You are on page 1of 125

Alarm Records -- Query Alarm Logs

Save Time: 09/18/2013 09:23:00


User Name:danielwk

Occurrence start time Later than 09/17/2013 00:00:00.Occurrence end time Earlier than 09/17/2013 23:59:59.Maintenance status =

Severity
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Warning
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Major
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor

Name
Alarm ID Alarm Source
NE Type Location Information
MO Object Occurrence Time(NT)
Shelter Door
65062
Open
BBBL3/DA25_NibKoba
GBTS
Cabinet
[Swap] No.=0,
DA25_NibKoba
Subrack
09/17/2013
No.=40,
[Swap]
Slot
23:31:39
No.=0, Port No.=15, Boa
Fan Alarm 2354
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PMU,
09/17/2013
Board
20:01:37
No.=0, PassNo=255, S
Fence break2416
or grounding
BBBL3/4696_Payung
cut or AC
GBTS
remove Site No.=56,4696_Payung
Board Type=EAC,
09/17/2013
Board
20:01:35
No.=0, PassNo=255, Su
MSPF
2408
BBBL3/4696_Payung
GBTS
Site No.=56,4696_Payung
Board Type=EAC,
09/17/2013
Board
20:01:35
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/DA09_PangkalBuluh
voltage GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:11
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:10
No.=0, PassNo=255, Su
Water Immersed
2374 AlarmBBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:05
No.=0, PassNo=255, Su
Smog Alarm2370
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:05
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=EAC,
09/17/2013
Board
19:13:44
No.=0, PassNo=255, Su
Low Humidity
2382
Alarm BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=EAC,
09/17/2013
Board
19:13:42
No.=0, PassNo=255, Su
Low Temperature
2378 Alarm
BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=EAC,
09/17/2013
Board
19:13:42
No.=0, PassNo=255, Su
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
17:29:23
No.=0, PassNo=255,
Genset Failure
6456Alarm BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
13:56:43
No.=0, PassNo=255,
BTS3012 Boolean31
6482
Alarm
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
13:44:12
No.=0, PassNo=255,
Fan Alarm 2354
BBBL3/DF50_BatuBeriga
GBTS
Site No.=2, DF50_BatuBeriga
Board Type=PMU,
09/17/2013
Board
06:52:11
No.=0, PassNo=255, Su
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:02:23
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:02:35
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:04:00
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:05:38
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:07:20
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:07:48
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:08:20
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:11:15
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:13:34
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:13:45
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:13:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
00:13:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:15:18
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:17:38
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:15:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:19:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:19:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:18:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:13:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:20:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:20:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:20:26
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:21:52
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:22:20
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:22:19
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:22:34
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:22:58
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:23:11
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:26:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
00:27:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:27:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:26:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:46:12
Subsystem
No.=0, E1/T1
No.=0
Port No

er than 09/17/2013 23:59:59.Maintenance status = NORMAL.Time mode = NE time.Log type = Generation log.Alarm Source = BBBL3.
Clearance Time(NT)
Acknowledgement
Acknowledgement
Time(ST) User
09/17/2013 09/17/2013
00:02:25 00:02:40
< System operator >
09/17/2013 09/17/2013
00:02:36 00:37:12
< System operator >
09/17/2013 09/17/2013
00:04:04 00:37:12
< System operator >
09/17/2013 09/17/2013
00:05:39 00:37:12
< System operator >
09/17/2013 09/17/2013
00:07:22 00:37:12
< System operator >
09/17/2013 09/17/2013
00:07:50 00:37:12
< System operator >
09/17/2013 09/17/2013
00:08:22 00:37:12
< System operator >
09/17/2013 09/17/2013
00:11:17 00:37:12
< System operator >
09/17/2013 09/17/2013
00:13:36 00:37:12
< System operator >
09/17/2013 09/17/2013
00:13:47 00:37:12
< System operator >
09/17/2013 09/17/2013
00:13:58 00:37:12
< System operator >
09/17/2013 09/17/2013
00:14:13 01:27:43
< System operator >
09/17/2013 09/17/2013
00:16:57 00:37:12
< System operator >
09/17/2013 09/17/2013
00:17:40 00:37:12
< System operator >
09/17/2013 09/17/2013
00:19:08 00:37:12
< System operator >
09/17/2013 09/17/2013
00:19:18 00:37:12
< System operator >
09/17/2013 09/17/2013
00:19:49 01:27:43
< System operator >
09/17/2013 09/17/2013
00:20:05 00:37:12
< System operator >
09/17/2013 09/17/2013
00:20:23 00:37:12
< System operator >
09/17/2013 09/17/2013
00:21:27 01:27:43
< System operator >
09/17/2013 09/17/2013
00:21:39 00:37:12
< System operator >
09/17/2013 09/17/2013
00:21:47 00:37:12
< System operator >
09/17/2013 09/17/2013
00:21:54 00:37:12
< System operator >
09/17/2013 09/17/2013
00:22:22 00:37:12
< System operator >
09/17/2013 09/17/2013
00:22:24 00:37:12
< System operator >
09/17/2013 09/17/2013
00:22:39 00:37:12
< System operator >
09/17/2013 09/17/2013
00:22:49 01:27:43
< System operator >
09/17/2013 09/17/2013
00:23:00 00:37:12
< System operator >
09/17/2013 09/17/2013
00:23:13 01:27:43
< System operator >
09/17/2013 09/17/2013
00:26:53 00:37:12
< System operator >
09/17/2013 09/17/2013
00:27:52 01:27:43
< System operator >
09/17/2013 09/17/2013
00:27:57 01:27:43
< System operator >
09/17/2013 09/17/2013
00:28:16 01:27:43
< System operator >
09/17/2013 09/17/2013
00:46:25 02:12:45
< System operator >

on log.Alarm Source = BBBL3.

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:46:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:46:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
00:46:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:46:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
00:50:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:50:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:50:56
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:53:31
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:54:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:54:22
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:55:00
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
00:55:31
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
00:54:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
00:54:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:54:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:54:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
00:58:56
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
00:59:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:02:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:01:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:09:13
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:12:39
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:13:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:12:58
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:13:40
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:11:07
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:13:19
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:15:07
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:14:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:17:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:17:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:17:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:17:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:17:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:17:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:17:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:17:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:19:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:24:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:21:14
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:26:53
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:27:58
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:28:34
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:21:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:26:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:30:22
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:14:53
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:30:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:31:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:32:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:33:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:35:56
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
00:46:49 01:27:43
< System operator >
09/17/2013 09/17/2013
00:46:50 01:27:43
< System operator >
09/17/2013 09/17/2013
00:47:48 01:27:43
< System operator >
09/17/2013 09/17/2013
00:47:50 01:27:43
< System operator >
09/17/2013 09/17/2013
00:51:07 01:27:43
< System operator >
09/17/2013 09/17/2013
00:51:09 01:27:43
< System operator >
09/17/2013 09/17/2013
00:51:16 02:49:41
< System operator >
09/17/2013 09/17/2013
00:53:33 01:27:43
< System operator >
09/17/2013 09/17/2013
00:54:21 01:27:43
< System operator >
09/17/2013 09/17/2013
00:54:23 01:27:43
< System operator >
09/17/2013 09/17/2013
00:55:03 01:27:43
< System operator >
09/17/2013 09/17/2013
00:55:33 01:27:43
< System operator >
09/17/2013 09/17/2013
00:56:11 01:27:43
< System operator >
09/17/2013 09/17/2013
00:57:05 01:27:43
< System operator >
09/17/2013 09/17/2013
00:57:41 01:27:43
< System operator >
09/17/2013 09/17/2013
00:58:16 01:48:52
< System operator >
09/17/2013 09/17/2013
01:00:00 01:27:43
< System operator >
09/17/2013 09/17/2013
01:00:43 01:27:43
< System operator >
09/17/2013 09/17/2013
01:03:26 01:27:43
< System operator >
09/17/2013 09/17/2013
01:04:35 01:27:43
< System operator >
09/17/2013 09/17/2013
01:10:24 01:27:43
< System operator >
09/17/2013 09/17/2013
01:12:44 01:27:43
< System operator >
09/17/2013 09/17/2013
01:13:32 01:27:43
< System operator >
09/17/2013 09/17/2013
01:13:33 01:48:52
< System operator >
09/17/2013 09/17/2013
01:13:42 01:27:43
< System operator >
09/17/2013 09/17/2013
01:14:51 01:27:43
< System operator >
09/17/2013 09/17/2013
01:15:06 01:27:43
< System operator >
09/17/2013 09/17/2013
01:15:12 02:12:45
< System operator >
09/17/2013 09/17/2013
01:16:14 01:27:43
< System operator >
09/17/2013 09/17/2013
01:17:02 01:27:43
< System operator >
09/17/2013 09/17/2013
01:17:46 01:48:52
< System operator >
09/17/2013 09/17/2013
01:17:52 01:48:52
< System operator >
09/17/2013 09/17/2013
01:17:52 01:48:52
< System operator >
09/17/2013 09/17/2013
01:17:52 01:48:52
< System operator >
09/17/2013 09/17/2013
01:17:52 01:27:43
< System operator >
09/17/2013 09/17/2013
01:18:14 01:27:43
< System operator >
09/17/2013 09/17/2013
01:19:14 01:48:52
< System operator >
09/17/2013 09/17/2013
01:19:34 01:48:52
< System operator >
09/17/2013 09/17/2013
01:19:34 01:48:52
< System operator >
09/17/2013 09/17/2013
01:19:34 01:48:52
< System operator >
09/17/2013 09/17/2013
01:19:34 01:27:43
< System operator >
09/17/2013 09/17/2013
01:20:34 01:27:43
< System operator >
09/17/2013 09/17/2013
01:24:45 01:27:43
< System operator >
09/17/2013 09/17/2013
01:25:32 05:21:54
< System operator >
09/17/2013 09/17/2013
01:26:55 01:48:52
< System operator >
09/17/2013 09/17/2013
01:28:00 01:48:52
< System operator >
09/17/2013 09/17/2013
01:28:36 01:48:52
< System operator >
09/17/2013 09/17/2013
01:29:02 01:48:52
< System operator >
09/17/2013 09/17/2013
01:29:20 01:48:52
< System operator >
09/17/2013 09/17/2013
01:30:27 01:48:52
< System operator >
09/17/2013 09/17/2013
01:30:31 01:48:52
< System operator >
09/17/2013 09/17/2013
01:31:17 01:48:52
< System operator >
09/17/2013 09/17/2013
01:33:29 02:12:45
< System operator >
09/17/2013 09/17/2013
01:33:39 01:48:52
< System operator >
09/17/2013 09/17/2013
01:35:06 01:48:52
< System operator >
09/17/2013 09/17/2013
01:35:57 01:48:52
< System operator >

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:35:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:36:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:36:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:36:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:36:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:36:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:37:33
No.=0, PassNo=255, S
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:34:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:33:59
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:30:32
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:36:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:39:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:17:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:39:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:39:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:40:29
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:40:22
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:41:14
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:39:14
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:41:53
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:41:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:42:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:40:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:43:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:43:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:43:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:45:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:46:06
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:36:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
01:46:50
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:41:41
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:47:00
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:47:01
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:47:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:48:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:50:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:51:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:51:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:52:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:52:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:52:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:49:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:40:27
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:48:18
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:52:35
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:52:55
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:52:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
01:52:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
01:52:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:52:24
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
01:36:08 02:12:45
< System operator >
09/17/2013 09/17/2013
01:36:28 01:48:52
< System operator >
09/17/2013 09/17/2013
01:36:35 01:48:52
< System operator >
09/17/2013 09/17/2013
01:36:37 01:48:52
< System operator >
09/17/2013 09/17/2013
01:36:49 01:48:52
< System operator >
09/17/2013 09/17/2013
01:36:49 01:48:52
< System operator >
09/17/2013 09/17/2013
01:36:49 01:48:52
< System operator >
09/17/2013 09/17/2013
01:37:35 01:48:52
< System operator >
09/17/2013 09/17/2013
01:38:39 04:27:36
< System operator >
09/17/2013 09/17/2013
01:39:00 05:21:54
< System operator >
09/17/2013 09/17/2013
01:39:12 01:48:52
< System operator >
09/17/2013 09/17/2013
01:39:26 01:48:52
< System operator >
09/17/2013 09/17/2013
01:39:37 01:48:52
< System operator >
09/17/2013 09/17/2013
01:39:58 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:02 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:12 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:28 02:12:45
< System operator >
09/17/2013 09/17/2013
01:40:28 02:12:45
< System operator >
09/17/2013 09/17/2013
01:40:28 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:28 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:28 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:31 01:48:52
< System operator >
09/17/2013 09/17/2013
01:40:56 01:48:52
< System operator >
09/17/2013 09/17/2013
01:41:16 01:48:52
< System operator >
09/17/2013 09/17/2013
01:41:39 01:48:52
< System operator >
09/17/2013 09/17/2013
01:41:57 01:48:52
< System operator >
09/17/2013 09/17/2013
01:41:58 01:48:52
< System operator >
09/17/2013 09/17/2013
01:43:05 01:48:52
< System operator >
09/17/2013 09/17/2013
01:43:33 02:12:45
< System operator >
09/17/2013 09/17/2013
01:43:41 01:48:52
< System operator >
09/17/2013 09/17/2013
01:44:10 02:12:45
< System operator >
09/17/2013 09/17/2013
01:44:24 01:48:52
< System operator >
09/17/2013 09/17/2013
01:46:07 05:21:54
< System operator >
09/17/2013 09/17/2013
01:46:11 01:48:52
< System operator >
09/17/2013 09/17/2013
01:46:44 01:48:52
< System operator >
09/17/2013 09/17/2013
01:46:52 02:12:45
< System operator >
09/17/2013 09/17/2013
01:46:58 01:48:52
< System operator >
09/17/2013 09/17/2013
01:47:52 02:12:45
< System operator >
09/17/2013 09/17/2013
01:48:15 01:48:52
< System operator >
09/17/2013 09/17/2013
01:48:51 02:12:45
< System operator >
09/17/2013 09/17/2013
01:49:43 02:12:45
< System operator >
09/17/2013 09/17/2013
01:50:34 02:12:45
< System operator >
09/17/2013 09/17/2013
01:51:24 05:21:54
< System operator >
09/17/2013 09/17/2013
01:51:45 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:16 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:16 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:25 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:26 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:37 02:12:45
< System operator >
09/17/2013 09/17/2013
01:52:53 02:12:45
< System operator >
09/17/2013 09/17/2013
01:53:01 04:27:36
< System operator >
09/17/2013 09/17/2013
01:54:04 02:12:45
< System operator >
09/17/2013 09/17/2013
01:54:15 02:49:41
< System operator >
09/17/2013 09/17/2013
01:58:50 02:12:45
< System operator >
09/17/2013 09/17/2013
01:59:28 02:12:45
< System operator >
09/17/2013 09/17/2013
02:00:30 02:12:45
< System operator >

Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major

PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
02:00:42
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
02:00:47
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:58:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:57:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:01:35
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
01:59:23
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:01:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:02:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:03:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:02:54
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
02:04:04
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
02:01:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
01:52:15
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
02:01:45
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:06:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:06:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:06:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:06:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:04:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:06:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:08:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:12:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:16:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:16:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:15:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
02:06:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:17:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:17:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:17:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
02:18:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:19:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:20:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:17:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:21:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:20:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:20:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:23:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:23:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:22:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:24:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:24:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:25:17
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:24:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:26:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:26:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:27:58
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
02:28:21
No.=0, PassNo=255,

09/17/2013 09/17/2013
02:00:44 02:12:45
< System operator >
09/17/2013 09/17/2013
02:00:49 03:28:28
< System operator >
09/17/2013 09/17/2013
02:00:50 02:12:45
< System operator >
09/17/2013 -02:00:51 09/17/2013 09/17/2013
02:01:07 02:12:45
< System operator >
09/17/2013 09/17/2013
02:01:07 02:12:45
< System operator >
09/17/2013 09/17/2013
02:01:07 02:12:45
< System operator >
09/17/2013 09/17/2013
02:01:41 02:12:45
< System operator >
09/17/2013 09/17/2013
02:01:43 02:12:45
< System operator >
09/17/2013 09/17/2013
02:02:04 02:12:45
< System operator >
09/17/2013 09/17/2013
02:03:27 02:12:45
< System operator >
09/17/2013 09/17/2013
02:03:49 02:12:45
< System operator >
09/17/2013 09/17/2013
02:04:05 02:49:41
< System operator >
09/17/2013 09/17/2013
02:04:06 04:27:36
< System operator >
09/17/2013 09/17/2013
02:04:18 02:12:45
< System operator >
09/17/2013 09/17/2013
02:04:24 02:12:45
< System operator >
09/17/2013 09/17/2013
02:05:37 02:12:45
< System operator >
09/17/2013 -02:05:42 09/17/2013 09/17/2013
02:06:11 03:28:28
< System operator >
09/17/2013 09/17/2013
02:06:11 03:28:28
< System operator >
09/17/2013 09/17/2013
02:06:11 02:49:41
< System operator >
09/17/2013 09/17/2013
02:06:11 02:49:41
< System operator >
09/17/2013 09/17/2013
02:06:11 02:49:41
< System operator >
09/17/2013 09/17/2013
02:06:12 03:28:28
< System operator >
09/17/2013 09/17/2013
02:06:12 02:49:41
< System operator >
09/17/2013 09/17/2013
02:06:12 02:12:45
< System operator >
09/17/2013 09/17/2013
02:06:12 02:12:45
< System operator >
09/17/2013 09/17/2013
02:06:15 02:49:41
< System operator >
09/17/2013 09/17/2013
02:08:46 02:12:45
< System operator >
09/17/2013 09/17/2013
02:11:59 02:12:45
< System operator >
09/17/2013 09/17/2013
02:15:40 02:49:41
< System operator >
09/17/2013 09/17/2013
02:16:50 02:49:41
< System operator >
09/17/2013 09/17/2013
02:17:06 02:49:41
< System operator >
09/17/2013 09/17/2013
02:17:36 02:49:41
< System operator >
09/17/2013 09/17/2013
02:17:36 02:49:41
< System operator >
09/17/2013 09/17/2013
02:17:38 04:27:36
< System operator >
09/17/2013 09/17/2013
02:17:42 02:49:41
< System operator >
09/17/2013 09/17/2013
02:18:19 02:49:41
< System operator >
09/17/2013 09/17/2013
02:19:41 02:49:41
< System operator >
09/17/2013 09/17/2013
02:19:56 02:49:41
< System operator >
09/17/2013 09/17/2013
02:20:42 05:21:54
< System operator >
09/17/2013 09/17/2013
02:21:35 02:49:41
< System operator >
09/17/2013 09/17/2013
02:22:04 02:49:41
< System operator >
09/17/2013 09/17/2013
02:22:22 02:49:41
< System operator >
09/17/2013 09/17/2013
02:22:29 02:49:41
< System operator >
09/17/2013 09/17/2013
02:23:09 02:49:41
< System operator >
09/17/2013 09/17/2013
02:23:41 02:49:41
< System operator >
09/17/2013 09/17/2013
02:23:41 02:49:41
< System operator >
09/17/2013 09/17/2013
02:24:44 02:49:41
< System operator >
09/17/2013 09/17/2013
02:25:39 02:49:41
< System operator >
09/17/2013 09/17/2013
02:25:47 04:27:36
< System operator >
09/17/2013 09/17/2013
02:25:54 02:49:41
< System operator >
09/17/2013 09/17/2013
02:26:23 02:49:41
< System operator >
09/17/2013 09/17/2013
02:26:55 02:49:41
< System operator >
09/17/2013 09/17/2013
02:28:16 02:49:41
< System operator >
09/17/2013 09/17/2013
02:28:24 02:49:41
< System operator >

Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Major
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:28:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:29:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:29:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:29:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
02:19:54
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
02:30:41
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:30:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:30:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:29:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:31:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:31:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:31:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:34:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:33:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:34:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:39:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:41:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:44:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:45:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:47:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:52:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:55:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:56:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
02:30:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:02:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:02:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
01:01:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:04:15
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
03:12:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
03:10:07
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:13:44
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
03:12:28
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:03:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:14:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:14:43
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
03:18:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
03:19:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
03:19:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
03:19:55
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:22:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:02:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:21:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
02:06:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:13:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:16:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:16:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:06:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:25:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:14:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
02:02:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:26:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:26:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:26:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:26:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:13:43
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
02:29:02 05:21:54
< System operator >
09/17/2013 09/17/2013
02:29:28 02:49:41
< System operator >
09/17/2013 09/17/2013
02:29:35 02:49:41
< System operator >
09/17/2013 09/17/2013
02:29:51 02:49:41
< System operator >
09/17/2013 09/17/2013
02:30:14 02:49:41
< System operator >
09/17/2013 09/17/2013
02:30:43 03:28:28
< System operator >
09/17/2013 09/17/2013
02:30:46 02:49:41
< System operator >
09/17/2013 09/17/2013
02:30:58 02:49:41
< System operator >
09/17/2013 09/17/2013
02:30:58 02:49:41
< System operator >
09/17/2013 09/17/2013
02:31:42 05:21:54
< System operator >
09/17/2013 09/17/2013
02:32:32 05:21:54
< System operator >
09/17/2013 09/17/2013
02:32:33 05:21:54
< System operator >
09/17/2013 09/17/2013
02:34:54 02:49:41
< System operator >
09/17/2013 09/17/2013
02:38:42 05:21:54
< System operator >
09/17/2013 09/17/2013
02:39:03 05:21:54
< System operator >
09/17/2013 09/17/2013
02:40:40 02:49:41
< System operator >
09/17/2013 09/17/2013
02:42:47 02:49:41
< System operator >
09/17/2013 09/17/2013
02:44:38 02:49:41
< System operator >
09/17/2013 09/17/2013
02:46:28 02:49:41
< System operator >
09/17/2013 09/17/2013
02:47:37 03:28:28
< System operator >
09/17/2013 09/17/2013
02:53:16 03:28:28
< System operator >
09/17/2013 09/17/2013
02:56:29 03:28:28
< System operator >
09/17/2013 09/17/2013
02:57:56 03:28:28
< System operator >
09/17/2013 09/17/2013
03:02:26 03:28:28
< System operator >
09/17/2013 09/17/2013
03:02:40 03:28:28
< System operator >
09/17/2013 09/17/2013
03:04:06 03:28:28
< System operator >
09/17/2013 09/17/2013
03:04:35 03:28:28
< System operator >
09/17/2013 09/17/2013
03:04:47 05:21:54
< System operator >
09/17/2013 09/17/2013
03:12:04 03:28:28
< System operator >
09/17/2013 09/17/2013
03:12:25 03:28:28
< System operator >
09/17/2013 09/17/2013
03:13:44 03:28:28
< System operator >
09/17/2013 09/17/2013
03:14:44 03:28:28
< System operator >
09/17/2013 09/17/2013
03:15:25 03:28:28
< System operator >
09/17/2013 09/17/2013
03:16:05 05:21:54
< System operator >
09/17/2013 09/17/2013
03:16:44 05:21:54
< System operator >
09/17/2013 09/17/2013
03:16:45 03:28:28
< System operator >
09/17/2013 09/17/2013
03:18:29 03:28:28
< System operator >
09/17/2013 09/17/2013
03:19:45 03:28:28
< System operator >
09/17/2013 09/17/2013
03:19:52 03:28:28
< System operator >
09/17/2013 09/17/2013
03:20:01 06:16:04
< System operator >
09/17/2013 09/17/2013
03:22:53 03:28:28
< System operator >
09/17/2013 09/17/2013
03:23:29 04:27:36
< System operator >
09/17/2013 09/17/2013
03:23:29 04:27:36
< System operator >
09/17/2013 09/17/2013
03:23:44 04:27:36
< System operator >
09/17/2013 -03:23:45 09/17/2013 -03:24:06 09/17/2013 09/17/2013
03:24:06 06:16:04
< System operator >
09/17/2013 09/17/2013
03:24:56 04:27:36
< System operator >
09/17/2013 09/17/2013
03:25:30 03:28:28
< System operator >
09/17/2013 09/17/2013
03:26:06 04:27:36
< System operator >
09/17/2013 09/17/2013
03:26:06 04:27:36
< System operator >
09/17/2013 09/17/2013
03:26:11 03:28:28
< System operator >
09/17/2013 09/17/2013
03:26:13 03:28:28
< System operator >
09/17/2013 09/17/2013
03:26:14 03:28:28
< System operator >
09/17/2013 09/17/2013
03:26:26 03:28:28
< System operator >
09/17/2013 09/17/2013
03:26:45 04:27:36
< System operator >

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Critical
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
02:01:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:26:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:26:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:27:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:27:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:26:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:27:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:28:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:28:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:28:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:29:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:29:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:27:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:29:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:29:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:29:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:30:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:30:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:30:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:30:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:30:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:30:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:31:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:31:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:31:17
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:31:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:31:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:30:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:30:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:32:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:32:14
Subsystem
No.=0, E1/T1
No.=0
Port No
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 03:25:03
Rectifier module
2406 fault BBBL3/DF43_Guntung
GBTS
Site No.=1, DF43_Guntung
Board Type=EAC,
09/17/2013
Board
03:33:02
No.=0, PassNo=255, Sub
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:32:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:32:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:32:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:32:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:35:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:35:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:36:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:36:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:36:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:38:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:37:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:37:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:37:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:37:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:16:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:38:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:38:55
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
03:26:45 04:27:36
< System operator >
09/17/2013 09/17/2013
03:27:02 04:27:36
< System operator >
09/17/2013 09/17/2013
03:27:02 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:11 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:28 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:31 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:27:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:27:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:27:38 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:38 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:44 03:28:28
< System operator >
09/17/2013 09/17/2013
03:27:56 03:28:28
< System operator >
09/17/2013 09/17/2013
03:28:07 04:27:36
< System operator >
09/17/2013 09/17/2013
03:28:47 04:27:36
< System operator >
09/17/2013 09/17/2013
03:28:52 04:27:36
< System operator >
09/17/2013 09/17/2013
03:29:13 04:27:36
< System operator >
09/17/2013 09/17/2013
03:29:25 04:27:36
< System operator >
09/17/2013 09/17/2013
03:29:28 04:27:36
< System operator >
09/17/2013 09/17/2013
03:29:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:29:56 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:00 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:01 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:01 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:01 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:30:49 04:27:36
< System operator >
09/17/2013 09/17/2013
03:31:09 04:27:36
< System operator >
09/17/2013 09/17/2013
03:31:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:31:25 04:27:36
< System operator >
09/17/2013 09/17/2013
03:31:52 04:27:36
< System operator >
09/17/2013 09/17/2013
03:31:57 04:27:36
< System operator >
09/17/2013 09/17/2013
03:32:11 04:27:36
< System operator >
09/17/2013 09/17/2013
03:32:11 04:27:36
< System operator >
09/17/2013 09/17/2013
03:32:22 04:27:36
< System operator >
09/17/2013 09/17/2013
03:32:29 04:27:36
< System operator >
09/17/2013 09/17/2013
03:32:35 04:27:36
< System operator >
09/17/2013 09/17/2013
03:33:37 23:50:52
< System operator >
09/17/2013 09/17/2013
03:35:42 04:27:36
< System operator >
09/17/2013 09/17/2013
03:35:49 04:27:36
< System operator >
09/17/2013 09/17/2013
03:36:03 04:27:36
< System operator >
09/17/2013 09/17/2013
03:36:06 04:27:36
< System operator >
09/17/2013 09/17/2013
03:36:09 04:27:36
< System operator >
09/17/2013 09/17/2013
03:36:16 04:27:36
< System operator >
09/17/2013 09/17/2013
03:36:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:37:34 04:27:36
< System operator >
09/17/2013 09/17/2013
03:37:34 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:11 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:20 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:36 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:42 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:42 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:46 06:16:04
< System operator >
09/17/2013 09/17/2013
03:38:55 04:27:36
< System operator >
09/17/2013 09/17/2013
03:38:58 04:27:36
< System operator >

