UDS10 UDS100 User Guide: Part Number 900-360 Revision A June 2004
UDS10 UDS100 User Guide: Part Number 900-360 Revision A June 2004
Contacts
Lantronix 15353 Barranca Parkway Irvine, CA 92618, USA Phone: 949-453-3990 Fax: 949-453-3995 Technical Support Phone: 800-422-7044 or 949-453-7198 Fax: 949-450-7226 Online: www.lantronix.com/support Email: support@lantronix.com
Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix Web site at http://www.lantronix.com/about/contact/index.html
Contents
Contacts 1: Using This Guide 2 8
2: Introduction
Applications _______________________________________________________ Application Examples________________________________________________ Protocol Support ___________________________________________________ Additional Features _________________________________________________ Configuration Methods_______________________________________________ Product Information Label ____________________________________________
10
10 10 12 12 12 13
3: Getting Started
14
Installing the UDS __________________________________________________ 14 Required Information ________________________________________________ 15 Hardware Address_______________________________________________ 15 IP Address _____________________________________________________ 15 Assigning the IP Address and Related Network Settings ____________________ 16 DeviceInstaller __________________________________________________ 16 Serial Port Login ________________________________________________ 17
18
22
Using a Telnet Connection ________________________________________ 22 Using the Serial Port _____________________________________________ 23 Server Configuration (Network Configuration) _____________________________ 24 IP Address _____________________________________________________ 24 Set Gateway IP Address __________________________________________ 24 Netmask ______________________________________________________ 24 Change Telnet configuration password _______________________________ 25 DHCP Naming __________________________________________________ 25 Channel 1 Configuration (Serial Port Settings) ____________________________ 26 Baudrate ______________________________________________________ 26 I/F (Interface) Mode ______________________________________________ 26 Flow__________________________________________________________ 27 Port Number ___________________________________________________ 27 Connect Mode __________________________________________________ 28 Manual Connection ______________________________________________ 29
UDS10/UDS100 User Guide Remote IP Address ______________________________________________ Remote Port ___________________________________________________ Disconnect Mode _______________________________________________ Flush Mode ____________________________________________________ Pack Control ___________________________________________________ Disconnect Time (Inactivity Timeout) ________________________________ Send Characters ________________________________________________ Telnet Terminal Type ____________________________________________ Channel (Port) Password _________________________________________ Expert Settings ____________________________________________________ TCP Keepalive time in s __________________________________________ ARP Cache timeout in s __________________________________________ Security Settings ___________________________________________________ Disable SNMP__________________________________________________ SNMP Community Name _________________________________________ Disable Telnet Setup_____________________________________________ Disable TFTP Firmware Upgrade ___________________________________ Disable Port 77FE (Hex) __________________________________________ Disable Web Setup ______________________________________________ Disable ECHO Ports _____________________________________________ Enable Enhanced Password _______________________________________ Factory Default Settings _____________________________________________ Channel 1 Configuration Defaults ___________________________________ Expert Settings Defaults __________________________________________ Security Settings Defaults _________________________________________ Exit Configuration Mode _____________________________________________ 32 32 33 33 34 35 35 35 35 35 36 36 36 36 37 37 37 37 37 37 37 38 38 38 38 38
6: Updating Firmware
Obtaining Firmware _________________________________________________ Reloading Firmware ________________________________________________ Using DeviceInstaller ____________________________________________ Using TFTP____________________________________________________ Using Another Unit ______________________________________________ Using the Serial Port _____________________________________________
39
39 39 39 40 41 41
43
Entering Monitor Mode Using the Serial Port _____________________________ 43 Entering Monitor Mode Using the Network _______________________________ 43 Using Monitor Mode Commands _______________________________________ 44
45
LEDs ____________________________________________________________ 45 Problems and Error Messages ________________________________________ 46 Technical Support __________________________________________________ 49
51
Serial Port _____________________________________________________ 51 Serial Connector Pinouts _________________________________________ 51 Null-Modem Cable ______________________________________________ 53
55
57
57 57 58 58
59
Converting Binary to Hexadecimal______________________________________ 59 Conversion Table _______________________________________________ 59 Scientific Calculator ______________________________________________ 60 Connect Mode Options ______________________________________________ 61 Disconnect Mode Options ____________________________________________ 64 Flush Mode Options_________________________________________________ 66 Interface Mode Options ______________________________________________ 72 Pack Control Options ________________________________________________ 73
75 76 77
Figures
Figure 2-1. Application Examples ________________________________________ 11 Figure 2-2. Sample Ethernet Address _____________________________________ 13 Figure 3-1. UDS Connected to Serial Device and Network _____________________ 14 Figure 4-1. Web Browser Login __________________________________________ 18 Figure 4-2. UDS Configuration Guidelines Page _____________________________ 19 Figure 4-3. Lantronix Web Manager ______________________________________ 20 Figure 4-4. Server Properties Configuration on the Web Browser ________________ 21 Figure 5-1. Network Login Using Telnet____________________________________ 22 Figure 5-2. Setup Mode ________________________________________________ 23 Figure 5-3. Network Configuration ________________________________________ 24 Figure 5-4. Server Configuration Option ___________________________________ 26 Figure 5-5. Channel 1 Configuration ______________________________________ 26 Figure 5-6. Hostlist Option ______________________________________________ 30 Figure 5-7. Expert Settings Options _______________________________________ 35 Figure 5-8. Security Settings ____________________________________________ 36 Figure 6-1. TFTP Dialog Box ____________________________________________ 41 Figure 6-2. Sending Firmware to Another Unit_______________________________ 41 Figure 6-3. Firmware Upgrade Screen Display ______________________________ 42 Figure 7-1. Entering Monitor Mode Using the Network ________________________ 43 Figure 9-1. Serial Interface _____________________________________________ 51 Figure 9-2. DB25 Female DCE Interface RS232 _____________________________ 52 Figure 9-3. DB25 Female DCE Interface RS485/422 _________________________ 52
UDS10/UDS100 User Guide Figure 9-4. Null-Modem Cable (Lantronix Part No. 500-163) ___________________ 53 Figure 9-5. Network Interface ___________________________________________ 53 Figure 9-6. RJ45 Ethernet Connector _____________________________________ 54
Tables
Table 5-1. Standard IP Network Netmasks _________________________________ Table 5-2. Netmask Examples __________________________________________ Table 5-3. Interface Mode Options _______________________________________ Table 5-4. Common Interface Mode Settings _______________________________ Table 5-5. Flow Control Options _________________________________________ Table 5-6. Connect Mode Options________________________________________ Table 5-7. Manual Connection Address Example ____________________________ Table 5-8. Modem Mode Commands _____________________________________ Table 5-9. Disconnect Mode Options _____________________________________ Table 5-10. Flush Mode Options _________________________________________ Table 5-11. Pack Control Options ________________________________________ Table 7-1. Monitor Mode Commands _____________________________________ Table 7-2. Command Response Codes ___________________________________ Table 8-1. UDS10/UDS100 LEDs ________________________________________ Table 8-2. Problems and Error Messages __________________________________ 25 25 27 27 27 28 29 32 33 33 34 44 44 46 46
Chapter Summary
The remaining chapters in this guide include: 2: Introduction 3: Getting Started 4: Configuring the UDS Using Web Manager 5: Configuring the UDS Using Telnet or the Serial Port 6: Updating Firmware 7: Using Monitor Mode Describes the main features of the UDS and the protocols it supports. Provides information for installing your unit and getting it up and running. Provides instructions for accessing Web Manager and using it to configure settings for the UDS. Provides instructions for accessing Setup Mode (command line interface) using a Telnet connection through the network or a terminal or terminal emulation program through the serial port. Details the settings that you must configure. Provides instructions for obtaining the latest firmware and updating the UDS. Provides instructions for accessing and using the command line interface to monitor the network and diagnose problems. Describes common problems and error messages and how to contact Lantronix Technical Support. Provides descriptions and illustrations of connection hardware. Lists technical specifications for the UDS10 and the UDS100. Provides detailed information about using DHCP, AutoIP, BOOTP ARP, and Telnet to assign an IP address. Provides instructions on converting binary values to hexadecimals and tables listing all UDS configuration options in hexadecimal notation.
