TeSys contactors

Dimensions

TeSys D contactors
Control circuit: a.c.

LC1 D09D18 (3-pole)

LC1 D25D38 (3-pole), LC1 DT20DT40 (4-pole)


44

DF565145.eps

DF510934.eps

44
Minimum electrical clearance

LA4

12,5
(LAD 8)

c
c1
c2
c3

LC1
b without add-on blocks
b1 with LAD 4BB
with LA4 Dp2
with LA4 DF, DT
with LA4 DW, DL
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
c2 with LA6 DK10, LAD 6K10
c3 with LAD T, R, S
with LAD T, R, S and sealing cover
(1) Including LAD 4BB.

45

12,5
(LAD 8) (1)

D09D18 D093
D123
77
99
94
107
123 (1)
110 (1)
132 (1)
119 (1)
139 (1)
126 (1)
84
84
86
86
117
117
129
129
137
137
141
141

10

D099
D129
80
95,5
111.5 (1)
120.5 (1)
127.5 (1)
84
86
117
129
137
141

D25
D38
85
98
114 (1)
123 (1)
130 (1)
90
92
123
135
143
147

D183
D323
99
107
123 (1)
132 (1)
139 (1)
90
92
123
135
143
147

LC1 D40AD65A (3-pole), LC1 DT60ADT80A (4-pole)

DT32 and
DT40
91

97
99
131
143
151
155

Minimum electrical clearance

D188, D258,
DT323 and DT403
105

97
99
131
143
151
155

LA4

127

b1

LAD 4BB3

117

D098, D128,
DT203 and
DT20 and DT25 DT253
85
99
98

114

129

190

90
90
92
92
123
123
135
135
143
143
147
147

12,5
(LAD 8) (1)

32 44

DF565147.eps

Min. electrical clearance

122

45

LC1 D80 and D95 (3-pole), LC1 D80004 and


D80008 (4-pole), D40008 and D65008 (4-pole)

LA4 DpB

DF569184.eps

12,5
(LAD 8)

c
c1
c2
c3

b1

10

b1

b1

LA4

Minimum electrical clearance

LAD 4BB3

12

12

c1

LA4 DpB

c2

12,5
(LAD 8N)

c3
LC1

c
c1
c2
c3

12,5
(LAD 8N)

12,5
(LAD 8)

12,5
(LAD 8)

D40AD65A DT60ADT80A D40008

D80

D95, D65008

D80004

D80008

55

70

85

85

85

96

96

b1 with LA4 Dp2

135

135

135

135

135

with LA4 DB3 or LAD 4BB3

136

135

with LA4 DF, DT

157

142

142

142

142

142

with LA4 DM, DW, DL

166

150

150

150

150

150

without cover or add-on blocks

118

118

125

125

125

125

140

with cover, without add-on blocks

120

120

130

130

139

150

150

150

150

150

150

147

158

158

158

158

c2 with LAD 6K10 or LA6 DK

163

163

159

170

170

170

170

c3 with LAD T, R, S

171

171

167

178

178

178

178

175

175

171

182

182

182

182

c1 with LAD N (1 contact)


with LAD N or C (2 or 4 contacts)

with LAD T, R, S and sealing cover

5/92

D115004
150
174
185
188
188
132

150
155
168
172

D1150046
155
174
185
188
188
115

150
155
168
172

Version : 12.1

Min. electrical clearance

10

c
c1
c2
c3

17/04/2013

LA4

LAD 8

b1

D115, D150
120
174
185
188
188
132
136
150
155
168
172

158

LC1
a
b1 with LA4 DA2
with LA4 DF, DT
with LA4 DM, DL
with LA4 DW
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LAD N or C (2 or 4 contacts)
c2 with LA6 DK20
c3 with LAD T, R, S
with LAD T, R, S and sealing cover

DF569186.eps

LC1 D115 and D150 (3-pole), LC1 D115004 (4-pole)

24531-EN

Control circuit: d.c. or low consumption

LC1 D09D18 (3-pole)

LC1 D25D38 (3-pole)


