Table 4.19 shows result of a study about Y = whether a patient having surgery with general anesthesia experience a sore throat on waking (1 = yes) as a funcntion of D = duration of the surgery (in minutes) and T = type of device used to secure the airway (0 = laryngeal mask airway, 1 = tracheal tube). Data is following : Table 4.19 Data for problem 4.24 on Sore Throat after Surgery
D 45 15 40 83 90 25 35 65 95 35 75 45 50 75 30 25 20 60 70 30
T laryngeal mask airway laryngeal mask airway laryngeal mask airway tracheal tube tracheal tube tracheal tube laryngeal mask airway laryngeal mask airway laryngeal mask airway laryngeal mask airway laryngeal mask airway tracheal tube tracheal tube tracheal tube laryngeal mask airway laryngeal mask airway tracheal tube tracheal tube tracheal tube laryngeal mask airway
Y No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No Yes Yes Yes
60 61 65 15 20 45 15 25 15 30 40 15 135 20 40
laryngeal mask airway laryngeal mask airway laryngeal mask airway tracheal tube tracheal tube laryngeal mask airway tracheal tube laryngeal mask airway tracheal tube laryngeal mask airway laryngeal mask airway tracheal tube tracheal tube tracheal tube tracheal tube
KETERANGAN : 1. Variabel Y : wheter a patient having surgery with general anesthesia experience a sore throat on waking ( 1 : YES , 0 : NO) 2. Variabel X D : Duration of The Surgery T : Type of device ( 0 : laryngeal mask , 1 : tracheal mask ) Dengan menggunakan Rcmdr pada software R maka di dapat hasil sebagai berikut :
> summary(GLM.2)
Deviance Residuals: Min -2.3802 1Q -0.5358 Median 0.3047 3Q 0.7308 Max 1.7821
Coefficients: Estimate Std. Error z value Pr(>|z|) (Intercept) D T[T.tracheal tube] --Signif. codes: 0 '***' 0.001 '**' 0.01 '*' 0.05 '.' 0.1 ' ' 1 -1.41734 0.06868 -1.65895 1.09457 0.02641 0.92285 -1.295 2.600 -1.798 0.19536 0.00931 ** 0.07224 .
> Confint(GLM.2, level=.95, type="Wald") Estimate (Intercept) D T[T.tracheal tube] 97.5 % (Intercept) D T[T.tracheal tube] 2.070889 1.127996 1.161616 2.5 % -1.41734131 0.06867778 -1.65894910 97.5 % -3.56266059 0.01691278 -3.46771006 exp(Estimate) 0.7279780 0.1204428 0.1498119 2.5 % 0.2423575 1.0710910 0.1903389 0.02836326 1.01705661 0.03118837
( )
Keterangan dari model diatas : D= duration,T= tracheal Diperoleh nilai p-value dari variable durasi pembedahan (D) untuk model logistic biner ini sebesar 0.00931.Tolak H0 jika nilai alpha sebesar 5% yang artinya terdapat pengaruh durasi pembedahan terhadap kemauan pasien melakukan operasi karena sakit tenggorokan Sedangkan untuk variable jenis alat tracheal (T1) memperoleh nilai p-value sebesar 0.07224, maka akan diterima jika nilai alpha sebesar 5% artinya tidak terdapat pengaruh jenis alat pernafasan tracheal terhadap kemauan pasien melakukan operasi.
Kesimpulan : Peluang dia mengalami pengalaman anesthesia setelah operasi dengan menggunakan alat tracheal sebesar 0.19033x dibandingkan menggunakan alat laryngeal dengan mengabaikan durasi operasi. Jadi peluang pengamalan terkena penyakit anesthesia setelah operasi dengan mengabaikan alat yg digunakan setiap pertambahan 1 menit adalah sebesar 1.017 Untuk melihat interaksi bias menggunakan formula berikut : Call: glm(formula = Y ~ D + T + D * T, family = binomial(logit), data = Dataset)
Coefficients: Estimate Std. Error z value Pr(>|z|) (Intercept) D 0.04979 1.46940 0.034 0.9730 0.02848 0.03429 0.831 0.4062
T[T.tracheal tube] -4.47224 2.46707 -1.813 0.0699 . D:T[T.tracheal tube] 0.07460 0.05777 1.291 0.1966 --Signif. codes: 0 '***' 0.001 '**' 0.01 '*' 0.05 '.' 0.1 ' ' 1
Null deviance: 46.180 on 34 degrees of freedom Residual deviance: 28.321 on 31 degrees of freedom AIC: 36.321
Dengan interaksi antara durasi dan alat yang digunakan tracheal resiko pasien yang terkena pengalaman anesteshia sebesar 1.077453x dibanding apabila menggunakan laryngeal