Professional Documents
Culture Documents
In the 1950s optical theodolites were invented. This instrument was equipped
with optical scales permitting directly digital readout or micrometer assissted
readouts.Electronic theodolites first appeared in the 1960s. This instrument
used photo electric converters capable of sensing horizontal and vertical angles
and displaying those in degrees minutes and seconds.
Jobs 3.3
Note : Before you use the instrument for the first time, check the job settings.
Measuring Distances 3.1
Sighting a prism reflector
Sight the telescope to see crosshairs at the center of the
prism reflector. When a reflected lightwave is detected, the signal
level is
indicated.
Measuring distances 31.2
To take a distance measurement, press [MSR1] or [MSR2] in the
Basic Measurement Screen (BMS) orin any observation screen.
While the instrument is taking a measurement, the prism constant
appears in a small font. If the average count is set to 0,
measurements are taken continuously until you press [MSR1],
[MSR2], or [ESC]. Each time a measurement is taken, the distance is
updated.
If the average count is set to a value from 1 to 99, the averaged
distance appears after the last shot. The field name SD changes to
SDx to indicate the averaged data.
Station Setup
There are seven procedures to setup a station in DTM 302 series
To open the Stn Setup menu, press [STN] in the BMS.
To select a command from this menu, press the corresponding
number key. Alternatively, press [<] or [>] to highlight the
command and then press [ENT]. The last function used is
highlighted.
(5) BS Check
(6) Base XYZ function:
The optical axis of the plummet must be aligned with the vertical
axis of the
instrument.
To check and adjust the optical plummet:
1. Place the instrument on the tripod. You do not have to level the
instrument.
2. Place a thick sheet of paper marked with an X on
the ground below the instrument.
While you are looking through the optical
plummet, adjust the leveling screws until the
image of the X is in the center of the reticle
mark .
3. Rotate the alidade 180°.
If the marked image is in the same position in
the center of the reticle mark, no adjustment is
required.
4. If the image is not in the same position,
adjust the optical plummet:
a. Use the supplied hexagonal wrench to
turn the adjustment screws until the
image of the X is in Position P. Position
P is the center point of the line
connecting the X and the center of the
reticle mark .
5.Centre and Check again