5 6 7 8 9 10 11
12
13
14
15
16
T-2357 P-2357A/B
ANTI-FOAM INJECTION PUMPS
CAPACITY: 0-150L
ANTI-FOAM TANK CAPACITY: 10m DxH=2x3m Operating pressure: atm Operating temp.: amb P: 1380 kPag Design temp.: 85C Motor: 1.1 KW
A-2357
2" 2" 2" 24" MW 2" 1/2" 1/2" 1"
B
T-2357
1/2"
1 12" 1 12"
3"
1 12 "
D
1/2"
1 12 "
FI
1 12 "
316
1 12 "
2"
E
NC
1 12 "
FI
1 12 "
1 12 "
START
1 12 "
317
1 12 "
1 12 "
D C B A
D C
F
1/2"
1/2"
1/2" LO 3/4"
3/4"
1 12 " 1 12 " 1 12 "
3/4"
1 12 " 1 12 "
1/2"
2"
H
P-2357A
Note 1
1/2"
P-2357B
2"
Note 1
SKID LIMIT
I
SLOPE 1:200
J
For bidding
24.09.2013
A.S.
S.C.
M.M.
Rev.
Description
Date
Prepared
Checked
Approved
NOTE:
Note 1 Future connection for PT
This document is the property of PETRODESIGN and it is not allowed to reproduce it, as well as to communicate its content to others in any way without our written authorization. We will claim legal protection against any abuse.
Preliminary P&ID
Scale
Size
A1
Sheet
Cont.
PD/726001-BID-000000-2100-0001-1-PID
13
14
15
16