You are on page 1of 31

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS

BMH-BPH

DMH-DPH

GENERAL DATA
Applications
Water circulator pump for community civil and industrial heating and air conditioning systems. All models
are available in both single and twin versions.

Construction features
Enbloc body composed of hydraulic section in cast iron and wet rotor motor.
Motor casing in aluminium. Flanged suction and discharge ports equipped with threaded fittings for pressure gauges. Rotor in technopolymer, motor shaft in hardened stainless steel held in graphite bearings lubricated by the pumping medium. Rotor protective jacket and stator jacket in stainless steel. Ceramic thrust
ring, ethylene propylene seals and brass air breather plug. Four-pole asynchronous motor for versions BMH
and DMH, two-pole motor for versions BPH and DPH. The Single-Phase Circulator is designed to operate at
three speeds at 230 V, while the Three-Phase Circulator is designed to operate at two speeds at 230 V and
at three speeds at 400 V. In both types, speed is adjusted on the basis of the setting of a selector on the terminal board in order to adapt circulator operation to the characteristics of the system.
Integral thermal in single-phase version. For the three-phase version the motor must be connected via an
external contactor. The contactor must be connected to the motor's integral thermal probe to protect it
against overload conditions at all speeds.
The twin version features an automatic swing check valve incorporated in the discharge port to avoid water
recirculating through the unit when it is not running; moreover, a blank flange is supplied as standard to
allow either of the two motors to be removed for servicing. Standard execution of the pump body is PN10,
which is compatible with PN6 counter-flanges for interchangeability of pumps in existing systems.
Circulator protection rating: IP 44 both single-phase and three-phase
Insulation class: H - Cable gland: PG 11
Standard voltage input: single-phase
230V, 50Hz
three-phase
230/400V, 50Hz
This product complies with European standard EN 60335-2-51
Designation index:
(example)

B P H 120 / 250 . 40 T
B =
D=
M=
P =
H=

single circulator
twin circulator
4-pole motor
2-pole motor
suitable for both air conditioning
and heating
maximum head (dm)
centre distance (mm)
(DN) nominal diameter
of flanged ports
M = single-phase motor
T = three-phase motor

48

DAB PUMPS reserves the right to make modications without notice.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


TECHNICAL DATA
N.
1
4
7A

PUMP BODY
IMPELLER
MOTOR SHAFT

7B
8
10
11

ROTOR
STATOR
MOTOR CASING
BREATHER PLUG

MATERIALS
CAST IRON 200 UNI ISO 185
TECHNOPOLYMER B
AISI 420 C Quenched and
Tempered STAINLESS STEEL

DIE CAST ALUMINIUM


BRASS
P Cu Zn 40 Pb2 UNI 5705

ETHYLENE PROPYLENE
(EPDM)
321 AISI Quenched and Tempered
STAINLESS STEEL AISI 304
321 AISI Quenched and Tempered
STAINLESS STEEL AISI 304
CAST IRON 200 UNI ISO 185
AISI 304 L
STAINLESS STEEL
CARBON EC 941

PARTS

100 TERMINAL BOX


127 SEAL RING
128 STATOR JACKET
129 ROTOR JACKET
130 CLOSING FLANGE
131 THRUST RING SUPPORT
132 BUSHINGS

Operating range:
Liquid temperature range:

Liquid quality requirements:

Maximum working pressure:


Standard flanging:
Minimum suction pressure:
Installation:

Special executions on request:


Accessories:

130

7A

127

100

132 131

7B

128 127 10 11

129

132

from 1.5 to 78 m3/h with head of up to 18 m.


For three-phase versions: from 10C to +120C
For models BPH DPH 150/340.65 T and BPH DPH 150/360.80 T;
BPH DPH 150-180/280.50 T; BPH DPH 180/340.65;
BPH DPH 180/360.80 T:
from 10C to +110C
For model BPH 120/280.50 M from -10 C to +90 C
For single-phase versions: from 10 C to +110 C
clean, free of solid contaminants and mineral oils, non-viscous,
chemically neutral, close to the properties of water.
(max. glycol contents 30%).
10 bar (1000 kPa)
DN 40, DN 50, DN 65, DN 80 in PN 6 / PN 10 (4 slots)
the values are given in the relative tables.
with HORIZONTAL MOTOR SHAFT on discharge or return pipe,
with suction port as close as possible to expansion vessel, above
boiler level and as far as possible from bends, elbows, and circuit
branches to avoid water turbulence with consequent noise.
alternative voltages and/or frequencies.
Flanging DN 80 in PN 10 / PN 16 (8 holes)
DN 40 - DN 50 - DN 65 - DN 80 threaded counter-flanges in PN 10.

TERMINAL BOARD POSITION


Single
DN 40-50-65-80

DAB PUMPS reserves the right to make modications without notice.

Twin
DN 65-80

DN 65-80

DN 40-50-65-80

49

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BMH 30/250.40 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

P
kPa

H
m

30

12

0
0

16

8
0,5

20

12

24

16

28

20

Q USgpm

24

Q IMPgpm
1,5 V m/s 40
H
400 V~ 50 Hz ft

10

8
20

2
6

4
10

1
2

0,4

0,8

20

1,2

40

60

80

0
Q m3/h

1,6

100

Q l/s

120

Q l/min

Hydraulic characteristics at 230 V are shown from page 50.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


L
B
H
m3
Kg

250

125

125

18

266

66

200

150

110

100

80

40

100

M10

221

83

138

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

2
1
3
2
1

3x230 V ~

BMH 30/250.40 T

250

ELECTRICAL DATA
P1 MAX
W
1340
100
1260
88
1440
192
1430
155
1260
88

DN 40 - PN 10

3x400 V ~

DMH 30/250.40 T

TWIN FLANGED - THREE-PHASE (1400 rpm)

0
0
P
kPa

H
m

30

20

16

24

32

16
1

75

90

m.c.a. 0.9

40

24

320 0,033 17,5

MINIMUM
SUCTION PRESSURE

In
A
0.48
0.39
0.78
0.58
0.23

rpm

SPEED

295

48

32

110 120

56

40

18

Q USgpm

48

Q IMPgpm
V m/s 40
H
400 V~ 50 Hz ft

10

4
10

1
2

0,8

40

1,6
80

10

12

2,4
120

160

0
Q m3/h

14

3,2

200

Q l/s

240

Q l/min

Hydraulic characteristics at 230 V are shown from page 50.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

105

145

18

271

66

205

150

110

100

80

40

200

100

100

100

M12

476

238

238

520

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 30/250.40 T

250
3x400 V ~

DN 40 - PN 10

SPEED
2
1
3
2
1

50

ELECTRICAL DATA
P1 MAX
W
100
1340
1260
88
1440
192
1430
155
1260
88
rpm

In
A
0.48
0.39
0.78
0.58
0.23

300

295 0,046

32

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 0.9

90
4

110 120

18

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +110C


10 bar (1000 kPa)

BPH 60/250.40 M
SINGLE FLANGED - SINGLE-PHASE (2800 rpm)

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

125

125

18

266

66

200

150

110

100

80

40

100

M10

221

83

138

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

250

DN 40 - PN 10

BPH 60/250.40 M

ELECTRICAL DATA
P1 MAX
W

1x230 V ~

320 0,033 17,5

MINIMUM
SUCTION PRESSURE

In
A

rpm

SPEED

295

3
2
1

2830
2750
2410

316
309
292

1.43
1.53
1.51

75

m.c.a. 1.6

90
4

110 120
14

DPH 60/250.40 M
TWIN FLANGED - SINGLE-PHASE (2800 rpm)

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

105

145

18

271

66

205

150

110

100

80

40

200

100

100

100

M12

476

238

238

520

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

250

DN 40 - PN 10

DPH 60/250.40 M
1x230 V ~

DAB PUMPS reserves the right to make modications without notice.

