You are on page 1of 2

KBP201 THRU KBP207

Single Phase 2.0 AMPS. Silicon Bridge Rectifiers


Voltage Range 50 to 1000 Volts Current 2.0 Amperes

Features
.460(11.68) .420(10.6)

KBP

UL Recognized File # E-96005 Glass passivated junction Ideal for printed circuit board Reliable low cost construction technique results in inexpensive product High temperature soldering guaranteed: 260 / 10 seconds at 5 lbs. ( 2.3 Kg ) tension Small size, simple installation Leads solderable per MIL-STD-202, Method 208

AC .5 (12.7) MIN

.035(0.9) .028(0.7)

.160(4.1) SPACING .140(3.6)

.600(15.24) .560(14.22)

.153(3.9) .146(3.7)

.050(1.27)

Dimensions in inches and (millimeters)

Maximum Ratings and Electrical Characteristics


Rating at 25ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20% Symbol KBP KBP KBP Type Number
201 202 203 Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current @TA = 50 Peak Forward Surge Current, 8.3 ms Single Half Sine-wave Superimposed on Rated Load (JEDEC method ) Maximum Instantaneous Forward Voltage @ 2.0A Maximum DC Reverse Current @ TA=25 at Rated DC Blocking Voltage @ TA=125 Typical Thermal Resistance (Note) Operating Temperature Range Storage Temperature Range

KBP 204

KBP 205

KBP 206

KBP 207

Units V V V A A V uA uA /W

VRRM VRMS VDC I(AV) IFSM VF IR RJA RJL TJ

50 35 50

100 70 100

200 140 200

400 280 400 2.0 60 1.2

600 420 600

800 1000 560 700 800 1000

TSTG Note: Thermal Resistance from Junction to Ambient and from Junction to Lead Mounted on P.C.B. With 0.47 x 0.47 (12 x 12mm) Copper Pads.

10 500 25 8 -55 to +125 -55 to +150

- 668 -

RATINGS AND CHARACTERISTIC CURVES (KBP201 THRU KBP207)


FIG.1- MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT PER BRIDGE ELEMENT
2.0

60

FIG.2- MAXIMUM FORWARD CURRENT DERATING CURVE


AVERAGE FORWARD CURRENT. (A)

PEAK FORWARD SURGE CURRENT. (A)

50 40 30

1.5

1.0

20 10 0

0.5

10

20

40

60

100

20

40

60

80

100
o

120

140 150

NUMBER OF CYCLES AT 60Hz

AMBIENT TEMPERATURE. ( C)

FIG.3- TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS PER BRIDGE ELEMENT


10

FIG.4- TYPICAL REVERSE CHARACTERISTICS PER BRIDGE ELEMENT


100

INSTANTANEOUS FORWARD CURRENT. (A)

INSTANTANEOUS REVERSE CURRENT. ( A)

TJ=125 0C

10

0.1

1 TJ=25 0C

0.01 0.6

Tj=25 C PULSE WIDTH-300 S 1% DUTY CYCLE 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4

0.1 0

20

40

60

80

100

120

140

INSTANTANEOUS FORWARD VOLTAGE. (V)

PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)