INSTRUCTION MANUAL
Thank you for purchasing HANYOUNG NUX CO,.Ltd. Product. Please check whether the prouduct you purchased is the exactly same as you ordered. Before using product, please read instruction maunal carefully.

Counter / Timer

HEAD OFFICE

1381-3, Juan-Dong, Nam-Gu Incheon, Korea TEL: (82-32)876-4697 FAX : (82-32)876-4696

Safety Information
Before you use, read safety precautions carefully, and use this product properly. The precautions described in this manual contains important contents related with safety; therefore, please follow the instructions accordingly. The precautions are composed of DANGER, WARNING and CAUTION.

19. Some parts of this product have limited life span, and others are changed by their usage. 20. The warranty period for this product including parts is one year if this product is properly used. 21. When the power is on, the preparation period of contact output is required. In case of use for signals of external interlock circuit, use with a delay relay.

DANGER
Do not touch or contact the input/output terminals because they may cause electric shock.

Model and Suffix code


Model GE Description Digital Batch Counter S(W)96.0 (W)48.0 (W)72.0 (W)72.0 (H)48.0 (H)48.0 (H)36.0 (H)72.0 (L)107.6 (L)84.0 (L)81.0 (L)87.0

WARNING
1. If there is a possibility of an accident caused by errors or malfunctions of this product, install external protection circuit to prevent the accident. 2. This product does not contain an electric switch or fuse, so the user needs to install a separate electric switch or fuse externally. (Fuse rating : 250 V 0.5 A) 3. To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating. 4. To prevent electric shock or devise malfunction of this product, do not supply the power until the wiring is completed. 5. Since this product is not designed with explosion-protective structure, do not use it at any place with flammable or explosive gas. 6. Do not decompose, modify, revise or repair this product. This may cause malfunction, electric shock or fire. 7. Reassemble this product while the power is off. Otherwise, it may cause malfunction or electric shock. 8. It you use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages. 9. Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.

Appearance

GE3 GE4 GE6 GE7 P T


4 6 1 2

Type Digit Stage Power supply

PRESET BATCH TOTAL (Indicator) 4 : 9999 (4 digit) 6 : 999999 (6 digit) 1 stage 2 stage A 100 V - 240 V a.c D 24 V - 60 V d.c Twin timer Support GE3,GE7:Not available

Power Supply

CAUTION
1. The contents of this manual may be changed without prior notification. 2. Before using the product you have purchased, check to make sure that it is exactly what you ordered. 3. Check to make sure that there is no damage or abnormality of the product during delivery. 4. Do not use this product at any place with corrosive(especially noxious gas or ammonia) or flammable gas. 5. Do not use this product at any place with direct vibration or impact. 6. Do not use this product at any place with liquid, oil, medical substances, dust, salt or iron contents. (Pollution level 1 or 2) 7. Do not polish this product with substances such as alcohol or benzene. 8. Do not use this product at any place with excessive induction trouble, static electricity or magnetic noise. 9. Do not use this product at any place with possible thermal accumulation due to direct sunlight or heat radiation. 10. Install this product at place under 2,000m in altitude. 11. When the product gets wet, the inspection is essential because there is danger of an electric leakage or fire. 12. If there is excessive noise from the power supply, using insulating transformer and noise filter is recommended. The noise filter must be attached to a panel grounded, and the wire between the filter output side and power supply terminal must be as short as possible. 13. If gauge cables are twisted closely, the effect on noise may occur. 14. Do not connect anything to the unused terminals. 15. After checking polarity of terminal, connect wires at the correct position. 16. When this product is connected to a panel, use a circuit breaker or switch approved with IEC847-1 or IEC947-3. 17. Install the circuit breaker or switch at near place for convenient use. 18. For the continuous and safe use of this product, the periodical maintenance is recommended. During the first 100 after power input and first 200 after power opening, it is consider as ascend and descend time of internal power and external output power. Therefore, it does not operate during unstable period in order to prevent from malfunction which is caused by unstable output operation of external sensor Supply signal only after 100 Supply power only after 200 following the power input. following the power shutdown.

