Professional Documents
Culture Documents
2004
73 Convenient Locations
MAINE
Augusta 04330
138 Leighton Road
P.O. Box 5008
207.623.2521
800.322.4700
Fax: 207.622.2533
Bangor 04401
67 Target Industrial Circle
207.947.6905
800.432.7371 ME only
Fax: 207.947.8211
Biddeford 04005
22 Landry Street
207.282.7558
800.443.0505
Fax: 207.282.0299
Caribou 04736
420 Main Street
207.498.2526
800.339.3029
Fax: 207.498.2137
Ellsworth 04605
9 Buttermilk Road
207.667.9322
888.882.9322
Fax: 207.664.0201
Lewiston 04240
9 Forrestall Street
P.O. Box 2546
207.784.4575
800.252.2000
Fax: 207.784.4205
S. Portland 04106
150 Postal Service Way
207.772.8364
800.482.0791 ME only
Fax: 207.773.4571
Rockland 04841
22 Merrill Drive
207.594.6200
800.287.0015
Fax: 207.594.9185
West Bath 04530
P.O. Box 612
Bull Rock Bridge Road
207.442.7990
800.427.7990
Fax: 207.442.8377
Winslow 04901
Mail to: P.O. Box 1569
Waterville, ME 04903
Ship to: 37 Heywood Rd.
Winslow, ME 04901
800.533.1172
F. W. Webb
207.872.5522
800.640.9322
Fax: 207.872.8207
Kennebec Supply
207.873.2111
Fax: 207.873.0152
Kentrol / Sevco
207.873.7741
800.452.1928
Fax: 207.873.2945
Webb Pump
207.873.7741
800.452.1928
Fax: 207.873.2945
MASSACHUSETTS
Auburn 01501
43 Sword Street
Auburn Industrial Park
508.757.9322
800.872.0211
Fax: 508.757.8981
Bedford 01730
160 Middlesex Turnpike
781.273.9322
800.221.9322
Fax: 781.270.0208
Bellingham 02019
37 South Maple Street
508.966.4999
Fax: 508.966.1999
Boston 02118
237 Albany Street
617.482.8387
Fax: 617.423.7858
Brockton 02301
60 Industrial Boulevard
508.580.8310
800.544.9322
Fax: 508.584.6418
Canton 02021
152 Will Drive
781.828.5559
Fax: 781.828.8060
Dedham 02026
45 Commerce Way
781.329.6200
866.684.9322
Fax: 781.329.3531
Fitchburg 01420
135 Falulah Street
978.345.4121
800.322.0899
Fax: 978.343.3749
Gloucester 01930
51 Great Republic Dr.
Blackburn Industrial Pk
978.283.7800
Fax: 978.281.7016
Greenfeld 01301
340 Chapman Street
413.773.3644
800.564.3644
Fax: 413.773.8205
Haverhill 01835
270 Neck Road
Ward Hill Business
Park West
978.374.8448
800.521.7499
Fax: 978.373.7723
Hingham 02043
45 Pond Park Road
781.749.9322
Fax: 781.740.4652
Hyannis 02601
108 Breeds Hill Road
508.775.3890
800.352.3159 MA only
Fax: 508.778.0409
Lowell 01851
180 Olde Canal Drive
978.937.9322
800.642.9322
Fax: 978.937.5522
Malden 02148
580.584 Broadway
781.322.7111
800.963.7111
Fax: 781.324.7773
Methuen 01844
98 Lindbergh Avenue
781.325.7041
866.548.9322
Fax: 781.325.7051
Utilities Supply Co. (USCO)
781.395.9023
800.343.7555
Fax: 781.395.2329
New Bedford 02745
915 Church Street
508.995.9533
888.354.0048
Fax: 508.985.0934
Northampton 01060
135 Industrial Drive
413.586.8100
800.282.7721 MA only
Fax: 413.586.6280
Pittsfeld 01201
35 Commercial Street
413.448.8205
800.578.9322