SPEED

ELECTRICAL DATA
P1 MAX
W

rpm

2830
2750
2410

316
309
292

1.43
1.53
1.51

295 0,046

32

MINIMUM
SUCTION PRESSURE

In
A

3
2
1

300

75

m.c.a. 1.6

90
4

110 120
14

51

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BPH 60/250.40 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)
P
kPa

10

0
0

10
0,5

20

30

40

20

50

30

1,5

Q USgpm

60

40

50

Q IMPgpm
V m/s 40
H
400 V~ 50 Hz ft

2,5

H
m
7

60

40

20

16

4
12
3
8

20

2
4

1
0

10

12

50

100

150

0
Q m3/h

14

4
200

Q l/s
250 Q l/min

Hydraulic characteristics at 230 V are shown from page 52.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

125

125

18

266

66

200

150

110

100

80

40

100

M10

221

83

138

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 60/250.40 T

250

ELECTRICAL DATA
P1 MAX
rpm
W
2570
253
2420
229
2850
348
2810
316
2430
232

DN 40 - PN 10

3x400 V ~

DPH 60/250.40 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

10

20

10

0
0

30
20

40

50

70

50
3

75

90

m.c.a. 1.6

60

40

320 0,033 17,5

MINIMUM
SUCTION PRESSURE

In
A
0.81
0.72
0.99
0.75
0.42

30

295

80

60

110 120

Q USgpm

90
70
4

19

80 Q IMPgpm
V m/s 40
H
400 V~ 50 Hz ft

P
kPa
70

H
m

60

20

50

16

40

30

20

10

12

10

50

100

12

14

3
150

16

4
200

18

20

250

22
6

300

0
Q m3/h
Q l/s

350

Q l/min

Hydraulic characteristics at 230 V are shown from page 52.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

105

145

18

271

66

205

150

110

100

80

40

200

100

100

100

M12

476

238

238

520

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 60/250.40 T

250
3x400 V ~

DN 40 - PN 10

SPEED
2
1
3
2
1

52

ELECTRICAL DATA
P1 MAX
rpm
W
253
2570
229
2420
348
2850
316
2810
2430
232

In
A
0.81
0.72
0.99
0.75
0.42

300

295 0,046

32

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 1.6

90
4

110 120

19

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +110C


10 bar (1000 kPa)

BPH 120/250.40 M
SINGLE FLANGED - SINGLE-PHASE (2800 rpm)
P
kPa

H
m

100

10

80

60

40

20

10

0
0

10
0,5

20

30

40

20

50

30

1,5

Q USgpm

60

40

50

Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft

2,5

30
25
20
15
10
5

10

12

50

14

100

0
Q m3/h
4

150

200

Q l/s
250 Q l/min

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

125

125

18

266

66

200

150

110

100

80

40

100

M10

221

83

138

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

FLANGES ON
REQUEST

250

DN 40 - PN 10

BPH 120/250.40 M

ELECTRICAL DATA
P1 MAX
W

1x230 V ~

3
2
1

2650
2320
1520

510
498
376

2.24
2.35
1.96

DPH 120/250.40 M

TWIN FLANGED - SINGLE-PHASE (2800 rpm)

20

0
0

40

80

110 120
18

Q USgpm

100

60

90
9

80

40

75

m.c.a. 6

60

20

320 0,033 17,5

MINIMUM
SUCTION PRESSURE

In
A

rpm

SPEED

295

Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft
5

P
kPa

H
m

100

10

80

25

60

20

40

20

30

15
10
5

4
1

0
0

50

12

16

100

150

4
200

20
5

250

300

350

400

PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

250

105

145

18

271

66

205

150

110

100

80

40

200

100

100

100

M12

476

238

238

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

250

DN 40 - PN 10

DPH 120/250.40 M
1x230 V ~

DAB PUMPS reserves the right to make modications without notice.

SPEED

ELECTRICAL DATA
P1 MAX
W

rpm

520

300

2650
2320
1520

510
498
376

2.24
2.35
1.96

Q l/s
Q l/min

VOLUME WEIGHT
m3
Kg

295 0,046

32

MINIMUM
SUCTION PRESSURE

In
A

3
2
1

0
Q m3/h

24

75

m.c.a. 6

90
9

110 120
18

53

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BPH 120/250.40 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)
P
kPa

H
m

100

10

80

60

40

20

10

0
0

10
0,5

20

30

40

20

50

30

1,5

Q USgpm

60

40

50

Q IMPgpm
V m/s 40
H
400 V~ 50 Hz ft

2,5

30
25
20
15
10
5
0

10

12

50

100

0
Q m3/h

14

150

200

Q l/s
250 Q l/min

Hydraulic characteristics at 230 V are shown from page 54.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

125

125

18

266

66

200

150

110

100

80

40

100

M10

221

83

138

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 120/250.40 T

250

ELECTRICAL DATA
P1 MAX
rpm
W
2300
395
2070
340
2780
536
2710
499
2080
339

DN 40 - PN 10

3x400 V ~

DPH 120/250.40 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

20

P
kPa

H
m

100

10

75

23

Q USgpm

100
80

110 120

80
60

90

m.c.a. 6

60
40

320 0,033 17,5

MINIMUM
SUCTION PRESSURE

In
A
1.2
1.07
1.16
0.98
0.62

40
20

0
0

295

Q IMPgpm
V m/s 40
H
400 V~ 50 Hz ft
5

30
80

25

60

20

40

20

15
10
5

0
50

12

16

100

150

4
200

20

250

300

0
Q m3/h

24

6
350

Q l/s

400

Q l/min

Hydraulic characteristics at 230 V are shown from page 54.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

250

105

145

18

271

66

205

150

110

100

80

40

200

100

100

100

M12

476

238

238

520

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 120/250.40 T

250
3x400 V ~

DN 40 - PN 10

SPEED
2
1
3
2
1

54

ELECTRICAL DATA
P1 MAX
rpm
W
395
2300
340
2070
536
2780
499
2710
339
2080

In
A
1.2
1.07
1.16
0.98
0.62

300

295 0,046

32

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 6

90
9

110 120

23

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BMH 30/280.50 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

10

0
0
P
kPa

H
m

30

20

20

30

10

40

20

50

30

0,5

Q USgpm

60

40
1,5

50

Q IMPgpm
2 V m/s 50
H
400 V~ 50 Hz ft

10

4
10

1
2

10

12

50

100

0
Q m3/h

14
4

150

200

Q l/s
250 Q l/min

Hydraulic characteristics at 230 V are shown from page 55.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

96

158

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

2
1
3
2
1

3x230 V ~

BMH 30/280.50 T

280

ELECTRICAL DATA
P1 MAX
W
1390
148
1340
134
1460
255
1450
216
1350
131

DN 50 - PN 10

3x400 V ~

DMH 30/280.50 T

TWIN FLANGED - THREE-PHASE (1400 rpm)

0
0
P
kPa

H
m

30

20

20

40

0,5

40
1,5

360

295

VOLUME WEIGHT
m3
Kg

320 0,033

75

90

m.c.a. 0.9

60

20

24

MINIMUM
SUCTION PRESSURE

In
A
0.7
0.55
1.12
0.83
0.32

rpm

SPEED

80

80
3

2,5

18

Q USgpm

100

60
2

110 120

Q IMPgpm
3,5 V m/s 50
H
400 V~ 50 Hz ft

10

4
10

1
2

4
1

0
0

50

12

16

100

150

4
200

20
5

250

300

0
Q m3/h

24
6

350

Q l/s

400

Q l/min

Hydraulic characteristics at 230 V are shown from page 55.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

305

73

232

165

125

110

90

50

240

120

120

120

M14

552

276

276

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 30/280.50 T

280
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 50 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
148
1390
134
1340
255
1460
216
1450
131
1350
rpm

In
A
0.7
0.55
1.12
0.83
0.32

590

335

VOLUME WEIGHT
m3
Kg

430 0,084 51,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 0.9

90
4

110 120

18

55

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BMH 60/280.50 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