Dimensions & Panel Cutout


GE7
[Unit : mm]

GE4

GE6

Connection Diagram
NPN Input GE4-P1

GE3

Panel Cutout
a1 a2 L1 L2

GE4

GE6 66.5+0.5 0
32
+0.5 0

GE3

GE7

GE4-P2

45+0.6 0
Same as above

92 +0.5 0
45
+0.5 0

68

+0.7 0

Same as above

More than More than More than More than 130 60 90 82 Same as above More than More than Same as above 57 60

Specification
Model Power voltage Power consumption a.c d.c a.c d.c GE4 GE6 GE3 ) ) 10 10 GE7

GE6-P1

100 - 240 V a.c (50 - 60 24 - 60 V d.c / a.c (50 - 60 Max. 13.5 V a.c Max. 9 VA 11 8

Max. 13.5 V a.c Max. 9 VA 13 10

FND height

Counting speed and input 1 cps / 30 cps / 1 K cps / 10 K cps Contact/Non-contact

Memory for power failure. Input

10 years (Nonvolatile memory) CP1, CP2, RESET, BATCH RESET (exclude TOTAL) 4inputs [H] level 4 - 30 V d.c, [L] level 0 - 2 V d.c Internal pull up/pull down resistance connection due to NPN/PNP setup

Min input Counter External reset Min. input signal range: select among 0.1ms / 1ms / 20 ms signal External output power Timer a.c d.c 1 step 2 step 1 step 2 step Capacity 1c (OUT) START, INHIBIT, RESET Min. input signal range: select either 1ms / 20 ms 12 V d.c ( 5 %) 200 12 V d.c ( 5 %) 100 1a (OUT) 1a (OUT1), 1c (OUT2) NPN 2 points(OUT,BAT.O) NPN 2 points(OUT1,OUT2) Open collector 30 V d.c 100 Stable time: 100 Max. for every 2 Comparative cycle: repeated setup error less than 5 2000 V a.c 50 - 60 Min 100 (Power supply input terminal) (for 1 min period) double amplitude 0.5 X.Y.Z each direction for 10 minutes 100 300 (About 10G) (About 30G) 10 - 55 (for 1 min period) double amplitude 0.5 X.Y.Z each direction for 2 hours for 1 minute pulse per 16ms) 2 Max. Max. 1c (OUT)

GE6-P2

ONE SHOT output Control output contact

0.01-99.99 s [OUT1, OUT2(OUT)]

Capacity NO contact: 250V a.c. 3A resistance load, NC contact: 250V a.c. 2A resistance load

Timer operation Dielectric Strength Insulation Resistance Withstanding noise Vibration Shock Relay Life

Non-contact

stable time when POWER ON (Based on 500 V d.c)

GE3-P1

Square wave noise by noise simulator (1

Malfunction 10 - 55 Durability

Maifunction
Durability Electrical Mechanical

Min. 100 thousand times (250 V a.c 2 A resistance load) Min 1 million times IP65 (Front part only) -20 ~ 65 -10 ~ 55 Max.133 g (Non freezing state) Max.203 g CE Max.203 g , 35 ~ 85 % R.H. (No freezing or decondensation) Max.138 g

Protection structure Ambient temperature Ambient humidity Weight Certificate

If you want to modify Input and output type, plesae contact HANYOUNG sales office

GE3-P2

GE4

GE7 GE7-P1

GE7-P2

Coefficient Input 1(CP1) / Inhibit Input (INHIBIT) Terminal With using counter, it is used as coefficient input or coefficient inhibit Process time become HOLD when timer function is selected Coefficient Input 2(CP2) / Start (START) Terminal With using counter, it is used as coefficient input or coefficient inhibit With using timer, it can be used as SIGNAL ON START, SIGNAL ONE START. (Refer to output mode operation) (SIGNAL ON START: Timer operates only with the continuous input.) (SIGNAL ONE START: Timer operates only with the supply of Input 1 Pulse.) BAT. RESET This is used as BATCH, RESET during the use of counter / timer. RESET This initializes the coefficient value and current time during the use of counter / timer. OUT, OUT2 : This is used as the counter / timer comparative output. BAT.O : Batch Counter Output (1 Stage Setup Type) OUT1(BAT.O): Select between 2 Stage Setup Output and Batch Counter Output (2 Stage Setup Type)

