You are on page 1of 7

PRUEBA INYECTOR 1 (

32F61-00012////2SL01441356C////5735////3406////1791
1 SIN CONECCION DEL RETORNO
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.00 mL
Actual return OilMass: 0.00 mL
Actual test result: out of limits
----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 24.70 mL
Actual return OilMass: 0.10 mL
Actual test result: out of limits
----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 10.90 mL
Actual return OilMass: 0.10 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 15.40 mL
Actual return OilMass: 0.10 mL
Actual test result: out of limits

B CON CONECCION DE RETORNO


----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.20 mL
Actual return OilMass: 1.40 mL
Actual test result: out of limits
----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 20.70 mL
Actual return OilMass: 20.10 mL
Actual test result: out of limits
----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 9.90 mL
Actual return OilMass: 19.30 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 15.80 mL
Actual return OilMass: 35.20 mL
Actual test result: out of limits

PRUEBA INYECTOR 2 (
32F61-00012////2SL01441337E////9340////7545////0087
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.40 Ml
Actual return OilMass: 1.20 mL

presion(85 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 19.80 mL
Actual return OilMass: 12.20 mL

Presion (73 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 10.90 mL
Actual return OilMass: 13.10 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 15.20 mL
Actual return OilMass: 22.00 mL
Actual test result: out of limits

Presion (38 Mpa)

Presion

(75 Mpa)

PRUEBA INYECTOR 3 (
32F61-00012////2SL014414315////4370////5580////3376
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.20 Ml
Actual return OilMass: 1.90 mL

Presion (74 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 18.00 mL
Actual return OilMass: 11.30 mL

Presion (70 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 12.50 mL
Actual return OilMass: 12.00 mL

Presion (38 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 12.80 mL
Actual return OilMass: 21.80 mL
Actual test result: out of limits

Presion (70 Mpa)

PRUEBA INYECTOR 4 (
32F61-00012////2SL01441346B////5939////5762////3626
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: -0.10 mL
Actual return OilMass: 1.30 mL

Presion (70 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 19.50 mL
Actual return OilMass: 13.10 mL

Presion (75 Mpa)

Actual test result: out of limits


----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 11.40 mL
Presion (38 Mpa)
Actual return OilMass: 14.50 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 16.40 mL
Actual return OilMass: 22.60 mL
Actual test result: out of limits

Presion (80 Mpa)

PRUEBA INYECTOR 5 (
32F61-00012////2SL014414212////1822////6459////3506
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.10 mL
Actual return OilMass: 2.40 mL
Actual test result: out of limits
----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 32.80 mL
Actual return OilMass: 20.60 mL
Actual test result: out of limits
----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 10.80 mL
Actual return OilMass: 13.10 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 14.30 mL
Actual return OilMass: 23.70 mL

Actual test result: out of limits

PRUEBA INYECTOR 6 (
32F61-00012////2SL014413665////2095////5658////3526
----------------------------------------------->>>> 1. LEAK TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 310 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 0 uS
Injector pulse Times : 60 T
Standard injecte OilMass: 0.00 mL 0.00 mL
Standard return OilMass: 40.00 mL 30.00 mL
< Test Result >
Actual injecte OilMass: 0.10 mL
Actual return OilMass: 1.80 mL
Actual test result: out of limits
----------------------------------------------->>>> 2. VL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 1000 RPM
Common Rail pressured : 135 MPa
Injector pulse wide
: 1055 uS
Injector pulse Times : 500 T
Standard injecte OilMass: 24.50 mL 2.20 mL
Standard return OilMass: 30.00 mL 20.00 mL
< Test Result >
Actual injecte OilMass: 31.60 mL
Actual return OilMass: 22.80 mL
Actual test result: out of limits
----------------------------------------------->>>> 3. LL TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 38 MPa
Injector pulse wide
: 660 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 1.00 mL 1.00 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test Result >
Actual injecte OilMass: 7.50 mL
Actual return OilMass: 16.20 mL
Actual test result: out of limits
----------------------------------------------->>>> 4. VE TEST
-----------------------------------------------< List Testing condition >
Workbench rotate speed: 600 RPM
Common Rail pressured : 80 MPa
Injector pulse wide
: 575 uS
Injector pulse Times : 1000 T
Standard injecte OilMass: 2.30 mL 0.20 mL
Standard return OilMass: 0.00 mL 0.00 mL
< Test
Actual
Actual
Actual

Result >
injecte OilMass: 12.50 mL
return OilMass: 31.10 mL
test result: out of limits