8: Troubleshooting and Contact Information 9: Connections and Pinouts 10: Technical Specifications A: Alternative Ways to Assign an IP Address B: Binary to Hexadecimal Conversions
Additional Documentation
The following information is available on the product CD or the Lantronix Web site:www.lantronix.com DeviceInstaller User Guide Provides instructions for using the Windows-based utility to configure the UDS and other Lantronix device servers. (CD and web site) Explain and demonstrate Assigning an IP address to the UDS and Setting up the UDS and the Redirector. See http://ts.lantronix.com/tutorials.html.
2: Introduction
The UDS10 and UDS100 are single-port device servers that provide a quick, simple, and cost-effective way to bring the advantages of data accessibility and remote management to devices not currently connected to a network. The main difference between the two models is that the UDS100 provides both half and full duplex 10/100 Ethernet data transfer, whereas the UDS10 provides only half duplex 10Base-T Ethernet. The technical specifications of the two products differ slightly as well. Unless otherwise noted, we refer to both products as the UDS.
Applications
The UDS family of Device Servers allows serial devices, such as those listed below, to connect and communicate over Ethernet networks using the IP protocol family (TCP for connection-oriented stream applications and UDP for datagram applications).
Security alarms Access control devices Fire control panels Time/attendance clocks and terminals ATM machines Data collection devices RFID readers Universal Power Supply (UPS) management units Telecommunications equipment Data display devices Virtually any asynchronous RS-232, RS422, or RS485 device.
Application Examples
Using a method called serial tunneling, the UDS encapsulates serial data into packets and transports them over Ethernet. Using two UDS units, connected by a network, virtual serial connections can extend across a facility or around the world. The Com Port Redirector software included on the product CD simplifies the integration process by extending the functionality of COM-port-based Windows applications. Virtual COM ports, mapped to remote device servers on the network, can replace direct serial connections.
10
Introduction
Note: For step-by-step instructions on configuring the UDS for serial tunneling or for use with the Com Port Redirector, access the UDS Configuration Tutorials using Web Manager. (See Accessing Web Manager on page 18.)
11
Introduction
Protocol Support
The UDS uses the Internet Protocol (IP) for network communications and the Transmission Control Protocol (TCP) to assure that no data is lost or duplicated and everything sent to the connection arrives correctly at the target. Supported protocols include:
ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, and SNMP for network communications. TCP, UDP, and Telnet for connections to the serial port. TFTP for firmware updates. IP for addressing, routing, and data block handling over the network. User Datagram Protocol (UDP) for typical datagram applications in which devices interact with other devices without a point-to-point connection.
Additional Features
Modem Emulation: In modem emulation mode, the UDS can replace dial-up modems. The unit accepts modem AT commands on the serial port, and then establishes a network connection to the end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines. Built-in Web Server: The UDS includes a built-in web server for configuring the unit and displaying operating and troubleshooting information on the attached links to online support.
Configuration Methods
After installation, the UDS requires configuration. For the unit to operate correctly on a network, it must have a unique IP address on the network. There are three basic methods for logging into the UDS and assigning IP addresses and other configurable settings: DeviceInstaller: Configure the IP address and other network settings on the UDS using a Graphical User Interface (GUI) on a PC attached to a network. (See DeviceInstaller on page 16.) Web Manager: Through a web interface configures the UDS settings using the Lantronix Web Manager. (See 4: Configuring the UDS Using Web Manager.) Serial and Telnet Ports: There are two approaches to accessing Setup Mode: making a Telnet connection to the network port (9999) or connecting a terminal (or a PC running a terminal emulation program) to the units serial port. (See 5: Configuring the UDS Using Telnet or the Serial Port.)
12
Introduction
Bar code Serial number Product ID (name) Product description Hardware address (also referred to as the Ethernet or MAC address)
The first three bytes of the hardware address are fixed and read 00-20-4A, identifying the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique numbers assigned to each unit.
Figure 2-2. Sample Hardware Address 00-20-4A-14-01-18 or 00:20:4A:14:01:18
13
3: Getting Started
This chapter describes how to get your UDS up and running in the shortest possible time.
To install the unit, complete the following steps in order. Refer to the numbers in the figure above. 1. Connect a serial device to your unit. See 9: Connections and Pinouts for more information about the device attachments the unit supports. 2. Connect an Ethernet cable to the RJ45 port. 3. Supply power to your unit using the power supply that was included in the packaging. Note: The required input voltage is 9-30 VDC or 9-24 VAC (1 W maximum). 4. Supply power to the serial device. Note: If you encounter a problem, please see LEDs on page 45 for diagnostic information.
14
Getting Started
Required Information
Before configuring the UDS, have the following information available:
Hardware Address
Take note of the units hardware address (also known as the Ethernet or MAC address). It is on the product label, in the format: 00-20-4a-XX-XX-XX, where the XXs are unique numbers assigned to the product (see Product Information Label on page13). Hardware Address: 00-20-4a-_____-_____-_____
IP Address
The UDS must have a unique IP address on your network. This address references the specific unit. By default, the device is DHCP-enabled and automatically assigned an IP address on DHCP-enabled networks. If you are assigning a static IP address, the systems administrator generally provides the IP address, subnet mask, and gateway. Note: The factory default IP address is 0.0.0.0 to enable DHCP, BOOTP, and AutoIP. When the units boots, it sends a DHCP broadcast to try and get an IP address. If it receives no reply from a DHCP server, the UDS tries BOOTP. If the UDS does not receive a response from BOOTP, it reverts to an AutoIP address.
IP Address:
_______
_______
_______
_______
_______
_______
_______
_______
_______
_______
You have several options for assigning an IP to your unit. This chapter provides information about using the DeviceInstaller (graphical user interface) and serial port login (command line interface) methods. Note: For information about other methods of assigning the IP address, such as DHCP, AutoIP, ARP, and Telnet, see A: Alternative Ways to Assign an IP Address.
15
Getting Started
DeviceInstaller
Note: The DeviceInstaller User Guide and the DeviceInstaller online help provide more detailed information on using DeviceInstaller. Installing DeviceInstaller To use the DeviceInstaller utility, you first install it from the product CD. 1. Insert the product CD into your CD-ROM drive. The Lantronix UDS10/UDS100 DeviceInstaller window displays. 2. If the CD does not launch automatically: a) Click the Start button on the Task Bar and select Run. b) Enter your CD drive letter, colon, backslash, deviceinstaller.exe (e.g., E:\deviceinstaller.exe). 3. Click the DeviceInstaller button. 4. Respond to the installation wizard prompts. (When prompted to select an installation type, select Typical.) Assigning the IP Address and Network Class 1. Click the Start button on the Task Bar and select Programs Lantronix DeviceInstaller DeviceInstaller. The DeviceInstaller window displays. 2. Click the Assign IP icon. The Assign IP Address window displays. 3. Enter the hardware (Ethernet) address of the device. 4. Select Assign a specific IP address to assign a static IP address to the device or select Obtain an IP address automatically to enable BOOTP, DHCP, or Auto IP on the device. 5. Click Next. 6. Enter an IP address, subnet mask, and gateway for the device. Enter this information in XXX.XXX.XXX.XXX format. 7. Click Next. 8. Click the Assign button to finalize the IP assignment.