10

0
0
P
kPa

H
m

50

40

20

10
0,5

30
20

40
30

50

60

40
1,5

70

50
2

80

Q USgpm

90

60
2,5

70

80 Q IMPgpm
V m/s 50
3
H
400 V~ 50 Hz ft
16

12
30

20

10

10

50

12

14

100

150

16

18

4
200

20

22

250

300

0
Q m3/h
Q l/s

350

Q l/min

Hydraulic characteristics at 230 V are shown from page 56.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

96

158

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BMH 60/280.50 T

280

ELECTRICAL DATA
P1 MAX
rpm
W
1210
272
1120
240
1400
410
1360
367
1130
235

DN 50 - PN 10

3x400 V ~

DMH 60/280.50 T

TWIN FLANGED - THREE-PHASE (1400 rpm)

20

P
kPa

H
m

50

40

40

20

0
0

60
40

360

295

80

100

320 0,033

75

90

m.c.a. 4

120

80

VOLUME WEIGHT
m3
Kg

24

MINIMUM
SUCTION PRESSURE

In
A
0.94
0.8
1.2
0.95
0.46

60
2

140

100
3

7.5

160

120
4

110 120

Q USgpm

180

140

21

160Q IMPgpm
V m/s 50
5
H
400 V~ 50 Hz ft
16

12
30

20

10

12

16

20

100

200

24

28

6
300

32

8
400

36

40

10

500

44
12

600

700

0
Q m3/h
Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 56.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

280

130

150

18

308

73

235

165

125

110

90

50

240

120

120

120

M14

556

278

278

590

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 60/280.50 T

280
3x400 V ~

DN 50 - PN 10

SPEED
2
1
3
2
1

56

ELECTRICAL DATA
P1 MAX
rpm
W
272
1210
240
1120
410
1400
367
1360
235
1130

In
A
0.94
0.8
1.2
0.95
0.46

335

430 0,084 44,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 4

90
7.5

110 120

21

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +110C


10 bar (1000 kPa)

BPH 60/280.50 M
SINGLE FLANGED - SINGLE-PHASE (2800 rpm)

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

156

158

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

280

DN 50 - PN 10

BPH 60/280.50 M

ELECTRICAL DATA
P1 MAX
W

1x230 V ~

320 0,033

24

MINIMUM
SUCTION PRESSURE

In
A

rpm

SPEED

295

3
2
1

2840
2730
2200

595
540
506

2.79
2.45
2.58

75

m.c.a. 1.6

90
6

110 120
14

DPH 60/280.50 M
TWIN FLANGED - SINGLE-PHASE (2800 rpm)

PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

308

73

235

165

125

110

90

50

240

120

120

120

M14

554

278

278

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

280

DN 50 - PN 10

DPH 60/280.50 M
1x230 V ~

DAB PUMPS reserves the right to make modications without notice.

SPEED

ELECTRICAL DATA
P1 MAX
W

rpm

590

335

2840
2730
2200

595
540
506

2.79
2.45
2.58

VOLUME WEIGHT
m3
Kg

430 0,084 44,5

MINIMUM
SUCTION PRESSURE

In
A

3
2
1

75

m.c.a. 1.6

90
6

110 120
14

57

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BPH 60/280.50 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

20

0
0
P
kPa
80

H
m
8

70

60

50

40

30

20

10

40

60

20

80

40
1

Q USgpm

100

60

80
3

Q IMPgpm
V m/s 50
H
400 V~ 50 Hz ft
25

20

15

10

0
0

12

50

16

100

150

20

4
200

250

0
Q m3/h

24

300

350

Q l/s

400

Q l/min

Hydraulic characteristics at 230 V are shown from page 58.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

156

158

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 60/280.50 T

280

ELECTRICAL DATA
P1 MAX
rpm
W
2670
464
2570
432
2890
589
2860
546
2570
423

DN 50 - PN 10

3x400 V ~

DPH 60/280.50 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

20

40

20

0
0

60
40

360

295

80

100
80
3

VOLUME WEIGHT
m3
Kg

320 0,033

24

MINIMUM
SUCTION PRESSURE

In
A
1.35
1.23
1.31
1.1
0.71

60

75

90

m.c.a. 1.6

120

140

100

160

120
5

19

Q USgpm

180

140

110 120

160Q IMPgpm
6 V m/s 50
H
400 V~ 50 Hz ft

P
kPa
80

H
m
8

70

60

20

50

16

40

30

20

10

24

12
8
4

12

16

20

100

200

24

28

6
300

32

8
400

36

40

10

500

44
12

600

700

0
Q m3/h
Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 58.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

308

73

235

165

125

110

90

50

240

120

120

120

M14

554

278

278

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 60/280.50 T

280
3x400 V ~

DN 50 - PN 10

SPEED
2
1
3
2
1

58

ELECTRICAL DATA
P1 MAX
rpm
W
464
2670
432
2570
589
2890
546
2860
423
2570

In
A
1.35
1.23
1.31
1.1
0.71

590

335

VOLUME WEIGHT
m3
Kg

430 0,084 44,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 1.6

90
6

110 120

19

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +90C


10 bar (1000 kPa)

BPH 120/280.50 M
SINGLE FLANGED - SINGLE-PHASE (2800 rpm)

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


Kg
m3
L
B
H

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

96

158

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

280

DN 50 - PN 10

SPEED

BPH 120/280.50 M

ELECTRICAL DATA
P1 MAX
rpm
W

1x230 V ~

295

320 0,033

24

MINIMUM
SUCTION PRESSURE

In
A

3
2
1

2690
2360
1340

870
800
590

3,97
3,69
3,12

75

m.c.a. 2

90
5

110 120

20

DPH 120/280.50 M
TWIN FLANGED - SINGLE-PHASE (2800 rpm)

PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

308

73

235

165

125

110

90

50

240

120

120

120

M14

556

278

278

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

280

DN 50 - PN 10

DPH 120/280.50 M
1x230 V ~

DAB PUMPS reserves the right to make modications without notice.

SPEED

rpm

ELECTRICAL DATA
P1 MAX
W

In
A

3
2
1

2690
2360
1340

870
800
590

3,97
3,69
3,12

590

335

VOLUME WEIGHT
m3
Kg

430 0,084 44,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

59

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BPH 120/280.50 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

20

0
0
P
kPa

H
m

100

10

40

60

20

80

40

100

60

Q USgpm

120

80
3

100

Q IMPgpm
4 V m/s 50
H
400 V~ 50 Hz ft
30

80

25

60

20

40

20

15
10
5

12

16

20

24

100

200

0
Q m3/h

28

300

Q l/s

400

500 Q l/min

Hydraulic characteristics at 230 V are shown from page 60.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

140

140

18

312

73

239

165

125

110

90

50

100

M10

254

96

158

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 120/280.50 T

280

ELECTRICAL DATA
P1 MAX
rpm
W
2430
683
2240
605
2810
898
2740
840
2260
603

DN 50 - PN 10

3x400 V ~

DPH 120/280.50 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

20

P
kPa

H
m

100

10

40

20

0
0

60

100

60

360

295

80
3

VOLUME WEIGHT
m3
Kg

320 0,033

26

MINIMUM
SUCTION PRESSURE

In
A
1.95
1.75
1.67
1.47
1

80

40

75

90

m.c.a. 2

120

140

100
4

160

120

110 120
20

Q USgpm

180

140
5

160Q IMPgpm
6 V m/s 50
H
400 V~ 50 Hz ft
30

80

25

60

20

40

20

15
10
5

12

16

20

100

24

28

200

300

32

8
400

36

40

10

500

44
12

600

700

0
Q m3/h
Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 60.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

308

73

235

165

125

110

90

50

240

120

120

120

M14

556

278

278

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 120/280.50 T

280
3x400 V ~

DN 50 - PN 10

SPEED
2
1
3
2
1

60

ELECTRICAL DATA
P1 MAX
rpm
W
683
2430
605
2240
898
2810
840
2740
2260
603

In
A
1.95
1.75
1.67
1.47
1

590

335

VOLUME WEIGHT
m3
Kg

430 0,084

49

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +110C


10 bar (1000 kPa)

