CATENARY STAGGER
+200 OR
0 OR
-200 OR
-400
DISPLACEMENT
OF PANTO
CONTACT WIRE
STAGGER
PANTO AXIS
CL OF TRACK
FIG. 3.3.1
UN-INSULATED
OVERLAPS
At un-insulated overlaps, the stagger should conform to
Drg. No. RE/33/G/02121 sheet 1. On non uniform
curves or at other locations where staggers different from
those indicated in these drawings are adopted, the
following points should be observed.
ii) In any span at the centre of which only one of the contact
wires is in-running (as in a 4-span overlap), the mid-span
stagger of the in-running contact wire does not exceed the
values given in Drg.No. ETI/OHE/ G/00202.
iii) The two contact wires run parallel to each other between
the intermediate supports at a distance of 200 mm from
each other.
Phase II - Module No. STC-TrD-2
CAMTECH, Gwalior
INSULATED OVERLAPS
NEUTRAL SECTIONS