16
Getting Started
Adding the Unit to the Manage List Now add the unit to the list of similar Lantronix devices on the network so that you can manage and configure it. To perform this step, click the Search icon. DeviceInstaller locates the unit and adds it to the list. Now you can manage (configure) the unit so that it works with the serial device on the network. Methods of Configuring the UDS Now that the UDS has an IP address and other initial settings, you can configure it further by several methods. Note: To assign Expert settings and Security settings, you must use the Setup Mode window in a Telnet session.
To configure the unit using a Web browser, click the Web icon. The Lantronix Web Manager window displays in your browser. Continue with 4: Configuring the UDS Using Web Manager. To configure the unit using a Telnet session or the serial port, click the Telnet icon. The Setup Mode window displays. Continue with 5: Configuring the UDS Using Telnet or the Serial Port.
Continue with 5: Configuring the UDS Using Telnet or the Serial Port. Select 9 to save and exit Setup Mode. The unit performs a power reset.
17
Note: You can also access Web Manager by clicking the Web icon on the DeviceInstaller Manage List window (see Methods of Configuring the UDS on page 17.) 2. When the UDS Configuration Guidelines Page displays, select one of the four links:
18
UDS settings opens a configuration window to configure the UDS10/UDS100, as shown in Figure 4-3. Serial cabling lets you view pinouts for the UDS serial port. View UDS Configuration Tutorials provides step-by-step instructions for configuring serial tunneling and the Com Port Redirector. Technical Support lets you download the latest firmware for your UDS and view documentation.
19
2. Use the menu (pushbuttons) to navigate to sub pages where you can configure server settings. Note: For detailed explanations of the settings, see 5: Configuring the UDS Using Telnet or the Serial Port. 3. When you are finished, click the Update Settings button to save your settings.
Example
For example, to enter server properties: 1. Click the Server Properties button. The Server Properties section of the Web page displays. 2. Confirm or enter values for
20
3. In the Telnet Password field, enter a password to prevent unauthorized access to the Setup Mode using a Telnet connection to port 9999. The password is limited to 4 characters. (An enhanced password setting of 16 characters is available under Security Settings in Setup Mode.) Note: No password is required to access the Setup Mode window using a serial connection. 4. Click the Update Settings button.
21
Note: Be sure to include a space between the IP address and 9999. 2. Click OK. To remain in Setup Mode, you must press Enter within 5 seconds. The current configuration settings display, followed by the Change Setup menu.
22
3. Select an option on the Change Setup menu by entering the number of the option in the Your choice ? prompt and pressing Enter. 4. To enter a value for a parameter, type the value and press Enter. To confirm a current value, just press Enter. 5. When you are finished, save the new configurations (option 9). The unit reboots.
23
2. Type three lowercase x characters (xxx) within one second after powering up to start the configuration mode. Note: The easiest way to enter Setup Mode is to hold down the x key on your keyboard while powering up the unit. The configuration settings display, followed by the Change Setup menu. 3. Select an option on the menu by entering the number of the option in the Your choice ? prompt and pressing Enter. 4. To enter a value for a parameter, type the value and press Enter. To confirm a default value, just press Enter. 5. When you are finished, save the new configuration (option 9). The unit reboots.
IP Address
The IP address must be set to a unique value in your network. If the IP address has not been assigned by DHCP, enter it manually. Enter each octet, pressing Enter after each. See A: Alternative Ways to Assign an IP Address for more information about IP addressing.
Netmask
A netmask defines the number of bits taken from the IP address that are assigned for the host section. The host section is the part of the IP address that is specific to the UDS.
24
Note: Class A: 24 bits; Class B: 16 bits; Class C: 8 bits. The unit prompts for the number of host bits to enter, then calculates the netmask, which displays in standard decimal-dot notation when the saved parameters display (for example, 255.255.255.0).
Table 5-1. Standard IP Network Netmasks
Netmask
255.255.255.252 255.255.255.248 255.255.255.240 255.255.255.224 255.255.255.192 255.255.255.128 255.255.255.0 255.255.254.0 255.255.252.0 255.255.248.0 ... 255.128.0.0 255.0.0.0
Host Bits
2 3 4 5 6 7 8 9 10 11 ... 23 24
DHCP Naming
A DHCP name is a unique identifier used for managing multiple DHCP hosts on a network. Your unit ships with a default DHCP name of Cxxxxxx, where xxxxxx is the last six digits of the Mac address. You can change the DHCP name (up to eight characters) when configuring the server in Setup Mode. Change the DHCP name to LTXdd, where 0.0.0.dd is the IP address assigned (dd should be a number between 1 and 99). For example, if the IP address is set to 0.0.0.5, the resulting DHCP name is LTX05.
25
If you give the unit an IP of 0.0.0.0, you then have the option to assign an 8-character DHCP name.
Figure 5-4. Server Configuration Option
Change DHCP device name (LTRX) ? (N) Y Enter new DHCP device name : LTRXYES
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200, 2400, 4800, 9600 (default), 19200, 38400, 57600, and 115200 bits per second.
26
The following table demonstrates how to build some common Interface Mode settings:
Table 5-4. Common Interface Mode Settings
Binary
0100 1100 0111 1000 0100 1111 0101 1101
Hex
4C 78 4F 5D
Flow
Flow control sets the local handshake method for stopping serial input/output. Use the following table to select flow control options:
Table 5-5. Flow Control Options
Hex
00 01 02 05
Port Number
Every TCP connection and every UDP datagram has a destination IP address and a port number. A port number is similar to an extension on a PBX system. For example, a Telnet application commonly uses port number 23. Port number 9999 is reserved for access to the unit's Setup Mode. The Port Number setting represents the source port number in TCP connections. It is the number that identifies the channel for remote initiating connections. For example, to send data to channel 1, send TCP/UDP packets to this assigned port number. The default setting for port 1 is 10001. The range is 1-65535, except for the following reserved port numbers:
27
Port Numbers
1 1024 9999 30718
Reserved for
Reserved (well known ports) Telnet setup Reserved (77FEh)
Warning: We recommend that you not use the reserved port numbers for this setting as incorrect operation may result. Use port 0 for the outgoing local port to change with each connection. The port range is 50,000 to 59,999. Each subsequent connection increments the number by 1. (When the port number reaches 59999, it wraps around to 50000.) Only use the automatic port increment feature to initiate a connection using TCP. Set the port to a non-zero value when the unit is in a passive mode or when you are using UDP instead of TCP.
Connect Mode
Connect Mode defines how the unit makes a connection, and how it reacts to incoming connections over the network. Enter Connect Mode options in hexadecimal notation. Note: To look up hex values, see B: Binary to Hexadecimal.
Table 5-6. Connect Mode Options
Bit 7 6 5 4 3 2 1 0
0 0 0 0 1 0 1 1 0 0 1 0 0 0 0 0 0 0 0 1 0 1 1 0 0 1 0 1 1 0 0 0 1 1 0 1 0 1 1 1 0 0 0 0 1 1 0 0 1 1 0 0 0 1 0 1 0 1
28
Manual Connection
The UDS attempts to connect when directed by a command string received from the serial port. The first character of the command string must be a C (ASCII 0x43), and the last character must be either a carriage return (ASCII 0x0D) or a line feed (0x0A). No spaces may be in the command string. Between the first and last command string characters must be a full or partial destination IP address and can include a destination port number. The IP address must be in standard dot-decimal notation and may be a partial address, representing the least significant 1, 2, or 3 bytes of the remote IP address. A period is required between each pair of IP address numbers. If present, the port number must follow the IP address, must be a decimal number in the range 1-65535, and must be preceded by a forward slash (ASCII 0x2F). The slash separates the IP address and the port number. If you omit the port number from a command string, the internally stored remote port number becomes the destination port number when the connection attempt is made. If the command string includes a partial IP address, the UDS interprets it to be the least significant bytes of the IP address and uses the internally stored remote IP address to provide the most significant bytes of the IP address. If the IP address entered is 0.0.0.0/0, the device server enters Monitor Mode. For example, if the remote IP address already configured in the unit is 129.1.2.3, then an example command string would be C3/7. (This would connect to 129.1.2.3 and port 7.) You may also use a different ending for the connection string. For example, C50.1/23 would connect you to 129.1.50.1 and port 23.