DF565150.eps

Minimum electrical clearance

10

DF565149.eps

Minimum electrical clearance

45

45

10

c1
c2
c3

c1
c2
c3

LC1
b
c without cover or add-on blocks
with cover, without add-on blocks
c1 with LADN or C (2 or 4 contacts)
c2 with LA6DK10
c3 with LADT, R, S
with LADT, R, S and sealing cover

D09D18
77
93
95
126
138
146
150

D093D123
99
93
95
126
138
146
150

D099D129
80
93
95
126
138
146
150

D25D38
85
99
101
132
144
152
156

D183D323
99
99
101
132
144
152
156

DT20 and DT25


D098 and D128
85
99
123
135
143
147

DT203 and DT253


D0983 and D1283
99
99
123
135
143
147

DT32 and DT40


D188D258
91
107
131
143
151
155

DT323 and DT403


D1883 and D2583
105
107
131
143
151
155

LC1 DT20DT40 (4-pole)

DF565151.eps

Minimum electrical clearance

45

10
c1
c2
c3
LC1
b
c
c1
c2
c3

with cover
with LAD N or C (2 or 4 contacts)
with LA6 DK10
with LAD T, R, S
with LAD T, R, S and sealing cover

LC1 D40AD65A (3-pole), LC1 DT60ADT80A (4-pole)

LC1 D80 and D95 (3-pole), LP1 D80004, LP1 D80008 (4-pole),
LP1 D40008 and D65008 (4-pole)
DF510661.eps

DF569184.eps

LA4 DpB

Min. electrical clearance

Min. electrical clearance

127

b1

122

117

LAD 4BB3

LAD 4BB3

12

12

c1

LA4 DpB

c2

12,5
(LAD 8N)

c3

12,5
(LAD 8N)

LC1 D40A LC1


D65A
DT60ADT80A
a
55
70
b1 with LAD 4BB3
136
136
with LA4 DF, DT
157
157
c without cover or add-on blocks
118
118
with cover, without add-on blocks
120
120
c1 with LAD N (1 contact)

with LAD N or C (2 or 4 contacts)


150
150
c2 with LA6 DK10
163
163
c3 with LAD T, R, S
171
171
with LAD T, R, S and sealing cover
175
175
LC1 D115ppp and LC1 D150ppp with c coil: see page 5/92.

24531-EN

c1
c2
c3

Version : 12.1

LP1 D40008
andD65008
85

182

196
202
213
221
225

LC1
D80 and D95
85

181
186
204
210
221
229
233

17/04/2013

LP1 D80004

LP1 D80008

96

181

204
210
221
229
233

96

196

204
210
221
229
233

5/93

TeSys contactors

Mounting

TeSys D contactors

LC1 D09D38, DT20DT40

LC1 D40AD65A, LC1 DT60A and DT80A, LC1 D80 and D95,
LC1 D40008 and D65008

b
=

On mounting rail AM1 DL200 or DL201 (width 75 mm) (2)


On mounting rail AM1EDppp or AM1 DE200 (width 35 mm)
DF511013.eps

810610.eps

On mounting rail AM1 DP200, DR200 or AM1 DE200 (width 35 mm)

Control circuit: a.c.


LC1
b
c
c

(AM1 DP200 or DR200) (1)


(AM1 DE200) (1)

Control circuit: d.c.


LC1

b
c (AM1 DP200 or DR200) (1)
c (AM1 DE200) (1)
(1) With safety cover.

D09
D18
77
88
96

D25
D38
85
94
102

DT20
and DT25
85
94
102

DT32
and DT40
100
109
117

D09
D18
77
97
105

D25
D38
85
103
110

DT20
and DT25
94
103
111

DT32
and DT40
109
118
1236

Control circuit: a.c.

LC1
b
c
c
c

(AM1 DL200) (1)


(AM1 DL201) (1)
(AM1 EDppp or DE200) (1)

Control circuit: d.c.