Coefficient display (RED FND) Display coefficient value (counter), time process value (timer), batch coefficient value and setup list. Setup display (GREEN FND) Display setup value (counter), setup time (timer), batch setup value, instant output setup (batch setup is 0 in Timer) and setup contents SET1, SET2 (SET), BAT Indicates the status of coefficient section and setup section (BAT lamp corresponds to batch status.) TIM (Timer) This flashes when the timer progresses and remains lighted when the device stops from inhibit input or reset. (It is indicated in Change Mode of the device during TIM/TTWIN setup.) CNT (Counter) This is indicated during 1CNT/2CNT setup in Change Mode of the device. OUT1, OUT2(OUT), BAT.O (Output Action Indication) BAT.O lights up when the batch setup value is set. (OUT1 Output) BAT.O lights up and outputs when the device operates with the instant output where the batch setup value is 0 (timer). CP1, CP2, RST: Verification of Input Status. (Exclusively for TOTAL) LOCK:Key Lock (KEY LOCK) Action IndicationThis lights up during Lock Setup. This key is for function setup Mode Entry and Mode change. It can also be used for ending after saving when changing the setup value Setup value change Entry and Location shift UP Key RESET KEY When SET, BAT lamp light, RESET key will not operate. Batch and operation mode 1 stage and 2 stage conversion key. When BAT lamp light, it is batch mode and keep operate. Push both of keys together, It operate same as key. DOWN Key TOTAL Model does not have Setup Indication Section, SET1, SET2 and BAT Lamp. OUT1, OUT2, BAT.O change their use as CP1, CP2, RST Input Status Check Lamp. 1 Stage Setup Model does not have SET1 and OUT1 Lamp, and SET2 is displayed as SET and OUT2 is displayed as OUT.

Name of Each Section


GE3

Maximum Coefficient Speed


Maximum coefficient speed is maximum response speed when entering in the duty ratio (ON. OFF ratio) of coefficient input signal as one to one ratio (1:1) As for the input signal below the maximum coefficient speed, if either ON or OFF time is unilaterally less than the standard value of minimum signal width then it may not be counted Minimum Input Time Coefficient Speed Selection Minimum Input Signal
250 11 0.3 0.05

GE6

1 cps 30 cps 1 K cps 10 K cps

Minimum Signal Time refers to ON Time.

Counter Mode Setup Method

Counter input operation mode


A needs value greater than min signal width, B need value greater than half of min signal width.

Counter Function Setup Mode


Setup Items Setup list Input Mode Output Mode Output Time Output Time BATCH OUTPUT Counting speed PRESCALE PRESCALE Decimal Ponit Setup Setup decimal point in display RESET TIME
Memory for power failure Input Logic

Convert Operation Mode to Function Mode -> Press MD key for 2 seconds Contents Initial value

1 Stage setup type 2 Stage setup type

1 Stage setup counter 2 Stage setup counter CP1,CP2 Dual inputs UP mode operatio CP1,CP2 Dual inputs down mode operation Refer to Input operation Mode (Counter) Refer to Output operation Mode (Counter) One short delay time One short time setup No display for level 1 product Set Batch output port Relay or Transistor is set when contact is used with maxmum input speed When using encoder (incremental method). Please use Noice) The input Login of above list is PNP. (D setup is self-maintenance output)

Initial Value set up to 5 decimal points and possible to move up to 4 decimal points Setup decimal point in display and possible to move up to the third decimal point Minimum signal width of external reset signal input Coefficient value is saved when POWER become OFF Coefficient value is initialized when POWER become OFF Vary depends on internal switch conversion Key Lock Cancel Key Lock Do not use any keys (except Do not use , , , key key Do not use front side key)
Flashing Flashing

Counter Output operation of Exclusive Indication (GE-T)


UP
RESET

DOWN

UP/DOWN A,B,C

Key Lock

Set value is first to decrease within Down Mode 6 digits: if -99999(-999), it flashes and does not get counted Within UP MODE, it increases to the maximum display value, initializes to 0 and increases again

Pressing key will return to operation mode without saving. Return to operation mode if there is no key input more than 60 seconds. With function setup mode, it ignores external signal input and maintains output in OFF state. TOTAL product does not display setup lists such as output mode, OUT2 output time, OUT1 output time, BATCH output and etc Level 1 setup product does not display OUT1 output time setup list. Selecting for BATCH output setup will restrict setup function and display function.

Counter Output Action Mode


One Shot Output of OUT1 Output

As for 1 Stage Counter (OUT), it is the same as 2ND Output (OUT2) Action.

Select One Shot Output between 0.01ms~99.99ms One Shot Time Delay Self-Maintenance Output Self-Maintenance Output One Shot Output of OUT2 Output

Post Count Up Action


Coefficient value indication is maintained and setting up HOLD (0) leads to self-maintenance output. Also, setting up time leads to OUT2 output after one shot delay setup. OUT1 and OUT2 become OFF when reset and return to Start.

Coefficient value indication is continuously processed and setting up HOLD (0) leads to self-maintenance output. Also, setting up time leads to OUT2 output after one shot delay setup. OUT1 and OUT2 become OFF when reset and return to Start

Coefficient value indication is continuously processed during START state and OUT2 yields One Shot Output. Self-maintenance output of OUT1 is turned off when OUT2 is turned OFF

Coefficient value indication is maintained during One Shot Time, and then resets. (Repetitive Action)

Coefficient value indication is continuously processed. OUT2 yields one shot output. Self-maintenance output of OUT1 is turned off after one shot time of out2

When coefficient value returns to initial state, then coefficient value indication is maintained for one shot time. After processing one shot time, it displays processed coefficient value.