Minor
Minor
Minor
Minor
Minor
Critical
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:39:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:38:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:39:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:39:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:39:28
Subsystem
No.=0, E1/T1
No.=0
Port No
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 03:39:33
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:39:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:39:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:41:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:39:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:41:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:41:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:41:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:41:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:41:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:44:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A808_Ranggas
GBTS
Site No.=46,227A808_Ranggas
Board Type=DEMU,
09/17/2013Board
03:15:29
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:41:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:47:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:47:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:41:37
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
03:47:45
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:47:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:47:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:48:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:48:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:48:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:41:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:51:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:50:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:51:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:53:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:50:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:51:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:41:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:50:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:54:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:54:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:54:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:55:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:55:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
03:39:24 04:27:36
< System operator >
09/17/2013 09/17/2013
03:39:27 04:27:36
< System operator >
09/17/2013 09/17/2013
03:39:29 04:27:36
< System operator >
09/17/2013 09/17/2013
03:39:29 04:27:36
< System operator >
09/17/2013 09/17/2013
03:39:52 04:27:36
< System operator >
09/17/2013 09/17/2013
03:40:03 04:27:36
< System operator >
09/17/2013 09/17/2013
03:40:13 04:27:36
< System operator >
09/17/2013 09/17/2013
03:40:34 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:11 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:32 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:35 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:36 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:36 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:36 04:27:36
< System operator >
09/17/2013 09/17/2013
03:41:36 04:27:36
< System operator >
09/17/2013 09/17/2013
03:44:13 04:27:36
< System operator >
09/17/2013 09/17/2013
03:44:54 04:27:36
< System operator >
09/17/2013 09/17/2013
03:44:57 04:27:36
< System operator >
09/17/2013 -03:46:32 09/17/2013 09/17/2013
03:47:10 04:27:36
< System operator >
09/17/2013 09/17/2013
03:47:17 04:27:36
< System operator >
09/17/2013 09/17/2013
03:47:19 04:27:36
< System operator >
09/17/2013 09/17/2013
03:47:30 04:27:36
< System operator >
09/17/2013 09/17/2013
03:47:47 05:21:54
< System operator >
09/17/2013 09/17/2013
03:47:51 04:27:36
< System operator >
09/17/2013 09/17/2013
03:47:53 04:27:36
< System operator >
09/17/2013 09/17/2013
03:48:41 04:27:36
< System operator >
09/17/2013 09/17/2013
03:49:51 04:27:36
< System operator >
09/17/2013 09/17/2013
03:49:58 04:27:36
< System operator >
09/17/2013 09/17/2013
03:50:17 04:27:36
< System operator >
09/17/2013 09/17/2013
03:51:26 04:27:36
< System operator >
09/17/2013 09/17/2013
03:51:26 04:27:36
< System operator >
09/17/2013 09/17/2013
03:51:35 04:27:36
< System operator >
09/17/2013 09/17/2013
03:53:31 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:05 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:07 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:14 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:15 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:34 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:34 04:27:36
< System operator >
09/17/2013 09/17/2013
03:54:59 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:22 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:22 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:30 05:21:54
< System operator >
09/17/2013 09/17/2013
03:55:30 05:21:54
< System operator >
09/17/2013 09/17/2013
03:55:30 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:30 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:30 04:27:36
< System operator >
09/17/2013 09/17/2013
03:55:52 04:27:36
< System operator >
09/17/2013 09/17/2013
03:56:16 04:27:36
< System operator >
09/17/2013 09/17/2013
03:56:16 04:27:36
< System operator >

Critical
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Critical
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

Ater OML Faulty


20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 03:54:44
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:56:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:56:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:56:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:58:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:58:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:58:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:58:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
03:59:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:59:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:58:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:58:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:00:30
Subsystem
No.=0, E1/T1
No.=0
Port No
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 03:58:47
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:00:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:01:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:02:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:02:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:03:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:03:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:03:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:03:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:03:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:03:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:04:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:04:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:05:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:04:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:06:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:06:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:07:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:06:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:07:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:07:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:07:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:08:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:08:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:09:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:08:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:09:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:10:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:10:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:07:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:03:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:03:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:11:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:11:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:12:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:13:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:15:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:18:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:12:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:19:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:23:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:08:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:23:56
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
03:56:24 04:27:36
< System operator >
09/17/2013 09/17/2013
03:56:31 04:27:36
< System operator >
09/17/2013 09/17/2013
03:58:37 04:27:36
< System operator >
09/17/2013 09/17/2013
03:58:38 04:27:36
< System operator >
09/17/2013 09/17/2013
03:58:39 04:27:36
< System operator >
09/17/2013 09/17/2013
03:58:40 04:27:36
< System operator >
09/17/2013 09/17/2013
03:59:03 04:27:36
< System operator >
09/17/2013 09/17/2013
03:59:04 04:27:36
< System operator >
09/17/2013 09/17/2013
03:59:40 06:16:04
< System operator >
09/17/2013 09/17/2013
03:59:40 04:27:36
< System operator >
09/17/2013 09/17/2013
03:59:55 04:27:36
< System operator >
09/17/2013 09/17/2013
03:59:55 04:27:36
< System operator >
09/17/2013 09/17/2013
04:00:33 04:27:36
< System operator >
09/17/2013 09/17/2013
04:00:39 04:27:36
< System operator >
09/17/2013 09/17/2013
04:01:07 04:27:36
< System operator >
09/17/2013 09/17/2013
04:01:49 04:27:36
< System operator >
09/17/2013 09/17/2013
04:02:27 04:27:36
< System operator >
09/17/2013 09/17/2013
04:02:55 04:27:36
< System operator >
09/17/2013 09/17/2013
04:03:26 05:21:54
< System operator >
09/17/2013 09/17/2013
04:03:26 05:21:54
< System operator >
09/17/2013 09/17/2013
04:03:26 04:27:36
< System operator >
09/17/2013 09/17/2013
04:03:26 04:27:36
< System operator >
09/17/2013 09/17/2013
04:03:31 04:27:36
< System operator >
09/17/2013 09/17/2013
04:03:34 05:21:54
< System operator >
09/17/2013 09/17/2013
04:04:44 04:27:36
< System operator >
09/17/2013 09/17/2013
04:05:05 04:27:36
< System operator >
09/17/2013 09/17/2013
04:05:16 04:27:36
< System operator >
09/17/2013 09/17/2013
04:05:29 04:27:36
< System operator >
09/17/2013 09/17/2013
04:06:40 04:27:36
< System operator >
09/17/2013 09/17/2013
04:06:45 04:27:36
< System operator >
09/17/2013 09/17/2013
04:07:24 04:27:36
< System operator >
09/17/2013 09/17/2013
04:07:27 04:27:36
< System operator >
09/17/2013 09/17/2013
04:07:35 04:27:36
< System operator >
09/17/2013 09/17/2013
04:07:46 04:27:36
< System operator >
09/17/2013 09/17/2013
04:07:46 04:27:36
< System operator >
09/17/2013 09/17/2013
04:08:41 04:27:36
< System operator >
09/17/2013 09/17/2013
04:08:48 04:27:36
< System operator >
09/17/2013 09/17/2013
04:09:06 04:27:36
< System operator >
09/17/2013 09/17/2013
04:09:06 05:21:54
< System operator >
09/17/2013 09/17/2013
04:09:57 04:27:36
< System operator >
09/17/2013 09/17/2013
04:10:06 04:27:36
< System operator >
09/17/2013 09/17/2013
04:10:15 05:21:54
< System operator >
09/17/2013 09/17/2013
04:10:18 05:21:54
< System operator >
09/17/2013 09/17/2013
04:10:22 04:27:36
< System operator >
09/17/2013 09/17/2013
04:11:09 04:27:36
< System operator >
09/17/2013 09/17/2013
04:11:23 04:27:36
< System operator >
09/17/2013 09/17/2013
04:11:57 04:27:36
< System operator >
09/17/2013 09/17/2013
04:12:20 04:27:36
< System operator >
09/17/2013 09/17/2013
04:13:14 04:27:36
< System operator >
09/17/2013 09/17/2013
04:15:38 04:27:36
< System operator >
09/17/2013 09/17/2013
04:18:41 04:27:36
< System operator >
09/17/2013 09/17/2013
04:19:26 04:27:36
< System operator >
09/17/2013 09/17/2013
04:19:37 06:16:04
< System operator >
09/17/2013 09/17/2013
04:23:46 04:27:36
< System operator >
09/17/2013 09/17/2013
04:23:48 05:21:54
< System operator >
09/17/2013 09/17/2013
04:24:14 05:21:54
< System operator >

Minor
Minor
Major
Critical
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:23:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:16:30
Subsystem
No.=0, E1/T1
No.=0
Port No
Over Temperature
2376 Alarm
BBBL3/D648_AirGergas[HUB]
GBTS
Site No.=8, D648_AirGergas[HUB]
Board Type=EAC,
09/17/2013
Board
03:31:08
No.=0, PassNo=255, Sub
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 04:25:33
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:28:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:29:30
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
04:31:26
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:22:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:32:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:33:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:39:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:19:56
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
04:44:29
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
04:44:41
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:44:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:44:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:44:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:44:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:45:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:45:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:45:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:45:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:45:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:46:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:46:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:46:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:46:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:47:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:47:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:48:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:44:45
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
04:49:01
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:44:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:24:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:50:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:51:08
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
04:52:13
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:53:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:50:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:53:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:53:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:54:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:55:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:56:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:56:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
04:56:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:56:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:58:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:00:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:00:10
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
04:24:16 05:21:54
< System operator >
09/17/2013 09/17/2013
04:24:45 04:27:36
< System operator >
09/17/2013 09/17/2013
04:26:15 06:16:04
< System operator >
09/17/2013 09/17/2013
04:26:33 14:03:12
< System operator >
09/17/2013 09/17/2013
04:29:16 06:16:04
< System operator >
09/17/2013 09/17/2013
04:30:13 05:21:54
< System operator >
09/17/2013 09/17/2013
04:31:28 05:21:54
< System operator >
09/17/2013 09/17/2013
04:31:58 05:21:54
< System operator >
09/17/2013 09/17/2013
04:32:37 06:16:04
< System operator >
09/17/2013 09/17/2013
04:34:04 05:21:54
< System operator >
09/17/2013 09/17/2013
04:40:12 05:21:54
< System operator >
09/17/2013 09/17/2013
04:42:18 06:16:04
< System operator >
09/17/2013 09/17/2013
04:44:31 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:43 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:46 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:46 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:46 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:52 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:52 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:52 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:52 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:52 05:21:54
< System operator >
09/17/2013 09/17/2013
04:44:58 05:21:54
< System operator >
09/17/2013 09/17/2013
04:45:17 05:21:54
< System operator >
09/17/2013 09/17/2013
04:45:25 05:21:54
< System operator >
09/17/2013 09/17/2013
04:45:43 05:21:54
< System operator >
09/17/2013 09/17/2013
04:46:01 05:21:54
< System operator >
09/17/2013 09/17/2013
04:46:09 05:21:54
< System operator >
09/17/2013 09/17/2013
04:46:30 07:04:59
< System operator >
09/17/2013 09/17/2013
04:46:47 05:21:54
< System operator >
09/17/2013 09/17/2013
04:46:47 05:21:54
< System operator >
09/17/2013 09/17/2013
04:46:57 05:21:54
< System operator >
09/17/2013 09/17/2013
04:47:04 05:21:54
< System operator >
09/17/2013 09/17/2013
04:47:45 05:21:54
< System operator >
09/17/2013 09/17/2013
04:47:55 05:21:54
< System operator >
09/17/2013 09/17/2013
04:48:42 06:16:04
< System operator >
09/17/2013 09/17/2013
04:48:57 05:21:54
< System operator >
09/17/2013 09/17/2013
04:49:03 05:21:54
< System operator >
09/17/2013 09/17/2013
04:49:04 05:21:54
< System operator >
09/17/2013 09/17/2013
04:50:17 05:21:54
< System operator >
09/17/2013 09/17/2013
04:50:34 05:21:54
< System operator >
09/17/2013 09/17/2013
04:51:20 05:21:54
< System operator >
09/17/2013 09/17/2013
04:52:15 06:16:04
< System operator >
09/17/2013 09/17/2013
04:53:02 05:21:54
< System operator >
09/17/2013 09/17/2013
04:53:16 05:21:54
< System operator >
09/17/2013 09/17/2013
04:53:19 05:21:54
< System operator >
09/17/2013 09/17/2013
04:54:07 05:21:54
< System operator >
09/17/2013 -04:55:50 09/17/2013 09/17/2013
04:56:07 05:21:54
< System operator >
09/17/2013 09/17/2013
04:57:44 05:21:54
< System operator >
09/17/2013 09/17/2013
04:57:46 05:21:54
< System operator >
09/17/2013 09/17/2013
04:57:50 05:21:54
< System operator >
09/17/2013 09/17/2013
04:57:51 05:21:54
< System operator >
09/17/2013 09/17/2013
04:58:40 05:21:54
< System operator >
09/17/2013 09/17/2013
05:00:36 18:06:47
< System operator >
09/17/2013 -05:00:45 -

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:50:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:00:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:00:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
04:32:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
03:55:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:02:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:03:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:05:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:04:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:05:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:05:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:05:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:06:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:01:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:06:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:06:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:06:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:06:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:01:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:05:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:07:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:05:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:08:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:07:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:08:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:09:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:12:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:12:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:12:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:12:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:13:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:13:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:13:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:13:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:13:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:12:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:05:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:15:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:15:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:06:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:18:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:18:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:22:14
No.=0, PassNo=255, S
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:08:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:09:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
05:01:11 05:21:54
< System operator >
09/17/2013 09/17/2013
05:01:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:02:06 06:16:04
< System operator >
09/17/2013 09/17/2013
05:02:51 05:21:54
< System operator >
09/17/2013 09/17/2013
05:03:38 05:21:54
< System operator >
09/17/2013 09/17/2013
05:03:51 05:21:54
< System operator >
09/17/2013 09/17/2013
05:04:33 05:21:54
< System operator >
09/17/2013 09/17/2013
05:05:03 05:21:54
< System operator >
09/17/2013 09/17/2013
05:05:44 05:21:54
< System operator >
09/17/2013 09/17/2013
05:05:50 05:21:54
< System operator >
09/17/2013 09/17/2013
05:05:54 05:21:54
< System operator >
09/17/2013 09/17/2013
05:05:54 05:21:54
< System operator >
09/17/2013 09/17/2013
05:06:03 05:21:54
< System operator >
09/17/2013 09/17/2013
05:06:51 06:16:04
< System operator >
09/17/2013 09/17/2013
05:07:03 08:48:47
< System operator >
09/17/2013 09/17/2013
05:07:04 05:21:54
< System operator >
09/17/2013 09/17/2013
05:07:05 05:21:54
< System operator >
09/17/2013 09/17/2013
05:07:05 05:21:54
< System operator >
09/17/2013 09/17/2013
05:07:12 06:16:04
< System operator >
09/17/2013 09/17/2013
05:07:24 05:21:54
< System operator >
09/17/2013 09/17/2013
05:07:43 05:21:54
< System operator >
09/17/2013 09/17/2013
05:09:13 05:21:54
< System operator >
09/17/2013 09/17/2013
05:09:14 06:16:04
< System operator >
09/17/2013 09/17/2013
05:09:44 05:21:54
< System operator >
09/17/2013 09/17/2013
05:10:46 06:16:04
< System operator >
09/17/2013 09/17/2013
05:11:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:12:51 06:16:04
< System operator >
09/17/2013 09/17/2013
05:12:51 06:16:04
< System operator >
09/17/2013 09/17/2013
05:12:51 05:21:54
< System operator >
09/17/2013 09/17/2013
05:12:51 05:21:54
< System operator >
09/17/2013 09/17/2013
05:13:39 06:16:04
< System operator >
09/17/2013 09/17/2013
05:13:39 06:16:04
< System operator >
09/17/2013 09/17/2013
05:13:39 06:16:04
< System operator >
09/17/2013 09/17/2013
05:13:39 05:21:54
< System operator >
09/17/2013 09/17/2013
05:13:39 05:21:54
< System operator >
09/17/2013 09/17/2013
05:14:03 06:16:04
< System operator >
09/17/2013 09/17/2013
05:15:08 05:21:54
< System operator >
09/17/2013 09/17/2013
05:15:36 05:21:54
< System operator >
09/17/2013 09/17/2013
05:16:00 05:21:54
< System operator >
09/17/2013 09/17/2013
05:18:48 06:16:04
< System operator >
09/17/2013 09/17/2013
05:19:08 06:16:04
< System operator >
09/17/2013 09/17/2013
05:19:41 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:20:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:22:18 06:16:04
< System operator >
09/17/2013 -05:23:52 09/17/2013 -05:24:13 09/17/2013 09/17/2013
05:28:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:28:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:28:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:28:43 06:16:04
< System operator >

Minor
Minor
Major
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Major
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:30:21
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
05:31:16
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:31:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:35:09
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:35:25
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:35:37
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:35:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:12:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:38:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:38:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:38:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:38:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:38:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:38:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:39:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:38:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:39:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:39:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:40:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:42:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:42:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:45:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:45:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:45:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:45:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:43:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:39:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:45:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:45:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:46:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:47:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:46:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:48:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:48:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:49:55
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:50:19
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:49:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:52:24
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:52:37
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:45:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:42:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:52:04
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
05:56:15
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
05:53:06
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:01:30
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:01:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:01:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:02:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:04:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:04:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
06:04:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:04:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:04:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:05:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:05:21
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
05:28:43 06:16:04
< System operator >
09/17/2013 09/17/2013
05:30:59 06:16:04
< System operator >
09/17/2013 09/17/2013
05:31:18 07:04:59
< System operator >
09/17/2013 09/17/2013
05:32:19 06:16:04
< System operator >
09/17/2013 09/17/2013
05:35:26 06:16:04
< System operator >
09/17/2013 09/17/2013
05:35:27 06:16:04
< System operator >
09/17/2013 09/17/2013
05:35:39 06:16:04
< System operator >
09/17/2013 09/17/2013
05:37:33 06:16:04
< System operator >
09/17/2013 09/17/2013
05:37:47 06:16:04
< System operator >
09/17/2013 09/17/2013
05:38:31 06:16:04
< System operator >
09/17/2013 09/17/2013
05:38:53 07:50:19
< System operator >
09/17/2013 09/17/2013
05:39:04 07:50:19
< System operator >
09/17/2013 09/17/2013
05:39:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:39:29 06:16:04
< System operator >
09/17/2013 09/17/2013
05:39:34 06:16:04
< System operator >
09/17/2013 09/17/2013
05:39:57 06:16:04
< System operator >
09/17/2013 09/17/2013
05:40:05 07:50:19
< System operator >
09/17/2013 09/17/2013
05:40:25 08:48:47
< System operator >
09/17/2013 09/17/2013
05:41:00 06:16:04
< System operator >
09/17/2013 09/17/2013
05:41:33 06:16:04
< System operator >
09/17/2013 09/17/2013
05:42:47 06:16:04
< System operator >
09/17/2013 09/17/2013
05:42:47 06:16:04
< System operator >
09/17/2013 09/17/2013
05:45:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:45:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:45:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:45:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:45:40 06:16:04
< System operator >
09/17/2013 09/17/2013
05:46:12 06:16:04
< System operator >
09/17/2013 09/17/2013
05:46:31 06:16:04
< System operator >
09/17/2013 09/17/2013
05:46:31 06:16:04
< System operator >
09/17/2013 09/17/2013
05:48:02 06:16:04
< System operator >
09/17/2013 09/17/2013
05:48:25 08:48:47
< System operator >
09/17/2013 09/17/2013
05:48:34 06:16:04
< System operator >
09/17/2013 09/17/2013
05:48:51 06:16:04
< System operator >
09/17/2013 09/17/2013
05:49:47 06:16:04
< System operator >
09/17/2013 09/17/2013
05:49:59 06:16:04
< System operator >
09/17/2013 09/17/2013
05:50:21 06:16:04
< System operator >
09/17/2013 09/17/2013
05:50:22 06:16:04
< System operator >
09/17/2013 09/17/2013
05:52:26 06:16:04
< System operator >
09/17/2013 09/17/2013
05:52:39 06:16:04
< System operator >
09/17/2013 09/17/2013
05:52:57 06:16:04
< System operator >
09/17/2013 09/17/2013
05:53:01 06:16:04
< System operator >
09/17/2013 09/17/2013
05:56:05 06:16:04
< System operator >
09/17/2013 09/17/2013
05:56:17 06:16:04
< System operator >
09/17/2013 09/17/2013
05:57:46 06:16:04
< System operator >
09/17/2013 09/17/2013
06:01:32 07:04:59
< System operator >
09/17/2013 09/17/2013
06:01:34 06:16:04
< System operator >
09/17/2013 09/17/2013
06:01:53 06:16:04
< System operator >
09/17/2013 09/17/2013
06:02:41 06:16:04
< System operator >
09/17/2013 09/17/2013
06:04:19 06:16:04
< System operator >
09/17/2013 09/17/2013
06:04:29 06:16:04
< System operator >
09/17/2013 09/17/2013
06:04:36 06:16:04
< System operator >
09/17/2013 09/17/2013
06:04:46 06:16:04
< System operator >
09/17/2013 09/17/2013
06:05:19 06:16:04
< System operator >
09/17/2013 09/17/2013
06:05:26 07:04:59
< System operator >
09/17/2013 09/17/2013
06:05:28 07:04:59
< System operator >

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Correlative Critical
Alarm
Major
Minor
Minor
Major
Minor
Major
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Major
Minor
Minor
Minor
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:04:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:08:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:08:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:08:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:08:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:52:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:53:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
06:07:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:06:56
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
05:28:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
05:20:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:15:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:16:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:15:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:22:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:22:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:24:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:24:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:24:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:25:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:24:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:26:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:25:08
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
06:27:31
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
06:26:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:30:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
06:32:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:31:41
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:33:13
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:22:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:37:30
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:38:00
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:39:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:39:06
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:44:31
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:44:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:46:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:48:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:48:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:48:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=24,
Slot No.=24,
09/17/2013
Subrack
Subsystem
No=0,
06:47:13
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/DF50_BatuBeriga
GBTS
Site Index=2,
DF50_BatuBeriga
BSC Subrack
09/17/2013
No.=0,06:49:09
BSC Slot No.=24, E1 No.=
AC L1 failure
2410
alarm
BBBL3/DF50_BatuBeriga
GBTS
Site No.=2, DF50_BatuBeriga
Board Type=EAC,
09/17/2013
Board
05:50:26
No.=0, PassNo=255, Sub
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:49:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
06:48:57
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 failure
2410
alarm
BBBL3/DF50_BatuBeriga
GBTS
Site No.=2, DF50_BatuBeriga
Board Type=EAC,
09/17/2013
Board
06:51:35
No.=0, PassNo=255, Sub
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:48:46
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:53:40
No.=0, PassNo=255, S
GSM Cell out
21801
of Service
BBBL3/DF50_BatuBeriga
GBTS
Site Index=2,
LABEL=4650_BatuBeriga-5,
Cell Index=7,
09/17/2013
Alarm Cause=Other
06:48:54
CellIndex=7,
causes,
CGI=510
Site T
GSM Cell out
21801
of Service
BBBL3/DF50_BatuBeriga
GBTS
Site Index=2,
LABEL=4650_BatuBeriga-4,
Cell Index=6,
09/17/2013
Alarm Cause=Other
06:48:54
CellIndex=6,
causes,
CGI=510
Site T
GSM Cell out
21801
of Service
BBBL3/DF50_BatuBeriga
GBTS
Site Index=2,
LABEL=4650_BatuBeriga-6,
Cell Index=8,
09/17/2013
Alarm Cause=Other
06:48:54
CellIndex=8,
causes,
CGI=510
Site T
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
06:55:00
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:59:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
06:53:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:48:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:05:40
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
06:05:29 08:48:47
< System operator >
09/17/2013 09/17/2013
06:08:22 08:48:47
< System operator >
09/17/2013 09/17/2013
06:08:26 06:16:04
< System operator >
09/17/2013 09/17/2013
06:08:42 08:48:47
< System operator >
09/17/2013 09/17/2013
06:08:49 08:48:47
< System operator >
09/17/2013 09/17/2013
06:08:54 06:16:04
< System operator >
09/17/2013 09/17/2013
06:09:15 06:16:04
< System operator >
09/17/2013 09/17/2013
06:14:14 07:04:59
< System operator >
09/17/2013 09/17/2013
06:14:15 07:04:59
< System operator >
09/17/2013 09/17/2013
06:14:41 07:04:59
< System operator >
09/17/2013 09/17/2013
06:14:52 07:04:59
< System operator >
09/17/2013 09/17/2013
06:16:05 07:04:59
< System operator >
09/17/2013 09/17/2013
06:17:02 07:50:19
< System operator >
09/17/2013 09/17/2013
06:17:02 07:50:19
< System operator >
09/17/2013 09/17/2013
06:22:58 07:04:59
< System operator >
09/17/2013 09/17/2013
06:22:58 07:04:59
< System operator >
09/17/2013 09/17/2013
06:24:03 07:04:59
< System operator >
09/17/2013 09/17/2013
06:24:03 07:04:59
< System operator >
09/17/2013 09/17/2013
06:24:03 07:04:59
< System operator >
09/17/2013 09/17/2013
06:25:09 07:04:59
< System operator >
09/17/2013 09/17/2013
06:26:03 07:04:59
< System operator >
09/17/2013 09/17/2013
06:26:09 08:48:47
< System operator >
09/17/2013 09/17/2013
06:26:23 07:04:59
< System operator >
09/17/2013 09/17/2013
06:27:33 07:50:19
< System operator >
09/17/2013 09/17/2013
06:28:14 07:04:59
< System operator >
09/17/2013 09/17/2013
06:31:30 07:04:59
< System operator >
09/17/2013 09/17/2013
06:33:07 07:04:59
< System operator >
09/17/2013 09/17/2013
06:33:13 07:04:59
< System operator >
09/17/2013 09/17/2013
06:33:15 07:04:59
< System operator >
09/17/2013 09/17/2013
06:34:01 07:04:59
< System operator >
09/17/2013 09/17/2013
06:37:55 07:04:59
< System operator >
09/17/2013 09/17/2013
06:38:01 07:04:59
< System operator >
09/17/2013 09/17/2013
06:40:32 07:04:59
< System operator >
09/17/2013 09/17/2013
06:43:41 07:04:59
< System operator >
09/17/2013 09/17/2013
06:44:32 07:04:59
< System operator >
09/17/2013 09/17/2013
06:44:46 07:04:59
< System operator >
09/17/2013 09/17/2013
06:48:44 07:50:19
< System operator >
09/17/2013 09/17/2013
06:48:46 07:04:59
< System operator >
09/17/2013 09/17/2013
06:48:46 07:04:59
< System operator >
09/17/2013 09/17/2013
06:48:47 07:04:59
< System operator >
09/17/2013 09/17/2013
06:50:51 07:04:59
< System operator >
09/17/2013 09/17/2013
06:51:08 07:04:59
< System operator >
09/17/2013 09/17/2013
06:51:08 07:04:59
< System operator >
09/17/2013 09/17/2013
06:51:56 07:04:59
< System operator >
09/17/2013 09/17/2013
06:51:59 07:50:19
< System operator >
09/17/2013 09/17/2013
06:52:50 16:57:41
< System operator >
09/17/2013 09/17/2013
06:53:04 07:04:59
< System operator >
09/17/2013 09/17/2013
06:53:42 07:04:59
< System operator >
09/17/2013 09/17/2013
06:53:49 07:04:59
< System operator >
09/17/2013 09/17/2013
06:53:49 07:04:59
< System operator >
09/17/2013 09/17/2013
06:54:14 07:04:59
< System operator >
09/17/2013 09/17/2013
06:55:01 07:50:19
< System operator >
09/17/2013 09/17/2013
07:00:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:00:24 07:50:19
< System operator >
09/17/2013 09/17/2013
07:00:41 07:50:19
< System operator >
09/17/2013 09/17/2013
07:06:19 08:48:47
< System operator >

