A DMM measures
AC / DC volts, AC / DC current Resistance
DMM may have a variety of special features that are designed for a wide number of applications.
Frequency Temperature Capacitance Continuity in circuit Diode check
http://www.fluke.com/fluke/inen/products/Thermometers.htm
Meaning
V DC
V mV A mA A k ))))
V AC millivolts (.001V or 1/1,000V) Amps milliamps (.001A or 1/1000A) microA (.000001A or 1/1,000,000A) Resistance (Ohms) kilo-Ohms, Megohms Continuity beeper
http://www.fluke.com/fluke/inen/products/Digital-Multimeters.htm
http://www.fluke.com/fluke/inen/products/Digital-Multimeters.htm
DMM Specifications
Display
Accuracy
Range & Resolution
Electronics
Electrical
DMMBASE1.PPT
20,000 count
Digits: 3 1/2, 4 1/2, etc. Example: 3 1/2: (read as three and half digit DMM) starting from the least significant digit (right most), 3 full digits from 0-9 Left most digit - 1 half digit (can read less than 9). Ex: 1999
Count: 3200, 4000, etc... 4000 count display reads from 0-3999 3200 count display reads from 0-3199
DMMBASE1.PPT
DMMBASE1.PPT
As the range increases, the resolution decreases: Range: 400.0mV Resolution: .1mV (=1/10 mV)
4.000V
40.00V 400.0V 1000V
.001V (=1mV)
.01V 0.1V 1V (=10mV) (=100mV) (=1000mV)
DMMBASE1.PPT
Plug the black test probe into the COM input jack. Plug the red test
probe into the V input jack.
If the DMM has manual ranging only, select the highest range so as not to overload the input.
Touch the probe tips to the circuit across a load or power source (in
parallel to the circuit).
http://www.fluke.com/fluke/inen/products/Digital-Multimeters.htm
Turn off power to the circuit. Select resistance (). Plug the black test probe into the COM input jack. Plug the red test probe into the input jack. Connect the probe tips across the component or portion of the circuit for which you want to determine resistance. View the reading, being sure to note the unit of measurement ohms (), kilohms(k), or megohms (M).
http://www.fluke.com/fluke/inen/products/Digital-Multimeters.htm
http://www.fluke.com/fluke/inen/products/Digital-Multimeters.htm
Power consumed in R1 is same for both AC and DC source if the VacRMS = Vdc.
DMMBASE1.PPT
DMMBASE1.PPT
DMMBASE1.PPT
Correct
Correct
Correct Correct
DMMBASE1.PPT
DMMBASE1.PPT
17
DMMBASE1.PPT
C.F. = 1.43
C.F. = 2.39
C.F. = 4.68
18
DMMBASE1.PPT
Crest Factor
Accurate for current waveforms with CF not exceeding 3 CF=3 at max range; CF=6 at half-range
DMMBASE1.PPT