The document compares the technical specifications of lighting poles that meet the requirements of the Ministry of Energy (MOE) Specification No. D22 versus poles coated with Galva Coat. For poles that meet the MOE D22 specification, the bending stress value exceeds the maximum allowable stress, resulting in failure. In contrast, the bending stress value for poles coated with Galva Coat is below the maximum allowable stress, resulting in passing the requirements.
The document compares the technical specifications of lighting poles that meet the requirements of the Ministry of Energy (MOE) Specification No. D22 versus poles coated with Galva Coat. For poles that meet the MOE D22 specification, the bending stress value exceeds the maximum allowable stress, resulting in failure. In contrast, the bending stress value for poles coated with Galva Coat is below the maximum allowable stress, resulting in passing the requirements.
Copyright:
Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOCX, PDF, TXT or read online from Scribd
The document compares the technical specifications of lighting poles that meet the requirements of the Ministry of Energy (MOE) Specification No. D22 versus poles coated with Galva Coat. For poles that meet the MOE D22 specification, the bending stress value exceeds the maximum allowable stress, resulting in failure. In contrast, the bending stress value for poles coated with Galva Coat is below the maximum allowable stress, resulting in passing the requirements.
Copyright:
Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOCX, PDF, TXT or read online from Scribd
GALVA COAT for GALVANIZING & LIGHTING POLES COMPARISON TABLE BETWEEN MOE SPECIFICATION NO.
D22 & GALVA COAT SPECIFICATION
TECCHNICAL SPECS Pole height (m) Top Diameter/Across flat (mm) Bottom Diameter/Across flat (mm) Cross section Thickness (mm) Material grade Type of pole Wind speed Wind pressure =0.613x392 Loading code Integrity code Point load Load case Bending moment (kn.m) Maximum stress (Mpa) Maximum allowable stress as per specs D- 22 table 4-a (Kgf/mm2) Result for bending stress values Maximum usage % AS PER MOE SPECS NO. D22 9m+2m(embedded) 114 165 Circular 5.5 ST52-3 to DIN 17100 Stepped pole 39m/s 1000 pa ASCE 74 ASCE /SEI 48-05 285kg = 2800 N Pp = 1.5x 2800 N 40.84 384 20.8=20.8x9.81=204Mpa 384>>204 then FAIL 108 > 100 then FAIL GALVA COAT PROPOSAL 9m+2m(embedded) 150 300 octagonal 4 ST52-3 to DIN 17100 Single piece tapered pole 39m/s 1000 pa ASCE 74 ASCE /SEI 48-05 285kg = 2800 N Pp = 1.5x 2800 N 49.22 198 20.8=20.8x9.81=204Mpa 198<204 then PASS 55.8<100 then PASS
Sr. No. Tag No. Descriptio N Motor Rating / Load (Kw) Motor Terminal Power Mt=Bkw /Motor Effi. (%) Motor Effi. (%) P.F. (Cosθ) Type Of Starter Service Voltage (V)