BPH 150/280.50 T
SINGLE FLANGED - THREE-PHASE (2800 rpm

Hydraulic characteristics at 230 V are shown from page 61.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

140

140

18

362

73

289

165

125

110

90

50

100

M10

254

96

158

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 150/280.50 T

280

ELECTRICAL DATA
P1 MAX
rpm
W
2553
1130
2420
1032
2850
1470
2802
1360
2425
1030

DN 50 - PN 10

3x400 V ~

DPH 150/280.50 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

30

0
0

60

30

360

295

90

75

m.c.a. 2

120

150

90
2

320 0,033

26

MINIMUM
SUCTION PRESSURE

In
A
3.22
3
2.9
2.5
1.7

60

VOLUME WEIGHT
m3
Kg

110 120

180

120

90

Q USgpm

210

150

20

180

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft
45

H
m

P
kPa
140

14

120

12

100

10

80

25

60

20

40

20

40
35
30

15
10
5
0

0
0

12

2
100

16

20

24

28

200

300

32

8
400

36

40

44

10

500

600

0
52 Q m3/h

48

12

14

700

Q l/s

800

Q l/min

Hydraulic characteristics at 230 V are shown from page 61.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

358

73

285

165

125

110

90

50

240

120

120

120

M14

556

278

278

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 150/280.50 T

280
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 50 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
rpm
W
2553
1130
2420
1032
2850
1470
2802
1360
2425
1030

In
A
3.22
3
2.9
2.5
1.7

590

335

VOLUME WEIGHT
m3
Kg

430 0,084

49

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

61

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +110C


10 bar (1000 kPa)

BPH 180/280.50 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 62.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

280

140

140

18

362

73

289

165

125

110

90

50

100

M10

254

96

158

360

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 180/280.50 T

280

ELECTRICAL DATA
P1 MAX
rpm
W
2520
1230
2340
1120
2830
1630
2780
1540
2360
1130

DN 50 - PN 10

3x400 V ~

In
A
3,5
3,2
3
2,70
1,85

295

320 0,033

26

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

DPH 180/280.50 T
TWIN FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 62.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

280

130

150

18

358

73

285

165

125

110

90

50

240

120

120

120

M14

556

278

278

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 180/280.50 T

280
3x400 V ~

DN 50 - PN 10

SPEED
2
1
3
2
1

62

ELECTRICAL DATA
P1 MAX
rpm
W
1230
2520
2340
1120
2830
1630
2780
1540
2360
1130

In
A
3,5
3,2
3
2,70
1,85

590

335

VOLUME WEIGHT
m3
Kg

430 0,084

49

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BMH 30/340.65 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

10

0
0
P
kPa

H
m

30

20

10

30
20
0,5

40

50

30

60

40

70

50

80
70

Q USgpm

90

60

80 Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft

1,5

10

8
20

2
6

4
10

1
2

10

50

12

14

100

150

16

18

4
200

20

22

250

300

0
Q m3/h
Q l/s

350

Q l/min

Hydraulic characteristics at 230 V are shown from page 63.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


Kg
m3
L
B
H

340

170

170

18

334

82

252

185

145

130

110

65

100

M12

259

100

159

435

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BMH 30/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
1360
170
1310
154
1450
270
1430
233
1310
150

DN 65 - PN 10

3x400 V ~

DMH 30/340.65 T

TWIN FLANGED - THREE-PHASE (1400 rpm)

20

0
0
P
kPa

H
m

30

20

40

20
0,5

60
40

80

100

140

100

1,5

75

90

m.c.a. 4

120

80

400 0,051 27,5

MINIMUM
SUCTION PRESSURE

In
A
0.73
0.60
1.12
0.84
0.35

60

295

2,5

7.5

160

120

110 120
21

Q USgpm

180

140
3

160Q IMPgpm
3,5 V m/s 65
H
400 V~ 50 Hz ft

10

4
10

1
2

0
0

12

16

20

100

24

28

200

300

32

8
400

36

40

10

500

44
12

600

700

0
Q m3/h
Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 63.


PACK DIMENSIONS
L

L1

L2

340 138,5 201,5

MODEL

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

18

328

82

246

185

145

130

110

65

240

120

120

140

M14

476

238

238

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 30/340.65 T

340
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 65 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
170
1360
154
1310
270
1450
233
1430
150
1310
rpm

In
A
0.73
0.60
1.12
0.84
0.35

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

57

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 4

90
7.5

110 120
---

21

63

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from -10C to +120C


10 bar (1000 kPa)

BMH 60/340.65 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

20

0
0
P
kPa

H
m

50

40
20
0,5

60

80

40

100

60
1

Q USgpm

120

80

100

1,5

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft

10
40

30

20

10

10

12

16

20

24

100

200

0
Q m3/h

28

300

400

Q l/s
500 Q l/min

Hydraulic characteristics at 230 V are shown from page 64.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

340

170

170

18

334

82

252

185

145

130

110

65

100

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BMH 60/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
1170
295
1070
257
1380
445
1350
403
1090
255

DN 65 - PN 10

3x400 V ~

DMH 60/340.65 T

TWIN FLANGED - THREE-PHASE (1400 rpm)

20

0
0
P
kPa

H
m

50

40

40

20
0,5

435

295

80

100

60
1

75

140

100

1,5

400 0,051 27,5

90

m.c.a. 4

120

80

VOLUME WEIGHT
m3
Kg

MINIMUM
SUCTION PRESSURE

In
A
1
0.85
1.2
0.97
0.49

60
40

2,5

7.5

160

120

110 120
21

Q USgpm

180

140
3

160Q IMPgpm
V m/s 65
3,5
H
400 V~ 50 Hz ft
16

12
30

20

10

0
0

12

16

20

100

24

28

200

32

300

400

36

40

10

500

44
12

600

700

0
Q m3/h
Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 64.


L

L1

L2

340 138,5 201,5

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

18

331

82

249

185

145

130

110

65

240

120

120

140

M14

476

238

238

590

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 60/340.65 T

340
3x400 V ~

DN 65 - PN 10

SPEED
2
1
3
2
1

64

ELECTRICAL DATA
P1 MAX
rpm
W
295
1170
257
1070
445
1380
403
1350
255
1090

In
A
1
0.85
1.2
0.97
0.49

420

505 0,125

50

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 4

90
7.5

110 120

21

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +110C


10 bar (1000 kPa)

BPH 60/340.65 M
SINGLE FLANGED - SINGLE-PHASE (2800 rpm)

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


Kg
m3
L
B
H

340

170

170

18

334

82

252

185

145

130

110

65

100

M12

259

100

159

435

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

340

DN 65 - PN 10

SPEED

BPH 60/340.65 M

ELECTRICAL DATA
P1 MAX
rpm
W

1x230 V ~

295

400 0,051 27,5

MINIMUM
SUCTION PRESSURE

In
A

3
2
1

2780
2580
1460

735
685
564

3.37
3.13
3.12

75

m.c.a. 1

90
4

110 120
13

DPH 60/340.65 M
TWIN FLANGED - SINGLE-PHASE (2800 rpm)

PACK DIMENSIONS
L

L1

L2

340 138,5 201,5

MODEL

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

18

331

82

249

185

145

130

110

65

240

120

120

140

M14

476

238

238

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

340

DN 65 - PN 10

DPH 60/340.65 M
1x230 V ~

DAB PUMPS reserves the right to make modications without notice.

