You are on page 1of 1

1/2 F

1/2 F J 45^ 3

25

STAMP ON BOTH SIDES

10

150

H A

BLIND

NOMINAL PIPE SIZE


( in. )
2" 3" 4" 6" 8" 10" 12" 14" O.D. 16" O.D. 18" O.D. 20" O.D. 24" O.D.

A
( mm )
124 156 181 241 308 362 419 467 524 594 648 772

300 345 380 415 430 460 500 540 630

40 40 40 40 40 50 50 50 50

SEE NOTE-3

990
PLANT NO.

INDEX

AD-036467
DRAWING NUMBER

SHEET NO.

001

REV. NO.

04

NOTES:
1. BLINDS ARE TO BE MADE FROM STEEL PLATE ASTM A-202 GRADE A, A-302 GRADE A OR EQUAL WITH SPECIFIED MINIMUM YIELD STRENGTH OF 310.2 MPa. 2. THICKNESS "T" IS CALCULATED PER ANSI B31.3 PAR. 304.5.3 WITH P=31.0 MPa AND SE=279.2 MPa. 3. TOLERANCES: DIAMETERS "A" :+3mm, -0 THICKNESS "T": +1.5mm, -0.25mm FOR DIMENSIONS AND TOLERANCES OF RING JOINT GROOVES AND RINGS SEE ANSI B16.20 LATEST EDITION. 4. LIFTING EYE IS TO BE FORMED FROM STEEL ROD OF COMPOSITION SIMILAR TO THAT OF THE PLATE. COMMERCIAL STANDARD EYEBOLTS MAY BE USED IF THEY HAVE THE REQUIRED DIMENSIONS AND MATERIAL COMPOSITION. 5. WELDING SHALL BE 100% PENETRATION BY A PROCEDURE TO BE APPROVED BEFORE FABRICATION. 6. EDGES OF BLINDS TO BE FREE FROM ROUGH BURN FINISH AND BURRS. 7. STAMP SIZE, 3000 PSI AND GASKET RING NUMBER IN 8mm LETTERS WHERE INDICATED ON DRAWING. 8. FOR SPACERS SEE STANDARD DRAWING AD-036735.

115mm FOR 18" & 20" PIPE SIZE 140mm FOR 24" PIPE SIZE

TYP.

V/2 V

LIFTING EYE
FOR PIPE SIZES 18" AND UP

DRAWING RESPONSIBILITY:

PIPING STANDARDS COMMITTEE


EDSD

04

06-13-98 08-10-88 DATE

DMC

C
( mm )
215 230 255

F
( mm )
35 40 40

H
( mm )

J
( mm )
6 6 6 8 12 12 15 20 20 22 25 30

T
( mm )
29 33 37 44 54 62 70 79 87 100 106 127

V
( mm )
SEE NOTE-4

GASKET BLIND RING NO. MASS


R24 R31 R37 R45 R49 R53 R57 R62 R66 R70 R74 R78 3 5 8 16 32 52 77 113 150 218 277 467

03
REV. NO.

RLO
BY

MODIFY NOTE 1 & CHANGED MANDATORY DRAWING TO DRAWING RESPONSIBILITY. CONSOLIDATED SHTS.1 & 2 INTO SH. 1, METRIC VERSION ONLY. DESCRIPTION

ORIGL. ORIGL. ORIGL. SIGNED SIGNED SIGNED CHKD CERT. APPD

( kg. )
DRAWN BY

SAUDI ARABIAN OIL COMPANY


JF
CHECKED BY

12 15 15 20 20 20 25 25 25

HBM

SCALE

NONE

DATE STARTED OPRG DEPT.

07-27-74

DATE COMPLETED ENG DEPT.

07-31-74 DGB/ASB/CJW

APPD FOR CONSTR.


THIS DRAWING IS NOT TO BE USED FOR CONSTRUCTION OR FOR ORDERING MATERIAL UNTIL CERTIFIED AND DATED DATE CERTIFIED

BLINDS FOR API-3000 PSI RING JOINT FLANGES


STD. DWG.
PLANT NO. INDEX DRAWING NUMBER

METRIC
SHEET NO. REV. NO.

990
CopyrightSaudi Aramco 2009. All rights reserved.

AD-036467

001
A-2636

04
ENG.(03/87) CADD

You might also like