Major
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
07:08:41
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:08:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
06:14:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
06:15:16
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
07:17:47
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:23:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:23:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:27:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:27:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:30:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:31:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:32:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:36:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:35:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:36:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:35:56
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:38:44
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
07:38:43
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:41:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:41:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:41:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:01:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:01:08
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
07:41:22
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:41:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:00:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:00:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:41:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:41:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:42:18
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:42:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:43:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:42:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
04:45:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:43:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:45:11
Subsystem
No.=0, E1/T1
No.=0
Port No
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
07:43:32
No.=3, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:42:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:42:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:44:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:44:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:45:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:45:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:45:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:45:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:46:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:47:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:47:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:41:10
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
07:08:45 07:50:19
< System operator >
09/17/2013 09/17/2013
07:09:41 07:50:19
< System operator >
09/17/2013 09/17/2013
07:11:58 07:50:19
< System operator >
09/17/2013 09/17/2013
07:12:19 07:50:19
< System operator >
09/17/2013 09/17/2013
07:17:52 08:48:47
< System operator >
09/17/2013 09/17/2013
07:24:07 07:50:19
< System operator >
09/17/2013 09/17/2013
07:24:42 07:50:19
< System operator >
09/17/2013 09/17/2013
07:27:30 07:50:19
< System operator >
09/17/2013 09/17/2013
07:28:43 07:50:19
< System operator >
09/17/2013 09/17/2013
07:30:50 08:48:47
< System operator >
09/17/2013 09/17/2013
07:33:19 07:50:19
< System operator >
09/17/2013 09/17/2013
07:33:20 08:48:47
< System operator >
09/17/2013 09/17/2013
07:36:36 08:48:47
< System operator >
09/17/2013 09/17/2013
07:36:43 08:48:47
< System operator >
09/17/2013 09/17/2013
07:36:44 08:48:47
< System operator >
09/17/2013 09/17/2013
07:36:44 08:48:47
< System operator >
09/17/2013 09/17/2013
07:39:17 08:48:47
< System operator >
09/17/2013 09/17/2013
07:41:08 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:11 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:12 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:12 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:12 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:41:23 08:48:47
< System operator >
09/17/2013 09/17/2013
07:41:28 07:50:19
< System operator >
09/17/2013 09/17/2013
07:42:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:42:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:42:07 07:50:19
< System operator >
09/17/2013 09/17/2013
07:42:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:42:25 07:50:19
< System operator >
09/17/2013 09/17/2013
07:43:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:43:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:21 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:29 08:48:47
< System operator >
09/17/2013 09/17/2013
07:44:33 07:50:19
< System operator >
09/17/2013 09/17/2013
07:44:33 07:50:19
< System operator >
09/17/2013 09/17/2013
07:45:13 07:50:19
< System operator >
09/17/2013 09/17/2013
07:45:13 07:50:19
< System operator >
09/17/2013 09/17/2013
07:45:22 07:50:19
< System operator >
09/17/2013 09/17/2013
07:45:39 07:50:19
< System operator >
09/17/2013 09/17/2013
07:46:13 07:50:19
< System operator >
09/17/2013 09/17/2013
07:46:46 07:50:19
< System operator >
09/17/2013 09/17/2013
07:47:00 07:50:19
< System operator >
09/17/2013 09/17/2013
07:47:22 07:50:19
< System operator >
09/17/2013 09/17/2013
07:47:43 09:57:09
< System operator >
09/17/2013 09/17/2013
07:48:07 14:03:12
< System operator >

Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:41:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:47:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:47:40
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
07:46:21
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:50:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:53:18
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:54:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:54:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:55:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:18:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:55:18
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
07:54:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:55:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:48:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:17:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:49:21
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
07:56:27
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:59:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
07:58:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:04:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:03:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:04:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:04:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:06:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:06:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:09:25
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
08:09:13
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:14:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:18:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:16:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:20:11
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
08:17:46
No.=0, Board Type=EMU
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:25:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:25:48
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:25:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:25:34
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:26:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:26:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:26:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:26:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:26:56
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:27:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:27:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:27:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
08:28:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:28:49
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
08:29:33
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:29:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
08:31:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:31:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
08:32:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:32:21
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
07:48:07 14:03:12
< System operator >
09/17/2013 09/17/2013
07:48:48 08:48:47
< System operator >
09/17/2013 09/17/2013
07:48:50 11:12:32
< System operator >
09/17/2013 09/17/2013
07:51:13 08:48:47
< System operator >
09/17/2013 09/17/2013
07:51:21 08:48:47
< System operator >
09/17/2013 09/17/2013
07:54:20 08:48:47
< System operator >
09/17/2013 09/18/2013
07:54:53 07:53:42
< System operator >
09/17/2013 09/17/2013
07:54:56 08:48:47
< System operator >
09/17/2013 -07:55:18 09/17/2013 09/17/2013
07:55:22 08:48:47
< System operator >
09/17/2013 -07:55:25 09/17/2013 09/17/2013
07:55:30 22:29:26
< System operator >
09/17/2013 09/17/2013
07:55:36 08:48:47
< System operator >
09/17/2013 09/17/2013
07:56:01 08:48:47
< System operator >
09/17/2013 09/17/2013
07:56:01 08:48:47
< System operator >
09/17/2013 09/17/2013
07:56:22 08:48:47
< System operator >
09/17/2013 09/17/2013
08:01:39 08:48:47
< System operator >
09/17/2013 09/17/2013
08:03:36 08:48:47
< System operator >
09/17/2013 09/17/2013
08:03:36 09:57:09
< System operator >
09/17/2013 09/17/2013
08:04:03 08:48:47
< System operator >
09/17/2013 09/17/2013
08:04:32 08:48:47
< System operator >
09/17/2013 09/17/2013
08:04:49 08:48:47
< System operator >
09/17/2013 09/17/2013
08:05:07 08:48:47
< System operator >
09/17/2013 09/17/2013
08:07:41 09:57:09
< System operator >
09/17/2013 09/17/2013
08:08:03 09:57:09
< System operator >
09/17/2013 09/17/2013
08:09:41 08:48:47
< System operator >
09/17/2013 09/17/2013
08:14:29 08:48:47
< System operator >
09/17/2013 09/17/2013
08:18:03 09:57:09
< System operator >
09/17/2013 09/17/2013
08:19:17 08:48:47
< System operator >
09/17/2013 09/17/2013
08:19:17 08:48:47
< System operator >
09/17/2013 09/17/2013
08:20:35 08:48:47
< System operator >
09/17/2013 09/17/2013
08:21:37 08:48:47
< System operator >
09/17/2013 09/17/2013
08:25:42 08:48:47
< System operator >
09/17/2013 09/17/2013
08:25:50 08:48:47
< System operator >
09/17/2013 09/17/2013
08:26:06 09:57:09
< System operator >
09/17/2013 09/17/2013
08:26:07 08:48:47
< System operator >
09/17/2013 09/17/2013
08:26:14 08:48:47
< System operator >
09/17/2013 09/17/2013
08:26:28 08:48:47
< System operator >
09/17/2013 09/17/2013
08:26:38 08:48:47
< System operator >
09/17/2013 09/17/2013
08:26:54 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:02 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:15 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:15 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:15 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:41 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:41 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:41 08:48:47
< System operator >
09/17/2013 09/17/2013
08:27:41 08:48:47
< System operator >
09/17/2013 09/17/2013
08:29:16 08:48:47
< System operator >
09/17/2013 09/17/2013
08:29:22 08:48:47
< System operator >
09/17/2013 09/17/2013
08:29:35 08:48:47
< System operator >
09/17/2013 09/17/2013
08:29:54 08:48:47
< System operator >
09/17/2013 09/17/2013
08:31:51 08:48:47
< System operator >
09/17/2013 09/17/2013
08:31:59 08:48:47
< System operator >
09/17/2013 09/17/2013
08:33:13 08:48:47
< System operator >
09/17/2013 09/17/2013
08:33:48 09:57:09
< System operator >

Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
08:33:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:33:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:33:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:27:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:35:11
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
08:36:50
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:38:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:38:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:38:21
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:39:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:39:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:39:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:40:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:42:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
08:40:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:45:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:48:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:39:46
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
08:40:02
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
08:54:53
No.=0, PassNo=255, S
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:05:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
08:56:16
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:58:11
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:58:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:58:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:58:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
08:59:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:06:45
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:05:22
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:07:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:07:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:07:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:07:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:07:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:08:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:08:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:08:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:08:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:08:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:09:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:09:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:10:33
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:10:37
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:03:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:04:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:22:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
08:48:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:20:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:20:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:20:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:20:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:48:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:49:21
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:29:21
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:30:26
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:35:43
No.=0, PassNo=255,

09/17/2013 09/17/2013
08:34:07 09:57:09
< System operator >
09/17/2013 09/17/2013
08:34:10 09:57:09
< System operator >
09/17/2013 09/17/2013
08:34:27 09:57:09
< System operator >
09/17/2013 09/17/2013
08:34:27 09:57:09
< System operator >
09/17/2013 09/17/2013
08:35:22 11:12:32
< System operator >
09/17/2013 09/17/2013
08:36:53 09:57:09
< System operator >
09/17/2013 09/17/2013
08:38:11 08:48:47
< System operator >
09/17/2013 09/17/2013
08:38:17 08:48:47
< System operator >
09/17/2013 09/17/2013
08:38:23 09:57:09
< System operator >
09/17/2013 09/17/2013
08:39:47 08:48:47
< System operator >
09/17/2013 09/17/2013
08:39:47 08:48:47
< System operator >
09/17/2013 09/17/2013
08:39:47 08:48:47
< System operator >
09/17/2013 09/17/2013
08:40:03 08:48:47
< System operator >
09/17/2013 09/17/2013
08:42:31 08:48:47
< System operator >
09/17/2013 09/17/2013
08:45:53 09:57:09
< System operator >
09/17/2013 09/17/2013
08:47:45 08:48:47
< System operator >
09/17/2013 09/17/2013
08:48:23 09:57:09
< System operator >
09/17/2013 09/17/2013
08:48:40 09:57:09
< System operator >
09/17/2013 09/17/2013
08:48:41 09:57:09
< System operator >
09/17/2013 09/17/2013
08:54:55 09:57:09
< System operator >
09/17/2013 09/17/2013
08:56:04 09:57:09
< System operator >
09/17/2013 09/17/2013
08:56:53 09:57:09
< System operator >
09/17/2013 09/17/2013
08:58:12 09:57:09
< System operator >
09/17/2013 09/17/2013
08:58:16 09:57:09
< System operator >
09/17/2013 09/17/2013
08:58:20 09:57:09
< System operator >
09/17/2013 09/17/2013
08:58:38 09:57:09
< System operator >
09/17/2013 09/17/2013
08:59:07 09:57:09
< System operator >
09/17/2013 09/17/2013
09:06:47 09:57:09
< System operator >
09/17/2013 09/17/2013
09:06:50 11:12:32
< System operator >
09/17/2013 09/17/2013
09:07:26 09:57:09
< System operator >
09/17/2013 09/17/2013
09:07:31 09:57:09
< System operator >
09/17/2013 09/17/2013
09:07:44 09:57:09
< System operator >
09/17/2013 09/17/2013
09:07:54 09:57:09
< System operator >
09/17/2013 09/17/2013
09:08:03 09:57:09
< System operator >
09/17/2013 09/17/2013
09:08:09 09:57:09
< System operator >
09/17/2013 09/17/2013
09:08:15 09:57:09
< System operator >
09/17/2013 09/17/2013
09:08:49 09:57:09
< System operator >
09/17/2013 09/17/2013
09:08:54 09:57:09
< System operator >
09/17/2013 09/17/2013
09:09:07 09:57:09
< System operator >
09/17/2013 09/17/2013
09:09:29 09:57:09
< System operator >
09/17/2013 09/17/2013
09:09:50 09:57:09
< System operator >
09/17/2013 09/17/2013
09:10:35 09:57:09
< System operator >
09/17/2013 09/17/2013
09:10:42 09:57:09
< System operator >
09/17/2013 09/17/2013
09:11:05 09:57:09
< System operator >
09/17/2013 09/17/2013
09:11:26 09:57:09
< System operator >
09/17/2013 -09:17:13 09/17/2013 09/17/2013
09:17:14 09:57:09
< System operator >
09/17/2013 09/17/2013
09:20:43 09:57:09
< System operator >
09/17/2013 09/17/2013
09:21:06 09:57:09
< System operator >
09/17/2013 09/17/2013
09:21:25 09:57:09
< System operator >
09/17/2013 09/17/2013
09:21:47 09:57:09
< System operator >
09/17/2013 09/17/2013
09:25:06 09:57:09
< System operator >
09/17/2013 09/17/2013
09:25:27 09:57:09
< System operator >
09/17/2013 09/17/2013
09:29:23 09:57:09
< System operator >
09/17/2013 09/17/2013
09:30:58 14:03:12
< System operator >
09/17/2013 09/17/2013
09:35:45 09:57:09
< System operator >

Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:36:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:37:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:37:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:37:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:37:13
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
09:37:27
No.=0, PassNo=255, S
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:14:05
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
09:38:48
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:39:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:37:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:41:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:40:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:36:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:42:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:42:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:42:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:42:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:43:08
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
09:43:24
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
09:43:41
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:43:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:44:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:43:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:40:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:42:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:38:57
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:43:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:45:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:46:01
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
09:49:05
No.=0, PassNo=255, S
EAC Communication
2384
Alarm
BBBL3/D647_Bencah[HUB]
GBTS
Site No.=40,D647_Bencah[HUB]
Board Type=EAC,
09/17/2013
Board
09:48:06
No.=0, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:50:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:51:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:49:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:51:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:18:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:37:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:37:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:53:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:18:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:53:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
09:53:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:53:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:54:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
09:53:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:58:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:51:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:05:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:05:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:06:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:07:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:10:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:10:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:13:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:17:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:17:17
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
09:36:35 09:57:09
< System operator >
09/17/2013 09/17/2013
09:37:13 09:57:09
< System operator >
09/17/2013 09/17/2013
09:37:13 09:57:09
< System operator >
09/17/2013 09/17/2013
09:37:13 09:57:09
< System operator >
09/17/2013 09/17/2013
09:37:14 09:57:09
< System operator >
09/17/2013 09/17/2013
09:37:29 09:57:09
< System operator >
09/17/2013 09/17/2013
09:38:28 09:57:09
< System operator >
09/17/2013 09/17/2013
09:38:50 09:57:09
< System operator >
09/17/2013 09/17/2013
09:39:44 09:57:09
< System operator >
09/17/2013 09/17/2013
09:40:52 09:57:09
< System operator >
09/17/2013 09/17/2013
09:41:36 09:57:09
< System operator >
09/17/2013 09/17/2013
09:41:45 09:57:09
< System operator >
09/17/2013 09/17/2013
09:42:05 09:57:09
< System operator >
09/17/2013 09/17/2013
09:42:14 09:57:09
< System operator >
09/17/2013 09/17/2013
09:42:14 09:57:09
< System operator >
09/17/2013 09/17/2013
09:42:14 09:57:09
< System operator >
09/17/2013 09/17/2013
09:42:58 09:57:09
< System operator >
09/17/2013 09/17/2013
09:43:18 09:57:09
< System operator >
09/17/2013 09/17/2013
09:43:26 11:12:32
< System operator >
09/17/2013 09/17/2013
09:43:46 09:57:09
< System operator >
09/17/2013 09/17/2013
09:44:12 09:57:09
< System operator >
09/17/2013 09/17/2013
09:44:16 11:12:32
< System operator >
09/17/2013 09/17/2013
09:44:48 09:57:09
< System operator >
09/17/2013 09/17/2013
09:44:54 09:57:09
< System operator >
09/17/2013 09/17/2013
09:44:56 09:57:09
< System operator >
09/17/2013 09/17/2013
09:45:03 09:57:09
< System operator >
09/17/2013 09/17/2013
09:45:23 09:57:09
< System operator >
09/17/2013 09/17/2013
09:45:58 11:12:32
< System operator >
09/17/2013 09/17/2013
09:46:43 11:12:32
< System operator >
09/17/2013 09/17/2013
09:49:07 11:12:32
< System operator >
09/17/2013 09/17/2013
09:49:59 09:57:09
< System operator >
09/17/2013 09/17/2013
09:50:56 11:12:32
< System operator >
09/17/2013 09/17/2013
09:51:32 11:12:32
< System operator >
09/17/2013 09/17/2013
09:51:40 11:12:32
< System operator >
09/17/2013 09/17/2013
09:52:18 09:57:09
< System operator >
09/17/2013 09/17/2013
09:52:28 09:57:09
< System operator >
09/17/2013 09/17/2013
09:52:50 11:12:32
< System operator >
09/17/2013 09/17/2013
09:52:52 11:12:32
< System operator >
09/17/2013 09/17/2013
09:53:46 11:12:32
< System operator >
09/17/2013 09/17/2013
09:54:07 11:12:32
< System operator >
09/17/2013 09/17/2013
09:54:29 11:12:32
< System operator >
09/17/2013 09/17/2013
09:57:11 11:12:32
< System operator >
09/17/2013 09/17/2013
09:57:58 11:12:32
< System operator >
09/17/2013 09/17/2013
09:58:06 11:12:32
< System operator >
09/17/2013 09/17/2013
09:58:20 12:21:24
< System operator >
09/17/2013 09/17/2013
09:58:40 11:12:32
< System operator >
09/17/2013 09/17/2013
10:05:41 11:12:32
< System operator >
09/17/2013 09/17/2013
10:06:07 11:12:32
< System operator >
09/17/2013 09/17/2013
10:07:33 11:12:32
< System operator >
09/17/2013 09/17/2013
10:07:42 11:12:32
< System operator >
09/17/2013 09/17/2013
10:09:30 11:12:32
< System operator >
09/17/2013 09/17/2013
10:10:51 11:12:32
< System operator >
09/17/2013 09/17/2013
10:11:19 12:21:24
< System operator >
09/17/2013 09/17/2013
10:14:09 11:12:32
< System operator >
09/17/2013 09/17/2013
10:17:17 11:12:32
< System operator >
09/17/2013 09/17/2013
10:18:06 11:12:32
< System operator >

Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Correlative Critical
Alarm
Major

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:20:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:21:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:23:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:24:52
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
10:26:43
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
10:24:38
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:20:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:17:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:24:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:29:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:29:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:30:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:49:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:48:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:32:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
10:30:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:29:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:30:34
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
10:35:20
No.=0, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:37:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:38:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
10:38:38
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
10:38:13
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:38:16
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
10:43:14
No.=0, PassNo=255, Su
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:59:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:58:29
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
10:45:11
No.=0, PassNo=255, Su
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
08:13:48
No.=3, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
10:49:45
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:51:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:51:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:52:15
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
10:53:07
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:52:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:53:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:54:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:55:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
10:56:15
No.=0, PassNo=255,
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
10:52:58
No.=3, PassNo=255, Su
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:00:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:01:14
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:01:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:01:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:01:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:01:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:02:14
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:02:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:03:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:03:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:04:05
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:03:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
10:55:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
10:55:37
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/D671_AirBara
GBTS
Site Index=15,
D671_AirBara
BSC Subrack
09/17/2013
No.=0,
10:57:30
BSC Slot No.=20, E1 No.=
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
10:53:59
No.=0, PassNo=255, Su

09/17/2013 09/17/2013
10:20:52 11:12:32
< System operator >
09/17/2013 09/17/2013
10:22:04 12:21:24
< System operator >
09/17/2013 09/17/2013
10:23:13 12:21:24
< System operator >
09/17/2013 09/17/2013
10:25:54 11:12:32
< System operator >
09/17/2013 09/17/2013
10:26:44 11:12:32
< System operator >
09/17/2013 09/17/2013
10:26:45 12:21:24
< System operator >
09/17/2013 09/17/2013
10:26:56 12:21:24
< System operator >
09/17/2013 09/17/2013
10:26:57 11:12:32
< System operator >
09/17/2013 09/17/2013
10:27:24 12:21:24
< System operator >
09/17/2013 09/17/2013
10:29:21 11:12:32
< System operator >
09/17/2013 09/17/2013
10:29:21 11:12:32
< System operator >
09/17/2013 09/17/2013
10:31:08 11:12:32
< System operator >
09/17/2013 09/17/2013
10:36:10 11:12:32
< System operator >
09/17/2013 09/17/2013
10:36:10 11:12:32
< System operator >
09/17/2013 09/17/2013
10:37:23 14:03:12
< System operator >
09/17/2013 09/17/2013
10:37:25 18:06:47
< System operator >
09/17/2013 09/17/2013
10:37:44 11:12:32
< System operator >
09/17/2013 09/17/2013
10:38:02 14:03:12
< System operator >
09/17/2013 09/17/2013
10:38:06 11:12:32
< System operator >
09/17/2013 09/17/2013
10:38:20 12:21:24
< System operator >
09/17/2013 09/17/2013
10:38:25 13:17:14
< System operator >
09/17/2013 09/17/2013
10:39:07 11:12:32
< System operator >
09/17/2013 09/17/2013
10:39:36 11:12:32
< System operator >
09/17/2013 09/17/2013
10:39:45 12:21:24
< System operator >
09/17/2013 09/17/2013
10:44:37 11:12:32
< System operator >
09/17/2013 09/17/2013
10:45:10 11:12:32
< System operator >
09/17/2013 09/17/2013
10:45:32 11:12:32
< System operator >
09/17/2013 09/17/2013
10:47:07 11:12:32
< System operator >
09/17/2013 09/17/2013
10:48:20 11:12:32
< System operator >
09/17/2013 09/17/2013
10:50:35 18:06:47
< System operator >
09/17/2013 09/17/2013
10:51:17 11:12:32
< System operator >
09/17/2013 09/17/2013
10:51:52 11:12:32
< System operator >
09/17/2013 09/17/2013
10:52:21 11:12:32
< System operator >
09/17/2013 09/17/2013
10:53:09 12:21:24
< System operator >
09/17/2013 09/17/2013
10:53:15 11:12:32
< System operator >
09/17/2013 09/17/2013
10:54:49 11:12:32
< System operator >
09/17/2013 09/17/2013
10:55:01 11:12:32
< System operator >
09/17/2013 09/17/2013
10:55:21 11:12:32
< System operator >
09/17/2013 09/17/2013
10:56:17 11:12:32
< System operator >
09/17/2013 09/17/2013
10:57:52 12:21:24
< System operator >
09/17/2013 09/17/2013
11:00:41 11:12:32
< System operator >
09/17/2013 09/17/2013
11:01:20 11:12:32
< System operator >
09/17/2013 09/17/2013
11:01:28 11:12:32
< System operator >
09/17/2013 09/17/2013
11:01:51 11:12:32
< System operator >
09/17/2013 09/17/2013
11:01:54 11:12:32
< System operator >
09/17/2013 09/17/2013
11:02:01 11:12:32
< System operator >
09/17/2013 09/17/2013
11:02:16 11:12:32
< System operator >
09/17/2013 09/17/2013
11:02:48 11:12:32
< System operator >
09/17/2013 09/17/2013
11:03:12 11:12:32
< System operator >
09/17/2013 09/17/2013
11:03:52 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:06 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:10 14:03:12
< System operator >
09/17/2013 09/17/2013
11:04:12 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:13 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:15 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:15 11:12:32
< System operator >

Major
Major
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Minor
Minor
Major
Minor
Minor
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:04:10
No.=0, PassNo=255,
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:04:40
No.=0, PassNo=255, Su
GSM Cell out
21801
of Service
BBBL3/D671_AirBara
GBTS
Site Index=15,
LABEL=4671_AirBara-8,
Cell Index=46,
09/17/2013
Alarm
10:57:20
Cause=Other
CellIndex=46, causes,
CGI=51011
Site
GSM Cell out
21801
of Service
BBBL3/D671_AirBara
GBTS
Site Index=15,
LABEL=4671_AirBara-9,
Cell Index=47,
09/17/2013
Alarm
10:57:20
Cause=Other
CellIndex=47, causes,
CGI=51011
Site
GSM Cell out
21801
of Service
BBBL3/D671_AirBara
GBTS
Site Index=15,
LABEL=4671_AirBara-7,
Cell Index=45,
09/17/2013
Alarm
10:57:20
Cause=Other
CellIndex=45, causes,
CGI=51011
Site
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:07:42
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:09:21
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:08:08
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:07:57
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:07:57
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:07:27
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:07:57
No.=0, PassNo=255, Su
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:09:25
No.=0, PassNo=255,
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:04:47
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:12:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:12:35
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:10:09
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:10:08
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:10:05
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:10:05
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:10:05
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:13:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:14:06
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:11:45
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:15:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:13:43
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:14:31
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:14:25
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:14:22
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:14:22
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:14:22
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:17:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:18:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:19:25
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:17:53
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:17:50
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:17:46
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:17:46
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:17:46
No.=0, PassNo=255, Su
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
11:20:23
No.=0, PassNo=255, S
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:22:05
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:19:12
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset run 2418
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:18:35
No.=0, PassNo=255, Su
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:23:18
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:22:06
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:21:54
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:21:54
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:21:54
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:21:52
No.=0, PassNo=255, Su
Genset run 2418
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:23:58
No.=0, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
11:19:29
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:25:42
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:25:42
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:25:42
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:25:47
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:25:44
No.=0, PassNo=255, Su