SPEED

rpm

ELECTRICAL DATA
P1 MAX
W

In
A

3
2
1

2780
2580
1460

735
685
564

3.37
3.13
3.12

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

50

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 1

90
4

110 120
13

65

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +120C


10 bar (1000 kPa)

BPH 60/340.65 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

20

0
0
P
kPa
70

H
m

60

50

40

30

20

10

40

20
0,5

60

80

40

100

60
1

120

80
1,5

160 Q USgpm

140

100

120

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft

2,5

7
20

15

10

12

16

100

20
5

200

24

28

300

400

32

36

0
Q m3/h

10

Q l/s

600

Q l/min

500

Hydraulic characteristics at 230 V are shown from page 66.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

340

170

170

18

334

82

252

185

145

130

110

65

100

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 60/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
2550
582
2380
532
2850
756
2800
705
2400
535

DN 65 - PN 10

3x400 V ~

DPH 60/340.65 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

40

0
0

435

295

120

75

m.c.a. 1

160

80

200

120

400 0,051 30,5

90

110 120

18

Q USgpm

240

160

VOLUME WEIGHT
m3
Kg

MINIMUM
SUCTION PRESSURE

In
A
1.67
1.53
1.5
1.3
0.9

80
40
1

200

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft

P
kPa
70

H
m

60

20

50

16

40

30

20

10

12

16

24

32

40

48

200

400

600

0
Q m3/h

56

12

16
800

Q l/s

1000 Q l/min

Hydraulic characteristics at 230 V are shown from page 66.


PACK DIMENSIONS
L

L1

L2

340 138,5 201,5

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

18

331

82

249

185

145

130

110

65

240

120

120

140

M14

476

238

238

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 60/340.65 T

340
3x400 V ~

DN 65 - PN 10

SPEED
2
1
3
2
1

66

ELECTRICAL DATA
P1 MAX
rpm
W
582
2550
532
2380
756
2850
705
2800
2400
535

In
A
1.67
1.53
1.5
1.3
0.9

590

420

VOLUME WEIGHT
m3
Kg

505 0,125 54,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 1

90
4

110 120

18

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +120C


10 bar (1000 kPa)

BPH 120/340.65 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

20

0
0
P
kPa

H
m

10

10

40

20
0,5

60

80

40

100

60
1

120

80

140

100

1,5

160

120

2,5

Q USgpm

180

140
3

160 Q IMPgpm
V m/s 65
3,5
H
400 V~ 50 Hz ft
35
30

25
20
15
10

12

16

20

100

24

28

200

300

32

36

8
400

40

44

10

500

12

600

0
Q m3/h
Q l/s

700

Q l/min

Hydraulic characteristics at 230 V are shown from page 67.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

340

170

170

18

384

82

302

185

145

130

110

65

100

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 120/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
2630
1001
2500
940
2880
1275
2830
1200
2520
934

DN 65 - PN 10

3x400 V ~

DPH 120/340.65 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

40

0
0

80

40
1

435

295

120

160

400 0,051 32,5

75

90

m.c.a. 6

200

120

VOLUME WEIGHT
Kg
m3

MINIMUM
SUCTION PRESSURE

In
A
2.85
2.66
2.64
2.25
1.52

80

240

160

280

200

110 120

22

320 Q USgpm

240

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft

P
kPa

H
m

100

10

80

25

60

20

40

20

30

15
10
5

0
0

16

4
200

24
6

32
8

400

40
10

48
12

600

56
14

64

16

800

18

1000

72

0
Q m3/h

20

Q l/s

1200

Q l/min

Hydraulic characteristics at 230 V are shown from page 67.


L

L1

L2

340 138,5 201,5

MODEL

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

18

381

82

299

185

145

130

110

65

240

120

120

140

M14

476

238

238

590

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 120/340.65 T

340
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 65 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
-1001
2630
940
2500
1275
2880
1200
2830
934
2520
rpm

In
A
2.85
2.66
2.64
2.25
1.52

420

505 0,125

59

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 6

90
9

110 120

22

67

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +110C


10 bar (1000 kPa)

BPH 150/340.65 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

30

0
0

60

90

30

120

60

150

90
2

180

120

Q USgpm

210

150

180

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft
45

H
m

P
kPa
140

14

120

12

100

10

80

25

60

20

40

20

40
35
30

15
10
5
0

12

16

20

100

24

28

200

300

32

36

8
400

40

44

10

500

0
52 Q m3/h

48

12

600

14

700

800

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 68.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

340

170

170

18

384

82

302

185

145

130

110

65

100

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 150/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
2410
1345
2250
1188
2800
1796
2730
1690
2250
1210

DN 65 - PN 10

3x400 V ~

DPH 150/340.65 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

40

0
0

80

40
1

435

295

120

160

400 0,051 32,5

75

90

m.c.a. 7

200

120

VOLUME WEIGHT
m3
Kg

MINIMUM
SUCTION PRESSURE

In
A
3.8
3.36
3.25
2.93
2

80

240

160

11

18

320 Q USgpm

280

200

110 120

240

Q IMPgpm
V m/s 65
H
400 V~ 50 Hz ft
45

H
m

P
kPa
140

14

120

12

100

10

80

25

60

20

40

20

40
35
30

15
10
5
0
0

16

4
200

24
6

32
8

400

40
10

48
12

600

56
14

64

16

800

18

1000

72

0
Q m3/h

20

Q l/s

1200

Q l/min

Hydraulic characteristics at 230 V are shown from page 68.


PACK DIMENSIONS
L

L1

L2

340 138,5 201,5

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

18

381

82

299

185

145

130

110

65

240

120

120

140

M14

476

238

238

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 150/340.65 T

340
3x400 V ~

DN 65 - PN 10

SPEED
2
1
3
2
1

68

ELECTRICAL DATA
P1 MAX
rpm
W
1345
2410
1188
2250
1796
2800
1690
2730
1210
2250

In
A
3.8
3.36
3.25
2.93
2

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

59

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +110C


10 bar (1000 kPa)

BPH 180/340.65 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 69.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

340

170

170

18

384

82

302

185

145

130

110

65

100

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 180/340.65 T

340

ELECTRICAL DATA
P1 MAX
rpm
W
2380
1670
2170
1490
2780
2310
2700
2210
2200
1490

DN 65 - PN 10

3x400 V ~

In
A
4,7
4,25
4
3,5
2,4

435

295

VOLUME WEIGHT
Kg
m3

400 0,051 32,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

DPH 180/340.65 T
TWIN FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 69.


PACK DIMENSIONS
L

L1

L2

340 138,5 201,5

MODEL

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

18

381

82

299

185

145

130

110

65

240

120

120

140

M14

476

238

238

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 180/340.65 T

340
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 65 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
1670
2380
1490
2170
2310
2780
2210
2700
1490
2200
rpm

In
A
4,7
4,25
4
3,5
2,4

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

59

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

69

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +120C


10 bar (1000 kPa)

BMH 30/360.80 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

20

0
0
P
kPa

H
m

40

40

20

60

80

40

100

60

0,5

120

80
1

160 Q USgpm

140

100
1,5

120

Q IMPgpm
V m/s 80
H
400 V~ 50 Hz ft
2

14
12

30

20

10
8

10

6
4

1
2

12

100

16

20

200

24

28

300

400

32

36

0
Q m3/h

10

Q l/s

600

Q l/min

500

Hydraulic characteristics at 230 V are shown from page 70.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

170

190

18

354

97

254

200

160

150

130

80

115

M12

297

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BMH 30/360.80 T

360

ELECTRICAL DATA
P1 MAX
rpm
W
1110
313
1010
268
1370
484
1330
437
1030
266

DN 80 - PN 10

3x400 V ~

DMH 30/360.80 T
TWIN FLANGED - THREE-PHASE (1400 rpm)
P
kPa

H
m

40

40

0
0

40
0,5

435

295

120

200

120

1,5

75

m.c.a. 4

160

80

400 0,051

31

MINIMUM
SUCTION PRESSURE

In
A
1.05
0.88
1.23
1
0.51

80

VOLUME WEIGHT
m3
Kg

110 120

7.5

21

Q USgpm

240

160
2,5

90

200
3

Q IMPgpm
V m/s 80
H
400 V~ 50 Hz ft
14
12

30

20

10
8
6
4

10

1
2

16

24

0
0

32

40

48

200

400

600

0
Q m3/h

56

12

16
800

Q l/s

1000 Q l/min

Hydraulic characteristics at 230 V are shown from page 70.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

