PERRY JOHNSON LABORATORY ACCREDITATION, INC.

Certificate of Accreditation
Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of:

Centro de Desarrollo en Instrumentacin y Capacitacin, S.C. (CEDICA)


Calle Nios Hroes #264, Lomas del Camichn, Tonal, Jalisco, C.P. 45417

(Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard:

ISO/IEC 17025:2005
This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communiqu dated January 2009):

Calibration of Dimensional, Mechanical, Thermodynamic and Mass, Force and Weighing Instruments
(As detailed in the supplement)

Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation bodys duty to observe and comply with the said rules.

For PJLA:
Initial Accreditation Date:
November 26, 2012

Issue Date:

Accreditation No.:
70741

Certificate No.:
L12-218

November 26, 2012

Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084
The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website: www.pjlabs.com Page 1 of 4

Certificate of Accreditation: Supplement


Centro de Desarrollo en Instrumentacin y Capacitacin, S.C. (CEDICA)
Calle Nios Hroes #264, Lomas del Camichn, Tonal, Jalisco, C.P. 45417 Contact Name: Jorge Jimenez Phone: (52) (333) 614-7753

Accreditation is granted to the facility to perform the following calibrations:

Dimensional
MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY () CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED

Caliper

Up to 600 mm

(12.1 + 3.5x10-3L) m (7.18 x 10-1 + 8.94 x 10-3L) m (7.48 x 10-1 + 9.74 x 10-3L) m (7.9 + 1.04 x 10-3L) m (13.6 + 5 x 10-3L) m 0.64 mm 0.81 mm 0.72 mm 0.92 mm

Outside Micrometer

Up to 300 mm

NMX-CH-002-2004 Set Block Gage. Grade 0 and Step Master NMX-CH-099-2005 Set Block Gage Grade 0 NMX-CH-093-2005 Set block Gage Grade 0 NMX-CH-036-1994 Set Block. Gage Grade 0 NMX-CH-141-2005 Master Block 0 or 1 NMX-148-SCFI-2004 Master Rule

Inside Micrometer

12.5 mm to 300 mm

Indicator Height Gage Ruler Error of Indication

Up to 50 mm Up to 600 mm Up to 1 000 mm (Res.= 0.5 mm) Up to 1 000 mm (Res.= 1 mm) Up to 8 000 mm (Res.= 0.1 mm) Up to 8 000 mm (Res.= 1 mm)

Tape Error of Indication

NOM-046-SCFI-1999 Master Rule

Thermodynamic
MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY () CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED

Thermocouple Type J (R= 0.1 C) Thermocouple Type K (R= 1C) Thermometers (R= 2C) Bi metallic Thermometer (R= 5C)

-20 C to 420 C -20 C to 420 C -20 C to 420 C -20 C to 420 C

0.057 C 0.57 C 1.15 C 2.89 C

NMX-CH-070-1993 Thermometer readout 1502A & RTD PT-100 mod 5615 FLUKE

Issue: 11/12

This supplement is in conjunction with certificate # L12-218

Page 2 of 4

Certificate of Accreditation: Supplement


Centro de Desarrollo en Instrumentacin y Capacitacin, S.C. (CEDICA)
Calle Nios Hroes #264, Lomas del Camichn, Tonal, Jalisco, C.P. 45417 Contact Name: Jorge Jimenez Phone: (52) (333) 614-7753

Accreditation is granted to the facility to perform the following calibrations:

Mechanical
MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY () CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED

Pressure Gages

50 psi to 500 psi

0.25 % reading

Indirect Verification of Rockwell Hardness Testers HRB

HRB 40 HRB to 59 HRB 60 HRB to 79 HRB 80 HRB to 100 HRB HRC 20 HRC to 30 HRC 31 HRC to 59 HRC 60 HRC to 65 HRC 0.22 HRC 0.20 HRC 0.22 HRC 0.47 HRB 0.35 HRB 0.51 HRB

Digital Pressure Gage Dwyer DPGW-11 NOM-013-SCFI-2004 ASTM E18 Hardness test Block

