H

S
T
I
N
T
E
G
R
A
L
21st CENTURY AERATION TECHNOLOGY
HST I NTEGRAL AERATI ON COMPRESSORS
HST Integral turbo-compressors are
one stage radial turbo-compressors
whose construction, properties,
operation and connections are all
designed to meet the requirements of
aeration systems. The modern
ungeared, frequency-converter-
controlled electric motor drive together
with the lubricant-free magnetic
bearings guarantee an economical,
reliable and service-free operation of
the compressor.
Rotation speed control
Variable rotation speed control through
integrated frequency converter is optimal
control for radial turbo-compressor. There
is no need for any mechanical control
equipment.
Easy installation
HST Integral is a compact, factory tested,
ready-to-install unit. This results as
savings in building costs and installation.
For example, there is no need for crane or
foundation base plate. Compact size and
light weight allow quick and easy
installation.
Total oil-free operation
HST Integral has a frictionless drive
equipped with magnetic bearings and
integrated frequency converter. There will
be no risk of oil leakage or costly spillage in
the very media you are treating.
Minimal maintenance
The complete control and operation system
is electronic. The only thing to need
periodic replacement are the air filters.
Flexible configuration
The easy-to-install HST Integral
compressors can be used for building new
plants and expanding old ones as well as to
replace other compressors. Configurable to
your changing requirements HST Integral
compressors can be flexibly configured in
groups to suit your aeration requirement.
Optimal parallel use
The modular controller optimizes the
operation of compressor group to match the
desired output. Controlling the group is as
easy as controlling a single unit. Group
control optimizes the operation of the whole
group in terms of output and energy
consumption.
S2500 series
S6000 series
S9000 series
NOPON OY - HST Division
Teollisuuskatu 9,
FIN-53600 Lappeenranta, Finland
Tel +358-5-610 9631
Fax +358-5-610 9650
email: marketing@highspeedtech.fi
Internet: http://www.highspeedtech.fi
All HST Integral turbo-compressors have been designed and manufactured to be connected to industrial network in accordance
with EN 61800-3, EMC product standard for adjustable speed electrical power drive system.
H
S
T
I
N
T
E
G
R
A
L
NOPON OY
Turvekuja 6,
FIN-00700 Helsinki, Finland
Tel. +358-9-351 730
Fax +358-9-351 5620
Email: hq@nopon.fi
Internet: http://www.nopon.fi
S2500 series S6000 series S9000 series
Flow range (m3/h) 1000 - 3400 2600 - 7000 3700 - 9500
Pressure range (kPa) 30 - 125 30 - 125 30 - 85
Length L (cm) 142 178-199 204
Width W (cm) 93 135 135
Height H (cm) 189 189 200
Weight (kg) 750 1350-1500 1700
Inlet flange DN 200 DN 250 DN 400
Outlet flange DN 125 DN 200 DN 300
Mains connections
Analogue inputs
Analogue outputs
Binary inputs
Binary outputs
400V/500V/690V 50/60 Hz
48 V ac/dc
4 - 20 mA
4 -20 mA
24 Vdc
TECHNICAL INFORMATION
Sectional drawing showing the only
moving component: combined shaft,
impeller and cooling fan.
A group of four HST Integral S6000-1-L in
Vsters WWTP, Sweden. The group is
controlled by HST MCU modular controller.