09/17/2013 09/17/2013
11:04:24 11:12:32
< System operator >
09/17/2013 09/17/2013
11:04:47 11:12:32
< System operator >
09/17/2013 09/17/2013
11:06:50 11:12:32
< System operator >
09/17/2013 09/17/2013
11:06:55 11:12:32
< System operator >
09/17/2013 09/17/2013
11:06:55 11:12:32
< System operator >
09/17/2013 09/17/2013
11:09:16 11:12:32
< System operator >
09/17/2013 09/18/2013
11:09:39 03:10:45
< System operator >
09/17/2013 09/17/2013
11:09:42 11:12:32
< System operator >
09/17/2013 09/17/2013
11:09:42 11:12:32
< System operator >
09/17/2013 09/17/2013
11:09:42 11:12:32
< System operator >
09/17/2013 09/17/2013
11:09:42 11:12:32
< System operator >
09/17/2013 09/17/2013
11:09:43 11:12:32
< System operator >
09/17/2013 09/17/2013
11:10:06 12:21:24
< System operator >
09/17/2013 09/17/2013
11:11:13 11:12:32
< System operator >
09/17/2013 09/17/2013
11:12:56 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:07 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:13:56 12:21:24
< System operator >
09/17/2013 09/17/2013
11:14:45 12:21:24
< System operator >
09/17/2013 09/17/2013
11:16:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:16:51 12:21:24
< System operator >
09/17/2013 09/17/2013
11:16:53 12:21:24
< System operator >
09/17/2013 09/17/2013
11:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:18:04 12:21:24
< System operator >
09/17/2013 09/17/2013
11:18:21 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:26 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:20:25 12:21:24
< System operator >
09/17/2013 09/17/2013
11:22:44 12:21:24
< System operator >
09/17/2013 09/17/2013
11:23:19 12:21:24
< System operator >
09/17/2013 09/17/2013
11:23:45 12:21:24
< System operator >
09/17/2013 09/17/2013
11:24:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:25:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:25:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:25:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:25:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:25:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:26:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:26:17 12:21:24
< System operator >
09/17/2013 09/17/2013
11:27:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:27:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:27:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:27:45 12:21:24
< System operator >
09/17/2013 09/17/2013
11:27:45 12:21:24
< System operator >

Minor
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Minor
Major
Major
Major
Minor
Minor
Major
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Major
Minor
Major
Major
Major

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:23:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:18:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:19:25
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset Failure
2420
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:26:16
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:30:17
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:30:17
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:30:17
No.=0, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:31:48
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:31:48
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:31:48
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:31:48
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/D671_AirBara
voltage GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:30:34
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:30:20
No.=0, PassNo=255, Su
Genset run 2418
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:31:03
No.=0, PassNo=255, Su
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:37:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:37:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:37:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:37:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:39:10
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
11:33:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:31:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:31:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
11:42:42
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
11:42:49
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:32:54
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:43:16
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:43:16
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:43:16
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:44:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:44:22
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset run 2418
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:43:34
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:43:19
No.=0, PassNo=255, Su
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:51:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:46:14
Subsystem
No.=0, E1/T1
No.=0
Port No
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
11:13:37
No.=3, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:46:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
10:51:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:32:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:58:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
09:32:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:59:00
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:51:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
11:51:28
No.=0, PassNo=255,
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:50:21
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:50:19
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:50:19
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:50:19
No.=0, PassNo=255, Su
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
11:46:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:47:49
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:46:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
11:46:31
Subsystem
No.=0, E1/T1
No.=0
Port No
Genset run 2418
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
11:50:37
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:58:47
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:04:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:04:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:06:17
No.=0, PassNo=255,

09/17/2013 09/17/2013
11:28:55 12:21:24
< System operator >
09/17/2013 09/17/2013
11:29:11 12:21:24
< System operator >
09/17/2013 09/17/2013
11:30:11 12:21:24
< System operator >
09/17/2013 09/17/2013
11:31:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:31:46 12:21:24
< System operator >
09/17/2013 09/17/2013
11:31:46 12:21:24
< System operator >
09/17/2013 09/17/2013
11:31:46 12:21:24
< System operator >
09/17/2013 09/17/2013
11:31:49 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:16 12:21:24
< System operator >
09/17/2013 09/17/2013
11:33:46 12:21:24
< System operator >
09/17/2013 09/17/2013
11:37:03 12:21:24
< System operator >
09/17/2013 09/17/2013
11:37:08 12:21:24
< System operator >
09/17/2013 09/17/2013
11:37:18 12:21:24
< System operator >
09/17/2013 09/17/2013
11:37:22 12:21:24
< System operator >
09/17/2013 09/17/2013
11:39:13 12:21:24
< System operator >
09/17/2013 09/17/2013
11:41:37 16:57:41
< System operator >
09/17/2013 09/17/2013
11:42:28 13:17:14
< System operator >
09/17/2013 09/17/2013
11:42:31 13:17:14
< System operator >
09/17/2013 09/17/2013
11:42:43 12:21:24
< System operator >
09/17/2013 09/17/2013
11:42:52 12:21:24
< System operator >
09/17/2013 09/17/2013
11:43:29 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:18 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:18 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:18 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:37 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:46 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:48 12:21:24
< System operator >
09/17/2013 09/17/2013
11:44:48 12:21:24
< System operator >
09/17/2013 09/17/2013
11:46:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:46:15 12:21:24
< System operator >
09/17/2013 09/17/2013
11:46:17 12:21:24
< System operator >
09/17/2013 09/17/2013
11:46:32 12:21:24
< System operator >
09/17/2013 09/17/2013
11:46:35 12:21:24
< System operator >
09/17/2013 09/17/2013
11:48:35 12:21:24
< System operator >
09/17/2013 09/17/2013
11:48:35 12:21:24
< System operator >
09/17/2013 09/17/2013
11:49:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:49:14 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:26 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:32 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:49 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:49 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:49 12:21:24
< System operator >
09/17/2013 09/17/2013
11:51:49 12:21:24
< System operator >
09/17/2013 09/17/2013
11:53:35 14:03:12
< System operator >
09/17/2013 09/17/2013
11:53:38 12:21:24
< System operator >
09/17/2013 09/17/2013
11:54:54 12:21:24
< System operator >
09/17/2013 09/17/2013
11:55:43 12:21:24
< System operator >
09/17/2013 09/17/2013
11:56:20 12:21:24
< System operator >
09/17/2013 09/17/2013
11:59:20 15:13:42
< System operator >
09/17/2013 09/17/2013
12:04:36 12:21:24
< System operator >
09/17/2013 09/17/2013
12:05:03 12:21:24
< System operator >
09/17/2013 09/17/2013
12:06:19 12:21:24
< System operator >

Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:07:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:07:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:08:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:08:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:08:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:08:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:08:59
No.=0, PassNo=255,
EAC Communication
2384
Alarm
BBBL3/D647_Bencah[HUB]
GBTS
Site No.=40,D647_Bencah[HUB]
Board Type=EAC,
09/17/2013
Board
12:08:35
No.=0, PassNo=255, Su
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
12:09:27
No.=0, PassNo=255, S
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:09:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
12:09:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:09:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:12:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:12:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:13:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:13:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:14:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:14:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:16:51
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:18:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:19:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:19:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:19:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:19:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:20:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:20:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:20:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:21:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:21:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:21:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:21:42
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:18:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
12:16:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
12:26:01
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:29:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:29:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:29:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:29:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:30:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:31:18
No.=0, PassNo=255,
Over Temperature
2376 Alarm
BBBL3/D648_AirGergas[HUB]
GBTS
Site No.=8, D648_AirGergas[HUB]
Board Type=EAC,
09/17/2013
Board
10:10:24
No.=0, PassNo=255, Sub
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
11:58:25
No.=3, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:36:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
12:36:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:44:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
12:44:28
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:46:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:46:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:46:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:46:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:47:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:47:22
No.=0, PassNo=255,
Rectifier module
2406 fault BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
12:45:11
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
12:45:08
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
12:45:08
No.=0, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/D671_AirBara
GBTS
Site No.=15,D671_AirBara
Board Type=EAC,
09/17/2013
Board
12:45:08
No.=0, PassNo=255, Su

09/17/2013 09/17/2013
12:07:21 12:21:24
< System operator >
09/17/2013 09/17/2013
12:08:25 12:21:24
< System operator >
09/17/2013 09/17/2013
12:08:43 12:21:24
< System operator >
09/17/2013 09/17/2013
12:08:49 12:21:24
< System operator >
09/17/2013 09/17/2013
12:08:53 12:21:24
< System operator >
09/17/2013 09/17/2013
12:08:57 12:21:24
< System operator >
09/17/2013 09/17/2013
12:09:03 12:21:24
< System operator >
09/17/2013 09/17/2013
12:09:12 12:21:24
< System operator >
09/17/2013 09/17/2013
12:09:28 13:17:14
< System operator >
09/17/2013 09/17/2013
12:09:56 12:21:24
< System operator >
09/17/2013 09/17/2013
12:11:04 12:21:24
< System operator >
09/17/2013 09/17/2013
12:12:12 12:21:24
< System operator >
09/17/2013 09/17/2013
12:12:35 12:21:24
< System operator >
09/17/2013 09/17/2013
12:12:54 12:21:24
< System operator >
09/17/2013 09/17/2013
12:13:09 12:21:24
< System operator >
09/17/2013 09/17/2013
12:13:48 13:17:14
< System operator >
09/17/2013 09/17/2013
12:14:05 13:17:14
< System operator >
09/17/2013 09/17/2013
12:14:05 12:21:24
< System operator >
09/17/2013 09/17/2013
12:17:14 12:21:24
< System operator >
09/17/2013 09/17/2013
12:18:38 12:21:24
< System operator >
09/17/2013 09/17/2013
12:19:36 12:21:24
< System operator >
09/17/2013 09/17/2013
12:19:40 12:21:24
< System operator >
09/17/2013 09/17/2013
12:19:44 12:21:24
< System operator >
09/17/2013 09/17/2013
12:19:54 12:21:24
< System operator >
09/17/2013 09/17/2013
12:20:26 12:21:24
< System operator >
09/17/2013 09/17/2013
12:20:30 12:21:24
< System operator >
09/17/2013 09/17/2013
12:20:34 13:17:14
< System operator >
09/17/2013 09/17/2013
12:21:26 13:17:14
< System operator >
09/17/2013 09/17/2013
12:21:30 13:17:14
< System operator >
09/17/2013 09/17/2013
12:21:41 13:17:14
< System operator >
09/17/2013 09/17/2013
12:21:44 13:17:14
< System operator >
09/17/2013 09/17/2013
12:22:50 14:03:12
< System operator >
09/17/2013 09/17/2013
12:23:54 13:17:14
< System operator >
09/17/2013 09/17/2013
12:28:52 13:17:14
< System operator >
09/17/2013 09/17/2013
12:29:30 13:17:14
< System operator >
09/17/2013 09/17/2013
12:29:48 13:17:14
< System operator >
09/17/2013 09/17/2013
12:29:56 13:17:14
< System operator >
09/17/2013 09/17/2013
12:30:03 13:17:14
< System operator >
09/17/2013 09/17/2013
12:30:37 13:17:14
< System operator >
09/17/2013 09/17/2013
12:31:21 13:17:14
< System operator >
09/17/2013 09/17/2013
12:33:33 13:17:14
< System operator >
09/17/2013 09/17/2013
12:36:30 16:57:41
< System operator >
09/17/2013 09/17/2013
12:36:51 13:17:14
< System operator >
09/17/2013 09/17/2013
12:40:29 13:17:14
< System operator >
09/17/2013 09/17/2013
12:44:53 13:17:14
< System operator >
09/17/2013 09/17/2013
12:45:12 14:03:12
< System operator >
09/17/2013 09/17/2013
12:46:24 13:17:14
< System operator >
09/17/2013 09/17/2013
12:46:36 13:17:14
< System operator >
09/17/2013 09/17/2013
12:46:42 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:01 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:14 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:26 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:28 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:28 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:28 13:17:14
< System operator >
09/17/2013 09/17/2013
12:47:28 13:17:14
< System operator >

Minor
Major
Minor
Major
Minor
Correlative Minor
Alarm
Minor
Correlative Critical
Alarm
Major
Major
Major
Major
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Minor
Warning
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Major
Minor

E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:48:35
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:49:21
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:54:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss25800
of Signal BBBL3/227B745L1_Trans2Nylending2
GBTS
Cabinet No.=0,
227B745L1_Trans2Nylending2
Subrack
09/17/2013
No.=0, Slot
12:43:35
No.=6, Port No.=0, Site N
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=24,
Slot No.=24,
09/17/2013
Subrack
Subsystem
No=0,
12:43:32
Subsystem
No.=0, E1/T1
No.=0
Port No
External Clock
26262
Reference
BBBL3/227B745L1_Trans2Nylending2
ProblemGBTS
Specific Problem=Clock
227B745L1_Trans2Nylending2
09/17/2013
Reference12:43:41
Lost, Site No.=61, Site Typ
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=22,
Slot No.=22,
09/17/2013
Subrack
Subsystem
No=0,
12:43:31
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/227A807_Trans2nyelending
GBTS
Site Index=28,
227A807_Trans2nyelending
BSC Subrack
09/17/2013
No.=0,
12:45:15
BSC Slot No.=22, E1 No.=
AC L3 Failure
6450
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
09:35:24
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
09:35:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
09:35:24
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
12:48:46
No.=0, PassNo=255,
OML Fault 21807
BBBL3/227B745L1_Trans2Nylending2
GBTS
Site Index=61,
227B745L1_Trans2Nylending2
BSC Subrack
09/17/2013
No.=0,
12:45:25
BSC Slot No.=24, E1 No.=
GSM Cell out
21801
of Service
BBBL3/227B745L1_Trans2Nylending2
GBTS
Site Index=61,
LABEL=PP27456,
Cell Index=197,
09/17/2013
CellIndex=197,
Alarm
12:45:20
Cause=Other
CGI=5101158C6
causes, Si
GSM Cell out
21801
of Service
BBBL3/227B745L1_Trans2Nylending2
GBTS
Site Index=61,
LABEL=PP27455,
Cell Index=196,
09/17/2013
CellIndex=196,
Alarm
12:45:20
Cause=Other
CGI=5101158C6
causes, Si
GSM Cell out
21801
of Service
BBBL3/227B745L1_Trans2Nylending2
GBTS
Site Index=61,
LABEL=PP27454,
Cell Index=195,
09/17/2013
CellIndex=195,
Alarm
12:45:20
Cause=Other
CGI=5101158C6
causes, Si
GSM Cell out
21801
of Service
BBBL3/227A807_Trans2nyelending
GBTS
Site Index=28,
LABEL=1807_Trans2Nyelanding-7,
Cell Index=86,
09/17/2013
Alarm
12:45:15
Cause=Other
CellIndex=86,
causes, Site
GSM Cell out
21801
of Service
BBBL3/227A807_Trans2nyelending
GBTS
Site Index=28,
LABEL=1807_Trans2Nyelanding-9,
Cell Index=94,
09/17/2013
Alarm
12:45:15
Cause=Other
CellIndex=94,
causes, Site
GSM Cell out
21801
of Service
BBBL3/227A807_Trans2nyelending
GBTS
Site Index=28,
LABEL=1807_Trans2Nyelanding-8,
Cell Index=93,
09/17/2013
Alarm
12:45:15
Cause=Other
CellIndex=93,
causes, Site
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
12:57:48
Subsystem
No.=0, E1/T1
No.=0
Port No
Site Reset Alarm
4770
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DTMU,
09/17/2013Board
12:56:49
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
12:59:18
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:59:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:59:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:59:49
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
12:59:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:00:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:00:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:00:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:00:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:03:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:03:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:04:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:04:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:04:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:04:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:04:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:06:15
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:06:02
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
12:56:09
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:05:45
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:11:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:12:57
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:53:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:16:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:16:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:16:23
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:07:33
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:17:37
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:21:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:21:26
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:53:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:55:13
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:23:06
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:54:13
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
12:49:20 13:17:14
< System operator >
09/17/2013 09/17/2013
12:49:24 13:17:14
< System operator >
09/17/2013 09/17/2013
12:50:39 13:17:14
< System operator >
09/17/2013 09/17/2013
12:55:18 13:17:14
< System operator >
09/17/2013 09/17/2013
12:55:19 13:17:14
< System operator >
09/17/2013 09/17/2013
12:55:30 13:17:14
< System operator >
09/17/2013 -12:55:46 09/17/2013 09/17/2013
12:55:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:55:50 15:13:42
< System operator >
09/17/2013 09/17/2013
12:55:50 15:13:42
< System operator >
09/17/2013 09/17/2013
12:55:50 15:13:42
< System operator >
09/17/2013 09/17/2013
12:56:08 13:17:14
< System operator >
09/17/2013 09/17/2013
12:56:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:56:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:56:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:56:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:57:50 13:17:14
< System operator >
09/17/2013 09/17/2013
12:58:00 13:17:14
< System operator >
09/17/2013 09/17/2013
12:58:00 13:17:14
< System operator >
09/17/2013 09/17/2013
12:58:31 14:03:12
< System operator >
09/17/2013 -12:59:07 09/17/2013 09/17/2013
12:59:19 14:03:12
< System operator >
09/17/2013 09/17/2013
12:59:22 13:17:14
< System operator >
09/17/2013 09/17/2013
12:59:42 13:17:14
< System operator >
09/17/2013 09/17/2013
12:59:53 13:17:14
< System operator >
09/17/2013 09/17/2013
13:00:01 13:17:14
< System operator >
09/17/2013 09/17/2013
13:00:11 13:17:14
< System operator >
09/17/2013 09/17/2013
13:00:17 13:17:14
< System operator >
09/17/2013 09/17/2013
13:00:25 13:17:14
< System operator >
09/17/2013 09/17/2013
13:00:31 13:17:14
< System operator >
09/17/2013 09/17/2013
13:03:43 13:17:14
< System operator >
09/17/2013 09/17/2013
13:04:03 13:17:14
< System operator >
09/17/2013 09/17/2013
13:04:20 13:17:14
< System operator >
09/17/2013 09/17/2013
13:04:25 13:17:14
< System operator >
09/17/2013 09/17/2013
13:04:30 13:17:14
< System operator >
09/17/2013 09/17/2013
13:04:41 13:17:14
< System operator >
09/17/2013 09/17/2013
13:05:02 13:17:14
< System operator >
09/17/2013 09/17/2013
13:06:19 13:17:14
< System operator >
09/17/2013 09/17/2013
13:06:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:06:35 13:17:14
< System operator >
09/17/2013 09/17/2013
13:07:00 14:03:12
< System operator >
09/17/2013 09/17/2013
13:11:10 13:17:14
< System operator >
09/17/2013 09/17/2013
13:13:00 14:03:12
< System operator >
09/17/2013 09/17/2013
13:13:40 13:17:14
< System operator >
09/17/2013 09/17/2013
13:14:19 13:17:14
< System operator >
09/17/2013 09/17/2013
13:16:52 14:03:12
< System operator >
09/17/2013 09/17/2013
13:17:03 14:03:12
< System operator >
09/17/2013 09/17/2013
13:17:03 14:03:12
< System operator >
09/17/2013 09/17/2013
13:17:27 14:03:12
< System operator >
09/17/2013 09/17/2013
13:18:23 14:03:12
< System operator >
09/17/2013 09/17/2013
13:21:08 14:03:12
< System operator >
09/17/2013 09/17/2013
13:21:27 14:03:12
< System operator >
09/17/2013 09/17/2013
13:21:41 14:03:12
< System operator >
09/17/2013 09/17/2013
13:22:19 14:03:12
< System operator >
09/17/2013 09/17/2013
13:23:09 14:03:12
< System operator >
09/17/2013 09/17/2013
13:23:19 14:03:12
< System operator >

Minor
Major
Minor
Major
Major
Minor
Minor
Major
Minor
Major
Minor
Minor
Major
Minor
Minor
Major
Major
Major
Major
Major
Minor
Minor
Critical
Major
Major
Minor
Minor
Correlative Critical
Alarm
Correlative Critical
Alarm
Correlative Critical
Alarm
Minor
Warning
Major
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Major
Major
Minor

E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
11:53:35
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
13:01:26
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
13:21:52
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:25:47
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:27:26
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:22:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:21:07
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:27:59
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:21:26
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:28:37
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:28:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:30:52
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:31:32
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:31:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:30:32
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:33:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:34:14
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
13:36:26
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:37:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:37:42
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:38:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
12:05:49
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/227A810_Terap
GBTS
Site Index=42,
227A810_Terap
BSC Subrack
09/17/2013
No.=1,
12:07:32
BSC Slot No.=20, E1 No.=
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
09:40:45
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
13:40:17
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:40:10
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:40:22
Subsystem
No.=0, E1/T1
No.=0
Port No
GSM Cell out
21801
of Service
BBBL3/227A810_Terap
GBTS
Site Index=42,
LABEL=1810_Terap-7,
Cell Index=126,
09/17/2013
Alarm
12:07:32
CellIndex=126,
Cause=OtherCGI=51011
causes, Si
GSM Cell out
21801
of Service
BBBL3/227A810_Terap
GBTS
Site Index=42,
LABEL=1810_Terap-9,
Cell Index=128,
09/17/2013
Alarm
12:07:32
CellIndex=128,
Cause=OtherCGI=51011
causes, Si
GSM Cell out
21801
of Service
BBBL3/227A810_Terap
GBTS
Site Index=42,
LABEL=1810_Terap-8,
Cell Index=127,
09/17/2013
Alarm
12:07:32
CellIndex=127,
Cause=OtherCGI=51011
causes, Si
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:40:36
Subsystem
No.=0, E1/T1
No.=0
Port No
Site Reset Alarm
4770
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DTMU,
09/17/2013Board
13:39:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:41:42
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:41:27
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:42:20
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:41:21
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:43:45
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:37:09
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:15:18
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:27:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:14:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:47:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:48:06
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:39:41
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:27:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:48:35
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
13:48:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:48:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:51:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:51:48
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:48:12
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
13:51:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:51:39
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:54:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:55:09
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:50:42
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
13:23:41 14:03:12
< System operator >
09/17/2013 09/17/2013
13:27:19 14:03:12
< System operator >
09/17/2013 09/17/2013
13:27:23 15:13:42
< System operator >
09/17/2013 09/17/2013
13:27:24 14:03:12
< System operator >
09/17/2013 09/17/2013
13:27:47 14:03:12
< System operator >
09/17/2013 09/17/2013
13:27:47 16:01:41
< System operator >
09/17/2013 09/17/2013
13:27:59 15:13:42
< System operator >
09/17/2013 09/17/2013
13:28:03 14:03:12
< System operator >
09/17/2013 09/17/2013
13:28:21 15:13:42
< System operator >
09/17/2013 09/17/2013
13:28:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:28:44 14:03:12
< System operator >
09/17/2013 09/17/2013
13:30:53 14:03:12
< System operator >
09/17/2013 09/17/2013
13:31:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:32:04 15:13:42
< System operator >
09/17/2013 09/17/2013
13:32:13 18:06:47
< System operator >
09/17/2013 09/17/2013
13:33:45 14:03:12
< System operator >
09/17/2013 09/17/2013
13:34:15 14:03:12
< System operator >
09/17/2013 09/17/2013
13:36:28 14:03:12
< System operator >
09/17/2013 09/17/2013
13:37:39 14:03:12
< System operator >
09/17/2013 09/17/2013
13:37:48 14:03:12
< System operator >
09/17/2013 09/17/2013
13:38:27 14:03:12
< System operator >
09/17/2013 09/17/2013
13:38:28 14:03:12
< System operator >
09/17/2013 09/18/2013
13:38:39 03:10:45
< System operator >
09/17/2013 09/17/2013
13:38:39 15:13:42
< System operator >
09/17/2013 09/17/2013
13:40:19 15:13:42
< System operator >
09/17/2013 09/17/2013
13:40:40 14:03:12
< System operator >
09/17/2013 09/17/2013
13:40:40 14:03:12
< System operator >
09/17/2013 09/18/2013
13:40:47 00:59:18
< System operator >
09/17/2013 09/18/2013
13:40:52 00:59:18
< System operator >
09/17/2013 09/18/2013
13:40:52 00:59:18
< System operator >
09/17/2013 09/17/2013
13:41:17 18:06:47
< System operator >
09/17/2013 09/17/2013
13:41:41 14:03:12
< System operator >
09/17/2013 09/17/2013
13:41:44 14:03:12
< System operator >
09/17/2013 -13:41:51 09/17/2013 09/17/2013
13:42:23 14:03:12
< System operator >
09/17/2013 09/17/2013
13:42:31 15:13:42
< System operator >
09/17/2013 09/17/2013
13:43:53 14:03:12
< System operator >
09/17/2013 09/17/2013
13:46:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:47:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:47:42 14:03:12
< System operator >
09/17/2013 09/17/2013
13:47:42 14:03:12
< System operator >
09/17/2013 09/17/2013
13:47:48 15:13:42
< System operator >
09/17/2013 09/17/2013
13:48:07 14:03:12
< System operator >
09/17/2013 09/17/2013
13:48:10 14:03:12
< System operator >
09/17/2013 09/17/2013
13:48:21 14:03:12
< System operator >
09/17/2013 09/18/2013
13:49:19 01:33:13
< System operator >
09/17/2013 09/17/2013
13:49:20 14:03:12
< System operator >
09/17/2013 09/17/2013
13:50:07 15:13:42
< System operator >
09/17/2013 09/17/2013
13:51:40 14:03:12
< System operator >
09/17/2013 09/17/2013
13:52:51 16:57:41
< System operator >
09/17/2013 09/17/2013
13:54:12 14:03:12
< System operator >
09/17/2013 09/17/2013
13:54:33 16:01:41
< System operator >
09/17/2013 09/17/2013
13:54:35 15:13:42
< System operator >
09/17/2013 09/17/2013
13:55:07 14:03:12
< System operator >
09/17/2013 09/17/2013
13:55:19 14:03:12
< System operator >
09/17/2013 09/17/2013
13:55:43 14:03:12
< System operator >

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Minor
Minor
Major
Major
Critical
Major
Major
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major

E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:50:42
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
13:28:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:48:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:50:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:50:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:28:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
07:47:59
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:54:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:56:38
No.=0, PassNo=255,
Genset Failure
6456Alarm BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
13:44:12
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
13:47:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:47:21
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:58:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
13:58:54
No.=0, PassNo=255,
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 13:57:12
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:56:32
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:03:08
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:05:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:08:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:06:01
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:08:49
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:06:02
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:13:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
09:45:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:10:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
14:12:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:10:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:10:44
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:13:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:13:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:13:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:14:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:14:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:14:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:15:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:15:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:15:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:15:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:16:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:16:10
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:11:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:17:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:18:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:18:56
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:18:28
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:20:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:21:58
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:22:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:23:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:23:15
No.=0, PassNo=255,
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
13:27:19
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:23:27
No.=0, PassNo=255,
AC L3 Failure
6450
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:23:18
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:23:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:23:18
No.=0, PassNo=255,

