Professional Documents
Culture Documents
IZBOR KABLOVA:
PREMA TRAJNO DOZVOLJENOJ STRUJI I PADU NAPONA - SRPS N.B2.752:1988
ZATITA OD STRUJE PREOPTEREENJA
IzIn
I2 =K*In
(A)
(A)
ItdIr
STRUJA POUZDANOG
DELOVANJA
ZATITNOG UREAJA
S
(mm2)
PODUNI INDUKTIVNI
OTPOR FAZNOG
PROVODNIKA
FAKTOR K
ZATITNOG UREAJA
Ir
(A)
(A)
(A)
(W/km)
(W/km)
(m)
(%)
(%)
DUINA KABLA
PODUNI OMSKI
OTPOR FAZNOG
PROVODNIKA
TRAJNO DOZVOLJENA
STRUJA
Kn
1.45 x Iz > I2
PRESEK FAZNOG
PROVODNIKA
(A)
RAUNSKA
VREDNOST STRUJNE
NOSIVOSTI KABLA
InIB
FAKTORI POLAGANJA
KABLOVA
IB
(A)
TIP RAZVODA
(SRPS N.B2.752)
cos
BROJ KABLOVA
(PARALELNO
VOENIH)
U
(V)
STRUJA ZATITNOG
UREAJA
Pj
(kW)
JEDNOVREMENA
STRUJA
DO
FAKTOR SNAGE
OD
NOMINALNI NAPON
REDNI BROJ
RELACIJA
POLAGANJA KABLA
JEDNOVREMENA
ELEKTRINA SNAGA
TS "Tigar 7"
RO-1
300
630
315.00
PP00 4x185
185
324
648.00
1.25
787.5
939.6
0.101
0.082
90
1.63
1.63
TS "Tigar 7"
RO-2
300
630
315.00
PP00 4x185
185
324
648.00
1.25
787.5
939.6
0.101
0.082
90
1.63
1.63
RO-1
PU1
14.1
25
25.00
PP00 5x4
31
31.00
1.35
33.75
45.0
4.565
0.115
0.20
1.83
RO-1
PU15
14.1
25
25.00
PP00 5x4
31
31.00
1.35
33.75
45.0
4.565
0.115
12
0.47
2.10
RO-1
PU52
4.6
400 0.90
7.38
10
10.00
PP00 5x2.5
2.5
23
23.00
1.35
13.5
33.4
7.274
0.118
10
0.21
1.84
RO-2
PU16
14.1
25
25.00
PP00 5x4
31
31.00
1.35
33.75
45.0
4.565
0.115
14
0.55
2.18
RO-2
PU36
14.1
25
25.00
PP00 5x4
31
31.00
1.35
33.75
45.0
4.565
0.115
0.20
1.83
PU1
PM1
10
80
1.00 125.00
125
125.00
PP00 1x50
50
141
141.00
1.35
168.75
204.5
0.387
0.087
0.02
1.85
PU15
PM15
10
80
1.00 125.00
125
125.00
PP00 1x50
50
141
141.00
1.35
168.75
204.5
0.387
0.087
10
0.02
2.12
PU16
PM16
10
80
1.00 125.00
125
125.00
PP00 1x50
50
148
148.00
1.35
168.75
214.6
0.387
0.087
25
0.06
2.24
10
PU36
PM36
10
80
1.00 125.00
125
125.00
PP00 1x50
50
148
148.00
1.35
168.75
214.6
0.387
0.087
20
0.04
1.87
Odgovorni projektant:
Strana 1 of 3
Tehniki proraun
PODUNI INDUKTIVNI
OTPOR FAZNOG
PROVODNIKA
PRETHODNI
INDUKTIVNI OTPORI
Xt+Xf
PODUNI INDUKTIVNI
OTPOR ZATITNOG
PROVODNIKA
PRETHODNI
INDUKTIVNI OTPOR
ZA[TITNIH
PROVODNIKA
STRUJA GREKE
NAPON DODIRA
Xn-1
Xn
xpe
Xn-1pe
Xn
Ig
Ug
tk
ti<tk
(W/km)
(W)
(W)
(W/km)
(W)
(W)
(W)
(A)
(V)
(sec)
(sec)
90
0.101
0.002160
0.006705
0.101
0.000000
0.009090
0.082
0.009360
0.013050
0.082
0.000000
0.007380
0.03
7666.67
89.77
5.0
0.01
90
0.101
0.002160
0.006705
0.101
0.000000
0.009090
0.082
0.013050
0.016740
0.082
0.000000
0.007380
0.03
7666.67
89.77
5.0
0.01
120
4.565
0.006705
0.029530
4.565
0.009090
0.031915
0.115
0.016740
0.017315
0.115
0.007380
0.007955
0.07
3285.71
108.07
5.0
0.01
RO-1
185
300
RO-2
185
120
PRESEK FAZNOG
PROVODNIKA
VREME DELOVANJA
ZATITNOG UREAJA
(W)
DOZVOLJENO
TRAJANJE KVARA
PRETHODNI OMSKI
OTPOR ZATITNIH
PROVODNIKA
SRpe
(W)
IMPENDANSA
PODUNI OMSKI
OTPOR ZATITNOG
PROVODNIKA
Rn-1pe
(W/km)
UKUPNI INDUKTIVNI
OTPOR PETLJE Xpe
rpe
(W)
UKUPNI INDUKTIVNI
OTPOR PETLJE Xt+Xf
PRETHODNI OMSKI
OTPOR Rt+Rf
S(Rt+Rf)
(W)
S
(mm2)
DO
DUINA KABLA
Rn-1
BROJ KABLOVA
(PARALELNO
VOENIH)
TS "Tigar
7"
TS "Tigar
7"
r
(W/km)
PRESEK ZATITNOG
PROVODNIKA
L
(m)
S
(mm2)
RELACIJA
POLAGANJA KABLA