Coefficient value increases and OUT2 yields One Shot Output. The device is reset after the One Shot Output. (Repetitive Action) Coefficient value is maintained and OUT2 yields one shot output. OUT1 and OUT2 are independent from each other. If #OUT1 is same as setup value of SET1, it leads to one shot output or self-maintenance output. (In case of Level 1 setup type, OUT1 and OUT2 are same each other) # Reset refers to OUT1 and OUT2 become OFF and coefficient value being initialized.

Input Connection
NPN (Non-Voltage Input) Input Logic Selection
Operate the conversion switch after confirming NPN/PNP indication which is displayed on the top Input Method H Non-Contact Sensor Connection Method Contact Sensor Connection Method L NPN Setup Voltage Input PNP O.C PNP Setup Voltage Input PNP O.C

PNP (Voltage Input)

Input Method H L

For receiving Open Collector Input, Input Logic (PNP/NPN) Conversion Switch is embedded internally to Pull up / Pull down the resistance of 4.7 (NPN Setup during shipment) Non-Contact Sensor Connection Method Contact Sensor Connection Method

Input Logic Setup Status can be verified in Function Setup Mode. Internal Impedance is 4.7 , and switches over to Pull Up or Pull Down from NPN/PNP Selection. (Refer to Input Connection) To prevent chattering during the use of Contact Input Counter, setup the coefficient speed at 1 or 30 cps in Function Setup Mode.

Indicated Time Range


Range Selection UP DOWN 4 digits Time Range Decimal System 99.99 s 999.9 s 9999 s 9999 m 9999 h s : second m : minute. h : hour Sexagecimal System 59.99 s 9 m 59.9 s 59 m 59 s 99 h 59 m 99 d 23 h d: day 6 digits Time Range Decimal System 9999.99 s Sexagecimal System 59 m 59.99 s

99999.9 s 9 h 59 m 59.9 s 999999 s 999999 m 999999 h 99 h 59 m 59 s 9999 h 59 m 9999 d 23 h

Timer Mode Setup Method

Output Connection
Example of Non-Contact Output
Connect surge observer (diode,varistor) on the both ends of the load when using inductive load (relay etc.),and must use with GND since the internal circuit and non-contact output are isolated from one another. Calculate power load and load to prevent the non-contact output from exceeding the maximum of 30 V 100

Example of Contact Output


BATCH Output

Avoid the flow of excessive current since it is 250 V a.c NO 3 A (loadresistance) NC 2 A (load resistance), and theconnection must correspond to standard connection method.

Timer Operation Mode


TIM(TIMER)Setup Power RUN / ON delay Signal START / ON delay Signal START / ON delay TTIM(TWIN TIMER)Setup Power RUN ON delay Power RUN OFF delay Signal START ON delay Signal START OFF delay Power ON RUN OFF time For TOTAL Model Power RUN Signal RUN

Function Setup Mode (Timer / Twin timer)


Setup Item Device Change Scale Time range In TIM(TIMER) setup Operation Mode Twin timer is not available with 1 Stage output model. Refer to output operation mode char Contents 1 Stage setup type 2 Stage setup type Initial value Timer Twin Timer

Signal RUN / ON delay Signal RUN / OFF delay Interval / Signal RUN Interval / Signal START Flicker / Signal START Flicker (Counter 0.01sec ~ 999999(9999)h UP/DOWN selectable Flicker (Counter Flicker (Counter Signal Addition Mode) Mode) Mode)

10 (Decimal) / 60 (Sexagesimal)system

In TTIM(TWIN TIMER) setup In Total(Display only)product

CP1/INHIBIT function stops the time. [S.---] is activated when CP2 (START) is ON [S ---] is activated when CP2 is maintained ON, and resets when OFF. [P ---] activates with POWER ON Setup as in order to compensate for interruption of electric power during POWER OFF (Indicates the Memorized Value when electric power is inputted again.)

Output time BATCH Output Input time Memory for power failure Input logic Key Lock

* One short or self-maintenance for OUT2(OUT)

* No display for Total and TWIN TIMER mode Set Batch output port :Relay : Transistor) Minimum input time selection 1 /20 (INHIBIT), (START), RESET Current time and Batch count value are saved when power failure Remove a data when power failure

Timer[TIM]Output Operation
1 Stage Setup Type Output is OUT. INHIBIT (CP1) temporarily stops the time.

