Professional Documents
Culture Documents
Contents
Tab window
Image window
Map window
Provide the automatic report on the UEs data and Scanners data.
Support the soft handover event by using the SCANNER data and support the parameter settings.
Contents
y9
Installing Assistant
Start the Assistant software. The system prompts no license. Find that the hardware dongle is operational. Re-install the Assistant software. The problem persists. Check the installation program and find no Sentinel System Drive software. Install the software or un-install the Genex Shared. The problem is cleared.
9 y9
y61891, 2007-6-22
Typical Case 2 Call Drop Because Soft Handover Algorithm Switch Is OFF
Single site verification
Call drop exists when the CS services are verified. Check the DTI scanning RSCP coverage before and after call drop and the Ec/Io distribution in the UE active Strong coverage Before call drop, the Ec/Io in the active set is degraded.
missing neighbor cells? Abnormal interference?
10
Typical Case 2 Call Drop Because Soft Handover Algorithm Switch is OFF
Checking the neighbor
Choose View -> Properties Bar-> WCDMA UE Measurement Bar to view the scrambles in UE active set/monitored set.
From the UE measurement data perspective, the monitored set has samesite 136 and 138 scrambles. The neighbors are normal.
11
Confirming L3 Message
Before the call drop, UE sends 1A event with many 136 and 138 scrambles. Check the measurement control message. The intra-frequency measurement cell includes 136 and 138 scramble cells.
12
13
Typical Case 2 Call Drop Because Soft Handover Algorithm Switch is OFF
Problem location
The network side does not respond to the 1A event reported through the measurement report, or the network problem settings are incorrect.
If the soft handover switch is off, open the switch and perform the test verification. The problem is cleared.
The soft handover switch is off. The problem may be caused by normal reasons, but the problem indicates that the test is not well prepared. The communications with the related engineers are not performed well before the test.
14
The problems found during the single site verification are obvious and easy to process. However, the engineers must be careful and conform to the specifications during the test optimization.
Automatically label the data at the diagram layer
15
Are the time, longitude, and latitude of call drop point inconsistent?
???
16
Call drop point of Assistant 1.2 Call drop point of Assistant 1.3
With the Assistant 1.2 version, in the connected state, if the UE receives the system information, it is regarded as call drop. With Assistant 1.3 version, if the Cell Update succeeds within T1, it is not regarded as call drop. If the Cell Update fails, it is regarded as call drop.
17
DTI_RSCP
18
Check whether the intra-frequency measurement cell of measurement control message includes the target cell before the call drop.
19
20
UE TxPWR
UE transmit power is increased before call drop.
21
Data alignment method 1: Define the time offset of RNC data and Probe data to align the data.
Data alignment method 2: Search the time corresponding to the key signaling to align the data.
22
The UE reports the event 1A of PSC176, and then RNC sends the active set update message and adds PSC176 to active set. The UE reports the event 1D of PSC176 cell, event 1B of PSC192 cell, and then RNC deletes the measurement control. The UE reports the continuously two 1B of 192, and then the RNC delivers the active set update message but deletes the PSC176 cell.
23
Active set is updated. Adding the PSC176 cell is required Analyze the signaling between two ASs, and find that the time difference between two ASs is 11s. During the time difference, the UE does not receive the RL Restore message. According to the RNC configuration, if a radio link is added, the UE does not receive the RL Restore message reported by NodeB within 11 seconds, the uplink is synchronized. It is required to delete the newly added radio link. The link quality of cell 192 is degraded, and the call drop occurs.
Call drop
24
25
SC298 in MS
26
UE_L3 signaling
RNC_L3 signaling
27
28
29
From the perspective of Ec/Io quality of UE active set before and after the call drop, before the call drop, the Ec/Io is degraded fast. After the call drop, the Ec/Io is restored to normal operation.
30
31
32
Monitor set
DTI
UE can correct measure the signals of serving cell and neighbor. The signals in the Monitor Set are better than that in the Active Set.
33
UE does not report and receive the message for about 40 seconds.
34
35
36
Cell SC224 can continuously cover the bridge but the far end signals are weak.
The site survey finds that the cells SC41 and SC42 are blocked by the high buildings, so the cells cannot effectively cover the bridge.
37
Due to the impact of water reflection, the cells in red circle cover a far distance and result in the interference to the bridge. Adjust the antenna azimuth and tilt to optimize the cell coverage area.
38
Huizhou sector 1 coverage after the antenna adjustment Xiti road sector 3 coverage after the antenna adjustment
39
Only the previous two conditions are met. Assistant configures the neighbors.
40
41
42