Professional Documents
Culture Documents
DC Generator: Vita Lystianingrum
DC Generator: Vita Lystianingrum
Vita Lystianingrum
REFERENCES
1. Theraja, B. L., Electrical Technology, S. Chand & Company Ltd., 1978. 2. Chapman, S. J, Electric Machinery Fundamentals, McGraw-Hill, 2005.
1: Energi dan permasalahannya | 2: Konsep konversi energi | 3: Pembangkitan energi listrik konvensional & non konvensional | 4: Dasar elektromagnetik, pengenalan bahan magnetik dan elektromekanik | 5: Mesin arus searah (DC) | 6: Generator DC: cara kerja, klasifikasi dan persamaan tegangan | 7: Generator DC: rugi-rugi daya dan efisiensi, efisiensi maksimum serta karakteristik | 8: | 9-10: Ujian Tengah Semester
|
DC GENERATOR
| | |
Emf induction Armature reaction Loaded generator Equivalent circuit: separately-excited; shunt; series; compound Voltage, power, current; Voltage control; Energy, losses, efficiency; Characteristics;
4
| |
Copper Losses
hysteresis
Total Losses
Iron/Magnetic Losses
Eddy current
Mechanical Losses
friction windage
Hysteresis Loss
This loss is due to the reversal of magnetism of the armature core. y (Every portion of the rotating core passes under N and S pole alternately, thereby attaining S and N polarity respectively. y Review: Hysteresis Loss
y
10
Copper Losses
hysteresis
Total Losses
Iron/Magnetic Losses
Eddy current
Mechanical Losses
friction windage
11
Copper Loss
Copper losses (Cu losses) .Armature copper loss = Ia2Ra .Field copper loss = If2Rf .Loss due to brush contact resistance; usually included in the armature copper loss.
12
Mechanical Loss
.Friction loss at bearings and commutator .Air-friction or windage loss of rotating armature
Poles Brushes Fan
13
Copper Losses
hysteresis
Total Losses
Iron/Magnetic Losses
Eddy current
Mechanical Losses
friction windage
Stray Losses: usually magnetic and mechanical losses are collectively known as Stray Losses. Constant Losses: Wc, consists of stray losses and shunt Cu losses. Variable Loss: varied with the load current -> armature Cu loss.
14
Copper Losses
15
E = cn
16
.If Ta is the torque exerted by the prime mover running at n rps, then the power developed is:
Ta 2n watt
.and the mechanical power converted into electrical power in the armature is:
E I a watt
then
Ta 2n = E I a
17
1 HP = 746 Watt.
18
Efficiency
A
Mechanical Power Input Iron and Friction Losses
B
Electrical Power developed in armature. EIa, Watt Copper Losses
C
Electrical Power Output VI, Watts
However if Ish is negligible as compared to load current, then Ia = I (approx.) 1 y = output / input =
Wc 1 + ( IRa + V VI )
d IRa Wc + =0 dI V VI
Ra Wc 2 =0 V VI
I 2 Ra = Wc
20
I 2 Ra = Wc
| |
Variable loss = constant loss. The load current corresponding to max efficiency is:
21
I=
Wc Ra
EXAMPLES
21-18 | 21-20 | 21-19
|
22