You are on page 1of 4

Versatility

in

Viscosity

measurement
LABORATORY INSTRUMENT CALIBRATION & CERTIFICATION
Annual service program for your Brookfield Viscometer which includes replacement of parts as necessary and cleaning of the sensing system to guarantee long life and good performance. Program includes an updated Certificate of Calibration. Rush 24-hour and 48-hour service available as well as loan instruments.

TEMPERATURE CONTROL SYSTEMS


Brookfield TC series digital baths/circulators and coolers with range capability -20C to 200C. Brookfield Thermosel System for measurement of small samples to 300C.

VIS CAL KIT


This must-have kit provides all the necessary items to verify calibration including a Brookfield 600ml beaker, pint of silicone viscosity standard, dispensing bottle for cleanup and Trapper cleaning agent (available only in the USA).

SMALL SAMPLE ADAPTER DISPOSABLE CHAMBERS


Disposable sample chambers are ideal for hard-to-clean materials because there is no cleaning. You take the measurement, lift out the chamber and toss it away. A special kit is available to retro-fit your existing Small Sample Adapter.

PRACTICAL COURSE ON VISCOSITY MEASUREMENTS


A single day course which covers such topics as the principle of viscometer operation, calibration, rheology, methodology and data interpretation. Classes available at major metropolitan areas throughout the United States and at our plant. Customer on-site classes may also be arranged.

BROOKFIELD ENGINEERING LABORATORIES, INC.

11 Commerce Boulevard, Middleboro, MA 02346-1031 USA TEL: 508-946-6200 or 800-628-6139 (USA only) FAX: 508-946-6262 INTERNET: www.brookfieldengineering.com

ISO 9001:2000 CERTIFIED

FACTOR FINDER
v
VISCOMETER TORQUE RANGE SPINDLE NUMBER*
INSTRUCTIONS This Factor Finder applies to Brookfield Dial Reading Viscometers. Torque ranges include LV, RV, HA and HB with standard spindles. Insert slide in sleeve so appropriate torque/ spindle selection is visible in window. To convert Viscometer dial readings to centipoise (mPas), adjust slide until Viscometer torque range and spindle number being used appear in window. Multiply reading noted on Viscometer dial (0-100 scale) by factor shown beside speed at which measurement is being made. Turn slide over for HA/ HB factors. Dial Reading x Factor = Viscosity in Centipoise (mPas) Example: LVT with #61 spindle at 6 rpm Dial Reading: 75 Factor: 10 75 x 10 = 750 centipoise (mPas) Full scale viscosity range for any speed and spindle combination is the maximum viscosity that can be measured. Calculate as shown.

v
FACTOR

SPEED-RPM

BROOKFIELD ENGINEERING LABORATORIES, INC. 11 Commerce Blvd., Middleboro, MA 02346-1031 USA T: 508-946-6200 or 800-628-6139 F: 508-946-6262 W: www.brookfieldengineering.com

K = 1000 *LV spindles may be marked as either 1, 2, 3, 4 (for use with Dial Viscometers) or 61, 62, 63, 64 (for use with Digital Viscometers)

Factor x 100 = Full Scale Viscosity Range Example: LVT with #61 spindle at 6 rpm 10 x 100 = 1000 cP (mPas) Factor: 10

BROOKFIELD ENGINEERING LABORATORIES, INC.

11 Commerce Blvd., Middleboro, MA 02346-1031 USA T: 508-946-6200 or 800-628-8139 F: 508-946-6262 W: www.brookfieldengineering.com

RV
01
.5 1 2 2.5 4 5 10 20 50 200 100 50 40 25 20 10 5 2

RV
02
.5 1 2 2.5 4 5 10 20 50 100 800 400 200 160 100 80 40 20 8 4

RV
03
.5 1 2 4 5 10 20 50 2K 1K 500 250 200 100 50 20

RV
04
.5 1 2 4 5 10 20 50 4K 2K 1K 500 400 200 100 40

RV
05
.5 1 2 4 5 10 20 50 8K 4K 2K 1K 800 400 200 80

RV
06
.5 1 2 4 5 10 20 50 20K 10K 5K 2.5K 2K 1K 500 200

RV
07
.5 1 2 4 5 10 20 50 80K 40K 20K 10K 8K 4K 2K 800

LV
.3 .6 3 6 12 30 60 200 100 20 10 5 2 1

LV
.3 .6 3 6 12 30 60 1K 500 100 50 25 10 5

LV
.3 .6 3 6 12 30 60 4K 2K 400 200 100 40 20 .3 .6 3 6

LV
20K 10K 2K 1K 500 200 100

1 or 61 2 or 62 3 or 63 4 or 64

1.5 40

1.5 200

1.5 800

1.5 4K

2.5 400

2.5 800

2.5 1.6K

2.5 4K

2.5 16K

12 30 60

100 1

100 10

100 20

100 40

100 100

100 400

BROOKFIELD ENGINEERING LABORATORIES, INC.

11 Commerce Blvd., Middleboro, MA 02346-1031 USA T: 508-946-6200 or 800-628-8139 F: 508-946-6262 W: www.brookfieldengineering.com

HA H01
.5 1 2 2.5 5 10 20 50 100 400 200 100 80 40 20 10 4 2

HA H02
.5 1 2 2.5 5 10 20 50 100 1.6K 800 400 320 160 80 40 16 8

HA 03
.5 1 2 2.5 5 10 20 50 100

HA 04
8K 4K 2K 1.6K 800 400 200 80 40

HA 05
.5 1 2 2.5 5 10 20 50 100 16K 8K 4K 3.2K 1.6K 800 400 160 80

HA 06
.5 1 2 2.5 5 10 20 50 100

HA 07
160K 80K 40K 32K 16K 8K 4K 1.6K 800

HB H01
.5 1 2 2.5 5 10 20 50 100 1.6K 800 400 320 160 80 40 16 8

HB H02
.5 1 2 2.5 5 10 20 50 100 6.4K 3.2K 1.6K 1.28K 640 320 160 64 32

HB 03
.5 1 2 2.5 5 10 20 50 100 16K 8K 4K 3.2K 1.6K 800 400 160 80

HB 04
.5 1 2 2.5 5 10 20 50 100 32K 16K 8K 6.4K 3.2K 1.6K 800 320 160

HB 05
.5 1 2 2.5 5 10 20 50 100 64K 32K 16K 12.8K 6.4K 3.2K 1.6K 640 320

HB 06
.5 1 2 2.5 5 10 20 50 100

HB 07
640K 320K 160K 128K 64K 32K 16K 6.4K 3.2K

4K .5 2K 1 1K 2 800 2.5 400 5 200 10 100 20 40 50 20 100

40K .5 20K 1 10K 2 8K 2.5 4K 5 2K 10 1K 20 400 50 200 100

160K .5 80K 1 40K 2 32K 2.5 16K 5 8K 10 4K 20 1.6K 50 800 100

You might also like