RBS 2116V2 CONFIGURATIONS

1 The main units of RBS 2116v2 y y y y y y DXU DRU BFU PSU Y- LINK DC\DC CONVERTER FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB

TXB

TXB

TXB

TXB

TXB

FOR 6P AMM

N E DCCU ACCU

L1 L2 L3

RBS 2116V2 CONFIGURATIONS


1 DUAL BAND CONFIGURATION: (2+2+2)/900 AND (2+2+2)\1800 FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB Cell A 900

TXB Cell A 1800

TXB Cell B 900

TXB Cell B 1800

TXB Cell c 900

TXB Cell C 1800

FOR 6P AMM

N E DCCU ACCU

L1 L2 L3

You must be sure uncombined led is ON in DRU if it is OFF remove uncom\com card and put it in correct position.

RBS 2116V2 CONFIGURATIONS

(4+4+4) uncombined configuration. 900 or 1800


FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB CELL A

TXB

TXB

TXB CELL B FOR 6P AMM

TXB

TXB CELL C

N E DCCU ACCU

L1 L2 L3

You must be sure uncombined led is ON in DRU if it is OFF remove uncom\com card and put it in correct position.

RBS 2116V2 CONFIGURATIONS

(4 + 4+ 4) HYBIRD COMBINED CONFIGURATION 900 OR 1800


FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB CELL A

TXB

TXB CELL B FOR 6P AMM

TXB

TXB CELL C

TXB

N E DCCU ACCU

L1 L2 L3

UNCOM led must be off if it is on remove uncom\com card from DTR and put the correct position.

RBS 2116V2 CONFIGURATIONS

(6 TRX CONFIGURATION HYBIRD COMBINED)


FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB

TXB CELL A 3 FEEDERS

TXB

TXB

TXB

TXB

FOR 6P AMM

N E DCCU ACCU

L1 L2 L3

UNCOM led must be off if it is on remove uncom\com card from DTR and put the correct position.

RBS 2116V2 CONFIGURATIONS 8 TRX CONFIGURATION HYBIRD COMBINED


FAN UNIT DC TO DC CON DC TO DC CON DUMMY DUMMY DXU FOR FOR TMA TMA PSU PSU PSU PSU

BFU

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXA DRU y-link

TXB

TXB

TXB

TXB

TXB

TXB

CELL A 4 FEEDERS

FOR 6P AMM

N E DCCU ACCU

L1 L2 L3

UNCOM led must be off if it is on remove uncom\com card from DTR and put the correct position.

RBS 2116V2 CONFIGURATIONS

You might also like