A company in the ABS group
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S2500-1-L -4/5/6
500115, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500115, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 112 A / 69 kW
Power supply 500 V / 50/60 Hz / 90 A / 69 kW
Power supply 690 V / 50/60 Hz / 65 A / 69 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, RL < 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, RL < 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 200
Process air outlet DN 125
*The outlet must have a back pressure valve minimum DN200
Cooling air inlet 160 mm
Cooling air outlet (cabinet) 160 mm
Cooling air outlet (motor) 160 mm
Cooling air minimum flow (cabinet) 15 m3/min
Cooling air minimum flow (motor) 20 m3/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500115, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 81 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 750 kg
500115, rev D All rights reserved
High Speed Tech Oy Ltd
I S2500 -1-L Tol. (mm)
H1 1273 10
H2 1030 10
H3 1890 5
H4 510 5
H5 1625 10
L1 1420 10
L2 550 10
L3 485 2
L4 280 10
L5 190 10
L6 382 5
L7 395 10
W1 830 5
W2 245 10
W3 208 5
W4 200 5
W5 930 5
W6 250 5
W7 880 2
D1 160
D2 tube
160
D3 tube
DN100
Inlet
Flange
DN200
Outlet
Flange
DN125
500115, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
-10C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
970 1444 1933 2415
Inlet Flow [m/h]
2899 3370 3870
40 kPa
50 kPa 60 kPa
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
0C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1000 1500 2007 2511
Inlet Flow [m/h]
3022 3518 4015
40 kPa
50 kPa 60 kPa
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
+10C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1037 1556 2081 2607
Inlet Flow [m/h]
3125 3648 4163
40 kPa
50 kPa 60 kPa
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
+20C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1067 1615 2163 2704
Inlet Flow [m/h]
3245 3778 4311
40 kPa
50 kPa 60 kPa
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
+30C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1119 1674 2244 2794
Inlet Flow [m/h]
3363 3935 4489
40 kPa
50 kPa 60 kPa
500115, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-L
+40C, 101.13 kPa, RH 50 %
20
30
40
50
60
70
80
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1141 1741 2326 2926
Inlet Flow [m/h]
3490 4080 4667
40 kPa
50 kPa 60 kPa
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S2500-1-H-4/5/6
500116, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500116, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 135 A / 83 kW
Power supply 500 V / 50/60 Hz / 108 A / 83 kW
Power supply 690 V / 50/60 Hz / 78 A / 83 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, RL < 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, RL < 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 200
Process air outlet DN 125
*The outlet must have a back pressure valve minimum DN200
Cooling air inlet 160 mm
Cooling air outlet (cabinet) 160 mm
Cooling air outlet (motor) 160 mm
Cooling air minimum flow (cabinet) 15 m3/min
Cooling air minimum flow (motor) 20 m3/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500116, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 81 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 750 kg
500116, rev D All rights reserved
High Speed Tech Oy Ltd
I S2500 -1-H Tol. (mm)
H1 1273 10
H2 1030 10
H3 1890 5
H4 510 5
H5 1625 10
L1 1420 10
L2 550 10
L3 485 2
L4 280 10
L5 190 10
L6 382 5
L7 395 10
W1 830 5
W2 245 10
W3 208 5
W4 200 5
W5 930 5
W6 250 5
W7 880 2
D1 160
D2 tube
160
D3 tube
DN100
Inlet
Flange
DN200
Outlet
Flange
DN125
500116, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
-10C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
970 1444 1933 2415
Inlet Flow [m/h]
2899 3370 3870
60 kPa 70 kPa 80 kPa
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
0C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1000 1500 2007 2511
Inlet Flow [m/h]
3022 3518 4015
60 kPa 70 kPa 80 kPa
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
+10C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1037 1556 2081 2607
Inlet Flow [m/h]
3125 3648 4163
60 kPa 70 kPa 80 kPa
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
+20C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1067 1615 2163 2704
Inlet Flow [m/h]
3245 3778 4311
60 kPa 70 kPa 80 kPa
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
+30C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1119 1674 2244 2794
Inlet Flow [m/h]
3363 3935 4489
60 kPa 70 kPa 80 kPa
500116, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-1-H
+40C, 101.13 kPa, RH 50 %
30
40
50
60
70
80
90
1000 1500 2000 2500 3000 3500 4000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1141 1741 2326 2926
Inlet Flow [m/h]
3490 4080 4667
60 kPa 70 kPa 80 kPa
HIGH
SPEED
TECH
TECHNICAL DATA
Rev C
HST INTEGRAL
S2500-2-L -4/5
500171, rev C All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500171, rev C All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 157 A / 97 kW
Power supply 500 V / 50/60 Hz / 126 A / 97 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed electrical
power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, R
L
< 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, R
L
< 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 200
Process air outlet DN 125
*The outlet must have a back pressure valve minimum DN200
Cooling air inlet 160 mm
Cooling air outlet (cabinet) 160 mm
Cooling air outlet (motor) 160 mm
Cooling air minimum flow (cabinet) 15 m
3
/min
Cooling air minimum flow (motor) 20 m
3
/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500171, rev C All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 85 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 900 kg
500171, rev C All rights reserved
High Speed Tech Oy Ltd
I S2500 -2-L Tol.