09/17/2013 09/17/2013
13:55:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:55:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:55:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:28 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:39 14:03:12
< System operator >
09/17/2013 09/17/2013
13:56:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:58:21 14:03:12
< System operator >
09/17/2013 09/17/2013
13:58:43 14:03:12
< System operator >
09/17/2013 09/17/2013
13:58:51 14:03:12
< System operator >
09/17/2013 09/17/2013
13:59:15 15:13:42
< System operator >
09/17/2013 09/17/2013
14:00:45 22:29:26
< System operator >
09/17/2013 09/17/2013
14:02:55 14:03:12
< System operator >
09/17/2013 09/17/2013
14:03:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:05:34 15:13:42
< System operator >
09/17/2013 09/17/2013
14:08:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:08:37 15:13:42
< System operator >
09/17/2013 09/17/2013
14:08:52 15:13:42
< System operator >
09/17/2013 09/17/2013
14:09:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:10:22 15:13:42
< System operator >
09/17/2013 09/17/2013
14:10:43 15:13:42
< System operator >
09/17/2013 09/17/2013
14:10:45 15:13:42
< System operator >
09/17/2013 09/17/2013
14:12:43 16:01:41
< System operator >
09/17/2013 09/17/2013
14:12:57 15:13:42
< System operator >
09/17/2013 09/17/2013
14:12:58 16:01:41
< System operator >
09/17/2013 09/17/2013
14:13:08 15:13:42
< System operator >
09/17/2013 09/17/2013
14:13:13 15:13:42
< System operator >
09/17/2013 09/17/2013
14:14:00 15:13:42
< System operator >
09/17/2013 09/17/2013
14:14:04 15:13:42
< System operator >
09/17/2013 09/17/2013
14:14:11 15:13:42
< System operator >
09/17/2013 09/17/2013
14:14:48 15:13:42
< System operator >
09/17/2013 09/17/2013
14:15:11 15:13:42
< System operator >
09/17/2013 09/17/2013
14:15:24 15:13:42
< System operator >
09/17/2013 09/17/2013
14:15:36 15:13:42
< System operator >
09/17/2013 09/17/2013
14:15:52 15:13:42
< System operator >
09/17/2013 09/17/2013
14:16:02 15:13:42
< System operator >
09/17/2013 09/17/2013
14:16:12 15:13:42
< System operator >
09/17/2013 09/17/2013
14:17:22 15:13:42
< System operator >
09/17/2013 09/17/2013
14:17:55 15:13:42
< System operator >
09/17/2013 09/17/2013
14:18:22 15:13:42
< System operator >
09/17/2013 09/17/2013
14:18:58 15:13:42
< System operator >
09/17/2013 09/17/2013
14:19:08 18:06:47
< System operator >
09/17/2013 09/17/2013
14:20:30 15:13:42
< System operator >
09/17/2013 09/17/2013
14:22:04 15:13:42
< System operator >
09/17/2013 09/17/2013
14:22:34 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:11 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:17 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:24 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:25 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:33 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:43 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:43 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:43 15:13:42
< System operator >

Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:23:45
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:24:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:24:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:24:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:24:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:25:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:25:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:26:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:26:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:27:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:27:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:27:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:28:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:28:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:29:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:29:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:29:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:30:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:30:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:30:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:30:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:31:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:31:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:32:21
No.=0, PassNo=255,
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:24:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:32:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:32:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:32:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:33:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:33:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:34:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:34:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:35:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:35:18
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
14:35:37
No.=0, PassNo=255, S
AC L3 Failure
6450
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:32:18
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:32:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:32:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:35:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:36:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:36:54
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:26:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:38:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:39:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:39:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:39:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:39:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:40:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:41:05
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:39:18
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:41:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:41:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:41:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:42:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:42:18
No.=0, PassNo=255,

09/17/2013 09/17/2013
14:23:50 15:13:42
< System operator >
09/17/2013 09/17/2013
14:23:50 15:13:42
< System operator >
09/17/2013 09/17/2013
14:24:07 15:13:42
< System operator >
09/17/2013 09/17/2013
14:24:18 15:13:42
< System operator >
09/17/2013 09/17/2013
14:24:22 15:13:42
< System operator >
09/17/2013 09/17/2013
14:24:39 15:13:42
< System operator >
09/17/2013 09/17/2013
14:25:02 15:13:42
< System operator >
09/17/2013 09/17/2013
14:25:29 15:13:42
< System operator >
09/17/2013 09/17/2013
14:26:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:26:59 15:13:42
< System operator >
09/17/2013 09/17/2013
14:27:25 15:13:42
< System operator >
09/17/2013 09/17/2013
14:27:29 15:13:42
< System operator >
09/17/2013 09/17/2013
14:27:41 15:13:42
< System operator >
09/17/2013 09/17/2013
14:28:18 15:13:42
< System operator >
09/17/2013 09/17/2013
14:28:57 15:13:42
< System operator >
09/17/2013 09/17/2013
14:29:13 15:13:42
< System operator >
09/17/2013 09/17/2013
14:29:24 15:13:42
< System operator >
09/17/2013 09/17/2013
14:29:28 15:13:42
< System operator >
09/17/2013 09/17/2013
14:30:27 15:13:42
< System operator >
09/17/2013 09/17/2013
14:30:34 15:13:42
< System operator >
09/17/2013 09/17/2013
14:30:34 15:13:42
< System operator >
09/17/2013 09/17/2013
14:30:37 15:13:42
< System operator >
09/17/2013 09/17/2013
14:31:07 15:13:42
< System operator >
09/17/2013 09/17/2013
14:31:19 15:13:42
< System operator >
09/17/2013 09/17/2013
14:32:23 15:13:42
< System operator >
09/17/2013 09/17/2013
14:32:26 15:13:42
< System operator >
09/17/2013 09/17/2013
14:32:30 15:13:42
< System operator >
09/17/2013 09/17/2013
14:32:34 15:13:42
< System operator >
09/17/2013 09/17/2013
14:32:39 15:13:42
< System operator >
09/17/2013 09/17/2013
14:33:05 15:13:42
< System operator >
09/17/2013 09/17/2013
14:33:56 15:13:42
< System operator >
09/17/2013 09/17/2013
14:34:03 15:13:42
< System operator >
09/17/2013 09/17/2013
14:34:58 15:13:42
< System operator >
09/17/2013 09/17/2013
14:35:06 15:13:42
< System operator >
09/17/2013 09/17/2013
14:35:20 15:13:42
< System operator >
09/17/2013 09/17/2013
14:35:41 15:13:42
< System operator >
09/17/2013 09/17/2013
14:35:48 16:01:41
< System operator >
09/17/2013 09/17/2013
14:35:48 16:01:41
< System operator >
09/17/2013 09/17/2013
14:35:48 16:01:41
< System operator >
09/17/2013 09/17/2013
14:36:00 15:13:42
< System operator >
09/17/2013 09/17/2013
14:36:50 15:13:42
< System operator >
09/17/2013 09/17/2013
14:36:55 15:13:42
< System operator >
09/17/2013 09/17/2013
14:38:04 15:13:42
< System operator >
09/17/2013 09/17/2013
14:38:44 15:13:42
< System operator >
09/17/2013 09/17/2013
14:39:16 15:13:42
< System operator >
09/17/2013 09/17/2013
14:39:25 15:13:42
< System operator >
09/17/2013 09/17/2013
14:39:38 15:13:42
< System operator >
09/17/2013 09/17/2013
14:39:48 15:13:42
< System operator >
09/17/2013 09/17/2013
14:40:52 15:13:42
< System operator >
09/17/2013 09/17/2013
14:41:08 15:13:42
< System operator >
09/17/2013 09/17/2013
14:41:18 15:13:42
< System operator >
09/17/2013 09/17/2013
14:41:23 15:13:42
< System operator >
09/17/2013 09/17/2013
14:41:56 15:13:42
< System operator >
09/17/2013 09/17/2013
14:42:01 15:13:42
< System operator >
09/17/2013 09/17/2013
14:42:04 15:13:42
< System operator >
09/17/2013 09/17/2013
14:42:20 15:13:42
< System operator >

Major
Major
Minor
Major
Minor
Major
Minor
Minor
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:43:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:43:43
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:01:43
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:43:52
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:43:47
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:44:05
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
14:43:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:44:05
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:45:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:45:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:48:06
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:01:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:44:45
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:51:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:52:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:52:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:53:03
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:53:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:53:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:53:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:54:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:55:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:55:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:55:49
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:11
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:48
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
14:55:52
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:56:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
14:57:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:58:13
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
14:58:35
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:58:42
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
14:41:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:59:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:59:46
No.=0, PassNo=255,
Over Temperature
6412 Alarm
BBBL3/227A811_PasirPutih
GBTS
Site No.=44,227A811_PasirPutih
Board Type=DEMU,
09/17/2013Board
10:44:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
14:59:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:00:04
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:56:24
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:01:23
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:55:46
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:01:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:02:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:02:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:02:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:03:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:04:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:04:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:04:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:06:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:06:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:06:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:06:48
No.=0, PassNo=255,

09/17/2013 09/17/2013
14:43:26 15:13:42
< System operator >
09/17/2013 09/17/2013
14:43:44 15:13:42
< System operator >
09/17/2013 09/17/2013
14:43:45 15:13:42
< System operator >
09/17/2013 09/17/2013
14:43:54 15:13:42
< System operator >
09/17/2013 09/18/2013
14:44:02 01:33:13
< System operator >
09/17/2013 09/17/2013
14:44:06 15:13:42
< System operator >
09/17/2013 09/18/2013
14:44:07 01:33:13
< System operator >
09/17/2013 09/17/2013
14:44:41 15:13:42
< System operator >
09/17/2013 09/17/2013
14:45:14 15:13:42
< System operator >
09/17/2013 09/17/2013
14:45:53 15:13:42
< System operator >
09/17/2013 09/17/2013
14:48:07 15:13:42
< System operator >
09/17/2013 09/17/2013
14:48:24 15:13:42
< System operator >
09/17/2013 09/17/2013
14:48:46 15:13:42
< System operator >
09/17/2013 09/17/2013
14:51:43 15:13:42
< System operator >
09/17/2013 09/17/2013
14:52:21 15:13:42
< System operator >
09/17/2013 09/17/2013
14:52:57 15:13:42
< System operator >
09/17/2013 09/17/2013
14:53:05 15:13:42
< System operator >
09/17/2013 09/17/2013
14:53:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:53:21 15:13:42
< System operator >
09/17/2013 09/17/2013
14:53:59 15:13:42
< System operator >
09/17/2013 09/17/2013
14:54:33 15:13:42
< System operator >
09/17/2013 09/17/2013
14:55:21 15:13:42
< System operator >
09/17/2013 09/17/2013
14:55:29 15:13:42
< System operator >
09/17/2013 09/17/2013
14:55:51 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:09 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:14 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:19 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:33 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:50 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:50 15:13:42
< System operator >
09/17/2013 09/17/2013
14:56:56 15:13:42
< System operator >
09/17/2013 09/17/2013
14:57:46 16:01:41
< System operator >
09/17/2013 09/17/2013
14:58:15 15:13:42
< System operator >
09/17/2013 09/17/2013
14:58:37 16:01:41
< System operator >
09/17/2013 09/17/2013
14:58:45 15:13:42
< System operator >
09/17/2013 09/17/2013
14:59:00 16:01:41
< System operator >
09/17/2013 09/17/2013
14:59:40 15:13:42
< System operator >
09/17/2013 09/17/2013
14:59:48 15:13:42
< System operator >
09/17/2013 -14:59:51 09/17/2013 09/17/2013
14:59:52 15:13:42
< System operator >
09/17/2013 09/17/2013
15:00:06 15:13:42
< System operator >
09/17/2013 09/17/2013
15:01:25 15:13:42
< System operator >
09/17/2013 09/17/2013
15:01:29 15:13:42
< System operator >
09/17/2013 09/17/2013
15:01:46 15:13:42
< System operator >
09/17/2013 09/17/2013
15:01:59 15:13:42
< System operator >
09/17/2013 09/17/2013
15:02:32 15:13:42
< System operator >
09/17/2013 09/17/2013
15:02:40 15:13:42
< System operator >
09/17/2013 09/17/2013
15:02:54 15:13:42
< System operator >
09/17/2013 09/17/2013
15:03:09 15:13:42
< System operator >
09/17/2013 09/17/2013
15:04:04 15:13:42
< System operator >
09/17/2013 09/17/2013
15:04:12 15:13:42
< System operator >
09/17/2013 09/17/2013
15:04:18 15:13:42
< System operator >
09/17/2013 09/17/2013
15:06:04 15:13:42
< System operator >
09/17/2013 09/17/2013
15:06:42 15:13:42
< System operator >
09/17/2013 09/17/2013
15:06:46 15:13:42
< System operator >
09/17/2013 09/17/2013
15:06:52 15:13:42
< System operator >

Major
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Minor
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:07:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:07:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:07:52
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:07:59
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:08:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:08:33
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:11:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:11:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:12:11
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:12:33
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:11:09
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:12:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:12:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:13:07
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:07:47
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:14:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:14:15
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:07:24
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:14:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:14:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:16:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:16:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:16:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:18:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:18:35
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:19:41
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:19:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:19:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:20:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:20:55
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:20:41
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:19:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:23:55
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:24:40
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:24:43
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:24:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:24:49
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:24:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:25:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:25:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:25:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:25:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:25:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:26:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:26:14
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:26:54
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:26:54
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:27:17
No.=0, PassNo=255, S
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
15:26:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:27:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:26:50
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:27:40
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:28:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:28:36
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:28:57
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:29:01
No.=0, PassNo=255,

09/17/2013 09/17/2013
15:07:44 15:13:42
< System operator >
09/17/2013 09/17/2013
15:07:51 15:13:42
< System operator >
09/17/2013 09/17/2013
15:07:56 15:13:42
< System operator >
09/17/2013 09/17/2013
15:08:49 16:01:41
< System operator >
09/17/2013 09/17/2013
15:08:49 18:06:47
< System operator >
09/17/2013 09/17/2013
15:08:50 16:01:41
< System operator >
09/17/2013 09/17/2013
15:11:37 15:13:42
< System operator >
09/17/2013 09/17/2013
15:11:43 15:13:42
< System operator >
09/17/2013 09/17/2013
15:12:14 15:13:42
< System operator >
09/17/2013 09/17/2013
15:12:34 15:13:42
< System operator >
09/17/2013 09/17/2013
15:12:37 16:01:41
< System operator >
09/17/2013 09/17/2013
15:12:39 15:13:42
< System operator >
09/17/2013 09/17/2013
15:12:55 15:13:42
< System operator >
09/17/2013 09/17/2013
15:13:09 16:01:41
< System operator >
09/17/2013 09/17/2013
15:13:47 16:01:41
< System operator >
09/17/2013 09/17/2013
15:14:08 16:01:41
< System operator >
09/17/2013 09/17/2013
15:14:17 16:01:41
< System operator >
09/17/2013 09/17/2013
15:14:26 16:01:41
< System operator >
09/17/2013 09/17/2013
15:14:33 16:01:41
< System operator >
09/17/2013 09/17/2013
15:15:01 16:01:41
< System operator >
09/17/2013 09/17/2013
15:16:35 16:01:41
< System operator >
09/17/2013 09/17/2013
15:16:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:16:49 16:01:41
< System operator >
09/17/2013 09/17/2013
15:18:19 16:01:41
< System operator >
09/17/2013 09/17/2013
15:18:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:19:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:19:45 16:01:41
< System operator >
09/17/2013 09/17/2013
15:19:58 16:01:41
< System operator >
09/17/2013 09/17/2013
15:20:24 16:01:41
< System operator >
09/17/2013 09/17/2013
15:20:58 16:01:41
< System operator >
09/17/2013 09/17/2013
15:21:06 16:01:41
< System operator >
09/17/2013 09/17/2013
15:21:15 16:01:41
< System operator >
09/17/2013 09/17/2013
15:23:58 16:01:41
< System operator >
09/17/2013 09/17/2013
15:24:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:24:45 16:01:41
< System operator >
09/17/2013 09/17/2013
15:24:48 16:01:41
< System operator >
09/17/2013 09/17/2013
15:24:52 16:01:41
< System operator >
09/17/2013 09/17/2013
15:24:56 16:01:41
< System operator >
09/17/2013 09/17/2013
15:25:12 16:01:41
< System operator >
09/17/2013 09/17/2013
15:25:20 16:01:41
< System operator >
09/17/2013 09/17/2013
15:25:26 16:01:41
< System operator >
09/17/2013 09/17/2013
15:25:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:25:52 16:01:41
< System operator >
09/17/2013 09/17/2013
15:26:04 16:01:41
< System operator >
09/17/2013 09/17/2013
15:26:16 16:01:41
< System operator >
09/17/2013 09/17/2013
15:26:55 16:01:41
< System operator >
09/17/2013 09/17/2013
15:26:56 16:01:41
< System operator >
09/17/2013 09/17/2013
15:27:19 16:01:41
< System operator >
09/17/2013 09/17/2013
15:27:24 16:01:41
< System operator >
09/17/2013 09/17/2013
15:27:25 18:06:47
< System operator >
09/17/2013 09/17/2013
15:27:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:27:41 16:01:41
< System operator >
09/17/2013 09/17/2013
15:28:12 16:01:41
< System operator >
09/17/2013 09/17/2013
15:28:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:28:59 16:01:41
< System operator >
09/17/2013 09/17/2013
15:29:02 16:01:41
< System operator >

Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:29:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:29:22
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:21:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:31:01
No.=0, PassNo=255,
High Humidity
2380
Alarm BBBL3/EH01_TanjgLabu
GBTS
Site No.=41,EH01_TanjgLabu
Board Type=EAC,
09/17/2013
Board
11:28:29
No.=0, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:30:45
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:31:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:32:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:32:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:32:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:32:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:33:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:34:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:34:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:34:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:36:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:37:28
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
15:08:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=0,
15:19:29
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:38:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
15:39:05
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
15:46:35
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:45:37
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:45:53
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:46:52
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:47:52
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:48:00
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:48:42
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:51:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
15:51:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:51:28
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:53:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:53:20
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:51:33
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:53:32
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:52:51
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:53:42
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:49:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:54:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:55:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:55:28
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:53:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:55:39
No.=0, PassNo=255,
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
14:36:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:55:57
No.=0, PassNo=255,
AC L3 Failure
6450
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
15:55:41
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
15:55:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
15:55:41
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
15:55:07
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:56:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:56:26
No.=0, PassNo=255,

09/17/2013 09/17/2013
15:29:12 16:01:41
< System operator >
09/17/2013 09/17/2013
15:29:26 16:01:41
< System operator >
09/17/2013 09/17/2013
15:29:59 16:01:41
< System operator >
09/17/2013 09/17/2013
15:31:02 16:01:41
< System operator >
09/17/2013 -15:31:19 09/17/2013 09/17/2013
15:31:27 16:01:41
< System operator >
09/17/2013 09/17/2013
15:32:00 16:01:41
< System operator >
09/17/2013 09/17/2013
15:32:13 16:01:41
< System operator >
09/17/2013 09/17/2013
15:32:26 16:01:41
< System operator >
09/17/2013 09/17/2013
15:32:47 16:01:41
< System operator >
09/17/2013 09/17/2013
15:33:02 16:01:41
< System operator >
09/17/2013 09/17/2013
15:33:56 16:01:41
< System operator >
09/17/2013 09/17/2013
15:34:14 16:01:41
< System operator >
09/17/2013 09/17/2013
15:34:48 16:01:41
< System operator >
09/17/2013 09/17/2013
15:34:59 16:01:41
< System operator >
09/17/2013 09/17/2013
15:36:17 16:01:41
< System operator >
09/17/2013 09/17/2013
15:37:29 16:01:41
< System operator >
09/17/2013 09/17/2013
15:38:10 18:06:47
< System operator >
09/17/2013 09/17/2013
15:38:31 18:06:47
< System operator >
09/17/2013 09/17/2013
15:39:01 16:01:41
< System operator >
09/17/2013 09/17/2013
15:39:07 16:57:41
< System operator >
09/17/2013 09/17/2013
15:46:37 16:57:41
< System operator >
09/17/2013 09/17/2013
15:46:49 16:01:41
< System operator >
09/17/2013 09/17/2013
15:46:52 18:06:47
< System operator >
09/17/2013 09/17/2013
15:47:49 16:01:41
< System operator >
09/17/2013 09/17/2013
15:47:56 16:01:41
< System operator >
09/17/2013 09/17/2013
15:48:39 16:01:41
< System operator >
09/17/2013 09/17/2013
15:49:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:51:46 16:57:41
< System operator >
09/17/2013 09/17/2013
15:51:59 18:06:47
< System operator >
09/17/2013 09/17/2013
15:52:29 16:01:41
< System operator >
09/17/2013 09/17/2013
15:53:04 16:01:41
< System operator >
09/17/2013 09/17/2013
15:53:28 16:01:41
< System operator >
09/17/2013 09/17/2013
15:53:30 16:57:41
< System operator >
09/17/2013 09/17/2013
15:53:34 16:01:41
< System operator >
09/17/2013 09/17/2013
15:53:40 16:57:41
< System operator >
09/17/2013 09/17/2013
15:53:45 16:01:41
< System operator >
09/17/2013 09/17/2013
15:53:46 16:01:41
< System operator >
09/17/2013 09/17/2013
15:54:14 16:01:41
< System operator >
09/17/2013 09/17/2013
15:54:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:54:36 16:01:41
< System operator >
09/17/2013 09/17/2013
15:54:42 16:01:41
< System operator >
09/17/2013 09/17/2013
15:54:47 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:04 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:21 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:35 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:43 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:47 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:58 16:01:41
< System operator >
09/17/2013 09/17/2013
15:55:59 16:57:41
< System operator >
09/17/2013 09/17/2013
15:55:59 16:57:41
< System operator >
09/17/2013 09/17/2013
15:55:59 16:57:41
< System operator >
09/17/2013 09/17/2013
15:56:20 16:57:41
< System operator >
09/17/2013 09/17/2013
15:56:24 16:01:41
< System operator >
09/17/2013 09/17/2013
15:56:32 16:01:41
< System operator >

Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Major
Minor
Major
Minor
Major
Major
Major
Major
Major

AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:55:36
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:56:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:57:34
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:57:38
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:57:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:58:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:58:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:59:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:59:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:59:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
15:59:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:00:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:01:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:01:45
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
16:03:59
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:02:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:04:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:04:59
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:07:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:08:09
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
15:57:47
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:10:56
No.=0, PassNo=255,
Temperature
9738
high or low
BBBL3/2272367L2_Koba3
alarm
GBTS
Site No.=18,2272367L2_Koba3
Board Type=NFCB,
09/17/2013Board
12:42:10
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
16:13:29
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
16:15:19
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:12:07
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:14:54
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
16:16:50
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:19:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:19:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:20:14
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:20:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:20:39
No.=0, PassNo=255,
Rectifier Module
6442 Fault Alarm
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
15:56:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:21:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:22:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:22:22
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:14:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:16:50
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:15:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:23:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:23:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:23:47
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:22:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:24:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
16:24:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
16:23:49
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:25:06
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:24:14
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:25:18
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:24:28
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:25:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:25:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:25:49
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
16:26:49
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:27:03
No.=0, PassNo=255,

09/17/2013 09/17/2013
15:56:49 16:01:41
< System operator >
09/17/2013 09/17/2013
15:57:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:57:37 16:01:41
< System operator >
09/17/2013 09/17/2013
15:57:41 16:01:41
< System operator >
09/17/2013 09/17/2013
15:57:44 16:01:41
< System operator >
09/17/2013 09/17/2013
15:58:24 16:01:41
< System operator >
09/17/2013 09/17/2013
15:58:32 16:01:41
< System operator >
09/17/2013 09/17/2013
15:59:22 16:01:41
< System operator >
09/17/2013 09/17/2013
15:59:34 16:01:41
< System operator >
09/17/2013 09/17/2013
15:59:47 16:01:41
< System operator >
09/17/2013 09/17/2013
16:00:38 16:01:41
< System operator >
09/17/2013 09/17/2013
16:00:43 16:01:41
< System operator >
09/17/2013 09/17/2013
16:01:07 16:57:41
< System operator >
09/17/2013 09/17/2013
16:02:53 16:57:41
< System operator >
09/17/2013 09/17/2013
16:04:01 16:57:41
< System operator >
09/17/2013 09/17/2013
16:04:19 16:57:41
< System operator >
09/17/2013 09/17/2013
16:04:57 16:57:41
< System operator >
09/17/2013 09/17/2013
16:05:01 16:57:41
< System operator >
09/17/2013 09/17/2013
16:08:05 16:57:41
< System operator >
09/17/2013 09/17/2013
16:08:11 16:57:41
< System operator >
09/17/2013 09/17/2013
16:10:54 16:57:41
< System operator >
09/17/2013 09/17/2013
16:11:03 16:57:41
< System operator >
09/17/2013 09/17/2013
16:13:18 16:57:41
< System operator >
09/17/2013 09/17/2013
16:13:31 16:57:41
< System operator >
09/17/2013 09/17/2013
16:15:21 16:57:41
< System operator >
09/17/2013 09/17/2013
16:15:36 16:57:41
< System operator >
09/17/2013 09/17/2013
16:15:38 16:57:41
< System operator >
09/17/2013 09/17/2013
16:17:27 16:57:41
< System operator >
09/17/2013 09/17/2013
16:19:54 16:57:41
< System operator >
09/17/2013 09/17/2013
16:20:00 16:57:41
< System operator >
09/17/2013 09/17/2013
16:20:16 16:57:41
< System operator >
09/17/2013 09/17/2013
16:20:27 16:57:41
< System operator >
09/17/2013 09/17/2013
16:20:40 16:57:41
< System operator >
09/17/2013 09/17/2013
16:20:57 18:06:47
< System operator >
09/17/2013 09/17/2013
16:21:41 16:57:41
< System operator >
09/17/2013 09/17/2013
16:22:21 16:57:41
< System operator >
09/17/2013 09/17/2013
16:22:25 16:57:41
< System operator >
09/17/2013 09/17/2013
16:22:31 16:57:41
< System operator >
09/17/2013 09/17/2013
16:22:35 16:57:41
< System operator >
09/17/2013 09/17/2013
16:23:11 16:57:41
< System operator >
09/17/2013 09/17/2013
16:23:29 16:57:41
< System operator >
09/17/2013 09/17/2013
16:23:42 16:57:41
< System operator >
09/17/2013 09/17/2013
16:23:48 16:57:41
< System operator >
09/17/2013 09/17/2013
16:23:57 16:57:41
< System operator >
09/17/2013 09/17/2013
16:24:15 16:57:41
< System operator >
09/17/2013 09/17/2013
16:24:47 18:06:47
< System operator >
09/17/2013 09/17/2013
16:24:48 18:06:47
< System operator >
09/17/2013 09/17/2013
16:25:09 16:57:41
< System operator >
09/17/2013 09/17/2013
16:25:19 16:57:41
< System operator >
09/17/2013 09/17/2013
16:25:21 16:57:41
< System operator >
09/17/2013 09/17/2013
16:25:23 18:06:47
< System operator >
09/17/2013 09/17/2013
16:25:25 16:57:41
< System operator >
09/17/2013 09/17/2013
16:25:30 16:57:41
< System operator >
09/17/2013 09/17/2013
16:25:51 16:57:41
< System operator >
09/17/2013 09/17/2013
16:26:52 18:06:47
< System operator >
09/17/2013 09/17/2013
16:27:05 16:57:41
< System operator >

Major
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:27:30
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:26:44
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:23:13
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:25:20
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:29:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:29:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:29:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:30:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:30:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:30:37
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:29:59
No.=0, PassNo=255,
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
16:34:07
No.=0, Board Type=EMU
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:35:48
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:35:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:33:58
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:36:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:36:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:36:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:37:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:38:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:38:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:38:38
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:32:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:39:17
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:38:14
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:39:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:40:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:40:12
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:39:09
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:40:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:42:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:43:03
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:44:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:46:41
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:39:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:49:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:49:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:50:12
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:50:33
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:50:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:51:43
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:51:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:54:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:54:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:54:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:55:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:55:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:56:57
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:54:58
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:53:55
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:57:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:57:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:58:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
16:58:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:58:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:58:56
No.=0, PassNo=255,