160

200

18

345

97

248

200

160

150

130

80

240

120

120

150

M14

480

240

240

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 30/360.80 T

360
3x400 V ~

DN 80 - PN 10

SPEED
2
1
3
2
1

70

ELECTRICAL DATA
P1 MAX
rpm
W
313
1110
268
1010
484
1370
437
1330
1030
266

In
A
1.05
0.88
1.23
1
0.51

590

420

VOLUME WEIGHT
m3
Kg

505 0,125 54,5

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 4

90
7.5

110 120

21

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +120C


10 bar (1000 kPa)

BMH 60/360.80 T

SINGLE FLANGED - THREE-PHASE (1400 rpm)

40

0
0
P
kPa

H
m

50

40

80

120

40

160

80

0,5

1,5

Q USgpm

200

120

160
2,5

Q IMPgpm
V m/s 80
H
400 V~ 50 Hz ft
16

12
30

20

10

16

0
0

24

100

32

200

300

40

8
400

500

0
Q m3/h

48

10

12

600

14

700

800

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 71.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

170

190

18

404

97

307

200

160

150

130

80

115

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BMH 60/360.80 T

360

ELECTRICAL DATA
P1 MAX
rpm
W
1180
535
1100
465
1390
763
1350
663
1100
465

DN 80 - PN 10

3x400 V ~

DMH 60/360.80 T
TWIN FLANGED - THREE-PHASE (1400 rpm)
P
kPa

H
m

50

40

30

20

10

40

0
0

40
0,5

80

160
120

435

295

1,5

VOLUME WEIGHT
Kg
m3

400 0,051

40

MINIMUM
SUCTION PRESSURE

In
A
1.82
1.55
2.04
1.65
0.89

120
80

75

90

m.c.a. 2

110 120

200

240

280

160
2,5

200
3

240
3,5

20

320 Q USgpm
Q IMPgpm
4 V m/s 80
H
400 V~ 50 Hz ft
16

12

0
0

16

4
200

24
6

32
8

40
10

400

48
12

600

56
14

64

16

800

18

1000

72

0
Q m3/h

20

Q l/s

1200

Q l/min

Hydraulic characteristics at 230 V are shown from page 71.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

360

160

200

18

390

97

298

200

160

150

130

80

240

120

120

150

M14

480

240

240

590

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DMH 60/360.80 T

360
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 80 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
535
1180
465
1100
763
1390
675
1350
465
1100
rpm

In
A
1.82
1.55
2.04
1.65
0.89

420

505 0,125

72

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 2

90
5

110 120

20

71

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +120C


10 bar (1000 kPa)

BPH 120/360.80 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)
P
kPa

H
m

100

10

80

40

0
0

40
0,5

80

120

160

80

200

120

1,5

280 Q USgpm

240

160
2,5

200
3

Q IMPgpm
3,5 V m/s 80
H
400 V~ 50 Hz ft
32

24
60

40

20

16

10

20

30
6

200

40

10

400

50
12

600

0
Q m3/h

60

14

16

800

18

1000

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 72.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

360

170

190

18

404

97

307

200

160

150

130

80

115

M12

259

100

159

435

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 120/360.80 T

360

ELECTRICAL DATA
P1 MAX
rpm
W
2500
1410
2340
1292
2830
1820
2780
1710
2350
1302

DN 80 - PN 10

3x400 V ~

DPH 120/360.80 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

80

0
0
P
kPa

H
m

100

10

80

160

80

240

320

75

m.c.a. 6

400

240

400 0,051

40

MINIMUM
SUCTION PRESSURE

In
A
3.95
3.6
3.3
2.93
2.13

160

295

400
6

110 120

10

22

560 Q USgpm

480

320
5

90

Q IMPgpm
V m/s 80
H
400 V~ 50 Hz ft
7

32

24
60

40

20

16

0
0

20

40

60

12

400

80

16

800

20

100
24

1200

0
Q m3/h

120

28

32

1600

36

2000

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 72.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

160

200

18

390

97

298

200

160

150

130

80

240

120

120

150

M14

480

240

240

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 120/360.80 T

360
3x400 V ~

DN 80 - PN 10

SPEED
2
1
3
2
1

72

ELECTRICAL DATA
P1 MAX
rpm
W
1410
2500
1292
2340
1820
2830
1710
2780
1302
2350

In
A
3.95
3.6
3.3
2.93
2.13

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

72

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 6

90
10

110 120

22

DAB PUMPS reserves the right to make modications without notice.

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +110C


10 bar (1000 kPa)

BPH 150/360.80 T

SINGLE FLANGED - THREE-PHASE (2800 rpm)

40

0
0

80

40

120

160

80

200

120

240

160

320 Q USgpm

280

200
3

240

Q IMPgpm
4 V m/s 80
H
400 V~ 50 Hz ft

H
m

P
kPa
140

14

120

12

100

10

80

60

40

20

40

30

20

10

10

20

30

200

40

10

400

50
12

600

60

14

16

800

0
Q m3/h

70
18

20

1000

1200

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 73.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

170

190

18

404

97

307

200

160

150

130

80

115

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 150/360.80 T

360

ELECTRICAL DATA
P1 MAX
rpm
W
2140
1984
1900
1695
2710
2870
2610
2686
1940
1710

DN 80 - PN 10

3x400 V ~

DPH 150/360.80 T

TWIN FLANGED - THREE-PHASE (2800 rpm)

80

0
0

160

80

240

435

295

75

m.c.a. 7

320

400

14

120

12

100

10

80

60

40

20

400 0,051

90

40

400
6

110 120

11

18

560 Q USgpm

480

320
5

H
m

P
kPa
140

VOLUME WEIGHT
Kg
m3

MINIMUM
SUCTION PRESSURE

240

In
A
5.62
4.82
4.64
4.32
2.85

160

Q IMPgpm
V m/s 80
H
400 V~ 50 Hz ft
7

40

30

20

10

0
0

20

40

60

12

400

80

16

800

20

100
24

1200

0
Q m3/h

120

28

32

1600

36

2000

Q l/s
Q l/min

Hydraulic characteristics at 230 V are shown from page 73.


L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

PACK DIMENSIONS VOLUME WEIGHT


m3
Kg
L
B
H

360

160

200

18

390

97

298

200

160

150

130

80

240

120

120

150

M14

480

240

240

590

MODEL

POWER SUPPLY
50 Hz

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 150/360.80 T

360
3x400 V ~

DAB PUMPS reserves the right to make modications without notice.

DN 80 - PN 10

SPEED
2
1
3
2
1

ELECTRICAL DATA
P1 MAX
W
1984
2140
1695
1900
2870
2710
2686
2610
1710
1940
rpm

In
A
5.62
4.82
4.64
4.32
2.85

420

505 0,125

72

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

73

The performance curves are based on kinematic viscosity values = 1 mm2/s and density equivalent to 1000 kg/m3. Tolerance of curves to ISO 9906.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


Liquid temperature range:
Maximum working pressure:

from 10C to +110C


10 bar (1000 kPa)

BPH 180/360.80 T
SINGLE FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 74.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

170

190

18

404

97

307

200

160

150

130

80

115

M12

259

100

159

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

SPEED
2
1
3
2
1

3x230 V ~

BPH 180/360.80 T

360

ELECTRICAL DATA
P1 MAX
rpm
W
2380
1670
2170
1490
2780
2310
2700
2210
2200
1490

DN 80 - PN 10

3x400 V ~

In
A
4,7
4,25
4
3,5
2,4

435

295

VOLUME WEIGHT
m3
Kg

400 0,051

40

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

DPH 180/360.80 T
TWIN FLANGED - THREE-PHASE (2800 rpm)

Hydraulic characteristics at 230 V are shown from page 74.