(mm)
H1 1350 10
H2 1016 10
H3 1890 5
H4 510 5
H5 1602 10
L1 1469 10
L2 549 10
L3 535 2
L4 324 10
L5 190 10
L6 432 5
L7 395 10
W1 830 5
W2 245 10
W3 200 5
W4 200 5
W5 930 5
W6 250 5
W7 880 2
D1 160
D2
tube
160
D3
tube
DN125
Inlet
Flang
e
DN200
Outlet
Flange
DN125
500171, rev C All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliarypower
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
-10C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
970 1444 1933 2415
Inlet Flow [m/h]
100 kPa90 kPa 80 kPa
2899
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
0C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1000 1500 2007 2511
Inlet Flow [m/h]
100 kPa 90 kPa 80 kPa
3012
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
+10C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1037 1556 2081 2607
Inlet Flow [m/h]
100 kPa 90 kPa 80 kPa
3125
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
+20C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1067 1615 2163 2704
Inlet Flow [m/h]
100 kPa 90 kPa 80 kPa
3245
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
+30C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1119 1674 2244 2794
Inlet Flow [m/h]
100 kPa90 kPa 80 kPa
3357
500171, rev C All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-L
+40C, 101.13 kPa, RH 50 %
20
40
60
80
100
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1141 1741 2326 2911
Inlet Flow [m/h]
100 kPa 90 kPa 80 kPa
3485
HIGH
SPEED
TECH
TECHNICAL DATA
Rev B
HST INTEGRAL
S2500-2-H -4/5
500158, rev B All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500158, rev B All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 179 A / 110 kW
Power supply 500 V / 50/60 Hz / 143 A / 110 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed electrical
power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, R
L
< 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, R
L
< 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 200
Process air outlet DN 125
*The outlet must have a back pressure valve minimum DN200
Cooling air inlet 160 mm
Cooling air outlet (cabinet) 160 mm
Cooling air outlet (motor) 160 mm
Cooling air minimum flow (cabinet) 15 m
3
/min
Cooling air minimum flow (motor) 20 m
3
/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500158, rev B All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 85 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 900 kg
500158, rev B All rights reserved
High Speed Tech Oy Ltd
I S2500 -2-H Tol.
(mm)
H1 1350 10
H2 1016 10
H3 1890 5
H4 510 5
H5 1602 10
L1 1469 10
L2 549 10
L3 535 2
L4 324 10
L5 190 10
L6 432 5
L7 395 10
W1 830 5
W2 245 10
W3 200 5
W4 200 5
W5 930 5
W6 250 5
W7 880 2
D1 160
D2
tube
160
D3
tube
DN125
Inlet
Flang
e
DN200
Outlet
Flange
DN125
500158, rev B All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliarypower
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
-10C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
970 1444 1933 2415
Inlet Flow [m/h]
120 kPa110 kPa
100 kPa
2899
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
0C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1000 1500 2007 2511
Inlet Flow [m/h]
120 kPa 110 kPa100 kPa
3012
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
+10C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1037 1556 2081 2607
Inlet Flow [m/h]
120 kPa110 kPa100 kPa
3125
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
+20C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1067 1615 2163 2704
Inlet Flow [m/h]
120 kPa 110 kPa100 kPa
3245
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
+30C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1119 1674 2244 2794
Inlet Flow [m/h]
120 kPa110 kPa100 kPa
3357
500158, rev B All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S2500-2-H
+40C, 101.13 kPa, RH 50 %
40
60
80
100
120
1000 1500 2000 2500 3000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
1141 1741 2326 2911
Inlet Flow [m/h]
120 kPa110 kPa100 kPa
3485
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S6000-1-L-4/5/6
500117, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500117, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 260 A / 160 kW
Power supply 500 V / 50/60 Hz / 208 A / 160 kW
Power supply 690 V / 50/60 Hz / 151 A / 160 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, R
L
< 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, R
L
< 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 250
Process air outlet DN 200
*The outlet must have a back pressure valve minimum DN250
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 200 mm
Cooling air minimum flow (cabinet) 35 m
3
/min
Cooling air minimum flow (motor) 30 m
3
/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500117, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 81 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1350 kg
500117, rev D All rights reserved
High Speed Tech Oy Ltd
I S6000-1-L Tol. (mm)
H1
2065 10
H2 1720 10
H3 1365 10
H4 310 5
H5 1890 5
L1 1780 5
L2 830 10
L3 594 2
L4 484 5
L5 375 10
L6 250 10
L7 1749 5
W1 1210 2
W2 370 10
W3 250 5
W4 250 5
W5 400 5
W6 1350 2