Table 5-7. Manual Connection Address Example
Command String
C121.2.4.5/1 C5 C28.10/12
Autostart (Automatic Connection): If you enable autostart, the unit automatically connects to the remote IP address and remote port specified. Datagram Type: When selecting this option, you will be prompted for the datagram type. Enter 01 for directed or broadcast UDP. Hostlist: If you enable this option, the Lantronix unit scrolls through the hostlist until it connects to a device listed in the hostlist table. Once it connects, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until it connects to another IP in the hostlist.
29
To use the hostlist option, follow these steps: 1. To enable the hostlist, enter a Connect Mode of 0x20 (2X). The menu shows you a list of current entries already defined in the product. 2. To delete, modify, or add an entry, select Yes. If you enter an IP address of 0.0.0.0, that entry and all others after it are deleted. 3. After completing the hostlist, repeat the previous step if necessary to edit the hostlist again. 4. For Retrycounter, enter the number of times the Lantronix unit should try to make a good network connection to a hostlist entry that it has successfully ARPed. 5. For Retrytimeout, enter the number of seconds the unit should wait before failing an attempted connection. Modem (Emulation) Mode: In Modem Mode, the unit presents a modem interface to the attached serial device. It accepts AT-style modem commands, and handles the modem signals correctly. Normally there is a modem connected to a local PC and a modem connected to a remote machine. A user must dial from the local PC to the remote machine,
30
accumulating phone charges for each connection. Modem Mode allows you to replace modems with UDS units, and to use an Ethernet connection instead of a phone call. By not having to change communications applications, you avoid potentially expensive phone calls. To select Modem Mode, set the Connect Mode to C6 (no echo), D6 (echo with full verbose), or D7 (echo with 1-character response). Note: If the unit is in Modem Mode and the serial port is idle, the unit still accepts network TCP connections to the serial port if Connect Mode is set to C6 (no echo), D6 (echo with full verbose), or D7 (echo with 1-character response).
Echo: Refers to the echo of all of the characters entered in command mode; it does not mean to echo data that is transferred. Quiet Mode (no echo) refers to the modem not sending an answer to the commands received (or displaying what was typed). Full Verbose: The unit echoes modem commands and responds to a command with a message string. 1-Character Response: The unit echoes modem commands and responds to a command with a single character response.
There must be a 1-second guardtime (no data traffic) before sending +++. There must not be a break longer than 1 second between +s. There must be another 1-second guardtime after the last + is sent.
2. When the unit acknowledges with an OK to indicate that it is in command mode, enter ATH and press Enter. The command is echoed if echo is enabled. ATH is acknowledged by another OK.
31
Function
ATDTx.x.x.x,pppp Makes a connection to an IP address (x.x.x.x) and a remote port number or (pppp). ATDTx.x.x.x/pppp Makes a connection to an IP address (x.x.x.x) and the remote port number ATDTx.x.x.x defined within the unit. Forces the unit into Monitor Mode if a remote IP address and port number ATD0.0.0.0 are defined within the unit. Forces the unit into Monitor Mode if a remote IP address and port number ATD are not defined within the unit. Makes a connection to an IP address (x.x.x.x) and the remote port number ATDx.x.x.x defined within the unit. Hangs up the connection (Entered as +++ATH ). ATH ATDTx.x.x.x,pppp Makes a connection to an IP address (x.x.x.x) and a remote port number or (pppp). ATDTx.x.x.x/pppp Enables or disables connections from the network going to the serial port: n=0 disables the ability to make a connection from the network to the serial port. ATS0=n n=1-9 enables the ability to make a connection from the network to the serial port. n>1-9 is invalid. ATEn ATVn Enables or disables character echo and responses: n=0 disables character echo and responses. n=1 enables character echo and responses. Enables 1-character response or full verbose: n=0 enables 1-character response. n=1 enables full verbose.
Note: The unit only recognizes these AT commands as single commands like ATE0 or ATV. It does not recognize compound commands such as ATE0V1. All other AT commands with Modem Mode set to full verbose acknowledge with an OK, but the unit takes no action.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote Port
The remote TCP port number must be set for the unit to make outgoing connections. This parameter defines the port number on the target host to which a connection is attempted. Note: To connect an ASCII terminal to a host using the unit for login purposes, use the remote port number 23 (Internet standard port number for Telnet services).
32
Disconnect Mode
This option determines the conditions under which the unit causes a network connection to terminate. In DisConnMode, DTR drop either drops the connection or is ignored. Note: To look up hex values, see B: Binary to Hexadecimal.
Table 5-9. Disconnect Mode Options
Bit 7 6 5 4 3 2 1 0
1 0 1 1 0 1 1 1
1. The UDS sends the "Terminal Type" upon an outgoing connection. 2. A password is required for a connection to the serial port from the network. 3. The TCP connection closes even if the remote site does not acknowledge the disconnection. 4. When there is a network connection to or from the serial port, the state LED turns off instead of blinking. 5. When Ctrl D or Hex 04 are detected, the connection is dropped. Both Telnet mode and Disconnect with EOT must be enabled for Disconnect with EOT to function properly. Ctrl D is only be detected going from the serial port to the network.
Flush Mode
Flush Mode (buffer flushing) controls line handling and network buffers with connection startup and disconnect. You can select between two different packing algorithms. Note: To look up hex values, see B: Binary to Hexadecimal. Available Flush Mode options are:
Table 5-10. Flush Mode Options
Function
Input Buffer (Serial to Network) Clear with active connection (from serial) Clear with passive connection (from network) Clear with disconnect Output Buffer (Network to Serial) Clear with active connection (from serial) Clear with passive connection (from network) Clear with disconnect Alternate Packing Algorithm (Pack Control) Enable
Bit 7 6 5 4 3 2 1 0
1 1 1 1 1 1 1
33
Pack Control
Two firmware-selectable packing algorithms define how and when the unit sends packets to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting settings in this mode can economize the network data stream. Pack control settings are enabled in Flush Mode. Set Pack Control to 00 if specific functions are not needed. Note: To look up hex values, see B: Binary to Hexadecimal.
Table 5-11. Pack Control Options
Option
Idle Time Force transmit: 12ms Force transmit: 52ms Force transmit: 250ms Force transmit: 5sec Trailing Characters None One Two Send Characters 2-Byte Send Character Sequence Send Immediately After Send chars
Bit 7 6 5 4 3 2 1 0
0 0 1 1 0 0 0 1 1 0 1 1 0 1 0 1
Idle Time: Idle time to "Force transmit" defines how long the unit waits before sending accumulated characters. This wait period is between characters. If there is an idle period between characters equal to the force transmit set, the UDS packages the serial data currently in the buffer and sends it to the network. Trailing Characters: In some applications, CRC, Checksum, or other trailing characters follow the end-of-sequence character. This option helps to adapt frame transmission to the frame boundary. Send Characters:
If 2-Byte Send Character Sequence is enabled, the unit interprets the sendchars as a 2-byte sequence. If this option is not enabled, the unit interprets them independently. If Send Immediately After Send Characters is not set, any characters already in the serial buffer are included in the transmission after the unit finds a "transmit" condition. With this option, the unit sends immediately after recognizing the transmit condition (sendchar or timeout).
Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent.
34
Send Characters
Enter up to two characters in hexadecimal representation for the SendChar settings. If the unit receives a character on the serial line that matches one of these characters, it sends the character immediately, along with any awaiting characters, to the TCP connection. This action minimizes the response time for specific protocol characters on the serial line (for example, ETX, EOT). Setting the first SendChar to 00 disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control on page 34).
Expert Settings
Note: Change these settings using Telnet or serial connections only, not Web Manager. Caution: Only an expert should change these parameters. These changes have serious consequences.
Figure 5-7. Expert Settings Options
35
Security Settings
Change these settings using Telnet or serial connections only, not Web Manager. Note: We recommend that you set security over the dedicated network or over the serial setup. If you set security over the network (Telnet 9999), someone else could capture these settings. Caution: Disabling both Telnet Setup and Port 77FE prevents users from accessing the Setup Mode from the network.
Figure 5-8. Security Settings
Disable SNMP
This setting disables the SNMP protocol on the unit to prevent SNMP management software from communicating with the UDS.
36
37
To save all changes and reboot, select 9. All values are stored in nonvolatile memory. To exit the configuration mode without saving changes or rebooting, select 8.
38
6: Updating Firmware
This chapter explains how to obtain and update the units firmware.
Obtaining Firmware
Obtain the most up-to-date firmware and release notes for the unit from the Lantronix Web site (http://www.lantronix.com/) or by using anonymous FTP (ftp://ftp.lantronix.com/).
Reloading Firmware
There are several ways to update the unit's internal operational code. Use DeviceInstaller (the preferred way), TFTP, another unit, or the serial port. Another option is to use the unit's internal web interface (CBXW*.COB) using TFTP or DeviceInstaller. Following are typical names for the files. Check the Lantronix Web site for the latest versions and release notes. UDS10
UDS100
Using DeviceInstaller
1. Download the updated firmware files from http://www.lantronix.com/ or ftp://ftp.lantronix.com/ and store them in a subfolder on your computer. 2. Click the Start button on the Task Bar and select Programs Lantronix DeviceInstaller DeviceInstaller. The DeviceInstaller window displays. 3. Click the Search the network for devices icon. The Search Network window displays. 4. Once located by DeviceInstaller, highlight the device in the device list and click the Upgrade button (which displays after you select the device). Select a custom installation by specifying the individual files and clicking Next. 5. Click the Browse button to select the location of the firmware file being loaded, then click Next.
39
Updating Firmware
6. Select Do not copy or replace any files and click Next. Note: This option upgrades the firmware file (.ROM file) only, not the Web Manager files (.COB). 7. Click Next again. The status of the upgrade shows in the window. 8. After the upgrade completes, click Close.
Using TFTP
If you are running Windows NT or higher, you can simply enter the following command at the command prompt: TFTP i IP address of UDS PUT source file name destination file name Note: It is easiest to issue the command from the same directory as the one where the firmware files are. To download new firmware using a TFTP client: 1. Use a TFTP client to send a binary file (LTX*.ROM for UDS10, DLX*.ROM for UDS100) to the unit to upgrade the unit's internal operational code, and CBXW*.cob to upgrade its internal web interface). Note: TFTP requires the .ROM (binary) version of the unit's internal operational code. 2. Make sure the Put and Binary options at the top of the window are selected. 3. Enter the full path of the firmware file in the Source File field. 4. In the Destination File field, type of the following:
3L for the UDS10 or 3D for the UDS100 to load the internal operational code WEB6 for the internal web interface.
5. In the Remote Host field, enter the IP address of the unit being upgraded. 6. Click the Put button to transfer the file to the unit.
40
Updating Firmware
The unit performs a power reset after the firmware has been loaded and stored.
SF x.x.x.x
The receiving unit performs a power reset after the firmware has been loaded and stored. Note: You can only update the units internal web interface using TFTP or DeviceInstaller.
41
Updating Firmware
2. Download the firmware to the unit using the DL command. 3. Select Send Text File and select the LTX*.HEX file for the UDS10 or DLX*.HEX file for the UDS100 to be downloaded. The downloaded file must be the .HEX (ASCII) version. 4. After receiving the final record, the unit checks the integrity of the firmware image before programming the new firmware in the flash ROM. The following message displays when the firmware upgrade is complete.
Figure 6-3. Firmware Upgrade Screen Display
42
To enter Monitor Mode with network connections, type xx1 or zzz (not three x keys as you did before). To enter Monitor Mode without network connections, type xx2 or yyy.
A 0> prompt indicates that you have successfully entered Monitor Mode.
2. Type M (upper case). A 0> prompt indicates that you have successfully entered Monitor Mode.
43
Command
SF x.x.x.x VS x.x.x.x GC x.x.x.x SC x.x.x.x PI x.x.x.x AT TT NC RS QU G0, G1...GE, GF S0, S1... SE, SF
Command Name
Send Firmware Version Get Configuration Send Configuration Ping ARP Table TCP Connection Table Network Connection Reset Quit Get configuration from memory page Set configuration to memory page
Function
Sends firmware to unit with IP address x.x.x.x. Queries software header record (16-byte) of unit with IP address x.x.x.x. Gets configuration of unit with IP address x.x.x.x as hex records. Sets configuration of unit with IP address x.x.x.x from hex records. Pings unit with IP address x.x.x.x to check device status. Shows the units ARP table entries. Shows all incoming and outgoing TCP connections. Shows the units IP configuration. Resets the units power. Exits diagnostics mode. Gets a memory page of configuration information from the device. Sets a memory page of configuration information on the device.
Entering any of the commands listed above generates one of the following command response codes:
Table 7-2. Command Response Codes
Response Meaning
0> 1> 2> 8> 9> OK; no error No answer from remote device Cannot reach remote device or no answer Wrong parameter(s) Invalid command
44
LEDs
The UDS products contain the following LEDs, which help you diagnose problems.
10 Mbps Link/Activity (green) 100 Mbps Link/Activity (green) Collisions Diagnostics (red) Status (yellow)
Simultaneously lit red and green LEDs mean something is wrong. If the red LED is lit or blinking, count the number of times the green LED blinks between its pauses. The following table explains the LED functions:
45
Serial LEDs
10 Mbps link/activity steady green 10 Mbps link/activity blinking 100 Mbps link/activity steady green 100Mbps link/activity blinking Collision blinking red
Meaning
Valid 10 Mbps network connection Network packets transmitting and receiving Valid 100 Mbps network connection Network packets transmitting and receiving
Network collisions 2 blinks = RAM error Diagnostic steady red and status blinking 4 blinks = EEPROM checksum error green 5 blinks = Duplicate IP address on network Diagnostic blinking red and status 5 blinks = No DHCP response blinking green Status steady green Status blinking green Serial port not connected to network Serial port connected to network
When troubleshooting the following problems, make sure that the UDS is powered up and the Link LED is lit solid green. If the Link LED is not lit, then the physical network connection is bad. Confirm that you are using a good network connection. We recommend that you use a serial connection so you can view any diagnostic information sent out the serial port.
Table 8-2. Problems and Error Messages
Problem/Message
When you issue the ARP S command in Windows, The ARP entry addition failed: 5 message displays. When you attempted to assign an IP address to the UDS using the ARP method, the Press Enter to go into Setup Mode error (described below) displayed. Now when you Telnet to the UDS, the connection fails.
