You are on page 1of 2

Shearfix Punching Shear Reinforcement Guidance for Completion of BS EN 1992 (EC2) Design Sheet

Design Software Ancon Shearfix design software is available to download free from www.ancon.co.uk. The software will check your application for punching shear requirement and provide details of any required Shearfix rails including a DXF file detailing the arrangement. The software carries out designs to both BS EN 1992 (Eurocode 2) and BS 8110. Ancon is pleased to offer a punching shear reinforcement design service. To ensure we receive all necessary design information Ancon requires the design information for each column to be compiled together. Unfortunately we are unable to offer a Shearfix design service based upon sets of separate drawings; the design sheet on the following page has been developed for the transfer of this information. Following receipt of the design information for each application you would like us to consider, calculation sheets will be returned to you detailing the required Shearfix rails. Ancon can carry out designs to either BS 8110 or BS EN 1992 (Eurocode 2). A design information sheet is available for each code; please complete the appropriate sheet. Notes for BS EN 1992 (Eurocode 2) Designs Loads Please note, that whilst there is a column on the design sheet for moments, these cannot be used in all applications. For different column types the following options are avaliable for specifying loads:

Column Type Interior Edge Corner Re-entrant Corner Direction of Moments

Load Specification Options for EC2 Specify VEd with set factor of 1.15 or Specify VEd with set factor of 1.4 Specify VEd with set factor of 1.5 n/a or or Specify Veff Specify Veff Specify Veff Specify Veff or Specify VEd and Moments n/a n/a n/a

N Mz z My

N z

Reinforcement in direction z

y z y y z

Reinforcement in direction y

Rail Arrangements Ancon provides solutions in either orthogonal or radial layouts, therefore please remember to indicate your preference on the design sheet. In the absence of this information we will provide what we consider to be the best / most economical solution for each case which will inevitably mean a mix of the two in the overall design. Reinforcement Please indicate the reinforcement diameter and spacing on the sheet. Where additional reinforcement is being used, please provide both sizes i.e. for main reinforcement of 16mm @ 200mm spacings plus additional reinforcement of 20mm @ 200mm spacings, please write 16 + 20 @ 200. Edge Distances T2 ). Edge distances are restricted to three times the effective depth where the effective depth is slab depth - top cover - ( T1 + 2

Ancon Building Products, President Way, President Park, Sheffield S4 7UR, United Kingdom. Tel: +44 (0) 114 275 5224, Fax: +44 (0) 276 8543 Email: info@ancon.co.uk Web: www.ancon.co.uk

Page 1 of____

Shearfix Punching Shear Reinforcement to BS EN 1992 (EC2) - Design Information


Please refer to the additional guidance sheet before completing this form. Project name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Project address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .................................................. Date . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Slab depth . . . . . . . . . . . . . . . mm Contact name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Email . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Concrete cover top Concrete cover bottom . . . . . . . . . mm . . . . . . . . . mm OR Your Column Reference Column Type (A1, A2...) (see below) Column Dimension (mm) yxz Edge Distance (mm) d* c* VEd (kN) Ultimate Load ULS Moments** kNm Mz My Veff (kN) Effective Load ULS Reinforcement in direction y bar spacing Reinforcement in direction z bar spacing Rail Layout (tick one) Radial Best solution per column Orthogonal Voids (mm) (Please supply drawings to clarify positions of voids) Size Position vy vz y z

Concrete strength C . . . . . . / ........

Note: Refer to supplementary sheet for information on moments and possible load combinations.

* Maximum 3 x effective depth. ** Mz moments act in the columns y direction i.e. horizontally across the columns when orientated as shown below. Please refer to the guidance sheet for more information. If left blank, standard factors will be applied.

Column Type

A1
z y

A2
z y edge d*

A3
z y d* edge c* z d*

A4
c* edge

A5

A6

A7
c* edge

A8

Void Position and Size y

z y d* edge c*

void vz vy

y edge

y edge

d*

d*

y edge

Faxback to +44 (0) 114 276 8543 or email: tech@ancon.co.uk


Ancon Building Products, President Way, President Park, Sheffield S4 7UR, United Kingdom. Tel: +44 (0) 114 275 5224, Web: www.ancon.co.uk