of
instrument
Teeth
49
of instrument
INTERGASTRA
Committed To Serve
Cleaning Verification
2. Protein Test
INTERGASTRA
Committed To Serve
Cleaning Verification
3. Cleaning Indicator
INTERGASTRA
Committed To Serve
Cleaning Verification
3. Cleaning Indicator
INTERGASTRA
Committed To Serve
PT INTERGASTRA nusantara
Jl. Pangeran Jayakarta 24/35
Jakarta 10730
Indonesia
Phone : +62-21-6493880, 6397096, 6397402
Fax : +62-21-6298649
Email : info@intergastra.co.id