Fax: 413.442.2251
Plymouth 02360
3 Collins Avenue
508.830.4666
Fax: 508.830.0481
Salem 01970
295 Bridge Street
978.744.6550
800.345.5025
Fax: 978.744.1444
Springfeld 01104
153 Plaineld Street
413.781.1700
800.660.3141
Fax: 413.781.1705
Sturbridge 01566
Pipe Depot
9 Picker Road
508.347.3342
Fax: 508.347.4967
Woburn 01801
50 Everberg Road
781.933.1804
800.253.7838
Fax: 781.933.3528
HVAC Controls
781.933.1804
800.341.0110
Fax: 781.933.3528
NEW HAMPSHIRE
Concord 03301
46 Henniker Street
603.223.6580
888.508.0050
Fax: 603.223.6585
Dover 03820
10 Sumner Drive
603.749.3100
800.582.7196
Fax: 603.749.5572
Exeter 03833
18 Continental Drive
603.772.3441
888.993.9322
Fax: 603.772.1866
Gilford 03249
302 Hounsell Avenue
603.524.9322
800.345.1771
Fax: 603.527.1554
Keene 03431
420 Winchester Street
603.357.1877
800 235.1218 NH only
Fax: 603.357.7276
Lebanon 03766
55 Etna Road
603.448.1980
800.322.8707
Fax: 603.448.6057
Madison 03849
1173 Conway Road
603.367.8852
800.852.9203
Fax: 603.367.4647
Manchester 03103
25 Union Street
603.668.6488
800.789.6488
Fax: 603.668.7277
Nashua 03062
7 Redmond Street
603.883.3355
800.462.1440 NH only
Fax: 603.595.7733
RHODE ISLAND
Cranston 02920
3 Slater Road
Pipe, Valves, Fittings
401.463.3741
800.795.6390
Fax: 401.463.4103
Webb Pump
Webb Piping Products
401.463.4108
866.850.7867
Fax: 401.463.6056
Webb BioPharm
401.463.4176
877.932.2246
Fax: 401.463.4160
Warwick 02888
101 Jefferson Blvd.
401.463.8339
888.225.6850
Fax: 401.463.8661
CONNECTICUT
Franklin 06254
182 Route 32
860.642.9081
888.642.9086
Fax: 860.642.9082
Hartford 06114
150 Locust Street
860.522.9322
800.252.9322
Fax: 860.246.3718
Hartford 06114
Victor
200 Locust Street
860.722.2433
800.243.9360
Fax: 800.274.2004
New Haven 06519
650 Ella T. Grasso Blvd.
203.865.6124
866.416.9322
Fax: 203.624.5027
Waterbury 06708
737 Bank Street
203.574.5959
800.572.6479
Fax: 203.753.2245
VERMONT
Barre 05641
10 Clark Road
802.479.3373
800.244.5044 VT only
Fax: 802.479.2932
Bennington 05201
240 East Road
802.447.2312
800.821.9506
Fax: 802.447.1481
Brattleboro 05301
231 John Seitz Dr.
Exit 1 Industrial Park
802.257.4316
800.821.9511
Fax: 802.257.7690
Rutland 05701
3091 Cold River Road
802.775.1922
800.622.4365
Fax: 802.773.7044
Springfeld 05156
3 Charlestown Road
802.885.8127
800.872.5303
Fax: 802.885.2685
St. Albans 05478
5 Franklin Park West
802.527.0531
800.696.3763
Fax: 802.524.2093
St. Johnsbury 05819
2409 Portland Street
802.748.8101
800.872.8028
Fax: 802.748.3478
Williston 05495
80 Park Avenue
802.879.5155
800.696.0340
Fax: 802.879.4848
NEW YORK
Albany 12204
17 Erie Boulevard
518.472.9322
800.432.9322
Fax: 518.472.9399
Binghamton 13904
62 Griswold Street
607.724.3170
888.593.9322
Fax: 607.724.4369
Cazenovia 13035
Kentrol/Sevco Control
Equipment Corp. (CEC)
