ADAIR SUPPLY

CORPUS CHRISTI, TX. 78409

DRILLING APPLICATION BIT HYDRAULICS & ECD


SEC 3 SEC 4 SEC 5 SEC 6 SEC 7

WELL GEOMETRY

SEC 1

SEC 2

Length, ft? = Hole Size, in? = Pipe OD, in? = Pipe ID, in? =
CONDITIONS

12,248 10.711 5 4.25

752 10.625 8 3
MUD PUMPS
PUMP - 1 PUMP - 2

3 Number of Jets in 1st Set? = 14 Size 1st Set of Jets, 32nds? = Number of Jets in 2nd Set? = Size 2nd Set of Jets, 32nds? = Reynolds Number PSI Drop MWD, Mud Motor? = Bit TVD, ft? = 13,000 Mud Weight, ppg? = 14.4 Plastic Viscosity? = 30.0 Yield Point? = 21
CALCULATIONS SEC 1

Liner Size, in? = Stroke Length, in? = Pump Rate, spm? = % Efficiency of Pump, (0 - 100)? = Rod Diameter, in? =
TRIPLEX, gpm
USER NOTES . . . .

6 12 115 95
481

A. Enter Well Geometry starting from top of hole in SEC 1 and continue to bit. B. Pump defaults to a TRIPLEX if Rod Size equals zero. C. Read comments in cell A35. SEC 2 SEC 3 SEC 4 SEC 5 SEC 6 SEC 7

Annular Velocity, fpm Critical Velocity, fpm Flow Type Annular Lag Times, minutes Drill Pipe Bore PSI Losses Annular PSI Losses

132
TURB

242
TURB

93 927 77

309
35

RESULTS - BIT HYDRAULICS and ECD

Total Pressure Losses for Sections Lag or Bottoms-Up Time Measured Depth Drill Bit ECD @ Bit Nozzle Area Surface Equipment Loss Bit Nozzle Pressure Drop
UPDATED MARCH 1995

1348 97 13,000 14.57 0.4510 268 1,511 THE END

Pump Pressure Nozzle Velocity Pump Hydraulic Horsepower Bit Hydraulic Horsepower Percent Horsepower @ Bit Bit HSI Impact Force
APPLICATION CREATED 1993

3,126 342 878 424 48.3 4.71 1,229