SEQUENTIAL SAMPLER COMBINE

VEnvirot,..,
,-SIWBEEH mOVW«£5 —

A microprocessor based air sampler designed


to monitor air quality at pre-programmed
intervals.

SEQUENTIAL AIR SAMPLER


ENVIROTECH APM 500
(Jointly developed by NEERI and Envirotech)
SEQUENTIAL AIR SAMPLER
ENVIROTECH APM 500
(Jointly developed by NEERI and Envirotech)

W e t c h e m i c a l m e t h o d s the only The A P M 500 is an improvement advantages of the wet chemical methods,
viable option over traditional s a m p l e r s yet provides samples which can estimate
In India measurement of the However, the commonly available both short-term peak concentrations and
concentration of gaseous pollutants in samplers (whether specific Low Volume long term average levels.
ambientair has depended upon wetchemical Samplers or more commonly attachments The APM 500 system uses a
sampling techniques since the enforcement to High Volume Air Samplers) used in such sophisticated microprocessor based
of the Air Pollution Control Act commenced monitoringsufferfromanimportantlimitation. controller to automatically change the
in 1981 -82. Use of automatic direct reading The s a m p l e o b t a i n e d t h r o u g h t h e s e impingers used to absorb gaseous pollutants
instruments in India and other developing instruments provides only the long term at pre-programmed time intervals, The
countries is out of the question for the near average concentrations as a single value to controller also maintains a record, accurate
future due to their high cost, need of represent the entire 8 / 24 hour sampling t'j the nearest minute, of the actual duration
sophisticated facilities such as calibration period. Sampling over shorter periods to eachsamplewascollected in. TheSequential
systems and air-conditioned housing besides monitorvariations inpollutantconcentrations Sampler therefore makes it possible to obtain
a host of problems of operation and with time would require frequent change of a set of short-term samples with minimum
maintenance. In contrast, instruments using bubbler trains and resetting of the sampler operator effort.
wet chemical niethods with appropriate which is rarely practicable. The APM 500 Sequential Sampler has
bubblers for sample collection are simple, Realizing the limitation of the traditional benefited from the academic excellence of
inexpensive and reliable and with ample Samplers, Envirotech jointly with NEERI N E E R I (The p r e m i e r C S I R Lab for
educated manpower available for laboratory has developed the "Sequential Air Sampler", Environmental Engineering Research) and
analyses, offer the only practical alternative Envirotech APM 500, which retains the the d e c a d e long field e x p e r i e n c e of
for developing countries in the foreseable Envirotech as a leading manufacturer of
future. i n d i g e n o u s Air P o l l u t i o n Monitoring
instruments. Thus care has been taken to
ensure that only inert materials come in
contact with the gases prior to absorption,
and, the system has been partitioned into
functional modules for ease of transportation
and servicing.

i « * /* ' . f
W « t n a # K ! , M l / —

§ • f I ;r!
Applications: Monitoring concentrations of gaseous
pollutants in ambient air or in stack emissions. Can
replace continuous monitors for S0 2 , NH3, H2S and CS2

Jointly developed by NEERI and Envirotech


APM 500 IS THE APPROPRIATE INDIGENOUS ALTERNATIVE
TO CONTINOUS MONITORING 1

Important features of the APM 500 system recorded data.


are: • Flexibility
• Precise control of sample Being based on wet chemical
duration techniques, the system is applicable
The system uses a microprocessor for a wide variety of gaseous pollutants
controller to operate the sampler and a including Oxides of Sulphur a n d
Quartz-crystal clock to keep track of Nitrogen, Halogens, Ammonia,
samples. The duration of "power Sulphides etc.
failures" are recorded in memory and • Stable Flow Control
can be recalled to relate each sample The sampling rate of each sample is
Hot-Climate Compatibility to the exact time period it represents. controlled by an in-built flow control-
The large capacity cold box of APM 500 orifice to guarantee a fixed sampling
• Data stored in non-volatile
maintains the temperature of absorbing rate over time. The system design
memory
solutions over extended periods of time minimizes the number of joints between
Operation time records of individual
thus ensuring complete absorption and the flow control system and the impinger
samples are maintained by the A P M
minimum loss of solutions by evaporation train to minimise chances of any
500 in special memory chips which do
during hot Indian summers. leakages.
not loose data on loss of power.
• Hard-copy of data available • Inert gas handling materials
The APM 500 has a built-in printer The sampling hose is made of Teflon
driver so thatyoucan use anycommon and Silicone rubber tubes have been
Centronix compatible printer to retrieve used to couple the impingers.

