UNIVERSAL TESTING LABORATORY AND INSPECTION, INC.

147 Pasig Boulevard, Brgy. Pineda, Pasig City, Metro Manila, Philippines

TEST REPORT ON FIELD CORED CONCRETE SAMPLE (ASTM C-42)


Customer/Contractor
Project
Location
Date Submitted
Sampled/Submitted by

:
:
:
:
:

YUCHENGCO TOWER BUILDING


STRUCTURAL INVESTIGATION
QUINTIN PAREDES ST. BINONDO MANILA
OCTOBER 20, 2013
UTLII REPRESENTATIVE

Date Tested: OCTOBER 22 ,2013

Mpa

Psi

CORRECTED
COMPRESSIVE
STRENGTH
Psi

105.1

12.4

1798

1798.0

8107

118.5

14

2030

2030.0

1.00000

8107

87.2

10.3

1494

1493.5

2.030

1.00000

8107

1187.5

13.9

2016

2015.5

209.20

2.030

1.00000

8107

121.5

14.4

2088

2088.0

204.20

215.10

2.060

1.00000

8107

132.4

15.6

2262

2262.0

134.20

140.50

1.350

0.94200

8107

95.1

11.7

1697

1598.1

101.60

8107

163.9

20.2

2929

Slab(ground flr.

101.60

8107

104.9

12.9

1871

Slab(ground flr.

101.60

8107

96.2

11.9

1726

LENGTH (mm)

STRENGTH
CORRECTION
FACTOR

CROSS
SECTIONAL
AREA, mm2

COMPRESSIVE
LOAD (kN)

2.090

1.00000

8107

204.30

1.980

1.00000

204.60

212.00

2.050

101.60

202.30

212.10

Beam midspan

101.60

203.70

4/B-C

Beam midspan

101.60

4/D-A

Beam(ground flr.

101.60

A/4-5

Slab(ground flr.

B-C/3-4
B-C/2-3

CORE
SAMPLE
ID

ACTUAL
DIAMETER
(mm)

LOCATION

AFTER

D-4

Column basement

101.60

204.00

208.30

D-2

Column basement

101.60

199.30

A-3

Column basement

101.60

A BET.2-3

Beam(ground flr.

3/B-C

AFTER

L/D

CAPPING

REMARKS:

This report is the result of test performed on the specimen submitted.

Tested by:

Checked by:
R. B. Dela Cruz
Laboratory Supervisor

COMPRESSIVE
STRENGTH

Certified by:
P. P. Lopez
Managing Director