Reason
Your currently logged-in user does not have the correct rights to use this command on this PC.
Solution
Have someone from your IT department log you in with sufficient rights.
When you Telnet into port 1 on the UDS, you are only assigning a temporary IP address. When you Telnet into port 9999 and do not press Enter quickly, the UDS reboots, causing it to lose the IP address. You did not press Enter quickly enough. You only have 5 seconds to press Enter before the connection closes.
Telnet back into port 1. Wait for it to fail, then Telnet to port 9999 again. Make sure you press Enter quickly.
When you Telnet to port 9999, the message Press Enter to go into Setup Mode displays. However, nothing happens when you press Enter, or your connection closes.
Telnet to port 9999 again, but press Enter as soon as you see the message Press Enter to go into Setup Mode.
46
Problem/Message
When you Telnet to port 1 to assign an IP address to the UDS, the Telnet window does not respond for a long time.
Reason
You may have entered the hardware address incorrectly with the ARP command.
Solution
Confirm that the hardware address that you entered with the ARP command is correct. The hardware address may only include numbers 0-9 and letters A-F. In Windows and usually in Unix, the segments of the address are separated by dashes. In some forms of Unix, the address is segmented with colons. Confirm that your PC has an IP address and that it is in the same logical subnet that you are trying to assign to the UDS. Make sure that the Link LED is lit. If the Link LED is not lit, then the UDS is not properly plugged into the network. Double-check the settings that you specified. Note: You cannot assign an IP address to a UDS through a router.
The IP address you are trying to assign is not on your logical subnet.
When you try to assign an IP with DeviceInstaller, you get the following message: No device was found at this hardware address.
The cause is most likely one of the following: The hardware address you specified is incorrect. The device is not physically connected to the network.
The unit or its power supply is damaged, or the unit is not plugged into power properly.
Try plugging the UDS into another outlet. If this does not fix the problem, contact your dealer or Lantronix Technical Support for a replacement. Consult the LEDs section above or the Quick Start for the LED flashing sequence patterns. Call Lantronix Technical Support if the blinking pattern indicates a critical error.
The UDS will not power up properly, and the LEDs are flashing.
Various
47
Problem/Message
The UDS is not communicating with the serial device attached to the UDS.
Reason
The most likely reason is the wrong serial cable or serial settings were chosen.
Solution
Make sure that you are using the correct serial cable. The UDS serial port is just like a modem serial port (DCE). The serial settings for the serial device and the UDS must match. The default serial settings for the UDS are RS232, 9600 baud, 8 character bits, no parity, 1 stop bit, no flow control.
When you try to enter Setup Mode on the UDS using the serial cable, you get no response.
The issue is likely something covered in the previous problem, or possibly you have Caps Lock on.
Double-check everything in the problem above. Confirm that Caps Lock is not on.
You can ping the UDS, but not Telnet to the UDS on port 9999.
There may be an IP address conflict on your network. You are not Telneting to port 9999. The Telnet configuration port (9999) is disabled within the UDS security settings. The unit may have the correct IP address, but an incorrect gateway address.
Turn the UDS off and then issue the following commands at the DOS prompt of your computer: ARP -D X.X.X.X (X.X.X.X is the IP of the UDS) PING X.X.X.X (X.X.X.X is the IP of the UDS). If you get a response, then there is a duplicate IP address on the network (the LEDs on the UDS should flash a sequence that tells you this). If you do not get a response, use the serial port to verify that Telnet is not disabled.
With DeviceInstaller, you get the Wrong Password error when you try to upgrade the firmware.
The file you are attempting to load is the incorrect firmware file for the UDS.
48
Problem/Message
You are using the correct serial cable, and the UDS is set up correctly, but you are not communicating with your device attached to the UDS across the network.
Reason
If you are sure that the serial cable is correct, then you may not be connecting to the correct socket of the UDS. Another possibility is that the UDS is not set up correctly to make a good socket connection to the network.
Solution
You can check to see whether there is a socket connection to or from the UDS by looking at the Status LED. If the Status LED is blinking consistently, then there is a good socket connection. If the Status LED is solid green, then the socket connection does not exist. Use the Connect Mode option C0 for making a connection to the UDS from the network. Use Connect Mode option C1 or C5 for a connection to the network from the UDS. See the full list of Connect Mode hexadecimals in B: Binary to Hexadecimal.
When connecting to Web Manager within the UDS, the message No Connection With The UDS displays.
Your computer is not able to connect to port 30718 (77FEh) on the UDS.
Make sure that port 30718 (77FEh) is not blocked with any router that you are using on the network. Also make sure that port 77FEh is not disabled within the Security settings of the UDS.
Technical Support
If you are experiencing an error that is not described in this chapter, or if you are unable to fix the error, you may:
Check our online knowledge base at http://www.lantronix.com/support Call us at: (800) 422-7044 Domestic (949) 453-7198 International (949) 450-7226 Fax
Our phone lines are open from 6:00AM - 5:30 PM Pacific Time Monday through Friday excluding holidays. Technical Support Europe, Middle East, Africa Phone: +49 (0) 89 31787 817 Email: eu_techsupp@lantronix.com or eu_support@lantronix.com Firmware downloads, FAQs, and the most up-to-date documentation are available at: http://www.lantronix.com/support
49
Your name, and your company name, address, and phone number Lantronix UDS model number Lantronix UDS serial number Software version (on the first screen shown when you Telnet to port 9999) Description of the problem Debug report (stack dump), if applicable Status of the unit when the problem occurred (please try to include information on user and network activity at the time of the problem)
50
51
52
Null-Modem Cable
When attaching the DB9 of the UDS to the DB9 com port on a PC, use a null-modem cable (Lantronix Part No. 500-163). The figure below shows the pinouts for a DB9 to DB9 null-modem cable. To configure the UDS using the DB9 serial port, you only need to pinout the TXD, RXD, and GND signals.
Figure 9-4. Null-Modem Cable (Lantronix Part No. 500-163)
Network Port
The unit's back panel contains a power plug and an RJ45 (10/100) Ethernet port. Power input range on the power plug is 9-30 VDC or 9-24 VAC.
Figure 9-5. Network Interface
53
54
Network Interface 10 Mbps RJ45 Ethernet Power Supply External adapter included 120 VAC USA 100 - 240 VAC Universal with regional connectors 9-30 VDC or 9-24 VAC (1W maximum) Height: 2.3 cm (0.9 in) Width: 6.4 cm (2.5 in) Depth: 9.0 cm (3.5 in) 0.35 Kg (0.8 lbs) Operating range: 5 to 50 C (41 to 122 F) Storage range: -40 to 66 C (-40 to 151 F)
Weight Temperature
Relative Humidity Operating: 10% to 90% non-condensing, 40% to 60% recommended Storage: 10% to 90% non-condensing
55
Technical Specifications
Serial Interface
Network Interface 10/100 RJ45 Ethernet Power Supply External adapter included 120 VAC USA 100 - 240 VAC Universal with regional connectors 9-30 VDC or 9-24 VAC (1W maximum) Height: 2.3 cm (0.9 in) Width: 6.4 cm (2.5 in) Depth: 9.0 cm (3.5 in) 0.35 Kg (0.8 lbs) Operating range: 5 to 50 C (41 to 122 F) Storage range: -40 to 66 C (-40 to 151 F)
Weight Temperature
Relative Humidity Operating: 10% to 90% non-condensing, 40% to 60% recommended Storage: 10% to 90% non-condensing
56
DHCP
The unit ships with a default IP address of 0.0.0.0, which automatically enables DHCP. If a DHCP server exists on the network, it provides the unit with an IP address, gateway address, and subnet mask when the unit boots up. You can use the DeviceInstaller software to search the network for the DHCPassigned IP address and add it to the list of devices retrieved. Note: This DHCP address does not appear in the units Setup Mode or in Web Manager. You can determine your units DHCP-assigned IP address in Monitor Mode. When you enter Monitor Mode from the serial port with network connection enabled (see Entering Monitor Mode Using the Serial Port on page 43) and issue the NC (Network Communication) command, you see the units IP configuration.