D1 250
D2 tube 200
D3 tube DN125
Inlet
Flange
DN250
Outlet
Flange
DN200
500117, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
-10C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
2889 3867 4844 5778
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
7719 6726
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
0C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3022 4015 5037 6015
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
8025 7022
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
+10C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3111 4163 5215 6237
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
8319 7289
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
+20C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3215 4311 5422 6489
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
8630 7556
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
+30C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3363 4667 5615 6711
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
8963 7852
500117, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-L
+40C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
3000 4000 5000 6000 7000 8000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3481 4667 5852 6981
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
9333 8148
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S6000-1-H-4/5/6
500118, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500118, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 310 A / 190 kW
Power supply 500 V / 50/60 Hz / 247 A / 190 kW
Power supply 690 V / 50/60 Hz / 179 A / 190 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, RL < 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, RL < 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 250
Process air outlet DN 200
*The outlet must have a back pressure valve minimum DN250
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 200 mm
Cooling air minimum flow (cabinet) 35 m3/min
Cooling air minimum flow (motor) 30 m3/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500118, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 81 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1350 kg
500118, rev D All rights reserved
High Speed Tech Oy Ltd
I S6000 -1-H Tol. (mm)
H1 2070 10
H2 1730 10
H3 1370 5
H4 310 5
H5 1890 10
L1 1780 10
L2 830 10
L3 834 2
L4 724 10
L5 375 10
L6 250 10
L7 1989 5
W1 1210 5
W2 370 10
W3 300 5
W4 250 2
W5 400 5
W6 1350 2
D1 250
D2 tube
200
D3 tube
DN125
Inlet
Flange
DN250
Outlet
Flange
DN200
500118, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
-10C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
2889 3867 4844 5778
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
6726
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
0C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3022 4015 5037 6015
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
7022
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
+10C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3111 4163 5215 6237
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
7289
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
+20C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3215 4311 5422 6489
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
7556
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
+30C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3363 4489 5615 6711
Inlet Flow [m/h]
60 kPa
50 kPa
40 kPa
7852
500118, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-1-H
+40C, 101.13 kPa, RH 50 %
40
60
80
100
120
140
160
180
200
3000 4000 5000 6000 7000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3481 4667 5852 6981
Inlet Flow [m/h]
60 kPa 50 kPa
40 kPa
8148
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S6000-2-L-4/5/6
500119, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500119, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 390 A / 240 kW
Power supply 500 V / 50/60 Hz / 312 A / 240 kW
Power supply 690 V / 50/60 Hz / 226 A / 240 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, RL < 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, RL < 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 250
Process air outlet DN 200
*The outlet must have a back pressure valve minimum DN250
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 200 mm
Cooling air minimum flow (cabinet) 35 m3/min
Cooling air minimum flow (motor) 30 m3/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500119, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 83 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1500 kg
500119, rev D All rights reserved
High Speed Tech Oy Ltd
I S6000 2-L Tol. (mm)
H1 2070 10
H2 1730 10
H3 1370 5
H4 310 5
H5 1890 10
L1 1780 10
L2 830 10
L3 834 2
L4 724 10
L5 375 10
L6 250 10
L7 1989 5
W1 1210 5
W2 370 10
W3 300 5
W4 250 2
W5 400 5
W6 1350 2
D1 250
D2 tube
200
D3 tube
DN125
Inlet
Flange
DN250
Outlet
Flange
DN200
500119, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
-10C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
2889 3867 4844 5807