09/17/2013 09/17/2013
16:27:33 16:57:41
< System operator >
09/17/2013 09/17/2013
16:27:37 16:57:41
< System operator >
09/17/2013 09/17/2013
16:28:05 16:57:41
< System operator >
09/17/2013 09/17/2013
16:28:58 16:57:41
< System operator >
09/17/2013 09/17/2013
16:29:24 16:57:41
< System operator >
09/17/2013 09/17/2013
16:29:43 16:57:41
< System operator >
09/17/2013 09/17/2013
16:30:03 16:57:41
< System operator >
09/17/2013 09/17/2013
16:30:18 16:57:41
< System operator >
09/17/2013 09/17/2013
16:30:27 16:57:41
< System operator >
09/17/2013 09/17/2013
16:30:40 16:57:41
< System operator >
09/17/2013 09/17/2013
16:32:06 16:57:41
< System operator >
09/17/2013 09/17/2013
16:35:04 16:57:41
< System operator >
09/17/2013 09/17/2013
16:35:50 16:57:41
< System operator >
09/17/2013 09/17/2013
16:36:14 16:57:41
< System operator >
09/17/2013 09/17/2013
16:36:14 16:57:41
< System operator >
09/17/2013 09/17/2013
16:36:23 16:57:41
< System operator >
09/17/2013 09/17/2013
16:36:46 16:57:41
< System operator >
09/17/2013 09/17/2013
16:36:55 16:57:41
< System operator >
09/17/2013 09/17/2013
16:37:28 16:57:41
< System operator >
09/17/2013 09/17/2013
16:38:12 16:57:41
< System operator >
09/17/2013 09/17/2013
16:38:23 16:57:41
< System operator >
09/17/2013 09/17/2013
16:38:40 16:57:41
< System operator >
09/17/2013 09/17/2013
16:38:58 16:57:41
< System operator >
09/17/2013 09/17/2013
16:39:18 16:57:41
< System operator >
09/17/2013 09/17/2013
16:39:39 18:06:47
< System operator >
09/17/2013 09/17/2013
16:39:43 16:57:41
< System operator >
09/17/2013 09/17/2013
16:40:06 16:57:41
< System operator >
09/17/2013 09/17/2013
16:40:14 16:57:41
< System operator >
09/17/2013 09/17/2013
16:40:39 18:06:47
< System operator >
09/17/2013 09/17/2013
16:41:00 16:57:41
< System operator >
09/17/2013 09/17/2013
16:42:40 16:57:41
< System operator >
09/17/2013 09/17/2013
16:43:06 16:57:41
< System operator >
09/17/2013 09/17/2013
16:44:10 16:57:41
< System operator >
09/17/2013 09/17/2013
16:46:42 16:57:41
< System operator >
09/17/2013 09/17/2013
16:48:13 16:57:41
< System operator >
09/17/2013 09/17/2013
16:49:41 16:57:41
< System operator >
09/17/2013 09/17/2013
16:49:59 16:57:41
< System operator >
09/17/2013 09/17/2013
16:50:14 18:06:47
< System operator >
09/17/2013 09/17/2013
16:50:35 16:57:41
< System operator >
09/17/2013 09/17/2013
16:51:43 16:57:41
< System operator >
09/17/2013 09/17/2013
16:51:45 16:57:41
< System operator >
09/17/2013 09/17/2013
16:53:53 16:57:41
< System operator >
09/17/2013 09/17/2013
16:54:18 16:57:41
< System operator >
09/17/2013 09/17/2013
16:54:23 16:57:41
< System operator >
09/17/2013 09/17/2013
16:54:27 16:57:41
< System operator >
09/17/2013 09/17/2013
16:55:10 16:57:41
< System operator >
09/17/2013 09/17/2013
16:55:53 16:57:41
< System operator >
09/17/2013 09/17/2013
16:56:59 18:06:47
< System operator >
09/17/2013 09/17/2013
16:57:08 18:06:47
< System operator >
09/17/2013 09/17/2013
16:57:14 16:57:41
< System operator >
09/17/2013 09/17/2013
16:57:19 16:57:41
< System operator >
09/17/2013 09/17/2013
16:57:50 18:06:47
< System operator >
09/17/2013 09/17/2013
16:58:13 18:06:47
< System operator >
09/17/2013 09/17/2013
16:58:46 18:06:47
< System operator >
09/17/2013 09/17/2013
16:58:51 18:06:47
< System operator >
09/17/2013 09/17/2013
16:59:19 18:06:47
< System operator >

Major
Minor
Minor
Minor
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Minor
Minor
Minor
Minor
Major
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
16:59:25
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
16:57:22
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:00:21
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:00:26
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:00:35
No.=0, PassNo=255,
Over Temperature
2376 Alarm
BBBL3/D648_AirGergas[HUB]
GBTS
Site No.=8, D648_AirGergas[HUB]
Board Type=EAC,
09/17/2013
Board
14:19:18
No.=0, PassNo=255, Sub
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:01:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:01:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:01:27
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:01:10
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:02:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:02:19
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
17:02:43
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:00:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:02:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:03:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:03:33
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:00:54
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:02:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:03:51
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:02:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
16:59:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:05:36
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:04:30
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:05:36
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:06:00
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:06:06
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:06:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:07:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:07:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:08:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:08:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:08:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:08:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:09:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:10:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:10:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:10:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:10:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:11:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:11:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:12:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:12:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:12:14
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
17:12:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:13:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:13:14
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:13:29
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:14:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:15:11
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:15:45
No.=0, PassNo=255,

09/17/2013 09/17/2013
16:59:28 18:06:47
< System operator >
09/17/2013 09/17/2013
16:59:49 18:06:47
< System operator >
09/17/2013 09/17/2013
16:59:49 18:06:47
< System operator >
09/17/2013 09/17/2013
16:59:49 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:20 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:30 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:38 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:45 18:06:47
< System operator >
09/17/2013 09/17/2013
17:00:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:01:19 18:06:47
< System operator >
09/17/2013 09/17/2013
17:01:41 18:06:47
< System operator >
09/17/2013 09/17/2013
17:01:41 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:07 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:11 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:21 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:45 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:54 18:06:47
< System operator >
09/17/2013 09/17/2013
17:02:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:37 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:41 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:49 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:54 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:57 18:06:47
< System operator >
09/17/2013 09/17/2013
17:03:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:04:53 18:06:47
< System operator >
09/17/2013 09/17/2013
17:05:09 18:06:47
< System operator >
09/17/2013 09/18/2013
17:05:54 03:10:45
< System operator >
09/17/2013 09/17/2013
17:05:58 18:06:47
< System operator >
09/17/2013 09/18/2013
17:06:10 03:10:45
< System operator >
09/17/2013 09/17/2013
17:06:10 18:06:47
< System operator >
09/17/2013 09/17/2013
17:06:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:06:36 18:06:47
< System operator >
09/17/2013 09/17/2013
17:07:44 18:06:47
< System operator >
09/17/2013 09/17/2013
17:07:54 18:06:47
< System operator >
09/17/2013 09/17/2013
17:08:22 18:06:47
< System operator >
09/17/2013 09/17/2013
17:08:29 18:06:47
< System operator >
09/17/2013 09/17/2013
17:08:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:08:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:09:38 18:06:47
< System operator >
09/17/2013 09/17/2013
17:10:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:10:42 18:06:47
< System operator >
09/17/2013 09/17/2013
17:10:54 18:06:47
< System operator >
09/17/2013 09/17/2013
17:10:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:11:40 18:06:47
< System operator >
09/17/2013 09/17/2013
17:11:54 18:06:47
< System operator >
09/17/2013 09/17/2013
17:12:02 18:06:47
< System operator >
09/17/2013 09/17/2013
17:12:08 18:06:47
< System operator >
09/17/2013 09/17/2013
17:12:16 18:06:47
< System operator >
09/17/2013 09/17/2013
17:13:04 20:44:29
< System operator >
09/17/2013 09/17/2013
17:13:05 18:06:47
< System operator >
09/17/2013 09/17/2013
17:13:18 18:06:47
< System operator >
09/17/2013 09/17/2013
17:13:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:15:09 18:06:47
< System operator >
09/17/2013 09/17/2013
17:15:13 18:06:47
< System operator >
09/17/2013 09/17/2013
17:15:47 18:06:47
< System operator >

Minor
Major
Major
Major
Major
Minor
Minor
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Minor

E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:15:11
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:16:41
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:15:13
No.=0, PassNo=255,
AC L1 failure
2410
alarm
BBBL3/DF50_BatuBeriga
GBTS
Site No.=2, DF50_BatuBeriga
Board Type=EAC,
09/17/2013
Board
16:10:38
No.=0, PassNo=255, Sub
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:17:35
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:19:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:20:06
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:19:32
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:20:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:21:58
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:19:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:23:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:23:28
No.=0, PassNo=255,
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
16:41:03
No.=0, Board Type=EMU
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:24:07
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:24:40
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:22:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:25:31
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:22:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:22:39
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:19:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:27:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:27:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:27:59
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:28:52
No.=0, PassNo=255,
AC L3 Failure
6450
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
16:20:51
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
16:20:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A807_Trans2nyelending
GBTS
Site No.=28,227A807_Trans2nyelending
Board Type=DEMU,
09/17/2013Board
16:20:51
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:28:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:28:32
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:29:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:29:48
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:28:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:30:04
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:30:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:30:58
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:29:58
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:31:26
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:27:59
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:31:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:31:39
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:31:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:31:55
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:31:58
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:32:05
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:32:05
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:32:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:32:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:32:44
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:32:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:33:14
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:33:23
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:33:40
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
15:38:09
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
17:16:03 18:06:47
< System operator >
09/17/2013 09/17/2013
17:16:43 18:06:47
< System operator >
09/17/2013 09/17/2013
17:17:31 18:06:47
< System operator >
09/17/2013 09/18/2013
17:19:30 07:13:57
< System operator >
09/17/2013 09/17/2013
17:19:32 18:06:47
< System operator >
09/17/2013 09/17/2013
17:19:34 19:06:44
< System operator >
09/17/2013 09/17/2013
17:19:34 18:06:47
< System operator >
09/17/2013 09/17/2013
17:19:45 18:06:47
< System operator >
09/17/2013 09/17/2013
17:20:07 18:06:47
< System operator >
09/17/2013 09/17/2013
17:20:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:20:55 18:06:47
< System operator >
09/17/2013 09/17/2013
17:22:02 18:06:47
< System operator >
09/17/2013 09/17/2013
17:22:42 18:06:47
< System operator >
09/17/2013 09/17/2013
17:23:26 18:06:47
< System operator >
09/17/2013 09/17/2013
17:23:30 18:06:47
< System operator >
09/17/2013 09/17/2013
17:23:48 18:06:47
< System operator >
09/17/2013 09/17/2013
17:24:09 18:06:47
< System operator >
09/17/2013 09/17/2013
17:24:42 18:06:47
< System operator >
09/17/2013 09/17/2013
17:25:08 18:06:47
< System operator >
09/17/2013 09/17/2013
17:25:34 18:06:47
< System operator >
09/17/2013 09/17/2013
17:26:01 19:06:44
< System operator >
09/17/2013 09/17/2013
17:26:56 19:06:44
< System operator >
09/17/2013 09/17/2013
17:26:59 19:06:44
< System operator >
09/17/2013 09/17/2013
17:27:51 18:06:47
< System operator >
09/17/2013 09/17/2013
17:27:51 18:06:47
< System operator >
09/17/2013 09/17/2013
17:28:00 18:06:47
< System operator >
09/17/2013 09/17/2013
17:28:54 18:06:47
< System operator >
09/17/2013 -17:28:57 09/17/2013 -17:28:57 09/17/2013 -17:28:57 09/17/2013 09/17/2013
17:29:00 18:06:47
< System operator >
09/17/2013 09/17/2013
17:29:04 18:06:47
< System operator >
09/17/2013 09/17/2013
17:29:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:29:51 18:06:47
< System operator >
09/17/2013 09/17/2013
17:29:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:30:08 18:06:47
< System operator >
09/17/2013 09/17/2013
17:30:47 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:00 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:28 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:29 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:30 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:33 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:40 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:52 18:06:47
< System operator >
09/17/2013 09/17/2013
17:31:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:03 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:06 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:06 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:21 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:32:47 18:06:47
< System operator >
09/17/2013 09/17/2013
17:33:03 18:06:47
< System operator >
09/17/2013 09/17/2013
17:33:16 18:06:47
< System operator >
09/17/2013 09/17/2013
17:33:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:34:05 18:06:47
< System operator >
09/17/2013 09/17/2013
17:34:16 18:06:47
< System operator >

Minor
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Minor
Major
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Minor
Minor
Minor

E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=0,
15:38:30
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:32:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:32:07
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:34:07
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:35:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:35:32
No.=0, PassNo=255,
Over Temperature
6412 Alarm
BBBL3/227A812_Penutuk
GBTS
Site No.=45,227A812_Penutuk
Board Type=DEMU,
09/17/2013Board
15:54:25
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:35:52
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:37:13
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:35:30
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:37:41
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:27:50
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:37:47
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
17:34:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:37:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:37:51
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:38:17
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
17:38:34
No.=0, PassNo=255, S
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
17:27:03
No.=0, Board Type=EMU
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:40:29
No.=0, PassNo=255,
Rectifier Failure
65049
BBBL3/227B762_GadungTimur
GBTS
Cabinet No.=0,
227B762_GadungTimur
Subrack
09/17/2013
No.=40, Slot
17:40:08
No.=0, Port No.=8, Board
AC L3 failure
2414
alarm
BBBL3/4153_GadungBngk
GBTS
Site No.=38,4153_GadungBngk
Board Type=EAC,
09/17/2013
Board
17:39:47
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/4153_GadungBngk
GBTS
Site No.=38,4153_GadungBngk
Board Type=EAC,
09/17/2013
Board
17:39:47
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/4153_GadungBngk
GBTS
Site No.=38,4153_GadungBngk
Board Type=EAC,
09/17/2013
Board
17:39:47
No.=0, PassNo=255, Su
PSU shutdown
5648alarm BBBL3/227A829_SmpgNnsTbli
GBTS
Site No.=43,227A829_SmpgNnsTbli
Board Type=DPMU,
09/17/2013Board
17:40:38
No.=0, PassNo=255,
PSU shutdown
5648alarm BBBL3/227A829_SmpgNnsTbli
GBTS
Site No.=43,227A829_SmpgNnsTbli
Board Type=DPMU,
09/17/2013Board
17:40:38
No.=0, PassNo=255,
PSU shutdown
5648alarm BBBL3/227A829_SmpgNnsTbli
GBTS
Site No.=43,227A829_SmpgNnsTbli
Board Type=DPMU,
09/17/2013Board
17:40:38
No.=0, PassNo=255,
BTS3012AE5672
AC Arrester
BBBL3/227A829_SmpgNnsTbli
Failure GBTS
Site No.=43,227A829_SmpgNnsTbli
Board Type=DPMU,
09/17/2013Board
17:40:32
No.=0, PassNo=255,
No AC Input5700
Alarm
BBBL3/227A829_SmpgNnsTbli
GBTS
Site No.=43,227A829_SmpgNnsTbli
Board Type=DPMU,
09/17/2013Board
17:40:49
No.=0, PassNo=255,
AC L2 Failure
65035
BBBL3/227B762_GadungTimur
GBTS
Cabinet No.=0,
227B762_GadungTimur
Subrack
09/17/2013
No.=40, Slot
17:40:04
No.=0, Port No.=1, Board
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:42:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:42:59
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:38:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:44:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:45:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:45:18
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:46:17
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:46:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:47:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=0,
17:34:37
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:49:27
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:51:22
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:44:28
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:53:14
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:51:27
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:53:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:53:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:54:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:54:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:54:36
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:01:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:00:43
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:55:16
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:01:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:00:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
17:52:12
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
17:34:39 18:06:47
< System operator >
09/17/2013 09/17/2013
17:34:40 18:06:47
< System operator >
09/17/2013 09/17/2013
17:34:43 18:06:47
< System operator >
09/17/2013 09/17/2013
17:34:55 18:06:47
< System operator >
09/17/2013 09/17/2013
17:35:29 18:06:47
< System operator >
09/17/2013 09/17/2013
17:35:34 18:06:47
< System operator >
09/17/2013 -17:35:54 09/17/2013 09/17/2013
17:36:13 18:06:47
< System operator >
09/17/2013 09/17/2013
17:37:15 18:06:47
< System operator >
09/17/2013 09/17/2013
17:37:29 18:06:47
< System operator >
09/17/2013 09/17/2013
17:37:45 18:06:47
< System operator >
09/17/2013 09/17/2013
17:37:52 18:06:47
< System operator >
09/17/2013 09/17/2013
17:38:15 18:06:47
< System operator >
09/17/2013 09/17/2013
17:38:16 20:44:29
< System operator >
09/17/2013 09/17/2013
17:38:20 18:06:47
< System operator >
09/17/2013 09/17/2013
17:38:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:38:27 18:06:47
< System operator >
09/17/2013 09/17/2013
17:38:36 19:06:44
< System operator >
09/17/2013 09/17/2013
17:39:42 18:06:47
< System operator >
09/17/2013 09/17/2013
17:40:32 18:06:47
< System operator >
09/17/2013 -17:40:52 09/17/2013 -17:41:04 09/17/2013 -17:41:04 09/17/2013 -17:41:04 09/17/2013 -17:41:11 09/17/2013 -17:41:11 09/17/2013 -17:41:11 09/17/2013 -17:41:11 09/17/2013 -17:41:22 09/17/2013 -17:42:18 09/17/2013 09/17/2013
17:42:49 18:06:47
< System operator >
09/17/2013 09/17/2013
17:43:01 18:06:47
< System operator >
09/17/2013 09/17/2013
17:44:25 18:06:47
< System operator >
09/17/2013 09/17/2013
17:44:27 18:06:47
< System operator >
09/17/2013 09/17/2013
17:45:01 18:06:47
< System operator >
09/17/2013 09/17/2013
17:45:19 18:06:47
< System operator >
09/17/2013 09/17/2013
17:47:01 20:03:17
< System operator >
09/17/2013 09/17/2013
17:47:19 20:03:17
< System operator >
09/17/2013 09/17/2013
17:48:25 18:06:47
< System operator >
09/17/2013 -17:49:38 09/17/2013 09/17/2013
17:49:51 18:06:47
< System operator >
09/17/2013 09/17/2013
17:51:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:51:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:53:15 18:06:47
< System operator >
09/17/2013 09/17/2013
17:53:20 18:06:47
< System operator >
09/17/2013 09/17/2013
17:53:24 18:06:47
< System operator >
09/17/2013 09/17/2013
17:53:58 18:06:47
< System operator >
09/17/2013 09/17/2013
17:54:26 18:06:47
< System operator >
09/17/2013 09/17/2013
17:54:31 18:06:47
< System operator >
09/17/2013 09/17/2013
17:54:38 18:06:47
< System operator >
09/17/2013 09/17/2013
17:54:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:54:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:55:18 18:06:47
< System operator >
09/17/2013 09/17/2013
17:55:35 18:06:47
< System operator >
09/17/2013 09/17/2013
17:55:35 18:06:47
< System operator >
09/17/2013 09/18/2013
17:56:12 00:59:18
< System operator >

Major
Minor
Minor
Minor
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:56:36
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:54:00
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:53:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:53:14
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:57:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:57:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:57:54
No.=0, PassNo=255,
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
17:43:18
No.=0, Board Type=EMU
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
17:58:06
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
17:57:59
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:59:13
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:01:24
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:01:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:01:57
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
17:59:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:02:28
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:02:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:02:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:02:41
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:02:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:02:55
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:03:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:03:08
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:03:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:04:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:04:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
18:05:07
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:04:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:04:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:06:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:06:04
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:08:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:06:16
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:02:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:09:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:03:08
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:10:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:10:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:10:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:10:55
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
18:02:18
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
18:12:30
No.=0, PassNo=255,
AC L3 Failure
65037
BBBL3/227B762_GadungTimur
GBTS
Cabinet No.=0,
227B762_GadungTimur
Subrack
09/17/2013
No.=40, Slot
17:40:04
No.=0, Port No.=2, Board
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:12:42
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
18:02:11
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:11:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:17:53
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:17:48
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:10:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:10:55
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
18:14:35
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:22:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:22:07
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:22:47
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
17:56:38 18:06:47
< System operator >
09/17/2013 09/17/2013
17:56:46 19:06:44
< System operator >
09/17/2013 09/17/2013
17:56:53 23:50:52
< System operator >
09/17/2013 09/17/2013
17:56:59 19:06:44
< System operator >
09/17/2013 09/17/2013
17:57:39 18:06:47
< System operator >
09/17/2013 09/17/2013
17:57:48 18:06:47
< System operator >
09/17/2013 09/17/2013
17:57:56 18:06:47
< System operator >
09/17/2013 09/17/2013
17:58:06 18:06:47
< System operator >
09/17/2013 09/17/2013
17:58:11 18:06:47
< System operator >
09/17/2013 09/17/2013
17:58:41 18:06:47
< System operator >
09/17/2013 09/17/2013
17:59:35 18:06:47
< System operator >
09/17/2013 09/17/2013
18:01:26 18:06:47
< System operator >
09/17/2013 09/17/2013
18:01:49 18:06:47
< System operator >
09/17/2013 09/17/2013
18:01:59 18:06:47
< System operator >
09/17/2013 09/17/2013
18:02:15 18:06:47
< System operator >
09/17/2013 09/17/2013
18:02:29 18:06:47
< System operator >
09/17/2013 09/17/2013
18:02:42 19:06:44
< System operator >
09/17/2013 09/17/2013
18:02:42 19:06:44
< System operator >
09/17/2013 09/17/2013
18:02:42 18:06:47
< System operator >
09/17/2013 09/17/2013
18:02:43 18:06:47
< System operator >
09/17/2013 09/17/2013
18:02:56 18:06:47
< System operator >
09/17/2013 09/17/2013
18:03:09 19:06:44
< System operator >
09/17/2013 09/17/2013
18:03:09 18:06:47
< System operator >
09/17/2013 09/17/2013
18:03:21 18:06:47
< System operator >
09/17/2013 09/17/2013
18:04:27 18:06:47
< System operator >
09/17/2013 09/17/2013
18:04:37 18:06:47
< System operator >
09/17/2013 09/17/2013
18:05:10 20:03:17
< System operator >
09/17/2013 09/17/2013
18:05:26 18:06:47
< System operator >
09/17/2013 09/17/2013
18:05:35 18:06:47
< System operator >
09/17/2013 09/17/2013
18:06:12 18:06:47
< System operator >
09/17/2013 09/17/2013
18:08:10 19:06:44
< System operator >
09/17/2013 09/18/2013
18:08:56 00:59:18
< System operator >
09/17/2013 09/17/2013
18:09:01 19:06:44
< System operator >
09/17/2013 09/17/2013
18:09:47 19:06:44
< System operator >
09/17/2013 09/17/2013
18:10:28 23:50:52
< System operator >
09/17/2013 09/18/2013
18:10:29 00:59:18
< System operator >
09/17/2013 09/17/2013
18:10:32 19:06:44
< System operator >
09/17/2013 09/17/2013
18:10:32 19:06:44
< System operator >
09/17/2013 09/17/2013
18:10:56 19:06:44
< System operator >
09/17/2013 09/17/2013
18:10:56 19:06:44
< System operator >
09/17/2013 09/17/2013
18:12:27 19:06:44
< System operator >
09/17/2013 09/17/2013
18:14:32 19:06:44
< System operator >
09/17/2013 -18:14:43 09/17/2013 09/17/2013
18:15:58 19:06:44
< System operator >
09/17/2013 09/17/2013
18:16:08 19:06:44
< System operator >
09/17/2013 09/17/2013
18:17:16 19:06:44
< System operator >
09/17/2013 09/17/2013
18:19:05 19:06:44
< System operator >
09/17/2013 09/17/2013
18:19:05 19:06:44
< System operator >
09/17/2013 09/17/2013
18:19:54 19:06:44
< System operator >
09/17/2013 09/17/2013
18:19:58 19:06:44
< System operator >
09/17/2013 09/17/2013
18:21:24 19:06:44
< System operator >
09/17/2013 09/17/2013
18:22:32 19:06:44
< System operator >
09/17/2013 09/17/2013
18:22:35 19:06:44
< System operator >
09/17/2013 09/17/2013
18:22:35 19:06:44
< System operator >
09/17/2013 09/17/2013
18:22:35 23:50:52
< System operator >
09/17/2013 09/17/2013
18:24:02 19:06:44
< System operator >

Major
Minor
Minor
Minor
Minor
Minor
Major
Minor
Major
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Minor
Minor
Minor
Major
Major
Critical
Major
Minor
Critical
Critical
Warning
Minor
Critical
Critical
Critical
Major
Minor
Minor
Minor
Major
Major
Major

AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
18:21:27
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
18:24:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:24:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:22:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:31:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:32:40
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
18:26:05
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:34:52
Subsystem
No.=0, E1/T1
No.=0
Port No
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
18:28:14
No.=0, Board Type=EMU
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:39:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:40:01
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
18:41:14
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
18:44:55
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
18:44:48
Subsystem
No.=0, E1/T1
No.=0
Port No
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
18:45:56
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
18:46:57
No.=0, PassNo=255, S
E1/T1 Excessive
25806Bit Error
BBBL3/2273580_GudangSimpangRimba
Rate GBTS
Cabinet No.=0,
2273580_GudangSimpangRimba
Subrack
09/17/2013
No.=0, Slot
18:35:37
No.=6, Port No.=0, Site N
EAC Communication
2384
Alarm
BBBL3/D647_Bencah[HUB]
GBTS
Site No.=40,D647_Bencah[HUB]
Board Type=EAC,
09/17/2013
Board
18:53:46
No.=0, PassNo=255, Su
Ambient Temperature
25650
Unacceptable
BBBL3/DA30_IRAT_Swap
GBTS
Cabinet No.=0,
DA30_IRAT_Swap
Subrack
09/17/2013
No.=40, Slot
18:50:40
No.=0, Board Type=EMU
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
19:11:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
19:11:28
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=1,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=1,
19:11:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
19:11:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=1,
19:11:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=1,
19:11:24
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=1,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=1,
19:11:29
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
25801
IndicationBBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
19:11:25
No.=6, Port No.=1, Site N
E1/T1 Alarm
25801
IndicationBBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
19:11:25
No.=6, Port No.=0, Site N
Genset Failure
2420
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=EAC,
09/17/2013
Board
19:11:42
No.=0, PassNo=255, Su
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=25,
Slot No.=25,
09/17/2013
Subrack
Subsystem
No=1,
19:11:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
19:11:11
Subsystem
No.=0, E1/T1
No.=0
Port No
E1 Remote 2216
Alarm
BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=TMU,
09/17/2013
Board
19:13:02
No.=0, PassNo=255, Su
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:13:43
No.=0, PassNo=255, S
Rectifier module
2406 fault BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=EAC,
09/17/2013
Board
19:13:42
No.=0, PassNo=255, Su
OML Fault 21807
BBBL3/4144_TepusBngk
GBTS
Site Index=13,
4144_TepusBngk
BSC Subrack
09/17/2013
No.=0,
19:13:00
BSC Slot No.=20, E1 No.=
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:15:02
No.=0, PassNo=255, S
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=0,
19:14:42
Subsystem
No.=0, E1/T1
No.=0
Port No
GSM Cell out
21801
of Service
BBBL3/4144_TepusBngk
GBTS
Site Index=13,
LABEL=4144_TepusBngk-2,
Cell Index=40,
09/17/2013
Alarm
19:12:55
Cause=Other
CellIndex=40,
causes,
CGI=51
Site
GSM Cell out
21801
of Service
BBBL3/4144_TepusBngk
GBTS
Site Index=13,
LABEL=4144_TepusBngk-1,
Cell Index=39,
09/17/2013
Alarm
19:12:55
Cause=Other
CellIndex=39,
causes,
CGI=51
Site
Site Reset Alarm
4770
BBBL3/2271800L1_TpsBngk2
GBTS
Site No.=19,2271800L1_TpsBngk2
Board Type=DTMU,
09/17/2013Board
19:13:50
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
19:15:21
Subsystem
No.=0, E1/T1
No.=0
Port No
GSM Cell out
21801
of Service
BBBL3/2271800L1_TpsBngk2
GBTS
Site Index=19,
LABEL=1800L1_TpsBngk2-6,
Cell Index=59,
09/17/2013
Alarm
19:12:52
Cause=Other
CellIndex=59,
causes,
CGI=5
Site
GSM Cell out
21801
of Service
BBBL3/2271800L1_TpsBngk2
GBTS
Site Index=19,
LABEL=1800L1_TpsBngk2-5,
Cell Index=58,
09/17/2013
Alarm
19:12:52
Cause=Other
CellIndex=58,
causes,
CGI=5
Site
GSM Cell out
21801
of Service
BBBL3/2271800L1_TpsBngk2
GBTS
Site Index=19,
LABEL=1800L1_TpsBngk2-4,
Cell Index=57,
09/17/2013
Alarm
19:12:52
Cause=Other
CellIndex=57,
causes,
CGI=5
Site
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:20:03
No.=0, PassNo=255, S
E1 Remote 2216
Alarm
BBBL3/4144_TepusBngk
GBTS
Site No.=13,4144_TepusBngk
Board Type=TMU,
09/17/2013
Board
19:18:26
No.=0, PassNo=255, Su
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
19:18:22
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=0,
19:18:42
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:23:12
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:24:16
No.=0, PassNo=255,
TRX Hardware
2148Critical BBBL3/4144_TepusBngk
Alarm
GBTS
Site No.=13,4144_TepusBngk
Board Type=TRX,
09/17/2013
Board
19:14:37
No.=8, PassNo=255, Su

