You are on page 1of 31

1

Our Energy Scorecard

1,30,000 employees in India


Total employees in India operations

28 million sq.ft.

Total built-up space of Infosys, across 10 locations

280 million units


Annual electricity consumption

~1 million units/day of consumption


Consumption per working day @ Infosys

Setting New Benchmarks: Being Unreasonable

Energy efficiency : 4X Improvement target over 2007 levels Carbon neutral Water neutral Waste Neutral Bio diversity : Sourcing energy from Green Utilities : Rain water harvesting and recycling : Organic nutrients should not leave our campus : Plant one native tree for every new employee

Lighting

AC

To make Infosys a global leader in environmental sustainability To be the trendsetter in the industry Work with best resources available globally To demonstrate the feasibility of cutting edge technologies to impact the society at large

Awareness

Renewable energy

Green Team

Water

Metering

Biodiversity

Landscape

In God We Trust: All Others Must Bring Data


Pune Sholinganalli Chandigarh Electronic city Hyderbad DC Mahindra City Mangala Mysore Nethra

1. Setting baseline 2. Data driven engineering

3. Performance based AMC Contracts


4. Field sensors 5. BMS system

So Far, So Good

Increased by 18%

23% improvement

Question all Assumptions

Promote interaction between design consultants


Building envelope performance as part of the architects contract

Day lighting criteria as part of architects contract

Performance criteria for HVAC consultant

Positive Disruption
Building envelope heat load not to exceed 1.0 W/ Sqft More than 75% of the office area to be naturally lit

as per LEED standards

Breaking the barrier.. > 550 Sqft per TR of AC area < 0.4 W/ Sqft for lighting design < 0.5 kW/TR for chiller plant design < 3.5 W/ Sqft for electrical design

>200% improvement in overall energy efficiency of new buildings

Existing buildings of Infosys New Design

Cutting edge design

10

80% of Occupied Space Should be Day Lit (3X)

Use of simulations to validate strategy

North South facing building with 16 m width to ensure 80% of spaces are day lit

11

Window Strategies: Maximize Day Light

Mysore SDB 5 building with above strategies

Bright day light without glare at SDB-5 Mysore

12

Light Up India!

2X reduction in the installed lighting load

~3X reduction in lighting energy consumption

13

Electrical Design & Operations

14

Cooling / Heating Strategy from Old Monuments

Thermal energy stored in thick walls and floors

Thermal mass cooled by flowing Yamuna water

15

Fundamentals of Physics and Heat transfer

16

Radiant Cooling Hyderabad Building

17

Innovative Cooling Technology Radiant Cooling

18

3X Reduction in Air-Conditioning Energy


Figures based on actual measured data in Hyderabad buildings for Mar Jul 2011

3X improvement in
efficiency compared to 2007 design Radiant cooling at no additional cost

19

Renewable energy: Making Green Power Competitive


Renewable energy at Infosys
One of the largest installation of solar water heater in the country @ 6 lakh litres/day Currently purchasing 60 million units of renewable power

Currently installing onsite Solar PV/Micro wind plants


R&D of Solar Thermal technology
Wind turbine at Mangalore

Helping drive Policy Level Changes


Succeeded in persuading Karnataka regulators for removing cross subsidy Karnataka has introduced voluntary Green Power Tariff Open access now allowed in Tamil Nadu
250 kw plant in Jaipur

20

Water Sustainability

Ajit Ninan
(Source: The Times Of India Group) BCCL

21

Impact of Water Efficiency Initiatives

Increased by 39%

6% improvement

6% efficiency improvement translates to saving of 235 million litres every year

22

Water Conservation: Mysore Case Study


Initiatives in Mysore campus:
Per capita fresh water consumption in Mysore campus
12.0 10.6 10.0

Reduction of 35%

Recycled water used for flushing in 2250 hostel rooms saving 2.5 lakh litres of fresh water everyday Flow restrictors installed in showers and taps in 10,000 hostel rooms saving 4 lakh litres of fresh water everyday Water leakage arresting and more efficient housekeeping practices in hostels saving about 3 lakh litres every day Mysore campus sources about 60% of its daily fresh water requirements from these dug wells

kilo litre/month

8.0 6.0 4.0 2.0 0.0 2007-08

6.9

2010-11

23

100% Water Sustainability by Rain Water Harvesting


Rain water harvesting 8 reservoirs built in Mysore total capacity 38 Million litres 7 reservoirs built in Mangalore total capacity 35 Million litres

3 reservoirs built in Pune potential capacity of 90 Million litres


4 reservoirs built in Hyderabad potential capacity of 130 Million litres

The amount of rain water sequestered in our Indian campuses is estimated at more than 4.3 Billion litres every year; which is about 123% of our annual water consumption

24

Rainwater Harvesting at Infosys Campus

25

Advanced Sewage Treatment Technology

STP with Membrane technology

Online monitoring of STP operations

26

Goals in Water efficiency


Current Consumption Per capita consumption for SDB Campus per capita water consumption 45 lts/day 65-70 lts/day New design standard 30 lts/day 45 lts/day

Water efficient fixtures:


Taps Shower heads Water Urinals EWCs <4 lts/min 6 lts/min 0.5 lts/flush 6/3 lts/flush (dual flush)

27

Biogas plant in Mysore campus Recycling food waste

Carbon footprint reduction of nearly 200 tons/year Biogas plants being built in all other campuses as well Goal - 100% recycling of organic waste within the campuses
Biogas plant in Mysore campus

28

Chemical Reduction Initiative


Standardized the usage of housekeeping chemicals in all campuses resulted in reduction of 75% in the number of chemicals used Chemical fertilizers used in landscaping has been replaced with organic manure

We will be using only Green seal chemicals for housekeeping going forward
We are in process of replacing all pesticides with organic substitutes Chemical free water treatment being tested and deployed for air conditioning water treatment

29

Experiences / Conclusions

Set unreasonable targets Question everything! Efficient buildings do not cost more, Measure and Monitor Seeing is believing!
but need a little effort

30

THANK YOU
www.infosys.com
The contents of this document are proprietary and confidential to Infosys Limited and may not be disclosed in whole or in part at any time, to any third party without the prior written consent of Infosys Limited. 2012 Infosys Limited. All rights reserved. Copyright in the whole and any part of this document belongs to Infosys Limited. This work may not be used, sold, transferred, adapted, abridged, copied or reproduced in whole or in part, in any manner or form, or in any media, without the prior written consent of Infosys Limited.