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
6726
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
0C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3022 4015 5037 6015
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
7022
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
+10C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3111 4163 5215 6237
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
7289
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
+20C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3215 4311 5422 6489
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
7556
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
+30C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3363 4489 5615 6711
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
7852
500119, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-L
+40C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3481 4667 5852 6981
Inlet Flow [m/h]
100 kPa
90 kPa
80 kPa
8148
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S6000-2-H-4/5/6
500120, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been
applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500120, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 390 A / 240 kW
Power supply 500 V / 50/60 Hz / 312 A / 240 kW
Power supply 690 V / 50/60 Hz / 226 A / 240 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed and manufactured to be connected to industrial network in
accordance with EN61800-3 standard. (EMC product standard for adjustable speed
electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, RL < 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, RL < 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 250
Process air outlet DN 200
*The outlet must have a back pressure valve minimum DN250
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 200 mm
Cooling air minimum flow (cabinet) 35 m3/min
Cooling air minimum flow (motor) 30 m3/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500120, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 83 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1500 kg
500120, rev D All rights reserved
High Speed Tech Oy Ltd
I S6000 2-H Tol. (mm)
H1 2070 10
H2 1730 10
H3 1370 5
H4 310 5
H5 1890 10
L1 1780 10
L2 830 10
L3 834 2
L4 724 10
L5 375 10
L6 250 10
L7 1989 5
W1 1210 5
W2 370 10
W3 300 5
W4 250 2
W5 400 5
W6 1350 2
D1 250
D2 tube
200
D3 tube
DN125
Inlet
Flange
DN250
Outlet
Flange
DN200
500120, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMBfault, alarm, reset
Measure of inlet- and output
pressure
Blowoff valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
HighSpeedUnit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
-10C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
2889 3867 4844 5807
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
6726
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
0C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3022 4015 5037 6015
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
7022
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
+10C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3111 4163 5215 6237
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
7289
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
+20C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3215 4311 5422 6489
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
7556
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
+30C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3363 4489 5615 6711
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
7852
500120, rev D All rights reserved
High Speed Tech Oy Ltd
HST INTEGRAL S6000-2-H
+40C, 101.13 kPa, RH 50 %
80
100
120
140
160
180
200
220
240
260
3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Compressor tests according to ISO 5389
Scale accuracy 3%
Pressure Rise
3481 4667 5852 6981
Inlet Flow [m/h]
120 kPa 110 kPa 100 kPa
8148
HIGH
SPEED
TECH
TECHNICAL DATA
Rev C
HST INTEGRAL
S9000-1-L- 4/5/6
500167, rev C All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500167, rev C All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 310 A / 190 kW
Power supply 500 V / 50/60 Hz / 247 A / 190 kW
Power supply 690 V / 50/60 Hz / 179 A / 190 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed to be connected to industrial network in accordance with EN61800-3
standard. (EMC product standard for adjustable speed electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, R
L
< 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, R
L
< 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 400
Process air outlet DN 300
*The outlet must have a back pressure valve minimum DN400
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 250 mm
Cooling air minimum flow (cabinet) 40 m
3
/min
Cooling air minimum flow (motor) 35 m
3
/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500167, rev C All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 83 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1700 kg
500167, rev C All rights reserved
High Speed Tech Oy Ltd
I S9000 -1 Tol.