LC1

D40AD65A
DT60ADT80A
122

128

D80
and D95
127
147
137
137

D40008
and D65008
127
143
133
133

D40AD65A
DT60ADT80A

128

D80
and D95
205
195
128

D40008
and D65008
200
190
190

c (AM1 DL200) (1)


c (AM1 DL201) (1)
c (AM1 EDppp or DE200) (1)
(1) With safety cover.
(2) Except for LC1 D40AD65A, LC1 DT60A and DT80A.

LC1 D80 and D95, LP1 D80


DF565154.eps

On 2 mounting rails DZ5 MB on 120 mm centres

DZ5 ME5

Control circuit: a.c.

15

110

120

LC1
c with cover

40

D80 and D95


130

Control circuit: d.c.

LC1
c with cover

D80 and D95


186

LP1
c

D80
181

LC1 D115, D150

158

100

810611.eps

On 2 mounting rails DZ5 MB on 120 mm centres

Control circuit: a.c. or d.c.

LC1
c (AM1 DP200 or DR200)
c (AM1 DE200 or EDppp)

Selection:
pages 5/194 to 5/225

5/94

Characteristics:
pages 5/50 to 5/55

References:
pages 5/62 to 5/67

Version : 12.1

D115 and D150


134.5
142.5

D1156 and D1506


117.5
125.5

Schemes:
pages 5/96 to 5/97

17/04/2013

24531-EN

LC1 D09D38 and LC1 DT20DT40


On 2 mounting rails DZ5 MB

Control circuit:

LC1
c with cover
G
H
H1
4-pole contactors
LC1

H1

DF510718.eps

DZ5 ME8

15

c
G
H
H1

LC1 D09D38 and LC1 DT20DT40

a.c.

D25D38
92
35
60
70

D09D18
95
35
70
70

D25D38
101
35
70
70

DT20
and DT25
92
35
60
70

DT32
and DT40
100
35
60
70

DT20
and DT25
101
35
70
70

DT32
and DT40
109
35
70
70

LC1 D40AD65A, LC1 DT60ADT80A

On pre-slotted mounting plate AM1 PA, PB, PC and panel mounted

128

AF1 EA4

37,5

Control circuit:

a.c

LC1
c with cover
G
H
LC1

D09D18
86
35
60/70
DT20
and DT25
80
35
60

c with cover
G
H

d.c

D25D38
92
35
60/70
DT32
and DT40
93
35
60

D09D18
95
35
70
DT20
and DT25
118
35
70

Control circuit:

D25D38
101
35
70
DT32
and DT40
132
35
70

LC1
c

LC1 D09D38, LC1 DT20DT40

120

a.c

=
=

35

110

=
with cover

120

50

60/70
c

D40A65A ,
DT60ADT80A

DF511562.eps

2xM4 2x4,5
=

DF565155.eps

LC1
c with cover
4-pole contactors
LC1

d.c.

D40A65A ,
DT60ADT80A

On pre-slotted mounting plate AM1 PA, PB, PC and panel mounted

2xM4

Control circuit:

a.c

3x6,5

LC1 D80 and D95, LC1 D40008 and D65008, LP1 D80

Panel mounted

with cover

37,5

AF1 EA4

100/110

128

DB402218.eps

DF510439.eps

On pre-slotted mounting plate AM1 PA, PB, PC

d.c.

D09D18
86
35
60
70

35

d.c

40

D09D18
86

D25D38
92

D09D18
95

D25D38
101

DT20
and DT25
90

DT32
and DT40
98

DT20
and DT25
90

DT32
and DT40
98

Control circuit:

LC1

AF1 EA6

a.c

40

3x6,5

d.c.

c with cover
LP1

D80 and D95,


D40008 and D65008
130

D80 and D95


D40008 and D65008
186
D80

181

D115
132
96/110
130/144

D1156
115
96/110
130/144

D150
132
96/110

without cover

LC1 D115, D150

130
158

DF565389.eps

Panel mounted

LC1
c
G (3-pole)
G (4-pole)

c
Selection:
pages 5/194 to 5/225

24531-EN

Characteristics:
pages 5/50 to 5/55

References:
pages 5/62 to 5/67

Version : 12.1

D1506
115
96/110

Schemes:
pages 5/96 to 5/97

17/04/2013

5/95