You are on page 1of 1

C 0F32 ERROR CODE

Solution:
1. ATDC setting error - COF32, run F8 & use actual value, do not reduce setting value. open sie cover to reset. 2. Cof32 is telling us that ATDC sensor is reading toner supply incorrectly, now this Toner Density Control sensor sits inside the developer unit of this machine, and toner is feed into it, where the atdc sensor reads the amount of toner that it has mixed with the developer and adjust it occording to level initally set when developer was first installed. Developer can become old and not attract the toner any more Toner can clog up and not be able to get to it Developer can be spilt so it is no longer at right level. Maybe it wont stir cause of something mechanical Sensor rarely fails or maybe the ATDC sensor needs to reset it's level (service f8) not sure but ...Service mode stop 00 stop 01 then select F and 8 link to new dev http://supplydepot.com/amazing/itemdesc.asp?ic=MIN8936416&eq=&Tp
3.

COF32 is an ATDC sensor failure. (toner density)

The ATDC value might be wrong if you just renewed the toner. Adjust the ATDC value in the service menu. 4.
5. Auto Toner Density Level. Replace the developer. It should sort it.

Removed Drum Unit, emptied excess toner, cleaned and installed. After short start- up code cof32 appeared.

You might also like