QUESTION 4.38

Q(m3/s) 0.001 tube OD wall thickness tube ID


P(bars) 70 mm mm m mm m
v(m/s) 6.1 10 1 0.001 8 0.008
SF 8 10 1.5 0.0015 7 0.007
π 3.142 10 2 0.002 6 0.006
tensile strength(Mpa) for: 12 1 0.001 10 0.01
SAE 1010 379 12 1.5 0.0015 9 0.009
AISI 4130 517 12 2 0.002 8 0.008
14 2 0.002 10 0.01
15 1.5 0.0015 12 0.012
determine the inside diameter(ID) 15 2 0.002 11 0.011
ID(m) 0.014446 16 2 0.002 12 0.012
ID(mm) 14.44648 fig 4-21

a)from fig. 4-21,try 15mm OD


t(m) 0.0015
Di(m) 0.012

BP(Mpa) 94.75
WP(Mpa) 11.84375

OK since the WP is greater than 70bars

b)from fig. 4-21, try 15mm OD


t(m) 0.0015
Di(m) 0.012

BP(Mpa) 129.25
WP(Mpa) 16.15625

OK since the WP is greater than 70bars