Indirect Verification of Rockwell Hardness Testers HRC

Mass, Force and Weighing Devices


MEASURED INSTRUMENT, QUANTITY OR GAUGE RANGE OR NOMINAL DEVICE SIZE AS APPROPRIATE CALIBRATION AND MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINTY () CALIBRATION EQUIPMENT AND REFERENCE STANDARDS USED

Torque

0.113 N.m to 1.13 N.m

0.65 % of reading

Scales

0.010 kg to 50 kg (Res.= 0.010 kg) 0.020 kg to 100 kg (Res.= 0.020 kg) 0.050 kg to 200 kg (Res.= 0.050 kg) 0.1 kg to 500 kg (Res.= 0.100 kg)

11.9 g 23.8 g 58.8 g 119 g

ANSI B107.300-2010; NMX-CH6789-IMNC-2006 Torque Analyzer Mountz TL-10i NOM-010-SCFI-1994; NMX-CH009-SCFI-1994 Master Weights Class M1

1.

The CMC (Calibration and Measurement Capability) stated for calibrations included on this scope of accreditation represent the smallest measurement uncertainties attainable by the laboratory when performing a more or less routine calibration of a nearly ideal device under nearly ideal conditions. It is expressed at a confidence level of 95 % using a coverage factor k (usually equal to 2). The actual measurement uncertainty associated with a specific calibration performed by the laboratory will typically be larger than the CMC for the same calibration since capability and performance of the device being calibrated and the conditions related to the calibration may reasonably be expected to deviate from ideal to some degree.

Issue: 11/12

This supplement is in conjunction with certificate # L12-218

Page 3 of 4

Certificate of Accreditation: Supplement


Centro de Desarrollo en Instrumentacin y Capacitacin, S.C. (CEDICA)
Calle Nios Hroes #264, Lomas del Camichn, Tonal, Jalisco, C.P. 45417 Contact Name: Jorge Jimenez Phone: (52) (333) 614-7753

Accreditation is granted to the facility to perform the following calibrations:

2.

3. 4. 5.

The laboratories range of calibration capability for all disciplines for which they are accredited is the interval from the smallest calibrated standard to the largest calibrated standard used in performing the calibration. The low end of this range must be an attainable value for which the laboratory has or has access to the standard referenced. Verification of an indicated value of zero in the absence of a standard is common practice in the procedure for many calibrations but by its definition it does not constitute calibration of zero capacity. The term L represents length in inches or millimeters appropriate to the uncertainty statement. The term Wt represents weight in pounds or grams (including SI multiple and submultiple units) appropriate to the uncertainty statement. The term P represents pressure in psi.

Issue: 11/12

This supplement is in conjunction with certificate # L12-218

Page 4 of 4

Perry Johnson Laboratory Accreditation, Inc.

November 26, 2012

Mr. Jorge Jimenez Centro de Desarrollo en Instrumentacin y Capacitacin, S.C. (CEDICA) Calle Nios Hroes #264 Lomas del Camichn, Tonal, Jalisco, C.P. 45417 Dear Mr. Jimenez: This letter is to confirm that you have successfully completed your accreditation assessment. A certificate has now been granted and posted on our website. As you are aware, PJLA will no longer be issuing expiration dates on our certificates. Your certificate # L12-218 will remain valid as long as you continue to maintain your annual assessments and reaccreditation assessments as stated in your customer agreement with PJLA. At this time, we have confirmed that your annual assessments will be conducted during the month of October each calendar year. This will include an interim surveillance assessment and a full system reassessment to be completed by November 2014. Once your reassessment is conducted and approved by our accreditation committee a revised status letter will be provided to you. Please allow PJLA at least 120 days from your assessment due date to issue this letter. Please feel free to release this letter to any interested parties as confirmation of your certificate validity. Also, please remind them that your certificate is posted on our website at all times. Any changes in regards to your accreditation status will be reflected on our website. We would like to thank you for your patronage and we look forward to continuously serving your accreditation needs in the future. If we can assist you any further, please feel free to contact us at any time.

Sincerely,

Tracy Szerszen President/Operations Manager

755 W. Big Beaver Rd. Suite 1325 Troy, MI 48084 Phone: 1-877-369-LABS or 248-519-2603 Fax: 248-213-0737