AutoIP
The unit ships with a default IP address of 0.0.0.0, which automatically enables Auto IP within the unit. AutoIP is an alternative to DHCP that allows hosts to automatically obtain an IP address in smaller networks that may not have a DHCP server. A range of IP addresses (from 169.254.0.1 to 169.254.255.1) has been explicitly reserved for AutoIP-enabled devices. Do not use this range of Auto IP addresses over the Internet.
If your unit cannot find a DHCP server, and you have not manually assigned an IP address to it, the unit automatically selects an address from the AutoIP reserved range. Then, your unit sends out a (ARP) request to other nodes on the same network to see whether the selected address is being used. If the selected address is not in use, then the unit uses it for local subnet communication. If another device is using the selected IP address, the unit selects another address from the AutoIP range and reboots. After reboot, the unit sends out another ARP request to see if the selected address is in use, and so on.
AutoIP does not replace DHCP. The unit continues to look for a DHCP server on the network. If it finds a DHCP server, the unit switches to the DHCP server-provided address and reboots. Note: If a DHCP server is found, but it denies the request for an IP address, the unit does not attach to the network, but waits and retries. AutoIP can be disabled by setting the units IP address to 0.0.1.0. This setting enables DHCP but disables AutoIP.
57
BOOTP
Similar to DHCP, but for smaller networks. Automatically assigns the IP address for a specific duration of time.
Note: For the ARP command to work on Windows 95, the ARP table on the PC must have at least one IP address defined other than its own. 2. If you are using Windows 95, type ARP -A at the DOS command prompt to verify that there is at least one entry in the ARP table. If the local machine is the only entry, ping another IP address on your network to build a new entry in the ARP table; the IP address must be a host other than the machine on which you are working. Once there is at least one additional entry in the ARP table, use the following command to ARP an IP address to the unit:
arp -s 191.12.3.77 00-20-4a-xx-xx-xx
3. Open a Telnet connection to port 1. The connection fails quickly, but the unit temporarily changes its IP address to the one designated in this step.
telnet 191.12.3.77 1
4. Open a Telnet connection to port 9999, and press Enter within five seconds to go into Setup Mode. If you wait longer than five seconds, the unit reboots.
telnet 191.12.3.77 9999
Note: The IP address you just set is temporary and reverts to the default value when the units power is reset, unless you configure the unit with a static IP address and store the changes permanently.
58
Connect Mode Options Disconnect Mode Options Flush Mode (Buffer Flushing) Options Interface Mode Options Pack Control Options
Conversion Table
Hexadecimal digits have values ranging from 0 to F, which are represented as 0-9, A (for 10), B (for 11), etc. To convert a binary value (for example, 0100 1100) to a hexadecimal representation, the upper and lower four bits are treated separately, resulting in a two-digit hexadecimal number (in this case, 4C). Use the following table to convert values from binary to hexadecimal. Decimal
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Binary
0000 0001 0010 0011 0100 0101 0110 0111 1000 1001 1010 1011 1100 1101 1110 1111
Hex
0 1 2 3 4 5 6 7 8 9 A B C D E F
59
Scientific Calculator
Another simple way to convert binary to hexadecimals is to use a scientific calculator, such as the one available on Windows operating systems. For example: 1. On the Windows Start menu, click ProgramsAccessoriesCalculator. 2. On the View menu, select Scientific. The scientific calculator displays. 3. Click Bin (Binary), and type the number you want to convert.
60
Hostlist
Hex
N/A 1 2 3 4 5 C 10 11 12 13 14 15 1C 40 41 42 43 44 45 4C 50 51 52 53 54 55 N/A C0 C1 C2 C3 C4
61
Hostlist
Hex
C5 CC D0 D1 D2 D3 D4 D5 DC N/A 21 22 23 N/A 25 N/A N/A 31 32 33 N/A 35 N/A N/A 61 62 63 N/A 65 N/A N/A 71 72 73 N/A 75 N/A Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist
No active startup Hostlist Any character Active DTR CR (0x0D) Manual connection Autostart UDP Any character Active DTR CR (0x0D) Manual connection Autostart UDP Any character Active DTR CR (0x0D) Manual connection Autostart UDP Any character Active DTR CR (0x0D) Manual connection Autostart UDP
62
Hostlist
Hex
No active startup Hostlist Any character Active DTR CR (0x0D) Manual connection Autostart UDP Any character Active DTR CR (0x0D) Manual connection Autostart UDP Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist Hostlist
The following connect mode options are for when you use modem emulation: Connect Mode Options for Modem Emulation Accept Response Hex Incoming Connections
Never Never Never With DTR With DTR With DTR Unconditionally Unconditionally Unconditionally Echo Without echo 1-character response Echo Without echo 1-character response Echo Without echo 1-character response 16 6 7 56 46 47 D6 C6 C7
63
Hard Disconnect
Hex
Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Disable Disable Disable Disable Disable Disable Disable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable
0 10 20 30 40 50 60 70 80 90 A0 B0 C0 D0 E0 F0 1 11 21 31 41 51 61 71 81 91 A1 B1 C1 D1 E1 F1 8 18 28 38 48 58 68
64
Disconnect Mode Options Disconnect Telnet Mode Channel with DTR and (port) Drop Terminal Password Type Setup
Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable
Hard Disconnect
Hex
Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable
78 88 98
Enable Enable
A8 B8 C8 D8
Enable Enable
E8 F8 9 19
Enable Enable
29 39 49 59
69 79 89 99 A9 B9 C9 D9
Enable Enable
E9 F9
65
Hex
0 10 20 30 40 50 60 70
80 90 A0 B0 C0 D0 E0 F0
1 11 21 31 41 51 61 71
81 91 A1
66
Flush Mode Options Serial to Network Network to Serial Clear input buffer upon:
Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Hex
B1 C1 D1 E1 F1
Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection
2 12 22 32 42 52 62 72
Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection Passive connection
82 92 A2 B2 C2 D2 E2 F2
Active connection Passive connection Active connection Passive connection Active connection Passive connection Disconnect Active connection Passive connection Active connection Passive connection Active connection Passive connection Active connection Passive connection
3 13 23 33 43
67
Flush Mode Options Serial to Network Network to Serial Clear input buffer upon:
Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Hex
53 63 73
83 93 A3 B3 C3 D3 E3 F3
Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect
Active connection Passive connection Passive connection Active connection Active connection Passive connection Active connection Passive connection Active connection Passive connection Active connection Passive connection Active connection Passive connection Disconnect Disconnect Disconnect Disconnect Disconnect Disconnect Disconnect Disconnect
4 14 24 34 44 54 64 74
84 94 A4 B4 C4 D4
68
Flush Mode Options Serial to Network Network to Serial Clear input buffer upon:
Passive connection Disconnect Active connection Passive connection Disconnect
Hex
E4 F4
Active connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Active connection Passive connection Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Enable Enable Enable Enable Enable Enable Enable Enable
5 15 25 35 45 55 65 75
85 95 A5 B5 C5 D5 E5 F5
6 16 26 36
69
Flush Mode Options Serial to Network Network to Serial Clear input buffer upon:
Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Hex
46 56 66 76