Mail to: PO Box 330
Ship to: One Carriage
Place Lane
315.655.9700
Fax: 315.655.9701
Canandaigua 14424
5297 Parkside Drive
Suite 425
585.393.9322
800.828.8824
Fax: 585-393-6500
Newburgh 12550-6405
600 Corporate Blvd.
845.567.0242
877.494.9322
Fax: 845.567.6019
Plattsburgh 12901
7327 Rte 9
518.562.2575
800.622.9322
Fax: 518.562.0117
Queensbury 12804
3 Highland Avenue
518.792.1316
800.826.0326
Fax: 518.792.1335
Syracuse 13211
6792 Townline Road
315.476.9322
800.262.9222
Fax: 315.472.4139
Utica 13501
415 Broad Street
315.724.3191
Fax: 315.724.4067
Victor is in no way responsible for errors, omissions or typos in the Heating Catalog. Further-
more, the pictures, ads and editorials contained in the Heating Catalog are copyrighted and
cannot be used in full or any part without express permission of the publisher.
Easy Ordering
ORDER ONLINE at: victormfg.com
Charge to your account, or we accept MasterCard, VISA and
Business American Express.
To our Valued Customers,
We are pleased to bring you our 2011 Heating products catalog. If
youve used our catalogs in the past, youll notice that something has
changed with this edition. Weve bundled our traditional heating cata-
log and our Victor gas catalog providing you with an easy to use, single
source for all your Oil, Natural and LP Gas product needs. Inside youll
fnd hundreds of product pictures, descriptions, specifcations, and
Webb part numbers as well as a wealth of technical and cross reference
info. The numbers, when used with our WebbConnect online ordering
system, will give you inventory status, pricing and ordering capability,
all with a click of the mouse.
With over 70 locations throughout New England and New York, you
are never far from the products in this catalog. And, of course, we offer
free delivery if that best suits your needs. All of our locations are listed
to the left for easy reference. Please dont hesitate to call the location
most convenient to you for help at any time. Need to speak to an LP
Specialist at Victor? Simply call 800-243-9360.
Sincerely,
Jeff Pope
President
F.W. Webb Company
GAS EQUIPMENT
Victor is the Northeasts leading distributor of these premier gas equipment
manufacturers.
continued 4
Section Page
1 Regulators & Accessories 1
Regulators, Regulator Reliefs, Pigtails, POL Fittings
2 Valves & Accessories 30
Cylinder and Service Valves, Multivalve Assemblies,
Pressure Relief Valves & Relief Valve Manifolds, Globe & Angle Valves,
Ball Valves, Excess Flow Valves, Filler Valves, Vapor Equalizing Valves,
Internal Valves & Accessories, Adapters, Connectors & Fittings,
Miscellaneous Equipment, Diagrams, Repair Kits
3 Meters/Meter Accessories 86
Meters, Meters Bars, Manifolds, Accessories
4 Cylinders, Tanks & Accessories 90
ASME & Dot Cylinders, Motor Fuel Cylinders, Cylinder Cabinets,
Cylinder Inverters, Scales, OPD Tools, Hand Trucks, ASME Tanks,
ASME Replacement Parts, CAD Welding & Galvanic Protection
5 Paint & Supplies 102
Tank Paint & Supplies, Decals & Signs
6 Gauges 107
Cylinder Gauges, Tank Gauges, Pressure Gauges
7 Gas Pipe, Tubing & Fittings 118
TracPipe, Counter Strike, Copper Tubing, Coated Copper Tubing,
Underground PE Pipe, Bulk Hose, Sediment Traps, Lyco Fittings,
Continental Fittings, Dormont Connectors, SAE Fittings,
Barbed Hose Fittings, Black Iron Fittings, Forged Steel Fittings
GAS EQUIPMENT CATALOG
Table of Contents
