You are on page 1of 1

SERVINTEGRAL LTDA

CERTIFICATE OF CALIBRATION
CERTIFICATE NUMBER 782 Model: 6020AB Maximum Capacity: 600,00 Inspector: 3 Serial No: DLD53384 Units: lbf.ft Date of Calibration: 11/10/13

Set Torque
120,0 360,0 600,0

Min
115,2 345,6 576,0

Max
124,8 374,4 624,0 124,4 364,4 600,2

Actual Readings
123,7 368,6 601,2 124,1 368,2 600,9 124,2 368,5 601,2 124,6 368,6 601,7

The test equipment used for this calibration complies with the accuracy requirements of: NTC 5330-2004 The permissable variation is +/- 4,00% of reading. Calibration carried out by SERVINTEGRAL LTDA Ambient test conditions: Humidity 45,0% Quality Manager: R.H. TEST EQUIPMENT USED Tester Model: 43228 Serial No.: 62202

Test Transducer Used: Model: REGISTRO 50676LOG 21144 Serial No.: 68743

The uncertainty of the test equipment at 21 degrees C is: < +/- 0,199% The uncertainties are for a confidence probability of not less than 95% The test equipment used in the performance of the above test has international traceability through an accredited laboratory. Laboratory No. 0256

You might also like