Professional Documents
Culture Documents
Design
Illuminance
(maintained)2,4,5
Fig.
B1
B8
B1
B1
B2
B3
B9
B8
B9
B8
50/30 FC
B2
(500/300 LUX)
B2
B3
B3
B3
B4
B6
B7A
B7A
B1
B2
B3
B2
B2
B3
30/20 FC
(300/200 LUX) B3
B4
B6
B6
B7A
B7A
70/50 FC
(700/500 LUX)
1.
2.
3.
4.
5.
6.
Poles
Outfield
330'F-400'C
325'F/380'C
330'F-400'C
330'F-400'C
330' Radius
330' Radius
325'F/380'C
325'F/380'C
310'F/350'C
310'F/350'C
300' Radius
300' Radius
300' Radius
300' Radius
300' Radius
250' Radius
200' Radius
200' Radius
180' Radius
330'F-400'C
330' Radius
330' Radius
300' Radius
300' Radius
300' Radius
300' Radius
250' Radius
200' Radius
180' Radius
200' Radius
180' Radius
Pole
2-A
Infield Total
2-B
2-C
2-D
Beam / Qty.6
Qty. / Pole
AX
BX
CX
DX
Total
10
9
8
9
6
8
9
8
8
8
6
6
8
6
6
5
4
4
5
4
4
6
5
4
4
4
3
2
2
4
3
17
16
8
10
8
10
10
12
9
8
8
8
8
8
8
6
4
6
6
6
4
5
5
6
4
3
3
-
10 10
12 10
8
6
11 6
6
8
11 4
6
10 4
6
4
4
4
4
6
8
8
5
3
7
5
6
4
4
3
6
3
3
2
3
6
5
4
3
2
4
4
-
42
44
32
36
28
28
34
28
30
26
22
18
22
28
28
10
4
12
4
18
14
18
12
8
16
20
14
4
4
6
4
18
10
2
12
4
4
6
2
4
2
2
2
2
2
2
2
2
-
34
40
26
12
24
20
22
26
22
22
20
24
20
14
14
22
18
8
16
20
20
18
18
20
12
10
8
12
10
10
10
94
94
60
60
52
52
60
60
54
52
44
44
44
44
44
32
22
22
20
40
34
36
30
28
30
30
22
16
14
16
14
Quantities and/or beam types subject to change based upon specific project requirements and product changes.
The following light loss factors were used for the maintained illuminance designs listed: 1500W Metal Halide 0.81
Recommended minimum mounting height (0.6 x setback) + 30, (Dimensions = Feet).
Specify the file number to obtain computer point-by-point printouts and/or aiming diagrams for specific designs listed.
Lamp position (TILT) effect included as applicable.
Illuminance levels not listed, such as TV, require special design considerations and should be directed to Hubbells Application Engineering Department.
Hubbell Lighting
363
Baseball Layouts
TECHNICAL
Baseball Layouts
Baseball Layouts
Fig.
B1
B8
B1
B1
B2
B3
B9
B8
B9
B8
50/30 FC
B2
(500/300 LUX)
B2
B3
B3
B3
B4
B6
B7A
B7A
B1
B2
B3
B2
B2
B3
30/20 FC
(300/200 LUX) B3
B4
B6
B6
B7A
B7A
70/50 FC
(700/500 LUX)
Poles
Outfield
330'F-400'C
325'F/380'C
330'F-400'C
330'F-400'C
330' Radius
330' Radius
325'F/380'C
325'F/380'C
310'F/350'C
310'F/350'C
300' Radius
300' Radius
300' Radius
300' Radius
300' Radius
250' Radius
200' Radius
200' Radius
180' Radius
330'F-400'C
330' Radius
330' Radius
300' Radius
300' Radius
300' Radius
300' Radius
250' Radius
200' Radius
180' Radius
200' Radius
180' Radius
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
75
60
60
60
90
90
90
90
90
90
90
75
60
60
60
60
2-B
2-C
2-D
File3
AX BX CX DX 2
12
12
10
12
10
10
12
12
10
8
8
8
10
8
8
6
4
5
7
5
6
6
6
5
6
5
4
3
3
3
3
18
17
10
12
10
12
12
12
12
12
8
9
8
10
10
8
5
8
6
8
5
6
6
6
5
3
2
-
X1
X2
Y1
Y2
B1
B2
B3
B4
B5
B6
B7A
B8
B9
90
90
90
75
60
60
60
90
90
30
30
30
25
20
20
20
30
30
25-50
25-50
25-50
20-40
15-40
15-40
15-40
25-50
25-50
135-165
135-165
135-165
110-145
110-160
110-160
135-165
135-165
40-80
40-80
40-80
35-65
25-50
25-50
25-50
40-80
40-80
30-60
30-60
30-60
25-45
20-30
20-30
30-60
30-60
TECHNICAL
Hubbell Lighting
364
6 Total
12 12 - 22 64 22 - 108
12 12 - 28 60 18 - 106
8 8 - 2 38 32 - 72
12 - - 16 46 10 - 72
6 6 - - 34 30 - 64
10 - - 8 30 26 - 64
12 - - 22 26 24 - 72
6 6 - 8 34 30 - 72
11 - - 10 30 26 - 66
6 6 - 6 26 32 - 64
6 5 - - 26 28 - 54
5 5 - 4 20 30 - 54
9
- - 6 24 24 - 54
10 - - 2 38 16 - 56
9
- - 8 32 14 - 54
6
- - 2 18 20 - 40
4
- - - 6 20 - 26
9
- - 6 12 10 - 28
5
- - - 12 12 - 24
6 5 - 4 24 20 - 48
5 4 - - 20 22 - 42
8
- - - 26 18 - 44
4 3 - - 18 18 - 36
4 3 - 2 12 22 - 36
6
- - 2 22 12 - 36
6
- - 4 20 10 - 34
4
- - - 16 10 - 26
3
- - - 6 10 2 18
3
- - - 2 10 4 16
6
- - - 10 8 - 18
5
- - 4 6 4 2 16
Figure
No.
Beam / Qty.
FIGURE B1
Baseball Layouts
FIGURE B2
FIGURE B7A
FIGURE B8
FIGURE B9
Hubbell Lighting
365
TECHNICAL
FIGURE B3