You are on page 1of 9

M O N T H L Y Q U A L I T Y R E V I E W D E C K

Repair Supplier Name < FEBA ELEKTRONİK>


Repair Supplier Site < IZMIR, TURKEY >
Repair Quality Lead Person < Egemen DURAL>

Month of Data Review < 2024 JANUARY VOYIX REPORT>


Date of Quality Review < 29.02.2024>

Q U A L I T Y M AT T E R S - T R E AT E V E R Y C U S T O M E R L I K E YO U R O N LY C U S T O M E R
FEBA ELEKTRONIK
QA REPORT
AGENDA
OVERALL KPI SUMMARY– LAST 12 MONTHS
OBF, ELF, MTBR

QUALITY DASHBOARD – HIGH LEVEL VIEW OBFs-LAST 12 MONTHS


OBF BY REPAIR GROUPS
MODULE TYPE PARETO
REPAIR GROUP FAILURE CLASSES

QUALITY DASHBOARD – HIGH LEVEL VIEW CURRENT MONTH


OBF BY REPAIR GROUPS
MODULE TYPE PARETO
REPAIR GROUP FAILURE CLASSES

ACTIONS / IMPROVEMENTS
4970528876 SHIPOUT W/O KIT ISSUE
FEBA ELEKTRONIK
QA REPORT

OVERALL KPI SUMMARY– LAST 12 MONTHS


OVERALL KPI SUMMARY– LAST 12 MONTHS

BASIC INFORMATIONS
All informations in this report are belong to only Voyix.

All months’ OBF and ELF rates have been calculated with the
new Global Repair Operations Metrics (RCN-1045).

The OBF rate has been calculated as % 0,98 for January there
are 2 OBF’s on January. Considering the whole year, the OBF
amount in January is below the average. OBF rate is below the
target.

ELF is below the target for JAN_2024 (%2,5) there are 5 ELF
units. ELF spare parts usage and failures are tracking by FEBA.

No issue on MTBR. Considering the whole year, MTBR is almost


the highest. MTBR is above the target for last 12 months.
FEBA ELEKTRONIK
QA REPORT
QUALITY DASHBOARD – HIGH LEVEL
VIEW OBFs-LAST 12 MONTHS
QUALITY DASH BOARD – HIGH LEVEL VIEW OBFs-LAST 12 MONTHS
Performance Analyses
Last 12 months FEBA have 23 OBFs totally. When we compare with the same time range for
between Feb22_ Jan23 there were 26 OBFs. There is decreasing for the OBFs and FEBA
tracking the situations for continuously. LCD monitor’s are created %85 of OBFs. All OBFs are
important and inspected by FEBA. But need to focus on LCD Monitor OBFs.
OBF Failure Classes by Commodities breakdown;

REPAIR CODE1 REPAIR CODE2 MODULE STATUS FEBA FAILURE CLASS CLCA REF#
LCD MONITOR LCD15-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00393
LCD MONITOR LCD6-RET CLOSED(IW) NFF RE-CAPA-00402
LCD MONITOR LCD15-RET TOUCH CLOSED(IW) NFF RE-CAPA-00404
LCD MONITOR LCD19-RET TOUCH CLOSED(OOW) NFF RE-CAPA-00405
LCD PANEL PAN15-LED CLOSED(OOW) DAMAGED PARTS RE-CAPA-00419
LCD MONITOR LCD30-RET TOUCH CLOSED(IW) NFF RE-CAPA-00437
LCD MONITOR LCD20-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00441
LCD MONITOR LCD20-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00476
LCD MONITOR LCD17-RET CLOSED(OOW) FUNCTIONAL FAILURE RE-CAPA-00488
LCD MONITOR LCD20-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00508
LCD MONITOR LCD20-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00509
LCD MONITOR LCD15-RET CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00510
PCB - BOARD PCB-POS MB CLOSED(IW) NFF RE-CAPA-00527
LCD MONITOR LCD17-RET CLOSED(SCRAP) FUNCTIONAL FAILURE RE-CAPA-00539
LCD MONITOR LCD15-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00541
LCD MONITOR LCD15-RET TOUCH CLOSED(IW) NFF RE-CAPA-00616
LCD MONITOR LCD15-RET TOUCH CLOSED(IW) NFF RE-CAPA-00641
PCB - BOARD PCB-POS MB CLOSED(OOW) NFF RE-CAPA-00642
PCB - BOARD PCB-POS MB CLOSED(OOW) NFF RE-CAPA-00643
LCD MONITOR LCD20-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00673
LCD MONITOR LCD6-RET CLOSED(IW) NFF RE-CAPA-00674
LCD MONITOR LCD15-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00690
LCD MONITOR LCD15-RET TOUCH CLOSED(SCRAP) DAMAGED PARTS RE-CAPA-00691

Explanation of Failure Class


DAMAGED Parts– Parts received with physical damage.
NFF – Defective unit is tested and no functional failure is found. DEF Unit is working.
FF(Functional Failure) – Defective Unit is tested and functional failure is found. DEF Unit is
not working (Sensor Failure, Motor Failure, Software Failure etc. . )
QUALITY DASH BOARD – HIGH LEVEL VIEW – CURRENT MONTH

Performance Analyses

In JAN_2024;

There are two Damaged Parts OBF’s.

There is no Functional Failure or NFF device in this month's


OBFs

If there was Functional Failures, breakdown will be shown in below


table;

REPAIR CODE 1 FAILURE CATEGORY CAPA#


FEBA ELEKTRONIK
QA REPORT

ACTIONS / IMPROVEMENTS
CLCA SUMMARY– HIGHLIGTED OBFS
Below screenshot taken from 4970528876 PDF file from PLM Merlin
NO CLCA CAPA# - FEBA ACTION# - 232
Highlight Date: 13.07.2022

Detailed Desc. Of Failure: 4970528876 SHIPOUT W/O KIT ISSUE


-------------------------------------------------------------------------------------- -----------
OBF have been highlighted by APAC Procurement Team [Suresh, Karthigayan], NCR Quality
Engineering have been informed about situation.

• Interim Containment Plan


The request from field is «Unit must be send with Funnel»

FEBA Check the kit parts of 4970528876 when pricing. But parts are «Not Available or
Not on File». Due to this, price was given for only repair, kits are not included.

FEBA check after OBF highlighted. Kit parts are still «Not Available or Not on File».

23-999912458, 23-999912538 and 23-999912539 has been added to FEBA tracking


System.
Need advise about create CAPA now or after arrival of units to FEBA.

NCR have been informed about the OBF. Waiting information from NCR Service Desing

• Route Cause Analysis Action Plan


Parts are «Not Available or Not on File» in NCR WSL Data Warehouse.

• Short Term Corrective Action Plan


NCR have been informed about the OBF.

• Long Term Corrective Action Plan

FEBA in communication with manufacturer KingA Moulding. Only 1 part was produced
by KingA Mouldings, part was not funnel. FEBA working with NCR to find other
manufacturers of other spare parts.