09/17/2013 09/17/2013
18:25:59 19:06:44
< System operator >
09/17/2013 09/18/2013
18:26:23 01:33:13
< System operator >
09/17/2013 09/17/2013
18:26:32 21:37:30
< System operator >
09/17/2013 09/17/2013
18:26:37 19:06:44
< System operator >
09/17/2013 09/17/2013
18:32:33 19:06:44
< System operator >
09/17/2013 09/17/2013
18:33:12 19:06:44
< System operator >
09/17/2013 09/17/2013
18:35:32 20:03:17
< System operator >
09/17/2013 09/17/2013
18:35:45 23:50:52
< System operator >
09/17/2013 09/17/2013
18:37:04 19:06:44
< System operator >
09/17/2013 09/17/2013
18:40:19 19:06:44
< System operator >
09/17/2013 09/17/2013
18:40:31 19:06:44
< System operator >
09/17/2013 09/18/2013
18:41:27 00:59:18
< System operator >
09/17/2013 09/17/2013
18:45:34 20:44:29
< System operator >
09/17/2013 09/17/2013
18:45:39 20:44:29
< System operator >
09/17/2013 09/17/2013
18:45:57 19:06:44
< System operator >
09/17/2013 09/17/2013
18:46:58 20:03:17
< System operator >
09/17/2013 09/17/2013
18:50:31 20:03:17
< System operator >
09/17/2013 09/17/2013
18:54:42 20:03:17
< System operator >
09/17/2013 09/17/2013
19:00:17 19:06:44
< System operator >
09/17/2013 -19:11:29 09/17/2013 09/17/2013
19:11:32 20:03:17
< System operator >
09/17/2013 09/17/2013
19:11:40 20:03:17
< System operator >
09/17/2013 09/17/2013
19:11:45 21:37:30
< System operator >
09/17/2013 09/17/2013
19:11:45 21:37:30
< System operator >
09/17/2013 09/17/2013
19:11:45 21:37:30
< System operator >
09/17/2013 09/17/2013
19:11:45 20:03:17
< System operator >
09/17/2013 09/17/2013
19:11:50 23:50:52
< System operator >
09/17/2013 09/17/2013
19:11:50 20:03:17
< System operator >
09/17/2013 09/17/2013
19:11:50 20:03:17
< System operator >
09/17/2013 09/18/2013
19:11:50 03:10:45
< System operator >
09/17/2013 09/17/2013
19:11:56 20:03:17
< System operator >
09/17/2013 09/17/2013
19:12:00 20:03:17
< System operator >
09/17/2013 09/17/2013
19:12:00 20:03:17
< System operator >
09/17/2013 09/18/2013
19:12:33 05:12:16
< System operator >
09/17/2013 -19:12:49 09/17/2013 09/17/2013
19:13:01 20:03:17
< System operator >
09/17/2013 09/17/2013
19:13:05 20:03:17
< System operator >
09/17/2013 09/17/2013
19:13:44 20:03:17
< System operator >
09/17/2013 09/17/2013
19:13:44 20:03:17
< System operator >
09/17/2013 09/17/2013
19:14:35 20:03:17
< System operator >
09/17/2013 09/17/2013
19:15:04 20:03:17
< System operator >
09/17/2013 09/17/2013
19:15:43 20:03:17
< System operator >
09/17/2013 09/17/2013
19:15:45 20:03:17
< System operator >
09/17/2013 09/17/2013
19:15:45 20:03:17
< System operator >
09/17/2013 -19:16:09 09/17/2013 09/17/2013
19:16:21 20:03:17
< System operator >
09/17/2013 09/17/2013
19:16:27 20:03:17
< System operator >
09/17/2013 09/17/2013
19:16:27 20:03:17
< System operator >
09/17/2013 09/17/2013
19:16:27 20:03:17
< System operator >
09/17/2013 09/17/2013
19:20:05 20:03:17
< System operator >
09/17/2013 09/17/2013
19:21:29 20:03:17
< System operator >
09/17/2013 09/17/2013
19:22:22 20:03:17
< System operator >
09/17/2013 -19:22:44 09/17/2013 09/17/2013
19:24:14 20:03:17
< System operator >
09/17/2013 09/17/2013
19:24:20 20:03:17
< System operator >
09/17/2013 09/17/2013
19:24:38 20:03:17
< System operator >

Major
Major
Major
Critical
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:24:24
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:24:43
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:25:08
No.=0, PassNo=255, S
GSM Cell out
21801
of Service
BBBL3/4144_TepusBngk
GBTS
Site Index=13,
LABEL=4144_TepusBngk-3,
Cell Index=41,
09/17/2013
Alarm
19:12:55
Cause=Other
CellIndex=41,
causes,
CGI=51
Site
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:27:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:28:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:28:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:28:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:29:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:29:50
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:30:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:22
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:31:57
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:32:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:33:35
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:24:50
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:34:48
No.=0, PassNo=255,
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:48
No.=0, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:46
No.=4, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:45
No.=9, PassNo=255, Su
DC Lowvoltage
2330Alarm BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PMU,
09/17/2013
Board
19:35:14
No.=0, PassNo=255, S
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:46
No.=5, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:52
No.=8, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:43
No.=1, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:12
No.=0, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:14
No.=4, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:16
No.=8, PassNo=255, Su
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:38:22
No.=0, PassNo=255,
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=3,
19:39:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=3,
19:39:03
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=3,
19:39:03
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:39:03
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:39:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:39:13
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:40:11
No.=0, PassNo=255,
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=3,
19:39:22
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:40:29
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:40:54
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:41:07
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:37:37
No.=0, PassNo=255,
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=3,
19:40:30
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:41:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:45:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:46:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:46:47
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:47:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:47:35
No.=0, PassNo=255,
Genset run 2418
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=EAC,
09/17/2013
Board
19:12:10
No.=0, PassNo=255, Su
AC L1 failure
2410
alarm
BBBL3/DA29_Delas
GBTS
Site No.=4, DA29_Delas
Board Type=EAC,
09/17/2013
Board
19:11:31
No.=0, PassNo=255, Sub
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
12:52:08
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:52:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:54:24
No.=0, PassNo=255,

09/17/2013 09/17/2013
19:24:41 20:03:17
< System operator >
09/17/2013 09/17/2013
19:24:48 20:03:17
< System operator >
09/17/2013 09/17/2013
19:25:10 20:03:17
< System operator >
09/17/2013 09/17/2013
19:26:10 20:03:17
< System operator >
09/17/2013 09/17/2013
19:27:36 20:03:17
< System operator >
09/17/2013 09/17/2013
19:28:22 20:03:17
< System operator >
09/17/2013 09/17/2013
19:28:34 20:03:17
< System operator >
09/17/2013 09/17/2013
19:29:00 20:03:17
< System operator >
09/17/2013 09/17/2013
19:29:08 20:03:17
< System operator >
09/17/2013 09/17/2013
19:29:52 20:03:17
< System operator >
09/17/2013 09/17/2013
19:30:56 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:12 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:20 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:24 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:44 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:54 20:03:17
< System operator >
09/17/2013 09/17/2013
19:31:58 20:03:17
< System operator >
09/17/2013 09/17/2013
19:32:48 20:03:17
< System operator >
09/17/2013 09/17/2013
19:33:36 20:03:17
< System operator >
09/17/2013 09/17/2013
19:34:45 20:03:17
< System operator >
09/17/2013 09/17/2013
19:35:01 20:03:17
< System operator >
09/17/2013 09/17/2013
19:35:58 20:03:17
< System operator >
09/17/2013 09/17/2013
19:35:58 20:03:17
< System operator >
09/17/2013 09/17/2013
19:35:58 20:03:17
< System operator >
09/17/2013 09/17/2013
19:35:58 20:03:17
< System operator >
09/17/2013 09/17/2013
19:36:01 20:03:17
< System operator >
09/17/2013 09/17/2013
19:36:02 20:03:17
< System operator >
09/17/2013 09/17/2013
19:36:14 20:03:17
< System operator >
09/17/2013 09/17/2013
19:37:23 20:03:17
< System operator >
09/17/2013 09/17/2013
19:37:24 20:03:17
< System operator >
09/17/2013 09/17/2013
19:37:27 20:03:17
< System operator >
09/17/2013 09/17/2013
19:38:26 20:03:17
< System operator >
09/17/2013 09/17/2013
19:39:04 20:44:29
< System operator >
09/17/2013 09/17/2013
19:39:04 20:03:17
< System operator >
09/17/2013 09/17/2013
19:39:04 20:03:17
< System operator >
09/17/2013 09/17/2013
19:39:05 20:03:17
< System operator >
09/17/2013 09/17/2013
19:39:08 20:03:17
< System operator >
09/17/2013 09/17/2013
19:39:15 20:03:17
< System operator >
09/17/2013 09/17/2013
19:40:13 20:03:17
< System operator >
09/17/2013 09/17/2013
19:40:28 20:03:17
< System operator >
09/17/2013 09/17/2013
19:40:31 20:03:17
< System operator >
09/17/2013 09/17/2013
19:40:56 20:03:17
< System operator >
09/17/2013 09/17/2013
19:41:09 20:03:17
< System operator >
09/17/2013 09/17/2013
19:41:34 20:03:17
< System operator >
09/17/2013 09/17/2013
19:42:03 20:03:17
< System operator >
09/17/2013 09/17/2013
19:43:29 20:03:17
< System operator >
09/17/2013 09/17/2013
19:45:32 20:03:17
< System operator >
09/17/2013 09/17/2013
19:46:27 20:03:17
< System operator >
09/17/2013 09/17/2013
19:46:49 20:03:17
< System operator >
09/17/2013 09/17/2013
19:47:22 20:03:17
< System operator >
09/17/2013 09/17/2013
19:47:37 20:03:17
< System operator >
09/17/2013 09/18/2013
19:48:09 05:12:16
< System operator >
09/17/2013 09/18/2013
19:48:14 05:12:16
< System operator >
09/17/2013 09/17/2013
19:51:38 20:03:17
< System operator >
09/17/2013 09/17/2013
19:54:00 20:03:17
< System operator >
09/17/2013 09/17/2013
19:54:26 20:03:17
< System operator >

Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Correlative Critical
Alarm
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Correlative Critical
Alarm
Major
Major
Major
Major
Major
Major
Correlative Critical
Alarm
Critical
Correlative Critical
Alarm

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:54:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:54:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:55:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:55:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:56:00
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
19:56:33
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:56:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
19:57:18
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:54:02
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:57:58
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:58:02
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:58:15
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:58:19
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:58:25
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
19:58:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
19:58:13
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=3,
19:42:59
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/DA09_PangkalBuluh
GBTS
Site Index=55,
DA09_PangkalBuluh
BSC Subrack
09/17/2013
No.=3,
19:40:50
BSC Slot No.=18, E1 No.=
CDU Communication
2280
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=CDU,
09/17/2013
Board
19:38:56
No.=1, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:38:16
No.=5, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:38:09
No.=8, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:38:06
No.=4, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:38:05
No.=0, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:38:05
No.=9, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:40
No.=9, PassNo=255, Su
PSU Safeguard
2436Alarm BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PSU,
09/17/2013
Board
19:37:28
No.=2, PassNo=255, Su
PSU Safeguard
2436Alarm BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PSU,
09/17/2013
Board
19:37:28
No.=1, PassNo=255, Su
PSU Safeguard
2436Alarm BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PSU,
09/17/2013
Board
19:37:28
No.=0, PassNo=255, Su
TRX Voltage
2128
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:09
No.=1, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:37:08
No.=1, PassNo=255, Su
DC Lowvoltage
2330Alarm BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=PMU,
09/17/2013
Board
19:36:42
No.=0, PassNo=255, S
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:36:13
No.=4, PassNo=255, Su
CDU Communication
2280
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=CDU,
09/17/2013
Board
19:35:39
No.=4, PassNo=255, Su
CDU Communication
2280
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=CDU,
09/17/2013
Board
19:35:39
No.=2, PassNo=255, Su
CDU Communication
2280
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=CDU,
09/17/2013
Board
19:35:39
No.=0, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:38
No.=8, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:35:04
No.=0, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:25
No.=10, PassNo=255, S
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:24
No.=7, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:24
No.=3, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:07
No.=11, PassNo=255, S
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:07
No.=6, PassNo=255, Su
TRX Hardware
2148Critical BBBL3/DA09_PangkalBuluh
Alarm
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
19:34:07
No.=2, PassNo=255, Su
AC L3 failure
2414
alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
19:11:31
No.=0, PassNo=255, Su
AC L2 failure
2412
alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
19:11:31
No.=0, PassNo=255, Su
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=3,
Slot No.=18,
Slot No.=18,
09/17/2013
Subrack
Subsystem
No=3,
19:13:58
Subsystem
No.=0, E1/T1
No.=0
Port No
OML Fault 21807
BBBL3/4696_Payung
GBTS
Site Index=56,
4696_Payung
BSC Subrack
09/17/2013
No.=3,
19:15:44
BSC Slot No.=18, E1 No.=
AC L1 failure
2410
alarm
BBBL3/4696_Payung
GBTS
Site No.=56,4696_Payung
Board Type=EAC,
09/17/2013
Board
19:11:30
No.=0, PassNo=255, Su
Rectifier module
2406 fault BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:05
No.=0, PassNo=255, Su
Rectifier DC2404
low or hight
BBBL3/DA09_PangkalBuluh
voltage GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=EAC,
09/17/2013
Board
20:01:05
No.=0, PassNo=255, Su
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:01:16
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:01:25
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:01:35
No.=0, PassNo=255,
GSM Cell out
21801
of Service
BBBL3/4696_Payung
GBTS
Site Index=56,
LABEL=4696_Payung-2,
Cell Index=181,
09/17/2013
Alarm
19:15:44
CellIndex=181,
Cause=Other causes,
CGI=5101
Si
GSM Cell out
21801
of Service
BBBL3/DA09_PangkalBuluh
GBTS
Site Index=55,
LABEL=4109_PngklBlh-4,
Cell Index=177,
09/17/2013
Alarm
19:38:40
Cause=Other
CellIndex=177,
causes,
CGI=510
Si
GSM Cell out
21801
of Service
BBBL3/DA09_PangkalBuluh
GBTS
Site Index=55,
LABEL=4109_PngklBlh-5,
Cell Index=178,
09/17/2013
Alarm
19:39:50
Cause=Other
CellIndex=178,
causes,
CGI=510
Si

09/17/2013 09/17/2013
19:54:33 20:03:17
< System operator >
09/17/2013 09/17/2013
19:54:40 20:03:17
< System operator >
09/17/2013 09/17/2013
19:55:38 20:03:17
< System operator >
09/17/2013 09/17/2013
19:55:46 20:03:17
< System operator >
09/17/2013 09/17/2013
19:56:02 20:03:17
< System operator >
09/17/2013 09/17/2013
19:56:34 21:37:30
< System operator >
09/17/2013 09/17/2013
19:56:39 20:03:17
< System operator >
09/17/2013 09/17/2013
19:57:20 20:44:29
< System operator >
09/17/2013 09/17/2013
19:57:38 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:01 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:05 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:16 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:22 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:34 20:03:17
< System operator >
09/17/2013 09/17/2013
19:58:55 20:44:29
< System operator >
09/17/2013 09/17/2013
19:59:07 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:32 20:44:29
< System operator >
09/17/2013 -20:00:35 09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/17/2013
20:00:35 20:03:17
< System operator >
09/17/2013 09/18/2013
20:00:35 05:12:16
< System operator >
09/17/2013 09/18/2013
20:00:35 05:12:16
< System operator >
09/17/2013 09/17/2013
20:00:59 20:03:17
< System operator >
09/17/2013 09/17/2013
20:01:03 20:03:17
< System operator >
09/17/2013 09/18/2013
20:01:03 05:12:16
< System operator >
09/17/2013 09/17/2013
20:01:10 20:03:17
< System operator >
09/17/2013 09/17/2013
20:01:11 20:03:17
< System operator >
09/17/2013 09/17/2013
20:01:19 20:03:17
< System operator >
09/17/2013 09/17/2013
20:01:27 20:03:17
< System operator >
09/17/2013 09/17/2013
20:01:53 20:03:17
< System operator >
09/17/2013 09/17/2013
20:03:39 20:44:29
< System operator >
09/17/2013 -20:03:40 09/17/2013 -20:03:45 -

Critical
Major
Major
Correlative Critical
Alarm
Correlative Critical
Alarm
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Minor
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

GSM Cell out


21801
of Service
BBBL3/DA09_PangkalBuluh
GBTS
Site Index=55,
LABEL=4109_PngklBlh-6,
Cell Index=179,
09/17/2013
Alarm
19:37:10
Cause=Other
CellIndex=179,
causes,
CGI=510
Si
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:01:55
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:04:08
No.=0, PassNo=255,
GSM Cell out
21801
of Service
BBBL3/4696_Payung
GBTS
Site Index=56,
LABEL=4696_Payung-3,
Cell Index=182,
09/17/2013
Alarm
19:15:44
CellIndex=182,
Cause=Other causes,
CGI=5101
Si
GSM Cell out
21801
of Service
BBBL3/4696_Payung
GBTS
Site Index=56,
LABEL=4696_Payung-1,
Cell Index=180,
09/17/2013
Alarm
19:15:44
CellIndex=180,
Cause=Other causes,
CGI=5101
Si
MSP Failure65039
BBBL3/2273579_RanggungPayung
GBTS
Cabinet No.=0,
2273579_RanggungPayung
Subrack
09/17/2013
No.=40, Slot
19:11:46
No.=0, Port No.=3, Board
AC L3 Failure
65037
BBBL3/2273579_RanggungPayung
GBTS
Cabinet No.=0,
2273579_RanggungPayung
Subrack
09/17/2013
No.=40, Slot
19:11:46
No.=0, Port No.=2, Board
AC L2 Failure
65035
BBBL3/2273579_RanggungPayung
GBTS
Cabinet No.=0,
2273579_RanggungPayung
Subrack
09/17/2013
No.=40, Slot
19:11:46
No.=0, Port No.=1, Board
AC L1 Failure
65033
BBBL3/2273579_RanggungPayung
GBTS
Cabinet No.=0,
2273579_RanggungPayung
Subrack
09/17/2013
No.=40, Slot
19:11:46
No.=0, Port No.=0, Board
MSP Failure65039
BBBL3/2273580_GudangSimpangRimba
GBTS
Cabinet No.=0,
2273580_GudangSimpangRimba
Subrack
09/17/2013
No.=40, Slot
19:11:47
No.=0, Port No.=3, Board
AC L3 Failure
65037
BBBL3/2273580_GudangSimpangRimba
GBTS
Cabinet No.=0,
2273580_GudangSimpangRimba
Subrack
09/17/2013
No.=40, Slot
19:11:47
No.=0, Port No.=2, Board
AC L2 Failure
65035
BBBL3/2273580_GudangSimpangRimba
GBTS
Cabinet No.=0,
2273580_GudangSimpangRimba
Subrack
09/17/2013
No.=40, Slot
19:11:47
No.=0, Port No.=1, Board
AC L1 Failure
65033
BBBL3/2273580_GudangSimpangRimba
GBTS
Cabinet No.=0,
2273580_GudangSimpangRimba
Subrack
09/17/2013
No.=40, Slot
19:11:47
No.=0, Port No.=0, Board
Genset run 2418
BBBL3/DA28_BangkaKota
GBTS
Site No.=54,DA28_BangkaKota
Board Type=EAC,
09/17/2013
Board
19:11:52
No.=0, PassNo=255, Su
TRX Communication
2204
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
20:03:41
No.=3, PassNo=255, Su
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:04:11
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:05:30
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:05:33
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:05:53
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:06:34
No.=0, PassNo=255,
TRX Communication
2204
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
20:05:45
No.=6, PassNo=255, Su
TRX Communication
2204
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
20:05:29
No.=7, PassNo=255, Su
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:06:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:08:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:08:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:08:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:08:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:09:01
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:09:27
No.=0, PassNo=255,
TRX Communication
2204
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
20:08:15
No.=10, PassNo=255, S
TRX Communication
2204
Alarm
BBBL3/DA09_PangkalBuluh
GBTS
Site No.=55,DA09_PangkalBuluh
Board Type=TRX,
09/17/2013
Board
20:08:15
No.=11, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:09:35
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:10:03
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:10:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:11:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:11:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:11:33
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:11:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:12:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
20:21:45
No.=0, PassNo=255,
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=0,
Slot No.=20,
Slot No.=20,
09/17/2013
Subrack
Subsystem
No=0,
20:08:24
Subsystem
No.=0, E1/T1
No.=0
Port No
Cabinet Air 25656
Inlet Temperature
BBBL3/227A895_BaharToboali_CDC
Unacceptable
GBTS
Cabinet No.=1,
227A895_BaharToboali_CDC
Subrack
09/17/2013
No.=11, Slot
14:10:44
No.=0, Board Type=FMU
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
20:30:36
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
20:30:44
Subsystem
No.=0, E1/T1
No.=0
Port No
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
16:16:02
No.=3, PassNo=255, Su
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
20:38:24
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:36:13
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:39:15
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:39:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:40:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:40:38
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:40:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:40:58
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:41:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:41:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:41:44
No.=0, PassNo=255,

09/17/2013 -20:03:45 09/17/2013 09/17/2013


20:03:57 20:44:29
< System operator >
09/17/2013 09/17/2013
20:04:09 20:44:29
< System operator >
09/17/2013 09/17/2013
20:04:09 20:44:29
< System operator >
09/17/2013 09/17/2013
20:04:09 20:44:29
< System operator >
09/17/2013 09/18/2013
20:04:20 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:20 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:20 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:20 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:22 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:22 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:22 05:12:16
< System operator >
09/17/2013 09/18/2013
20:04:22 05:12:16
< System operator >
09/17/2013 09/17/2013
20:04:51 20:44:29
< System operator >
09/17/2013 09/17/2013
20:04:53 20:44:29
< System operator >
09/17/2013 09/17/2013
20:05:25 20:44:29
< System operator >
09/17/2013 09/17/2013
20:05:31 20:44:29
< System operator >
09/17/2013 09/17/2013
20:05:51 20:44:29
< System operator >
09/17/2013 09/17/2013
20:06:13 20:44:29
< System operator >
09/17/2013 09/17/2013
20:06:35 20:44:29
< System operator >
09/17/2013 -20:06:42 09/17/2013 09/17/2013
20:06:42 20:44:29
< System operator >
09/17/2013 09/17/2013
20:06:49 20:44:29
< System operator >
09/17/2013 09/17/2013
20:08:23 20:44:29
< System operator >
09/17/2013 09/17/2013
20:08:33 20:44:29
< System operator >
09/17/2013 09/17/2013
20:08:42 20:44:29
< System operator >
09/17/2013 09/17/2013
20:08:45 20:44:29
< System operator >
09/17/2013 09/17/2013
20:09:06 20:44:29
< System operator >
09/17/2013 09/17/2013
20:09:31 20:44:29
< System operator >
09/17/2013 -20:09:32 09/17/2013 09/17/2013
20:09:32 20:44:29
< System operator >
09/17/2013 09/17/2013
20:09:37 20:44:29
< System operator >
09/17/2013 09/17/2013
20:10:08 20:44:29
< System operator >
09/17/2013 09/17/2013
20:10:33 20:44:29
< System operator >
09/17/2013 09/17/2013
20:11:11 20:44:29
< System operator >
09/17/2013 09/17/2013
20:11:19 20:44:29
< System operator >
09/17/2013 09/17/2013
20:11:35 20:44:29
< System operator >
09/17/2013 09/17/2013
20:11:55 20:44:29
< System operator >
09/17/2013 09/17/2013
20:12:42 20:44:29
< System operator >
09/17/2013 09/17/2013
20:21:47 23:50:52
< System operator >
09/17/2013 -20:23:25 09/17/2013 -20:24:01 09/17/2013 09/17/2013
20:31:13 20:44:29
< System operator >
09/17/2013 09/17/2013
20:31:30 21:37:30
< System operator >
09/17/2013 09/17/2013
20:31:57 20:44:29
< System operator >
09/17/2013 09/18/2013
20:38:44 00:59:18
< System operator >
09/17/2013 09/17/2013
20:39:04 20:44:29
< System operator >
09/17/2013 09/17/2013
20:39:16 20:44:29
< System operator >
09/17/2013 09/17/2013
20:39:42 20:44:29
< System operator >
09/17/2013 09/17/2013
20:40:28 20:44:29
< System operator >
09/17/2013 09/17/2013
20:40:42 20:44:29
< System operator >
09/17/2013 09/17/2013
20:40:48 20:44:29
< System operator >
09/17/2013 09/17/2013
20:41:01 20:44:29
< System operator >
09/17/2013 09/17/2013
20:41:04 20:44:29
< System operator >
09/17/2013 09/17/2013
20:41:30 20:44:29
< System operator >
09/17/2013 09/17/2013
20:41:48 20:44:29
< System operator >

Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Warning
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Warning
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:41:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:42:12
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
20:41:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
20:41:15
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:42:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:42:54
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:43:02
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:39:55
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:43:21
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:44:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:44:49
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:45:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:45:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:45:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:46:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:46:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:46:55
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:47:32
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:48:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:49:23
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
20:49:27
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:49:34
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
20:46:28
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
20:50:17
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:50:43
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
20:51:06
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:51:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:51:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:51:56
No.=0, PassNo=255,
Clock Reference
4708 Abnormal
BBBL3/227A810_Terap
Alarm GBTS
Site No.=42,227A810_Terap
Board Type=DTMU,
09/17/2013Board
19:17:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:52:17
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
20:52:32
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:52:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:53:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:53:52
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:54:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:54:33
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:55:17
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:56:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:56:43
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:57:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:58:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:58:09
No.=0, PassNo=255,
Clock Reference
2208 abnormal
BBBL3/EH01_TanjgLabu
Alarm GBTS
Site No.=41,EH01_TanjgLabu
Board Type=TMU,
09/17/2013
Board
19:11:49
No.=0, PassNo=255, Su
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:58:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
20:59:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:00:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:00:18
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:01:28
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:01:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:01:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:02:26
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:02:40
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:02:38
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:02:44
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:02:48
No.=0, PassNo=255,