(mm)
H1 2252 10
H2 1857 10
H3 1443 10
H4 310 5
H5 2000 5
L1 1780 5
L2 830 10
L3 890 2
L4 747 5
L5 375 10
L6 250 10
L7 2045 10
W1 1210 2
W2 370 10
W3 310 5
W4 320 5
W5 400 5
W6 1350 2
D1 250
D2
tube
250
D3
tube
DN150
Inlet
Flang
e
DN400
Outlet
Flange
DN300
500167, rev C All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMB fault, alarm, reset
Measure of inlet- and output
pressure
Blow off valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
High Speed Unit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
HST INTEGRAL S9000-1-L
-10C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
Pressure Rise
3863 4829 5794 6760 7726 8691 9657
Inlet Flow [m/h]
60 kPa
50 kPa 40 kPa
HST INTEGRAL S9000-1-L
0C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
Pressure Rise
4012 5015 6018 7022 8025 9037 10031
Inlet Flow [m/h]
60 kPa 50 kPa 40 kPa
HST INTEGRAL S9000-1-L
+10C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4164 5205 6246 7287 8328 9369 10410
Inlet Flow [m/h]
Pressure Rise
60 kPa 50 kPa 40 kPa
HST INTEGRAL S9000-1-L
+20C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4320 5400 6480 7560 8640 9720 10800
Inlet Flow [m/h]
Pressure Rise
60 kPa 50 kPa 40 kPa
HST INTEGRAL S9000-1-L
+30C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4483 5604 6725 7846 8967 10088 11209
Inlet Flow [m/h]
Pressure Rise
60 kPa 50 kPa 40 kPa
HST INTEGRAL S9000-1-L
+40C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4659 5824 6988 8153 9318 10482 11647
Inlet Flow [m/h]
Pressure Rise
60 kPa 50 kPa 40 kPa
HIGH
SPEED
TECH
TECHNICAL DATA
Rev D
HST INTEGRAL
S9000-1-H-4/5/6
500156, rev D All rights reserved
High Speed Tech Oy Ltd
EC DECLARATION OF CONFORMITY
We
Manufacturer: High Speed Tech Oy Ltd
Address: Teollisuuskatu 9
53600 Lappeenranta
FINLAND
Herewith declares that
HST Integral turbocompressors, types
S2500 -1-L, S2500 -1-H, S2500 -2-L, S2500 -2-H,
S6000 -1-L, S6000 -1-H, S6000 -2-L, S6000 -2-H,
S9000 -1-L, S9000 -1-H
is in conformity with the provisions of
EU Machinery Directive (Directive 89/392/EU)
EU Low-Voltage Equipment Directive (73/23/EU)
EU Directitive on Electromagnetic Compatibility (89/336/EU)
and furthermore declares that the following (parts/clauses of) harmonised standards have been applied
EN 1012, EN 60204, EN 61800-3
EN 292, EN 294, EN418,
EN 563 and prEN 953
Lappeenranta 4. 4. 2000
High Speed Tech Oy Ltd
Heikki Kellomki
Managing Director
500156, rev D All rights reserved
High Speed Tech Oy Ltd
TECHNICAL SPECIFICATIONS
MAINS CONNECTIONS
Power supply 400 V / 50/60 Hz / 390 A / 240 kW
Power supply 500 V / 50/60 Hz / 312 A / 240 kW
Power supply 690 V / 50/60 Hz / 226 A / 240 kW
Auxiliary supply As above / 10 A / 1 kW
Product has been designed to be connected to industrial network in accordance with EN61800-3
standard. (EMC product standard for adjustable speed electrical power drive system.)
CONTROL CONNECTIONS
Analogue inputs 4-20mA, R
L
< 500
Binary inputs 24 Vdc
Analogue output 4-20 mA, R
L
< 500
Binary outputs 48 Vac / dc / 2 A
PIPING CONNECTIONS
Process air inlet DN 400
Process air outlet DN 300
*The outlet must have a back pressure valve minimum DN400
Cooling air inlet 250 mm
Cooling air outlet (cabinet) 250 mm
Cooling air outlet (motor) 250 mm
Cooling air minimum flow (cabinet) 40 m
3
/min
Cooling air minimum flow (motor) 35 m
3
/min
AMBIENT CONDITIONS
Storage and transportation
Temperature -40...+60 C, no freezing
Humidity, RH <95 %, no condensing
Operating
Temperature +5...+40 C
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
Process Air Inlet
Temperature -30...+40 C, no freezing
Humidity <95 %, no condensing
Maximum installation altitude 1000m above sea level
*Not included in compressor delivery
500156, rev D All rights reserved
High Speed Tech Oy Ltd
Air Quality
Chemical vapours IEC 721-3-3
Mechanical particles IEC 721-3-3
Chemical vapours according to IEC 721-3-3
standard
Ave. / Max.