PACK DIMENSIONS
L

L1

L2

B1

B2

D1

D2

D3

D4

I1

I2

I3

H1

H2

360

160

200

18

390

97

298

200

160

150

130

80

240

120

120

150

M14

480

240

240

POWER SUPPLY
50 Hz

MODEL

CENTRE
DISTANCE
mm

COUNTERFLANGES ON
REQUEST

3x230 V ~

DPH 180/360.80 T

360
3x400 V ~

DN 80 - PN 10

SPEED
2
1
3
2
1

74

ELECTRICAL DATA
P1 MAX
rpm
W
1670
2380
1490
2170
2310
2780
2210
2700
2200
1490

In
A
4,7
4,25
4
3,5
2,4

590

420

VOLUME WEIGHT
m3
Kg

505 0,125

72

MINIMUM
SUCTION PRESSURE
t

75

m.c.a. 7

90
11

110 120
18

DAB PUMPS reserves the right to make modications without notice.

CIRCULATORS FOR HEATING AND AIR CONDITIONING SYSTEMS


HYDRAULIC CHARACTERISTICS AT 230 V ~ 50Hz THREE-PHASE

BMH 30/250.40 T
0

0
0
P
kPa

H
m

30

DMH 30/250.40 T
12

16

8
0,5

20

12

24

16

28

20

Q USgpm

24

Q IMPgpm
1,5 V m/s 40
H
230 V~ 50 Hz ft

16

10

H
m

30

20

24

0
0
P
kPa

32

16
1

40

24

48

32

56

40

Q USgpm

48

Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft

10

8
20

2
6

4
10

10

0,4

0
0

0,8

20

1,2

40

1,6

60

80

Q
2

100

120

m3/h

Q l/min

BPH 60/250.40 T
0

10

0
0

10
0,5

30

40

20

50

30

1,5

60

40
2

50

Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft

2,5

10

1,6

40

20

10

12

2,4

80

16

20

10

0
0

40

4
0,8

Q USgpm

7
60

14

3,2

120

160

Q
4

200

240

Q l/min

30

40

20

50

30

60

40

70

50
3

80

60

90
70
4

Q USgpm

80 Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft

P
kPa
70

H
m

60

20

50

16

40

30

20

10

12

12
3

8
20

2
4

1
0

0
0

10

12

50

14

100

0
Q m3/h
4

150

200

P
kPa

H
m

100

10

10

0
0

10
0,5

250 Q l/min

Q l/s

BPH 120/250.40 T
0

10

12

50

14

100

150

16

18

4
200

20

250

0
Q m3/h

22

300

Q l/s

350

Q l/min

DPH 120/250.40 T

20

30

40

20

50

30

60

40

1,5

Q USgpm

50

Q IMPgpm
3 V m/s 40
H
230 V~ 50 Hz ft

2,5

20

0
0

40

60

20

80

40

100

60

80

Q USgpm

Q IMPgpm
V m/s 40
H
230 V~ 50 Hz ft
5

P
kPa

H
m

100

10

80

25

60

20

40

20

30

30
80

60

25
20

15

15
40

10

10
20

5
0

0
0

10

12

50

100

0
Q m3/h

14
4

150

200

10

P
kPa

H
m

30

20

12

50

16

100

20

150

200

250

0
Q m3/h

24
6

300

350

Q l/s

400

Q l/min

DMH 30/280.50 T

20

30

10

0
0

0
0

Q l/s
250 Q l/min

BMH 30/280.50 T
0

40

20

50

30

0,5

40
1,5

Q USgpm

60

50

Q IMPgpm
2 V m/s 50
H
230 V~ 50 Hz ft

20

10

P
kPa

H
m

30

20

40

60

20

0
0

0,5

40
1,5

80

Q USgpm

100

60
2

80
3

2,5

Q IMPgpm
3,5 V m/s 50
H
230 V~ 50 Hz ft

10

4
10

10

0
0

10

12

50

14

100

150

4
200

0
Q m3/h

10
10
0,5

0
0
P
kPa

H
m

50

40

30

20

10

20

30
20

Q l/s
250 Q l/min

BMH 60/280.50 T
0

12

50

16

100

150

20

4
200

250

0
Q m3/h

24
6

300

350

Q l/s

400

Q l/min

DMH 60/280.50 T
40

30

50

60

40
1,5

70

50
2

80

60
2,5

90
70

Q USgpm

80 Q IMPgpm
V m/s 50
H
230 V~ 50 Hz ft

20

P
kPa

H
m

50

40

30

20

10

40

20

0
0

16

60
40

80

100

60
2

120

80

140

100

160

120
4

140

180

Q USgpm

160Q IMPgpm
V m/s 50
5
H
230 V~ 50 Hz ft
16

12

12

0
50

10

2
100

0
/h

Q l/s

DPH 60/250.40 T

20

H
m

P
kPa

Q l/s

m3

12
3

150

14

16

4
200

250

DAB PUMPS reserves the right to make modications without notice.

18
5
300

20

22
6
350

0
Q m3/h

Q l/s

Q l/min

12

2
100

16

20

4
200

24
6

300

28

32

8
400

500

36
10
600

40

44
12
700

0
Q m3/h
Q l/s
Q l/min

75

BPH 60/280.50 T
0

20

0
0
P
kPa
80

H
m
8

70

60

50

40

30

20

10

DPH 60/280.50 T

40

60

20

80

40
1

Q USgpm

100

60

80
3

20

0
0

Q IMPgpm
V m/s 50
H
230 V~ 50 Hz ft
25

20

60
40

80

100

60

120

80
3

140

100

160

120
4

140
5

Q USgpm

180

160Q IMPgpm
6 V m/s 50
H
230 V~ 50 Hz ft

P
kPa
80
70

60

20

50

16

40

30

20

10

15

10

40

20

H
m
8

24

12
8

0
0

12

50

16

100

150

20

4
200

24

250

300

0
Q m3/h
7

350

400

20

Q l/min

12

16

20

100

24

28

200

300

32

8
400

36

40

44

10

500

12

600

60

80

40

100

60

Q USgpm

120

80
3

Q IMPgpm
4 V m/s 50
H
230 V~ 50 Hz ft

H
m

100

10

80

25

60

20

20

0
0

100

P
kPa

700

Q l/min

40

20

60
40

80

100

60

120

80
3

140

100

160

120
4

140
5

Q USgpm

180

160Q IMPgpm
6 V m/s 50
H
230 V~ 50 Hz ft

P
kPa

H
m

100

10

80

25

60

20

40

20

30

30

15

15
40

10

10
20

12

16

0
0

20

24

100

28

200

300

0
Q m3/h
8

400

500 Q l/min

12

16

Q l/s

20

100

200

300

DPH 150/280.50 T

BPH 180/280.50 T

DPH 180/280.50 T

BMH 30/340.65 T
10
10

0
0
P
kPa

H
m

30

20

30
20
0,5

24

28

BPH 150/280.50 T

32

8
400

36

40

44

10

500

12

600

700

Q l/min

DMH 30/340.65 T
40

50

30

60

40

70

50

80

60

90
70

1,5

Q USgpm

80 Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft

20

10

P
kPa

H
m

30

20

40

20
0,5

0
0

60
40

80

100

60
1

80
1,5

120

140

100

160

120

2,5

140
3

180

Q USgpm

160Q IMPgpm
3,5 V m/s 65
H
230 V~ 50 Hz ft

10

2
6

4
10

10

0
50

10

2
100

12
3

150

14

16

4
200

250

18
5
300

20

22
6
350

0
Q m3/h

Q l/s

Q l/min

76

0
Q m3/h
Q l/s

8
20

0
Q m3/h
Q l/s

DPH 120/280.50 T

40
20

Q l/s

BPH 120/280.50 T
0
0

12

2
100

16

20

4
200

24
6

300

28

32

8
400

500

36
10
600

40

44
12
700

0
Q m3/h
Q l/s
Q l/min

DAB PUMPS reserves the right to make modications without notice.

