Cynoprobe Menu Settings

Stream Setup
Enabled Lines: Remote Stream Select: Enabled Line 1: Line 2: Line 3: CN WAD CN(T)

(Next ...) Flushing: Measurement Cell Flushing: Flushes between Stream: Same Stream Flushes: Filter Flushing: Measuring Cycles:

3 1

Note: 0 = OFF

(Next ...) Filtrate Bypass Normal Bypass (s) 0 0 0 After Filter Flushing (s): 0 0 0

1: 2: 3:

(Next ...) Duty Cycle: No. 1: No. 2: No. 3: No. 4: No. 5:

0 0 0 0 0

No. 6: No. 7: No. 8: No. 9: No. 10:

0 0 0 0 0

(Next ...) Pump Combinations: None: 1: 2: 3: Remote Pump

Trends

Timers
Timers 1 Min Cycle time: WAD Cycle: Titration Cycle: Auto Reset: Max Filling Time: 0 0 0 1 300 min s (0) s (0) min s

(Next ...) Timers 2 Time to Temp SP: Settle Time: Meas Time: Drain Time Level Sensor:

300 5 60 10 0

s s s s

(Next ...) Timers 3: Filter Flush: Auto Clean: Pre-Fill Bypass: Clean Time: Stripping

0 24 5 120 0

s h s s

(Next ...) Timers 4: LEX Dosing: AUX Dosing LEX Reaction: AUX Reaction: AgNO3 Reaction:

5 0 3 0 10000

s s s s ms

Calibration:
Calibration 1 m: c: 59.45 -483.73

NACN Calibration

(Next ...) Titration 1 Cell Volume Cycle Volume AgNO3 Staich Factor K

0.088 0.100 0.130 52 0

litre ml mol/litre

(Next ...) Titration 2 End Point Gradient End Point Counts Maximum Cycles

25 -900 200

Temperature
(Settings ...) Temperature Settings Temp Setpoint: Temperature Compensation Term A Term B Term C 25 0.000131 0.012494 0.605773

Cleaning
(Settings ...) General Cleaning Settings: Cleaning Time: H2O2 and HCL Cleaning Enable Auto Clean: Clean Interval: Post Clean Measure: 120

24 3

hours

(Next ...) HCL Flushing Stripping Time: Measuring Cycles: Post Clean Measure: Post Clean Flushing Reverse Current

0 0 3 3

s Note: 0 = OFF

Dosing
(Settings ...) LEX Dosing LEX Dilution Factor: Factor usage 0.977

None: CNWAD:

(Next ...) Aux Dosing- Usage Off 1: 2: 3:

Dosing

1 x Dilute

n x Dilute

(Next ...) Aux Dosing- Continued Dose Times Line 1: 0 Line 2: 0 Line 3: 0

Dilution Factor 0.000 0.000 0.000

(Next ...) AgNO3 Dosing Pump Usage: AUX Pump LEX Pump

Current Loops
Output Assignments: CN Line 1: 1 Line 2: 2 Line 3: 0 WAD 5 6 0 CN(T) 0 0 0 pH 3 4 0

(Next ...) Scaling: CN 1: CN 2: CN 3: 4mA 0 0 0 20mA 300 300 300

(Next ...) Scaling: pH: 4mA 0 20mA 14

(Next ...) Outputs 1 - 4 AO 1 2 3 4

Tuning-4mA Tuning-20mA 6 260 31 240 6 260 31 240 6 270 31 240 6 260 31 240

(Next ...) Outputs 5 - 8 AO 5 6 7 8

Tuning-4mA Tuning-20mA 6 260 31 240 6 260 31 240 6 260 31 240 6 260 31 240

SMS
Enabled

pH
(Settings ...) pH Measure in last flush: Measuring Time:

10

Filters
Filter Times (s): Counts: pH: Filtrate Temperature: 2 2 1

Faults
Faults: Enabled Hose burst detection: Leak detection: Signal Relays: NO: NC:

About Cynoprobe
Panel Version: PLC Version: 3.02.11 3.02.11

(Setup ...) Cynoprobe Setup 2nd Line: 3rd Line: WAD Unit: Titration Unit