Power RUN / ON delay

NPN Input PNP Input

Convertible by dip switch It is not available to change setup in power input menu. Key Lock No use for all keys ( key exception) No use keys

Key lock setup in operation condition (4stages)

, No use

, keys

Total(Indicator) type of product does not have setup mode for output time and Batch One stage output mode does not have twin timer function

Runs when POWER ON When Reset signal is authorized, process value initializes and runs.

Signal START / ON delay

Interval / Signal START

Run when START (CP2) is ON within the initial setup value When setup time exceeds, display value will maintain and output (one short output with setting).

Runs when START (CP2) is ON. Output is ON during the set time, and the indicated value is initialized and output is OFF when the set time elapses.

Signal START / ON delay (Counter F output mode operation) - RUN when initial setup value of START (CP2) is ON - When setup time exceeds, display value will increase and put out the output (one short output with Setting

Flicker / Signal START

Signal RUN / ON delay

Run when CP2 (START) is ON within the initial setup value and when OFF, it RESET When setup time exceeds, it maintains display value and output time

[HOLD] Setup (when output time [OUTT] is set at 0[HOLD]) Setup Set Time in Run Mode Maintains the indication of initial value when Power is ON Runs when becomes START (CP2). ON/OFF Repetitious Action of control output after reaching the Set Time. Initializes and stops when Reset is ON ONE SHOT TIME Setup (when output time [OUTT] is set at more than 1) Setup Set2 Time in Run Mode. Maintains the indication of initial value when Power is ON Runs when Power is ON One Shot Output after reaching the Set Time. Initializes and stops when Reset is ON Flicker / Signal START Same operation as counter output mode

Signal RUN / OFF delay

Signal Addition

When START (CP2) is ON then output become ON and time will display initial value. Time activates the initial value to run when START (CP2) is OFF. The initial value is initialized and output is OFF when the set time elapses.

Interval / Signal RUN


RUN when START (CP2) maintains ON and it will become HOLD when it is OFF (cumulative Timer Function) No output operation within Down time range

Twin Timer[TTIM]Output Action


Power RUN - ON delay
Runs when START (CP2) is ON and resets when OFF Output is ONduring the set time, and the initial value is initialized and output is OFF when the set time elapses. Runs when Power is ON OFF Output for T1 Time / ON for T2 Time. Repetition Initializes and stops when Reset is ON

Power RUN - ON delay


Runs when Power is ON ON Output for T1 Time / OFF for T2 Time. Repetition Initializes and stops when Reset is ON

Signal RUN

Runs when START (CP2) is ON, and resets when START (CP2) is OFF Set Time is first to be reduced during Down Mode Setup.

Signal START - ON delay


Maintains the indication of initial value when Power is ON Run when there is START (CP2) input OFF Output for SET1 Time / ON for SET2 Time. Repetition Initializes and stops when Reset is ON

Batch Counter

Signal START - ON delay


Maintains the indication of initial value when Power is ON Runs with the input of Start (CP2) Output ON for SET1 time/repeat OFF for SET 2 times Initializes and stops when Reset isON

Batch Counting & Output Action


Batch counting value continues to increase until Batch Reset is authorized. When batch coefficient value exceeds 999999 (4 rows 9999), it initializes to 0 and display In case of batch display state (BAT lamp is lighted), press the the front section to reset the batch value. Even in the batch display state, counter/timer action operates normally. Batch coefficient increases at the output of OUT2 (OUT). Batch output is outputted as (BAT.O). (BAT.O lamp is lighted) key on

Power RUN / OFF time


Individual output control and setup pauce time RUN when power is ON Output OUT1 during SET1 time and OUT1 OFF during pause time Output OUT2 during SET2 time and OUT2 OFF during pause time and operations repeated

Instant Output Setup


Function switches over to instant output when the batch value is set at 0. (BAT.O lamp is lighted)

Batch Counter setup Method


1. Press / key key (When use want to set 100 batch.) key will complete setup. (Pressing key will exit without Enter to setup state, 6 rows (4rows) FND flickers, set "100" by pressing 2. Pressing changing) 3. Pressing key will return to operation mode. (Left side BAT lamp off) , BAT setting. Properly operates within BATCH display mode Possible to setup BAT only with

t: Possible to set up from 0 to 99.99 sec with pause time

setting

Timer Action of Exclusive Indication (GE-T)


OFF set is available for up time range of Decimal system.(Press second) key for 2

Power RUN

Runs after initializing the process value upon the authorization of Run Reset Signal when Power is ON Set Time is first to be reduced during Down Mode Setup.