RSLogix 5000 Enterprise Software Windows 7 Statement

March 21, 2011


RSLogix 5000 software versions 18 or earlier have not been qualified on Windows 7 but are known to operate correctly. Versions 12 and earlier will not function on Windows 7. The following Windows 7 configuration settings are suggested to help ensure proper operation of RSLogix 5000. These apply to both 32 and 64 bit versions of Windows 7.

RSLogix 5000 Version Windows 7 Configuration Restriction User Admin Privileges required at Install User Admin Privileges required at Runtime UAC Disabled (User Access Control) AERO Desktop Disabled (classic View recommended) V13 V15 V16 V17 V18 V19

The following minimum companion software versions must be installed. These are available on the original V19 (or later) media. Installing V19 before attempting to run older versions of RSLogix 5000 in Windows 7 will help assure the updated companion software is properly installed. Installing from pre-V19 media may not install the required versions.

Companion Software Microsoft.Net Framework Microsoft.Net Framework Windows Firewall Configuration Utility FT Diagnostics ControlFlash Adobe Acrobat Reader FT Services Platform RSLinx Classic FT Activation Manager

Version 1.1 3.5 V1.00.0 V2.3.01 V9.0 V9.3.3 V2.30.01 V2.57.00 V3.30.00

If other Rockwell Software products are also needed, ensure that the Windows 7 compatible versions are also installed. The compatibility information can be found in the Rockwell automation technical support Knowledgebase AID 42682

Additional Considerations for Windows 7


Running RSLogix 5000 software via Remote Desktop is not supported. WinHelp is not included on Windows Vista or Windows 7 and must be installed separately for RSLogix 5000 versions to properly display help. WinHelp can be downloaded directly from the Microsoft support site. See Knowledgebase article AID 64745 RSLogix 5000 HELP error Failed to launch Help. No specific testing has been done running RSLogix 5000 in Windows 7 XP mode, although RSLogix 5000 is shown to function correctly.

Disclaimer and Copyright Notice: The information contained in this document is subject to change without notice. UNLESS EXPRESSLY SET FORTH IN A WRITTEN AGREEMENT SIGNED BY AN AUTHORIZED REPRESENTATIVE OF ROCKWELL AUTOMATION, INC. (RA), RA MAKES NO WARRANTY OR REPRESENTATION OF ANY KIND WITH RESPECT TO THE INFORMATION CONTAINED HEREIN, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PURPOSE. RA assumes no responsibility or obligation of any kind for any errors contained herein or in connection with the furnishing, performance, or use of this document. The software described in this document i) is the property of RA or a third party licensor, ii) is furnished only under the RA license that accompanies the software, and iii) may be copied or used only as expressly permitted under the terms of the license. This document is protected by copyright. All rights are reserved. No part of this document may be copied, reproduced, or translated, either mechanically or electronically, without the prior written consent of RA. 2011 Rockwell Automation, Inc. All rights reserved.