BMH 60/340.65 T
0

20

P
kPa

H
m

50

DMH 60/340.65 T

40

60

20
0,5

0
0

80

40

100

60
1

120

80

Q USgpm

100

1,5

Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft

20

P
kPa
50

40

30

20

10

40

60

20
0,5

0
0
H
m

80

40

100

60
1

120

80
1,5

140

100

160

120

180

140

2,5

Q USgpm

160Q IMPgpm
V m/s 65
3,5
H
230 V~ 50 Hz ft

16

10
40

30

20

12
10

8
5
10

12

16

0
0

20

24

100

200

0
Q m3/h

28

300

500 Q l/min

20

0
0
P
kPa
70

H
m

60

50

40

30

20

12

16

20

100

24

28

200

300

32

36

8
400

40

44

10

500

12

600

0
Q m3/h
Q l/s

700

Q l/min

DPH 60/340.65 T

40

60

20
0,5

BPH 60/340.65 T
0

0
0

Q l/s

400

80

40

100

60
1

120

80
1,5

160 Q USgpm

140

100

Q IMPgpm
3 V m/s 65
H
230 V~ 50 Hz ft

2,5

40

0
0

120

7
20

80

120

40
1

80

160

200

120

Q USgpm

240

160

200

Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft

P
kPa
70

H
m

60

20

50

16

40

30

20

10

15

10

12

8
5
10

12

16

100

20

24

200

300

28
7

32

36

0
Q m3/h

10

Q l/s

600

Q l/min

400

500

BPH 120/340.65 T
0

20

P
kPa

H
m

10

10

40

20
0,5

0
0

60

100

60
1

16

24

32

40

200

48

400

0
Q m3/h

56

12

16

600

800

1000 Q l/min

120

80
1,5

140

100

160

120

180

140

2,5

Q USgpm

160 Q IMPgpm
V m/s 65
3,5
H
230 V~ 50 Hz ft
35

40

80

40
1

0
0

120
80

160

200

120
2

240

160
3

280

200

320 Q USgpm

240

Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft

P
kPa

H
m

100

10

80

25

60

20

40

20

30

30
8

25
20

15

15
4

10

10
2

12

0
0

16

20

100

200

24

28

6
300

32

36

8
400

40

44

10

500

12

600

700

0
Q m3/h

30

60

30

0
0

14

120

12

100

10

0
0

Q l/min

16

24

32

200

40
10

400

48
12

600

56
14

64

16

800

18

1000

72

0
Q m3/h

20

Q l/s

1200

Q l/min

DPH 150/340.65 T

90
60

120

150

90
2

120

180

210

150

Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft
45

Q USgpm

180

40

40

80

40
1

0
0

H
m

P
kPa
140

Q l/s

BPH 150/340.65 T
0

Q l/s

DPH 120/340.65 T
80

40

120
80

160

200

120
2

240

160
3

280

200

Q IMPgpm
V m/s 65
H
230 V~ 50 Hz ft
45

H
m

P
kPa
140

14

120

12

100

10

320 Q USgpm

240

40

35

35

30

30

80

25

80

25

60

20

60

20

40

40

20

15

15

10
20

10

5
0
0
0

12

2
100

16

20

4
200

24
6

300

28

32

8
400

500

36

40

10
600

44
12
700

0
52 Q m3/h

48
14
800

Q l/s

Q l/min

BPH 180/340.65 T

DAB PUMPS reserves the right to make modications without notice.

5
0

16

4
200

24
6

32
8

400

40
10
600

48
12

56
14

800

64

16
1000

18

72

0
Q m3/h

20

Q l/s

1200

Q l/min

DPH 180/340.65 T

77

BMH 30/360.80 T
0

20

P
kPa

H
m

40

40

DMH 30/360.80 T

60

20

0
0

80

40

100

60

120

80

0,5

140

100
1,5

160 Q USgpm

120

Q IMPgpm
2 V m/s 80
H
230 V~ 50 Hz ft
14

P
kPa

H
m

40

30

20

40

80

0
0

40
0,5

120
80

160

200

120
1,5

Q USgpm

240

160
2,5

200
3

Q IMPgpm
V m/s 80
H
230 V~ 50 Hz ft
14
12

12
30

10

10
8

8
20

10

6
4

4
1

10

2
0

0
0

12

16

100

20

24

200

28

300

32

36

0
Q m3/h

10

Q l/s

600

Q l/min

400

500

BMH 60/360.80 T
P
kPa

H
m

50

40

30

20

10

40

0
0

0,5

16

24

32

40

48

200

400

0
Q m3/h

56

12

16

600

800

1000 Q l/min

DMH 60/360.80 T

80

120

40

160

80

200

120

1,5

160
2,5

Q USgpm

Q IMPgpm
V m/s 80
H
230 V~ 50 Hz ft
16

P
kPa

H
m

50

40

30

20

10

40

80

0
0

40
0,5

120

160

80

120
1,5

200

240

280

160
2,5

200
3

240
3,5

320 Q USgpm
Q IMPgpm
4 V m/s 80
H
ft

230 V~ 50 Hz

16

12

12

0
0

16

24

100

200

32

40

300

400

500

0
Q m3/h

48

10

12

600

14

700

800

P
kPa

H
m

100

10

80

60

40

20

40
40
0,5

80

0
0

Q l/min

16

24

32

200

40

10

400

48
12

600

56
14

64

16

800

18

1000

72

0
Q m3/h

20

Q l/s

1200

160

200

120
1,5

280 Q USgpm

240

160
2,5

200
3

Q IMPgpm
3,5 V m/s 80
H
230 V~ 50 Hz ft
32

P
kPa

H
m

100

10

80

60

40

20

80

0
0

160

80

240

320

160
2

400

240
3

560 Q USgpm

480

320
5

400
6

Q IMPgpm
V m/s 80
H
230 V~ 50 Hz ft
7

32

24

24

16

16

0
0

10

20

30
6

200

40

10

400

50
12

600

0
Q m3/h

60

14

16

800

18

1000

40

80

40

14

120

12

100

10

80

60

40

20

0
0

Q l/min

20
4

40
8

60

12

400

80

16

20

800

100
24

1200

0
Q m3/h

120

28

32

1600

36

2000

160

200

120

240

160

280

200
3

320 Q USgpm

240

Q IMPgpm
4 V m/s 80
H
230 V~ 50 Hz ft
40

20

80

0
0

160

80

240

320

160
2

400

240
3

480

320
5

400
6

H
m

P
kPa
140

14

120

12

100

10

80

60

40

20

30

Q l/min

560 Q USgpm
Q IMPgpm
V m/s 80
H
230 V~ 50 Hz ft
7

40

30

20

10

0
0
0

10

20

4
200

30

8
400

40
10
600

50
12

14
800

60
16
1000

70
18

20
1200

10

0
Q m3/h

Q l/s

Q l/min

BPH 180/360.80 T

20
4

40
8

400

60

12
800

16

80
20
1200

100
24

28
1600

0
Q m3/h

120
32
2000

36

Q l/s
Q l/min

DPH 180/360.80 T

78

Q l/s

DPH 150/360.80 T

120
80

H
m

P
kPa
140

Q l/s

BPH 150/360.80 T
0
0

Q l/min

DPH 120/360.80 T
120

80
1

Q l/s

BPH 120/360.80 T
0
0

Q l/s

DAB PUMPS reserves the right to make modications without notice.

You might also like