09/17/2013 09/17/2013
20:41:56 20:44:29
< System operator >
09/17/2013 09/17/2013
20:42:15 20:44:29
< System operator >
09/17/2013 09/18/2013
20:42:18 00:59:18
< System operator >
09/17/2013 09/18/2013
20:42:26 00:59:18
< System operator >
09/17/2013 09/17/2013
20:42:33 20:44:29
< System operator >
09/17/2013 09/17/2013
20:42:56 20:44:29
< System operator >
09/17/2013 09/17/2013
20:43:04 20:44:29
< System operator >
09/17/2013 09/17/2013
20:43:17 20:44:29
< System operator >
09/17/2013 09/17/2013
20:43:22 21:37:30
< System operator >
09/17/2013 09/17/2013
20:44:31 21:37:30
< System operator >
09/17/2013 09/17/2013
20:44:50 21:37:30
< System operator >
09/17/2013 09/17/2013
20:45:05 21:37:30
< System operator >
09/17/2013 09/17/2013
20:45:19 21:37:30
< System operator >
09/17/2013 09/17/2013
20:45:38 21:37:30
< System operator >
09/17/2013 09/17/2013
20:46:28 21:37:30
< System operator >
09/17/2013 09/17/2013
20:46:39 21:37:30
< System operator >
09/17/2013 09/17/2013
20:47:01 21:37:30
< System operator >
09/17/2013 09/17/2013
20:47:34 21:37:30
< System operator >
09/17/2013 09/17/2013
20:48:47 21:37:30
< System operator >
09/17/2013 09/17/2013
20:49:24 21:37:30
< System operator >
09/17/2013 09/17/2013
20:49:29 21:37:30
< System operator >
09/17/2013 09/17/2013
20:49:41 21:37:30
< System operator >
09/17/2013 09/17/2013
20:50:12 21:37:30
< System operator >
09/17/2013 09/17/2013
20:50:19 21:37:30
< System operator >
09/17/2013 09/17/2013
20:50:45 21:37:30
< System operator >
09/17/2013 09/17/2013
20:51:10 21:37:30
< System operator >
09/17/2013 09/17/2013
20:51:24 21:37:30
< System operator >
09/17/2013 09/17/2013
20:51:43 21:37:30
< System operator >
09/17/2013 09/17/2013
20:51:59 21:37:30
< System operator >
09/17/2013 09/18/2013
20:52:04 04:05:55
< System operator >
09/17/2013 09/17/2013
20:52:23 21:37:30
< System operator >
09/17/2013 09/17/2013
20:52:34 21:37:30
< System operator >
09/17/2013 09/17/2013
20:52:46 21:37:30
< System operator >
09/17/2013 09/17/2013
20:53:46 21:37:30
< System operator >
09/17/2013 09/17/2013
20:53:57 21:37:30
< System operator >
09/17/2013 09/17/2013
20:54:27 21:37:30
< System operator >
09/17/2013 09/17/2013
20:54:38 21:37:30
< System operator >
09/17/2013 09/17/2013
20:55:19 21:37:30
< System operator >
09/17/2013 09/17/2013
20:56:18 21:37:30
< System operator >
09/17/2013 09/17/2013
20:56:45 21:37:30
< System operator >
09/17/2013 09/17/2013
20:57:19 21:37:30
< System operator >
09/17/2013 09/17/2013
20:58:08 21:37:30
< System operator >
09/17/2013 09/17/2013
20:58:11 21:37:30
< System operator >
09/17/2013 09/18/2013
20:58:51 02:25:17
< System operator >
09/17/2013 09/17/2013
20:58:56 21:37:30
< System operator >
09/17/2013 09/17/2013
20:59:31 21:37:30
< System operator >
09/17/2013 09/17/2013
21:00:07 21:37:30
< System operator >
09/17/2013 09/17/2013
21:00:19 21:37:30
< System operator >
09/17/2013 09/17/2013
21:01:30 21:37:30
< System operator >
09/17/2013 09/17/2013
21:01:34 21:37:30
< System operator >
09/17/2013 09/17/2013
21:01:44 21:37:30
< System operator >
09/17/2013 09/17/2013
21:02:28 21:37:30
< System operator >
09/17/2013 09/17/2013
21:02:42 21:37:30
< System operator >
09/17/2013 09/17/2013
21:02:42 21:37:30
< System operator >
09/17/2013 09/17/2013
21:02:46 21:37:30
< System operator >
09/17/2013 09/17/2013
21:02:56 21:37:30
< System operator >

Major
Major
Major
Major
Major
Major
Minor
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:03:06
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:03:16
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:03:25
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:04:34
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:04:48
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:05:16
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
21:04:33
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:07:10
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
21:08:29
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:03:28
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:09:08
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:09:32
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:11:24
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:12:47
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:13:07
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:14:29
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:14:41
No.=0, PassNo=255,
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
21:16:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
21:16:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
21:16:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
21:16:27
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
25802
Alarm Indication
BBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
21:16:29
No.=6, Port No.=1, Site N
E1/T1 Remote
25802
Alarm Indication
BBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
21:16:29
No.=6, Port No.=0, Site N
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:18:19
No.=0, PassNo=255,
Over Temperature
6412 Alarm
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
13:37:13
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:19:43
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:20:19
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:20:41
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:21:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:23:23
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:23:29
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:23:42
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:23:48
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:09:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:25:27
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:26:05
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:26:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:26:22
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:26:30
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:26:39
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:28:04
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:30:22
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:31:54
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:32:53
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:33:57
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:39:47
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:44:32
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:44:43
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:44:47
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:45:01
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
21:45:05
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:46:20
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:48:51
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:50:04
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:51:02
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
21:51:28
No.=0, PassNo=255, S

09/17/2013 09/17/2013
21:03:15 21:37:30
< System operator >
09/17/2013 09/17/2013
21:03:24 21:37:30
< System operator >
09/17/2013 09/17/2013
21:03:28 21:37:30
< System operator >
09/17/2013 09/17/2013
21:04:36 21:37:30
< System operator >
09/17/2013 09/17/2013
21:04:49 21:37:30
< System operator >
09/17/2013 09/17/2013
21:05:18 21:37:30
< System operator >
09/17/2013 09/18/2013
21:05:31 02:25:17
< System operator >
09/17/2013 09/17/2013
21:07:12 21:37:30
< System operator >
09/17/2013 09/18/2013
21:08:41 02:25:17
< System operator >
09/17/2013 09/17/2013
21:09:07 21:37:30
< System operator >
09/17/2013 09/17/2013
21:09:29 21:37:30
< System operator >
09/17/2013 09/17/2013
21:09:35 21:37:30
< System operator >
09/17/2013 09/17/2013
21:11:26 21:37:30
< System operator >
09/17/2013 09/17/2013
21:12:49 21:37:30
< System operator >
09/17/2013 09/17/2013
21:13:09 21:37:30
< System operator >
09/17/2013 09/17/2013
21:14:31 21:37:30
< System operator >
09/17/2013 09/17/2013
21:14:43 21:37:30
< System operator >
09/17/2013 09/17/2013
21:16:53 22:29:26
< System operator >
09/17/2013 09/18/2013
21:16:53 00:59:18
< System operator >
09/17/2013 09/18/2013
21:16:53 00:59:18
< System operator >
09/17/2013 09/18/2013
21:16:53 00:59:18
< System operator >
09/17/2013 09/18/2013
21:17:05 00:59:18
< System operator >
09/17/2013 09/18/2013
21:17:05 00:59:18
< System operator >
09/17/2013 09/17/2013
21:18:21 21:37:30
< System operator >
09/17/2013 -21:19:27 09/17/2013 09/17/2013
21:19:45 22:29:26
< System operator >
09/17/2013 09/17/2013
21:20:21 21:37:30
< System operator >
09/17/2013 09/17/2013
21:20:43 21:37:30
< System operator >
09/17/2013 09/17/2013
21:21:32 21:37:30
< System operator >
09/17/2013 09/17/2013
21:23:25 21:37:30
< System operator >
09/17/2013 09/17/2013
21:23:32 21:37:30
< System operator >
09/17/2013 09/17/2013
21:23:43 21:37:30
< System operator >
09/17/2013 09/17/2013
21:23:50 21:37:30
< System operator >
09/17/2013 09/17/2013
21:25:28 21:37:30
< System operator >
09/17/2013 09/17/2013
21:25:30 21:37:30
< System operator >
09/17/2013 09/17/2013
21:26:06 21:37:30
< System operator >
09/17/2013 09/17/2013
21:26:14 21:37:30
< System operator >
09/17/2013 09/17/2013
21:26:24 22:29:26
< System operator >
09/17/2013 09/17/2013
21:26:36 21:37:30
< System operator >
09/17/2013 09/17/2013
21:28:02 21:37:30
< System operator >
09/17/2013 09/17/2013
21:30:20 21:37:30
< System operator >
09/17/2013 09/17/2013
21:31:45 21:37:30
< System operator >
09/17/2013 09/17/2013
21:32:51 21:37:30
< System operator >
09/17/2013 09/17/2013
21:33:17 21:37:30
< System operator >
09/17/2013 09/17/2013
21:39:46 22:29:26
< System operator >
09/17/2013 09/17/2013
21:44:22 22:29:26
< System operator >
09/17/2013 09/17/2013
21:44:37 22:29:26
< System operator >
09/17/2013 09/17/2013
21:44:46 22:29:26
< System operator >
09/17/2013 09/17/2013
21:44:58 22:29:26
< System operator >
09/17/2013 09/17/2013
21:45:02 22:29:26
< System operator >
09/17/2013 09/17/2013
21:45:08 22:29:26
< System operator >
09/17/2013 09/17/2013
21:46:21 22:29:26
< System operator >
09/17/2013 09/17/2013
21:48:54 22:29:26
< System operator >
09/17/2013 09/17/2013
21:50:05 22:29:26
< System operator >
09/17/2013 09/17/2013
21:51:03 22:29:26
< System operator >
09/17/2013 09/17/2013
21:51:30 22:29:26
< System operator >

Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Critical
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major
Major

AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:53:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:56:06
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
21:59:25
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A810_Terap
GBTS
Site No.=42,227A810_Terap
Board Type=DEMU,
09/17/2013Board
22:08:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
19:51:40
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:07:37
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:10:11
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:11:08
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:11:18
No.=0, PassNo=255,
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
22:11:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
22:11:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
22:11:51
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=7,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=7,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=7,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=1,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=1,
22:11:52
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
22:11:51
Subsystem
No.=0, E1/T1
No.=0
Port No
Ater OML Faulty
20261
BBBL3
BSC6900 GSM
Link Index Number=1
BBBL3
09/17/2013 22:12:05
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:13:06
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:13:36
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
22:17:49
No.=0, PassNo=255, S
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:09:28
No.=0, PassNo=255,
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:56:57
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:17:58
No.=0, PassNo=255,
Shelter Door
65062
Open
BBBL3/DA25_NibKoba
GBTS
Cabinet
[Swap] No.=0,
DA25_NibKoba
Subrack
09/17/2013
No.=40,
[Swap]
Slot
21:32:58
No.=0, Port No.=15, Boa
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:33:39
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:46:43
No.=0, PassNo=255,
Shelter Door
65062
Open
BBBL3/DA25_NibKoba
GBTS
Cabinet
[Swap] No.=0,
DA25_NibKoba
Subrack
09/17/2013
No.=40,
[Swap]
Slot
22:38:28
No.=0, Port No.=15, Boa
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:47:16
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:50:11
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:50:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:53:12
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
22:56:20
No.=0, PassNo=255, S
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
22:57:28
No.=0, PassNo=255, S
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:14:00
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
22:57:10
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:11:45
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:11:53
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:15:25
No.=0, PassNo=255,
PMU Communication
2334
Alarm
BBBL3/D670_Bedegung
GBTS
Site No.=24,D670_Bedegung
Board Type=PMU,
09/17/2013
Board
23:16:07
No.=0, PassNo=255, S
Over Temperature
2376 Alarm
BBBL3/D648_AirGergas[HUB]
GBTS
Site No.=8, D648_AirGergas[HUB]
Board Type=EAC,
09/17/2013
Board
19:51:54
No.=0, PassNo=255, Sub
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:00:56
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:15:44
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:19:21
No.=0, PassNo=255,
E1/T1 Alarm
25801
IndicationBBBL3/DA14_Tukak_Reloc
Signal
GBTS
Cabinet No.=0,
DA14_Tukak_Reloc
Subrack
09/17/2013
No.=0, Slot
23:21:10
No.=6, Port No.=1, Site N
E1/T1 Alarm
25801
IndicationBBBL3/DA14_Tukak_Reloc
Signal
GBTS
Cabinet No.=0,
DA14_Tukak_Reloc
Subrack
09/17/2013
No.=0, Slot
23:21:10
No.=6, Port No.=0, Site N
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:20:36
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:22:08
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:22:26
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:26:44
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:18:23
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:28:30
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:29:42
No.=0, PassNo=255,

09/17/2013 09/17/2013
21:53:08 22:29:26
< System operator >
09/17/2013 09/17/2013
21:56:08 22:29:26
< System operator >
09/17/2013 09/17/2013
21:59:29 22:29:26
< System operator >
09/17/2013 09/18/2013
22:08:17 00:59:18
< System operator >
09/17/2013 09/17/2013
22:09:12 22:29:26
< System operator >
09/17/2013 09/17/2013
22:10:09 22:29:26
< System operator >
09/17/2013 09/17/2013
22:10:38 22:29:26
< System operator >
09/17/2013 09/17/2013
22:11:12 22:29:26
< System operator >
09/17/2013 09/17/2013
22:12:50 22:29:26
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:52 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:53 23:14:34
< System operator >
09/17/2013 09/17/2013
22:12:53 23:14:34
< System operator >
09/17/2013 09/18/2013
22:12:58 02:25:17
< System operator >
09/17/2013 09/18/2013
22:13:07 02:25:17
< System operator >
09/17/2013 09/17/2013
22:13:23 22:29:26
< System operator >
09/17/2013 09/17/2013
22:13:46 22:29:26
< System operator >
09/17/2013 09/17/2013
22:17:51 23:14:34
< System operator >
09/17/2013 09/17/2013
22:17:54 22:29:26
< System operator >
09/17/2013 09/17/2013
22:22:53 22:29:26
< System operator >
09/17/2013 09/17/2013
22:33:38 23:14:34
< System operator >
09/17/2013 09/17/2013
22:37:42 23:14:34
< System operator >
09/17/2013 09/17/2013
22:46:41 23:14:34
< System operator >
09/17/2013 09/17/2013
22:46:55 23:14:34
< System operator >
09/17/2013 09/17/2013
22:49:10 23:50:52
< System operator >
09/17/2013 09/17/2013
22:49:49 23:14:34
< System operator >
09/17/2013 09/17/2013
22:50:15 23:14:34
< System operator >
09/17/2013 09/17/2013
22:52:19 23:14:34
< System operator >
09/17/2013 09/17/2013
22:53:29 23:14:34
< System operator >
09/17/2013 09/17/2013
22:56:23 23:14:34
< System operator >
09/17/2013 09/17/2013
22:57:30 23:50:52
< System operator >
09/17/2013 09/17/2013
23:00:51 23:14:34
< System operator >
09/17/2013 09/17/2013
23:11:03 23:14:34
< System operator >
09/17/2013 09/17/2013
23:11:51 23:14:34
< System operator >
09/17/2013 09/17/2013
23:15:11 23:50:52
< System operator >
09/17/2013 09/17/2013
23:15:39 23:50:52
< System operator >
09/17/2013 09/18/2013
23:16:09 00:59:18
< System operator >
09/17/2013 09/17/2013
23:16:45 23:50:52
< System operator >
09/17/2013 09/17/2013
23:18:21 23:50:52
< System operator >
09/17/2013 09/17/2013
23:19:11 23:50:52
< System operator >
09/17/2013 09/17/2013
23:20:14 23:50:52
< System operator >
09/17/2013 -23:21:27 09/17/2013 -23:21:27 09/17/2013 09/17/2013
23:22:04 23:50:52
< System operator >
09/17/2013 09/17/2013
23:22:24 23:50:52
< System operator >
09/17/2013 09/17/2013
23:26:32 23:50:52
< System operator >
09/17/2013 09/17/2013
23:28:02 23:50:52
< System operator >
09/17/2013 09/17/2013
23:28:29 23:50:52
< System operator >
09/17/2013 09/17/2013
23:28:54 23:50:52
< System operator >
09/17/2013 09/17/2013
23:29:44 23:50:52
< System operator >

Major
Major
Minor
Major
Major
Major
Major
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Major
Major
Minor
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Minor
Minor
Major
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Warning
Warning
Warning
Warning
Warning
Minor

AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:29:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:28:10
No.=0, PassNo=255,
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
23:29:00
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:30:16
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:32:15
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:32:37
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:32:57
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
23:33:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
23:33:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
23:33:34
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:35:02
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:35:09
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:30:46
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:36:35
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
23:40:10
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:40:31
No.=0, PassNo=255,
AC L1 Failure
6446
BBBL3/227A809_Pergam
GBTS
Site No.=37,227A809_Pergam
Board Type=DEMU,
09/17/2013Board
23:40:41
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
23:40:32
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=16,
Slot No.=16,
09/17/2013
Subrack
Subsystem
No=0,
23:40:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=22,
Slot No.=22,
09/17/2013
Subrack
Subsystem
No=0,
23:42:15
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
25801
IndicationBBBL3/227B769L2_LubukBesar3
Signal
GBTS
Cabinet No.=0,
227B769L2_LubukBesar3
Subrack
09/17/2013
No.=0, Slot
23:42:25
No.=6, Port No.=0, Site N
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
23:33:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
23:34:33
Subsystem
No.=0, E1/T1
No.=0
Port No
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:43:25
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
23:43:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=21,
Slot No.=21,
09/17/2013
Subrack
Subsystem
No=1,
23:49:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
23:49:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
23:49:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Alarm
21204
IndicationBBBL3
Signal
BSC6900 GSM
Subrack No.=1,
Slot No.=19,
Slot No.=19,
09/17/2013
Subrack
Subsystem
No=1,
23:49:45
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
25802
Alarm Indication
BBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
23:49:46
No.=6, Port No.=0, Site N
E1/T1 Remote
25802
Alarm Indication
BBBL3/4145_Tanjungsangkar_CDC
Signal
GBTS
Cabinet No.=0,
4145_Tanjungsangkar_CDC
Subrack
09/17/2013
No.=0, Slot
23:49:46
No.=6, Port No.=1, Site N
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:46:10
No.=0, PassNo=255,
AC L2 Failure
6448
Alarm BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:57:47
No.=0, PassNo=255,
E1/T1 Excessive
25806Bit Error
BBBL3/DA14_Tukak_Reloc
Rate GBTS
Cabinet No.=0,
DA14_Tukak_Reloc
Subrack
09/17/2013
No.=0, Slot
23:22:58
No.=6, Port No.=1, Site N
E1/T1 Excessive
25806Bit Error
BBBL3/DA14_Tukak_Reloc
Rate GBTS
Cabinet No.=0,
DA14_Tukak_Reloc
Subrack
09/17/2013
No.=0, Slot
23:22:58
No.=6, Port No.=0, Site N
CDU Communication
2280
Alarm
BBBL3/D662_Nyelanding[HUB]
GBTS
Site No.=14,D662_Nyelanding[HUB]
Board Type=CDU,
09/17/2013
Board
20:41:14
No.=3, PassNo=255, Su
AC L1 Failure
6446
BBBL3/2272730L1_LubukBsr
GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DEMU,
09/17/2013Board
23:35:40
No.=0, PassNo=255,
E1/T1 Loss21202
of Frame Alignment
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
23:35:19
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Remote
21203
Alarm Indication
BBBL3 Signal
BSC6900 GSM
Subrack No.=0,
Slot No.=17,
Slot No.=17,
09/17/2013
Subrack
Subsystem
No=0,
23:34:33
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
22:29:23
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
19:42:50
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:12:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:11:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:01:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:00:43
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
12:48:40
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
03:33:06
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
03:32:44
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
07:49:21
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
10:38:09
Subsystem
No.=0, E1/T1
No.=0
Port No
Clock Reference
4708 Abnormal
BBBL3/2272730L1_LubukBsr
Alarm GBTS
Site No.=33,2272730L1_LubukBsr
Board Type=DTMU,
09/17/2013Board
23:48:34
No.=0, PassNo=255,
Clock Reference
2208 abnormal
BBBL3/DF50_BatuBeriga
Alarm GBTS
Site No.=2, DF50_BatuBeriga
Board Type=TMU,
09/17/2013
Board
23:42:43
No.=0, PassNo=255, Sub
Clock Reference
2208 abnormal
BBBL3/4149_Perlang
Alarm GBTS
Site No.=6, 4149_Perlang
Board Type=TMU,
09/17/2013
Board
23:42:43
No.=0, PassNo=255, Sub
Clock Reference
2208 abnormal
BBBL3/4167_Simpangklr
Alarm GBTS
Site No.=26,4167_Simpangklr
Board Type=TMU,
09/17/2013
Board
23:43:19
No.=0, PassNo=255, Su
Clock Reference
2208 abnormal
BBBL3/4662_LubukBesar[HUB]
Alarm GBTS
Site No.=17,4662_LubukBesar[HUB]
Board Type=TMU,
09/17/2013
Board
23:43:20
No.=0, PassNo=255, Su
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
05:25:00
Subsystem
No.=0, E1/T1
No.=0
Port No

09/17/2013 09/17/2013
23:29:49 23:50:52
< System operator >
09/17/2013 09/17/2013
23:30:44 23:50:52
< System operator >
09/17/2013 09/17/2013
23:30:48 23:50:52
< System operator >
09/17/2013 09/17/2013
23:32:04 23:50:52
< System operator >
09/17/2013 09/18/2013
23:32:21 00:59:18
< System operator >
09/17/2013 09/17/2013
23:32:39 23:50:52
< System operator >
09/17/2013 09/17/2013
23:32:58 23:50:52
< System operator >
09/17/2013 09/18/2013
23:33:35 05:12:16
< System operator >
09/17/2013 09/18/2013
23:33:35 00:59:18
< System operator >
09/17/2013 09/18/2013
23:33:35 00:59:18
< System operator >
09/17/2013 09/17/2013
23:35:04 23:50:52
< System operator >
09/17/2013 09/18/2013
23:35:10 00:59:18
< System operator >
09/17/2013 09/17/2013
23:35:38 23:50:52
< System operator >
09/17/2013 -23:36:36 09/17/2013 09/18/2013
23:40:24 05:12:16
< System operator >
09/17/2013 09/18/2013
23:40:33 00:59:18
< System operator >
09/17/2013 09/18/2013
23:40:43 00:59:18
< System operator >
09/17/2013 09/18/2013
23:40:46 00:59:18
< System operator >
09/17/2013 -23:41:29 09/17/2013 09/18/2013
23:42:41 00:59:18
< System operator >
09/17/2013 09/18/2013
23:42:55 00:59:18
< System operator >
09/17/2013 09/18/2013
23:43:20 00:59:18
< System operator >
09/17/2013 09/18/2013
23:43:47 05:12:16
< System operator >
09/17/2013 09/18/2013
23:44:00 00:59:18
< System operator >
09/17/2013 09/18/2013
23:44:52 06:18:43
< System operator >
09/17/2013 09/18/2013
23:50:39 00:59:18
< System operator >
09/17/2013 09/18/2013
23:50:40 03:10:45
< System operator >
09/17/2013 09/18/2013
23:50:40 03:10:45
< System operator >
09/17/2013 09/18/2013
23:50:40 03:10:45
< System operator >
09/17/2013 09/18/2013
23:50:52 03:10:45
< System operator >
09/17/2013 09/18/2013
23:50:52 03:10:45
< System operator >
09/17/2013 09/18/2013
23:57:46 00:59:18
< System operator >
09/18/2013 09/18/2013
00:32:04 00:59:18
< System operator >
09/18/2013 -00:56:23 09/18/2013 -00:56:23 09/18/2013 -00:56:23 09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 00:59:18
< System operator >
09/18/2013 09/18/2013
00:56:23 01:33:13
< System operator >
09/18/2013 09/18/2013
00:56:23 01:33:13
< System operator >
09/18/2013 09/18/2013
01:11:22 02:25:17
< System operator >
09/18/2013 09/18/2013
01:12:00 02:25:17
< System operator >
09/18/2013 -01:26:19 09/18/2013 09/18/2013
01:28:40 01:33:13
< System operator >
09/18/2013 -01:30:19 09/18/2013 09/18/2013
01:30:20 01:33:13
< System operator >
09/18/2013 09/18/2013
01:30:49 01:33:13
< System operator >
09/18/2013 -01:38:24 -

Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

Total 2,304 Records

E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:01:20
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
14:01:43
Subsystem
No.=0, E1/T1
No.=0
Port No
Rectifier module
2406 fault BBBL3/4696_Payung
GBTS
Site No.=56,4696_Payung
Board Type=EAC,
09/17/2013
Board
20:01:35
No.=0, PassNo=255, Su
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:56:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:56:56
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
04:42:41
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
16:11:31
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:19:47
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
15:19:25
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
17:56:56
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21207Bit Error
BBBL3
Rate BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
17:56:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
11:05:58
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:17:34
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=14,
Slot No.=14,
09/17/2013
Subrack
Subsystem
No=7,
14:05:12
Subsystem
No.=0, E1/T1
No.=0
Port No
E1/T1 Excessive
21208Slip Frames
BBBL3
BSC6900 GSM
Subrack No.=7,
Slot No.=15,
Slot No.=15,
09/17/2013
Subrack
Subsystem
No=7,
15:17:35
Subsystem
No.=0, E1/T1
No.=0
Port No

09/18/2013 09/18/2013
02:47:05 03:10:45
< System operator >
09/18/2013 09/18/2013
02:48:28 03:10:45
< System operator >
09/18/2013 09/18/2013
04:26:18 05:12:16
< System operator >
09/18/2013 09/18/2013
04:34:12 05:12:16
< System operator >
09/18/2013 09/18/2013
04:34:34 05:12:16
< System operator >
09/18/2013 09/18/2013
04:41:18 08:38:34
< System operator >
09/18/2013 09/18/2013
06:09:50 06:18:43
< System operator >
09/18/2013 09/18/2013
07:41:44 07:53:42
< System operator >
09/18/2013 09/18/2013
07:42:22 07:53:42
< System operator >
09/18/2013 09/18/2013
07:43:45 07:53:42
< System operator >
09/18/2013 09/18/2013
07:44:22 07:53:42
< System operator >
09/18/2013 09/18/2013
07:49:16 07:53:42
< System operator >
09/18/2013 09/18/2013
07:49:19 08:38:34
< System operator >
09/18/2013 09/18/2013
07:49:19 07:53:42
< System operator >
09/18/2013 09/18/2013
07:49:43 08:38:34
< System operator >