[mg/m]
Sulphur dioxide 0,3 / 1,0
Hydrogen sulphide 0,1 / 0,5
Chlorine 0,1 / 0,3
Hydrogen chloride 0,1 / 0,5
Hydrogen fluoride 0,01 / 0,03
Ammonia 1,0 / 3,0
Ozone 0,05 / 0,1
Nitrogen oxides 0,5 / 1,0
NOISE LEVEL
Noise pressure level (L
p,mean,1 m
) ISO 9614-2 < 83 dB (A)
THERMAL POWER
Thermal power 10...13% of input power
WEIGHT
Total weight 1700 kg
500156, rev D All rights reserved
High Speed Tech Oy Ltd
I S9000 -1 Tol.
(mm)
H1 2252 10
H2 1857 10
H3 1443 10
H4 310 5
H5 2000 5
L1 1780 5
L2 830 10
L3 890 2
L4 747 5
L5 375 10
L6 250 10
L7 2045 10
W1 1210 2
W2 370 10
W3 310 5
W4 320 5
W5 400 5
W6 1350 2
D1 250
D2
tube
250
D3
tube
DN150
Inlet
Flang
e
DN400
Outlet
Flange
DN300
500156, rev D All rights reserved
High Speed Tech Oy Ltd
Block Diagram
Process air
outlet
Process air inlet
Option
Board
VACON
Basic
Control
Board
AMB
controller
X,Y,Z,n
measurement
Customer serial
comm.
Customer
terminals
Cooling air filter blockage alarm
AMB fault, alarm, reset
Measure of inlet- and output
pressure
Blow off valve control
Pt-100 temperature
measurement motor
winding and inlet air
Control panel
Control cabinet
Auxiliary power
supply (3-phase)
3-phase power
supply
220Vac
F5-6
F3-4
X5
X2
X1
K4
U1
L1
A1
X1
X,Y,Z
magn.
K1-3,5-6
High Speed Unit
CONNECTIONS
Motor cooling air outlet
Motor cooling air inlet
Process
Air Inlet
Process
Air Outlet
Power
Supply
Auxiliary
Supply
Serial
bus
4-20 mA
control
ReadyRun Fault Run/
Stop
4-20 mA
actual
value
Inputs Outputs
Control box cooling air outlet
Control box cooling air inlet
HST Integral
Alarm Re-
set
Inter-
lock
HST INTEGRAL S9000-1-H
-10C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
Pressure Rise
3863 4829 5794 6760 7726 8691 9657
Inlet Flow [m/h]
80 kPa 70 kPa 60 kPa
HST INTEGRAL S9000-1-H
0C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
Pressure Rise
4012 5015 6018 7022 8025 9037 10031
Inlet Flow [m/h]
80 kPa 70 kPa 60 kPa
HST INTEGRAL S9000-1-H
+10C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4164 5205 6246 7287 8328 9369 10410
Inlet Flow [m/h]
Pressure Rise
80 kPa 70 kPa 60 kPa
HST INTEGRAL S9000-1-H
+20C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4320 5400 6480 7560 8640 9720 10800
Inlet Flow [m/h]
Pressure Rise
80 kPa 70 kPa 60 kPa
HST INTEGRAL S9000-1-H
+30C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4483 5604 6725 7846 8967 10088 11209
Inlet Flow [m/h]
Pressure Rise
80 kPa 70 kPa 60 kPa
HST INTEGRAL S9000-1-H
+40C, 101.13 kPa, RH 50 %
60
80
100
120
140
160
180
200
220
240
260
4000 5000 6000 7000 8000 9000 10000 11000
Inlet Flow [Nm/h]
0C, 101.32kPa, RH 0%
I
n
p
u
t

P
o
w
e
r

[
k
W
]
Calculated data
Scale accuracy 3%
4659 5824 6988 8153 9318 10482 11647
Inlet Flow [m/h]