REDNI BROJ
OD
PODUNI OMSKI
OTPOR FAZNOG
PROVODNIKA
RO-1
PU1
RO-1
PU15
120
12
4.565
0.006705
0.061485
4.565
0.009090
0.063870
0.115
0.013050
0.014430
0.115
0.007380
0.008760
0.13
1769.23
114.06
5.0
0.01
RO-1
PU52
2.5
95
10
4.565
0.006705
0.052355
4.565
0.009090
0.054740
0.115
0.013050
0.014200
0.115
0.007380
0.008530
0.11
2090.91
115.84
5.0
0.01
RO-2
PU16
50
14
4.565
0.006705
0.070615
4.565
0.009090
0.073000
0.115
0.013050
0.014660
0.115
0.007380
0.008990
0.15
1533.33
112.78
5.0
0.01
RO-2
PU36
50
4.565
0.006705
0.029530
0.722
0.009090
0.012700
0.115
0.013050
0.013625
0.093
0.007380
0.007845
0.05
4600.00
68.67
5.0
0.01
PU1
PM1
50
50
0.387
0.029530
0.032626
0.387
0.031915
0.035011
0.087
0.017315
0.018011
0.087
0.007955
0.008651
0.07
3285.71
118.50
5.0
0.01
PU15
PM15
50
35
10
0.387
0.061485
0.065355
0.387
0.063870
0.067740
0.087
0.014430
0.015300
0.087
0.008760
0.009630
0.14
1642.86
112.41
5.0
0.01
PU16
PM16
50
35
25
0.387
0.070615
0.080290
0.387
0.073000
0.082675
0.087
0.014660
0.016835
0.087
0.008990
0.011165
0.17
1352.94
112.87
5.0
0.01
10
PU36
PM36
50
20
0.387
0.029530
0.037270
0.387
0.012700
0.020440
0.087
0.013625
0.015365
0.087
0.007845
0.009585
0.06
3833.33
86.54
5.0
0.01
Odgovorni projektant:
Strana 2 of 3
Tehniki proraun
1
2
TS "Tigar
7"
TS "Tigar
7"
Rm+Rt
Xm+Xt
0.010064
0.0022304
Xn
Xn-1
SX
Ik"
Iud
In
SminS
(W)
(W)
(W)
(W)
(W)
(kA)
(kA)
(A)
(sec)
(kA)
(mm2)
MINIM. PRESEK
SR
(W)
VREME PREKIDANJA
Rn-1
STRUJA ZATITNOG
URE\AJA
Rn
(W)
UDARNA STRUJA
KRATKOG SPOJA
PRETHODNI
INDUKTIVNI OTPORI
x
(W/km)
STRUJA KRATKOG
SPOJA
INDUKTIVNI OTPOR
KABLA
r
(W/km)
IMPENDANSA
PRETHODNI OMSKI
OTPORI
L
(m)
UKUPNI INDUKTIVNI
OTPOR PETLJE
EF. VREDNOST
PROPUTENE STRUJE
KRATKOG SPOJA
0.000704
0.009360
PODUNI INDUKTIVNI
OTPOR FAZNOG
PROVODNIKA
PODUNI OMSKI
OTPOR FAZNOG
PROVODNIKA
S
(mm2)
DUINA KABLA
BROJ KABLOVA
(PARALELNO VO\ENIH)
DO
PRESEK FAZNOG
PROVODNIKA
KABL POLOEN
REDNI BROJ
OD
R
0.0000704
0.0021600
250
1000 kVA
S
Mrea 10 kV
Trafo
RO-1
185
90
0.101
0.082
0.0037
0.010064
0.013764
0.015321
15.07
26.55571
630
0.01
15.07
115
6.55
RO-2
185
90
0.101
0.082
0.0037
0.010064
0.013764
0.015321
15.07
26.55571
630
0.01
15.07
115
6.55
4.565
0.115
0.0006
0.013764
0.014364
0.032838
7.03
10.16119
25
0.01
7.03
115
3.17
RO-1
PU1
RO-1
PU15
12
4.565
0.115
0.0014
0.013764
0.015164
0.063371
3.64
5.250718
25
0.01
3.64
115
3.17
RO-1
PU52
2.5
10
7.274
0.118
0.0012
0.013764
0.014964
0.080827
2.86
4.125544
10
0.01
2.86
115
2.49
RO-2
PU16
14
4.565
0.115
0.0016
0.013764
0.015364
0.072282
3.19
4.601573
25
0.01
3.19
115
2.77
RO-2
PU36
4.565
0.115
0.0006
0.013764
0.014364
0.032838
7.03
10.16119
25
0.01
7.03
115
3.17
PU1
PM1
50
0.387
0.087
0.0007
0.013764
0.014464
0.035692
1.29
1.862879
125
0.01
1.29
115
1.12
PU15
PM15
50
10
0.387
0.087
0.0009
0.013764
0.014664
0.067053
0.69
0.995325
125
0.01
0.69
115
0.60
PU16
PM16
50
25
0.387
0.087
0.0022
0.013764
0.015964
0.081901
0.56
0.807799
125
0.01
0.56
115
0.49
10
PU36
PM36
50
20
0.387
0.087
0.0017
0.013764
0.015464
0.040314
1.15
1.660036
125
0.01
1.15
115
1.00
Odgovorni projektant:
Strana 3 of 3