You are on page 1of 1

1

5 6 7 8 9 10 11

12

13

14

15

16

T-2357 P-2357A/B
ANTI-FOAM INJECTION PUMPS
CAPACITY: 0-150L

ANTI-FOAM TANK CAPACITY: 10m DxH=2x3m Operating pressure: atm Operating temp.: amb P: 1380 kPag Design temp.: 85C Motor: 1.1 KW

A-2357
2" 2" 2" 24" MW 2" 1/2" 1/2" 1"
B

ANTI-FOAM SKID CAPACITY: 0-150L

T-2357
1/2"
1 12" 1 12"

3"

1 12 "
D

1/2"

1 12 "

FI

1 12 "

316

1 12 "

ANTI-FOAM TO NEW FACILITY PRODUCTION FLUID HEADER 1

2"
E

NC

1 12 "

FI

1 12 "

AUTO/ DUTY/ OFF/ STANDBY MANUAL STOP START

1 12 " 1 12 " 1 12 "

AUTO/ DUTY/ OFF/ STANDBY MANUAL STOP

1 12 "
START

1 12 "

317

1 12 "

ANTI-FOAM TO NEW FACILITY PRODUCTION FLUID HEADER 2

1 12 "
D C B A

D C
F

1/2"

1/2"

1/2" 3/4" LO 3/4" 2" 3/4"

1/2" LO 3/4"

3/4"
1 12 " 1 12 " 1 12 "

3/4"
1 12 " 1 12 "

1/2"

2"
H

P-2357A
Note 1

1/2"

P-2357B
2"
Note 1

SKID LIMIT
I

SLOPE 1:200
J

For bidding

24.09.2013

A.S.

S.C.

M.M.

Rev.

Description

Date

Prepared

Checked

Approved

CLIENT: PETRODAR OPERATING COMPANY LTD

CONTRACTOR: STAR CONSULTING OIL & GAS

NOTE:
Note 1 Future connection for PT

This document is the property of PETRODESIGN and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization. We will claim legal protection against any abuse.

PALOUGE FPF DEBOTTLENECKING PROJECT

ANTI-FOAM INJECTION SKID


K

Preliminary P&ID

Owners Drawing No.

Scale

Size

Contractors Drawing No.

A1

Clients Drawing No.

Sheet

Cont.

PETRODESIGNs Drawing No.


1 2 3 4 5 6 7 8 9 10 11 12

PD/726001-BID-000000-2100-0001-1-PID

13

14

15

16

You might also like