Client: Project Location: Project Desc:

Tank Desc: Job Number: Rev Number:

Designed By: Checked By: Date:

Rectangular Tank Design


H. Horizontal Stiffener Design (Long Side) 3. Bending Strength
B := CBFbyTF( BEAM2) if BEAM2 31 WBFby2TFBEAM231 otherwise HbyTW := CHbyTW( BEAM2) if BEAM2 31 WHbyTWBEAM2 31 otherwise Es FyB Es FyB 4 HbyTW 0.76 if 4 HbyTW 4 HbyTW otherwise > 0.76 < 0.35 Limiting slenderness for compact flange (Table B4.1) Flange slenderness ratio for local buckling (AISC 360-05 F3-1) Web slenderness ratio (AISC 360-05 F3-2)

pfB := 0.38

rfB := 1.0

Limiting slenderness for non-compact flange (Table B4.1)

kcB :=

0.35 if

(AISC 360-05 F3-2)

MnFLB := 0.9 MpB ...

MpB ...

rfB pfB + 0.7 F S yB xB) (


B pfB

Moment strength based on flange local buckling (AISC 360-05 F3-1)

MnFLBB :=

0.9 MpB if B pfB MnFLB if 0.9

(B > pfB) (B rfB)


2

0.9 Es kcB SxB

otherwise

Moment strength based on flange local buckling with limits (AISC 360-05 F3-1)

( )
B

www.mathcadcalcs.com