Professional Documents
Culture Documents
so you can take pride in doing something positive to help and save our
environment for the benefit of future generations.
World wide network of dealers and highly trained staff.
Cold
closed circuit fluid
Cold
to collector
water Hot
closed circuit fluid
from collector
Electric Backup,
Fully covered,
safe and secure
Electric Back up
Fully covered,safe and secure.
Fully Automatic
Exposed of Weld Points to raw water, two different metal while welding ,alters the properties of
the metal
One way to do this is to apply a protective coating over the metal surface.
This creates a barrier between the metal and the surrounding oxygen.
The Solahart storage tank can be considered as a ceramic tank with a steel casing.
All Solahart tanks have an internal double layer ceramic lining, applied after all the
fabrication work on the tank is complete to ensure tank integrity.
The Solahart storage tank can be considered as a Ceramic Tank with a Steel Casing.
All Solahart tanks have an internal double layer ceramic lining, applied after all the
fabrication work on the tank is complete to ensure the tank integrity.
The double ceramic lining is fused to the steel casing at over 800°C, this ensures no
cracking or crazing of the lining under normal daily temperature variations and
pressures.
The second Primaglaze® coat has been specifically formulated to ensure that the tank
will withstand near boiling water over the life time of the tank, something that ordinary
water heater can not withstand.
Metals fused with ceramics have been used in some very extreme condition such as the
nose cones of NASA space shuttles.
The vessel is fully encased in pressure injected polyurethane foam,100% CFC free.
The insulation foam adheres to both the aluminum outer case and the surface of the
vessel thereby forming a vapor - tight skin. The skin ensures the polyurethane foam
retains its high insulating qualities that are not normally possible in free rise unsealed
foams. Similar benefits are not offered by blanket or free-rise form insulation types.
As hot water is drawn from a Solahart system, cold water is prevented
from mixing with hot water.
The incoming cold water enters the tank through a cone shaped strtifier,
which allow cold water entry very softly, which diminishes the diluting
effect of the cold water and helps in keeping HOT WATER HOT.
Once the closed circuit is sealed, the fluid becomes stable. Because oxygen
and other substances are excluded from the closed circuit, there is no need
for any servicing or recharging of the Hartgard
of the Hartgard.
The major component of Hartgard, propylene glycol has a boiling point of 188˚C. At very
high temperature it can oxidize. But in the closed circuit of a Solahart solar water heater
two factors ensure this does not occur. First, the oxygen presence during recharging quickly
by the buffer present in the Hartgard,
Secondly, because the closed circuit is sealed, there is no ongoing supply of oxygen to
"feed" the oxidization reaction. This means that even under very high temperature
Hartgard remains stable.
The external case of the storage tanks and heat exchangers are made from two sheets
of aluminum that are lock seamed together. The top section is 0.4 mm thick with a stucco
finish and the base has a brush finish and is 0.7 mm thick.
The material used for the end covers is polypropylene, this gives excellent stability under
prolonged exposure to ultra-violet rays, and high temperatures. It retain its toughness
and flexibility without cracking in sunlight or at temperatures between -20°C to 104°C.
Protecting The Exterior
Polypropylene End Cap
Aluminum
Polypropylene End Cap
The Solahart storage tank is protected from the weather and UV radiation by an
aluminum casing and Polypropylene ends.
Decades of manufacture and use have shown that the casing is strong and very durable,
even in coastal locations.
Key Features
☼ 24 hrs of hot water, with maximum usage of Solar Energy, all through the year.
☼ State of Art Closed circuit design makes it suitable for frost prone & poor water quality.
☼ The high efficiency Black Polyester Powder coated absorber maximizes the transfer of
available solar energy.
☼ No Weld points in tank exposed to water, in fact the water in the systems never
never comes in contact with metal directly, weather its Tank or Collectors.
☼ Superior Protection of storage tank from harshest water with two coats of
Primaglaze® ceramic lining.
☼ Sacrificial Anode -All Solahart tanks are fitted with magnesium anodes to protect to
protect the tank and the booster from corrosion.
Collector, 35 raiser
Panel Insulation
Aluminum Framing
r.
2. 4
Mt
8M
tr.
15
2. 5
Length 2.48 Mtr. 2.48 Mtr. 2.48 Mtr.
Height 0.51 Mtr. 0.51 Mtr. 0.51 Mtr.
Width 1.615 Mtr. 2.515 Mtr. 3.485 Mtr.
Direct Systems Indirect Systems
Raw water get heated in Collector Hartgard get heated in the
and rises directly and stored in tank Collector and circulate in the
Jacketed tank
Multiple Installations
Installation Options, without compromising
with building elevation.
Roof Top as well as Flat Terrace Installation
Solahart Solar Tank production
technology is fully automated
and is further
enhanced by using a
ceramic lining.