TABLE C1.

1
AXIAL LOAD CARRYING CAPACITY RATIO OF COLUMNS

Pu/Ag fck

Fck (N/mm )

Pt %
0.80
0.90
1.00
1.10
1.20
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
2.10
2.20
2.30
2.40
2.50
2.60
2.70
2.80
2.90
3.00

M15

0.545
0.563
0.581
0.600
0.618
0.636
0.654
0.672
0.690
0.708
0.726
0.745
0.763
0.781
0.799
0.817
0.835
0.853
0.872
0.890
0.908
0.926
0.944

M20

0.508
0.522
0.535
0.549
0.562
0.578
0.589
0.603
0.616
0.630
0.643
0.657
0.670
0.684
0.697
0.711
0.724
0.738
0.751
0.765
0.778
0.792
0.805

M25

0.486
0.496
0.507
0.518
0.529
0.539
0.550
0.561
0.572
0.582
0.593
0.604
0.614
0.625
0.636
0.647
0.657
0.668
0.679
0.689
0.700
0.711
0.722

M30

0.471
0.480
0.489
0.498
0.506
0.515
0.524
0.533
0.542
0.551
0.560
0.568
0.577
0.586
0.595
0.604
0.613
0.622
0.631
0.639
0.648
0.657
0.666

M35

0.460
0.468
0.475
0.483
0.491
0.498
0.506
0.513
0.521
0.528
0.536
0.543
0.551
0.558
0.566
0.574
0.581
0.589
0.596
0.604
0.611
0.619
0.626

M40

0.452
0.459
0.466
0.472
0.479
0.485
0.492
0.498
0.505
0.511
0.518
0.525
0.531
0.538
0.544
0.551
0.557
0.564
0.570
0.577
0.583
0.590
0.597

TABLE C1.1 (Continued)


AXIAL LOAD CARRYING CAPACITY RATIO OF COLUMNS

Pu/Ag fck

Fck (N/mm )

Pt %
3.20
3.40
3.60
3.80
4.00
4.20
4.40
4.60
4.80
5.00
5.20
5.40
5.60
5.80
6.00
1)

M15

0.980
1.017
1.053
1.089
1.125
1.162
1.198
1.234
1.271
1.307
1.343
1.379
1.416
1.452
1.488

M20

0.832
0.859
0.886
0.913
0.940
0.967
0.994
1.021
1.048
1.075
1.102
1.129
1.156
1.183
1.210

M25

0.743
0.765
0.786
0.807
0.829
0.850
0.872
0.893
0.915
0.936
0.958
0.979
1.000
1.022
1.043

M30

0.684
0.702
0.719
0.737
0.755
0.772
0.790
0.808
0.826
0.843
0.861
0.879
0.897
0.914
0.932

M35

0.641
0.657
0.672
0.687
0.702
0.717
0.732
0.747
0.762
0.777
0.792
0.807
0.823
0.838
0.853

M40

0.610
0.623
0.636
0.649
0.662
0.675
0.688
0.701
0.714
0.728
0.741
0.754
0.767
0.780
0.793

Note:
The design load of axially loaded short column is calculated when the
minimum Eccentricity does not exceed 0.05 times the lateral dimension of
column using the formula
Pu=0.4 fck As +0.67 f y Asc where Pu is Factored Axial load on the member
Ac = Area of concrete
Asc =Area of longitudinal reinforcement

2)

Based on the above formula and charts given in Design Aid to IS 456 1978
The value of Pu/Ag fck =0.4 + p/100{ 0.67 fy/ fck 0.4} can be found out
and tabulated in the above form.

TABLE C.2
TRANSVERSE REINFORCEMENT FOR COLUMNS
Maximum Pitch of Lareral Ties

Smallest
Dia of
Longitudinal
bar
12

Dia of Lateral Ties in mm

Remarks

10

190

--

--

But >

16

250

250

--

But >

20

280

280

--

But >

25

--

300

--

But >

30

---

300

--

But >

32

---

300

--

But >

36

--

--

300

But >

Note:
1)
Minimum Dia. Of lateral ties is greater of the following:
i)
6mm
ii)
the dia of largest longitudinal bar.
2)

Maximum dia of ties is 16 mm.

3)

Maximum spacing of ties is least of the following:


i)
Least lateral dimension of columns
ii)
16 times the dia of smallest longitudinal bar
iii)
300 mm.