86 96 A6 B6 C6 D6 E6 F6
Active connection Passive connection Active connection Passive connection Disconnect Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Active connection
Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect
17
Passive connection
27
37
47
57
67
70
Flush Mode Options Serial to Network Network to Serial Clear input buffer upon:
Active connection Passive connection Disconnect
Hex
77
Enable
87
Active connection
Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect Active connection Passive connection Disconnect
Enable
97
Passive connection
Enable
A7
Enable
B7
Enable
C7
Active connection Disconnect Passive connection Disconnect Active connection Passive connection Disconnect
Enable
D7
Enable
E7
Enable
F7
71
Bits
7 7 7 7 7 7 8 8 8 8 8 8 7 7 7 7 7 7 8 8 8 8 8 8 7 7 7 7 7 7 8 8 8 8 8 8
72
Hex
1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 1-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence
No No No No 1 1 1 1 2 2 2 2 No No No No 1 1 1 1 2 2 2 2 No No No No 1 1 1 1 2 2 2 2 No No No
0 1 2 3 4 5 6 7 8 9 A B 10 11 12 13 14 15 16 17 18 19 1A 1B 20 21 22 23 24 25 26 27 28 29 2A 2B 30 31 32
73
Hex
2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence 2-Byte Sequence
No 1 1 1 1 2 2 2 2
33 34 35 36 37 38 39 3A 3B
74
Declaration of Conformity
(according to ISO/IEC Guide 22 and EN 45014) Manufacturers Name & Address: Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA Declares that the following product: Product Name Model: Device Servers UDS10 and UDS100
Conforms to the following standards or other normative documents: Safety: EN60950:1992+A1, A2, A3, A4, A11 Electromagnetic Emissions: EN55022: 1994 (IEC/CSPIR22: 1993) FCC Part 15, Subpart B, Class B IEC 1000-3-2/A14: 2000 IEC 1000-3-3: 1994 Electromagnetic Immunity: EN55024: 1998 Information Technology Equipment-Immunity Characteristics IEC61000-4-2: 1995 Electro-Static Discharge Test IEC61000-4-3: 1996 Radiated Immunity Field Test IEC61000-4-4: 1995 Electrical Fast Transient Test IEC61000-4-5: 1995 Power Supply Surge Test IEC61000-4-6: 1996 Conducted Immunity Test IEC61000-4-8: 1993 Magnetic Field Test IEC61000-4-11: 1994 Voltage Dips & Interrupts Test (L.V.D. Directive 73/23/EEC) Supplementary Information: This Class A digital apparatus complies with Canadian ICES-003 (CSA) and has been verified as being compliant within the Class A limits of the FCC Radio Frequency Device Rules (FCC Title 47, Part 15, Subpart B CLASS A), measured to CISPR 22: 1993 limits and methods of measurement of Radio Disturbance Characteristics of Information Technology Equipment. The product complies with the requirements of the Low Voltage Directive 72/23/EEC and the EMC Directive 89/336/EEC. Export Control Classification Number 5A002, License exception ENC. Manufacturers Contact: Director of Quality Assurance, Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA Tel: 949-453-3990 Fax: 949-453-3995
75
Warranty
Lantronix warrants each Lantronix product to be free from defects in material and workmanship for a period of TWO YEARS after the date of shipment. During this period, if a customer is unable to resolve a product problem and Lantronix Technical Support determines the product is defective, a Return Material Authorization (RMA) will be issued. Following receipt of an RMA number, the customer shall return the product to Lantronix, freight prepaid. Upon verification of warranty, Lantronix will -- at its option -- repair or replace the product and return it to the customer freight prepaid. If the product is not under warranty, the customer may have Lantronix repair the unit on a fee basis or return it. No services are handled at the customer's site under this warranty. This warranty is voided if the customer uses the product in an unauthorized or improper way, or in an environment for which it was not designed. Lantronix warrants the media containing its software product to be free from defects and warrants that the software will operate substantially according to Lantronix specifications for a period of 60 DAYS after the date of shipment. The customer will ship defective media to Lantronix. Lantronix will ship the replacement media to the customer. * * * *
In no event will Lantronix be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss of equipment, plant or power system, cost of capital, loss of profits or revenues, cost of replacement power, additional expenses in the use of existing software, hardware, equipment or facilities, or claims against the user by its employees or customers resulting from the use of the information, recommendations, descriptions and safety notations supplied by Lantronix. Lantronix liability is limited (at its election) to: Refund of buyer's purchase price for such affected products (without interest) Repair or replacement of such products, provided that the buyer follows the above procedures. There are no understandings, agreements, representations or warranties, express or implied, including warranties of merchantability or fitness for a particular purpose, other than those specifically set out above or by any existing contract between the parties. Any such contract states the entire obligation of Lantronix. The contents of this document shall not become part of or modify any prior or existing agreement, commitment, or relationship. For details on the Lantronix warranty replacement policy, please go to our Web site at http://www.lantronix.com/support/warranty/index.html.
76
Index
Application examples, 10 ARP and Telnet, 58 ARPCache timeout, 36 AutoIP, 15, 57 Baudrate, 26 Binary to hexadecimal conversions, 59 BOOTP, 15, 58 Buffer flushing, 33 Cable, 53 Com Port Redirector tutorial, 19 Compliance, 75 Connect Mode, 28 Connectors, 51 DB9 to DB9 null-modem cable, 53 Defaults List, 38 Resetting, 38 DeviceInstaller Assigning IP address, 16 Disabling configuration by, 37 Installing from product CD, 16 DHCP, 15, 57 DHCP name, 25 Diagnostics, 43 Disabling TFTP for Upgrades, 37 Disconnect Mode, 33 Downloading firmware, 19 Echo port, 37 Error messages, 46 Ethernet address, 13 Firmware files, 39 Firmware upgrade, 39 Flow control, 27 Flush Mode, 33 Gateway, 16, 20, 24 Hardware address, 13, 15 Inactivity timeout, 35 Installation, 14 Interface (I/F) Mode, 26 Internal web server, 12 IP address Alternative methods of assigning, 57 Assigning by DeviceInstaller, 16 Assigning by Web Manager, 20 Assigning in Setup Mode, 24 Factory default, 15 Remote, 32 Requirement, 15 Searching for on the network, 17 Label, 13 LEDs, 45 MAC address, 13 Modem emulation, 12 Modem Mode, 30 Monitor Mode Accessing, 43 Commands, 44 Network class, 16 Null-modem cable, 53 Pack control, 34 Password Channel (Port), 35 Enhanced security, 37 Pinouts, 19, 51 Port 9999 for Setup Mode access, 27 Disabling Echo, 37 Number, 27 Password, 35 Remote, 32 Power plug, 53 Protocols, 12 Redirection software, 10 Remote IP address, 32 Required information, 15 Reserved port numbers, 27 RJ45 Ethernet port, 53 RS-232 and RS-485/422 standards, 51 Security settings, 21, 36 Send characters, 35 Serial port Accessing Setup Mode, 17
77
Index Login, 17 Settings, 26 Serial tunneling Example, 10 Tutorial, 19 Server properties, 20 Setup Mode Accessing by Serial Port, 23 Accessing using Telnet, 22 Disabling Telnet access, 37 using, 23 SNMP Changing community name, 37 Disabling, 36 Subnet mask Assigning on Web Manager, 20 TCP Keepalive time, 36
UDS10/UDS100 User Guide Technical specifications UDS10, 55 UDS100, 56 Technical Support, 49 Telnet Configuration password, 25 Password, 20 Terminal type, 35 TFTP, 40 Troubleshooting, 45 UDS settings configuration window, 19 Updating firmware, 39 Warranty, 76 Web browser, 18 Web Manager Configuration using, 19 Disabling configuration by, 37