Manufactured exclusively by Envirotech


SYSTEM SPECIFICATIONS

System Controller Based on Z-80 CPU with built-in real time clock and printer driver.

Valve Assembly Bank of ten solenoid operated valves with in-built flow control orifices

Sampling Trains Eight trains of 2 Nos. 35 ml. midget impingers placed in an Ice Box. Two such boxes provided with
each system to facilitate quick change-over.

Sampling Ice Boxes 2 Nos. light and sturdy fiberglass boxes with adequate insulation and water draining tap, locking
arrangement and handle for ease of carrying.

Sampling Time Totally flexible, (with a practical range of 15-500 minutes for each sample) can be programmed in
the controller. Operation of more than one train simultaneously (in parallel) possible.

Sampling Time Record Maintained to the nearest minute, the system also keeps track of power failures.

Suction Pump Oil free diaphram type, continuous duty rated for operation over long periods, capable of giving
flows up to 5 LPM at adequate suction pressures.

Extension Hoses and Cables A 20 metre long vacuum hose and valve control cable is provided so that the microprocessor
controller can be located safely indoors, away from the sampling location.
Power Requirement 220 Volts single phase AC mains fed through a CVT. Total system load 150VA.

Sampling probe 1 m long SS Probe pipe with braided Teflon hose pipe fitted with suitable couplers.

Optional

Stack Sampling Probe SS Nozzle and thimble type filter holder with M.S. Probe support structure
Specifications subject to change without notice

WARRANTY
All E n v i r o t e c h p r o d u c t s carry a o n e year w a r r a n t y for t r o u b l e - f r e e operation.

After-sale service, support and spares


E n v i r o t e c h m a i n t a i n s its e q u i p m e n t t h r o u g h the central office at Delhi a n d regional c e n t e r s l o c a t e d in different parts of the country. In m o s t c a s e s t h e regional
r e p r e s e n t a t i v e s are t e c h n i c a l l y c o m p e t e n t p r o f e s s i o n a l s . For a n y after sales s u p p o r t s e r v i c e contact y o u r n e a r e s t s e r v i c e c e n t e r or E n v i r o t e c h at t h e
Delhi Office.

Envirotech East (P) Ltd. Hytek Scientifics, Inc.


97-C. Harish Mukerjee Road, Calcutta - 700 026. UBAS-410, Babu Khan Estate, Basheer Bagh, Hyderabad - 500 001,
West Bengal. Tel: (033) 48 1128 Andhra Pradesh, Tel: (040) 24 0835, 24 2814

Bajaj Engineering Systems B.K. Rao & Associates


L-33, Income Tax Colony, Durgapura. Jaipur - 302 018. No. 10. IXth Avenue. Harington Road. Chetpet. Madras - 600 031,
Rajasthan, Tel: (0141) 55 1124 Tamil Nadu, Tel: (044) 826 3560

Safetech Consultants Pvt. Ltd. Enviro Designs & Equipments


25-26 Chinubhai Towers, Ashram Road, Ahmedabad- 380 009, D-1 Aroma Gardens, Sivarama Menon Road, Lissie Jn. Ernakularn,
Gujarat, Tel: (0272) 40 3444 (Ext. 22). Fax: (079) 46 9101 Kochi - 682 018, Kerala, Tel: (0484) 34 1907

For more details contact:

Envirotech Instruments Pvt. Ltd.


A-271 Okhla industrial Area, Phase-I, New Delhi -110 020
Tel: 681 3887 Fax: (91-11) 681 1833

You might also like