8 Gas Heating 149
Ignition Modules, Ignitors, Water Heater Controls, Gas Valves,
Retrot Kits, Water Safety Valves, Thermocouple & Thermopiles,
Gas Orices, Aluminum Tubing, Pilots, Hot Surface Igniters,
Gas Valves Pressure Regulators
9 Pumps/Compressors 174
Positive Displacement Meters, Hose Reels, Flex Connectors, Strainers,
Swivel Connectors, Compressor Kits, Pump Station Kits, Propane Pumps,
Selection Tables, Bypass Valves, Motors, Repair Parts
10 Miscellaneous Equipment 205
Gas Conversion Burners, Vaporizers, Gas Lights, Gas Outlet Boxes
11 Tools & Chemicals 211
Electrical Meters & Testers, Thermometers, Leak Detectors,
Pressure Detectors, Carbon Monoxide Detectors,
Underground Pipe Locators, Vacuum Cleaners, Gloves, Hand Tools,
Power Tools, Flashlights, Lubricants, Chemicals, Test Kits
13 Appendices 213
Index i
Section Page
GAS EQUIPMENT CATALOG
Table of Contents (continued)
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
1
1
SECTION
Regulators
Compact High Pressure
First Stage Regulator
Ideal for use as a frst stage regulator on any domestic size ASME or DOT container in propane
gas installations requiring no more than 1,500,000 BTUs/hr. These regulators are factory set to
reduce tank pressure to an intermediate pressure of approximately 10 PSIG.
High Pressure First Stage Regulators
LV4403 Series
Provides accurate frst stage regulation in two-stage bulk tank systems. These regulators
handle vaporization of tanks up to 1200 gallons. Reduce tank pressure to an intermediate
pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like
industrial furnaces or boilers. Also incorporated in multiple cylinder installations.
Second Stage Regulator
for 2 PSIG Systems
LV4403Y & LV5503Y Series
Designed to reduce frst stage pressure of 10 PSIG down to 2 PSIG. Systems that utilize
this regulator use smaller than normal piping inside of the building. A special fnal stage
regulator, not the appliance regulator, is required to reduce this intermediate 2 PSIG
pressure down to 11 w.c.
LV3403TR
* Maximum fow based on 15 PSIG inlet pressure and 8 PSIG delivery.
* when used for fnal stage pressure control, must either incorporate integral relief valve or separate relief valve should be specifed in
accordance with NFPA Pamphlet 58.
** Maximum fow based on inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting.
LV4403Y4
LV4403TR9
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
BONNET
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE* WEBB#
LV3403TR 1/4 F. NPT 1/2 F. NPT 1/4 10 PSIG Over Outlet 1,500,000 162774
* Backmount Design
** Maximum fow based on 10 PSIG inlet pressure and 2 PSIG delivery pressure.
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
ADJUSTMENT
RANGE
BONNET
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE** WEBB#
LV4403Y4 1/2 F. NPT 1/2 F. NPT 1/4
2 PSIG at 10
PSIG Inlet
Over Inlet 1,000,000 192612
LV4403Y46R* 1/2 F. NPT 3/4 F. NPT 1/4
2 PSIG at 10
PSIG Inlet
Over Inlet 1,000,000 250285
LV5503Y6 3/4 F. NPT 3/4 F. NPT 1/4
2 PSIG at 10
PSIG Inlet
Over Inlet 2,200,000 250286
LV5503Y8 3/4 F. NPT 1 F. NPT 9/32
2 PSIG at 10
PSIG Inlet
Over Inlet 2,200,000 250287
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE*
(PSIG)
INTEGRAL
RELIEF
INCLUDED
VAPOR
CAPACITY
BTU/HR.
PROPANE** WEBB#
LV4403SR4
1/2 F. NPT
1/2 F. NPT
1/4
5 1-5
Yes 2,500,000
187108
LV4403TR4 10 5-10 187110
LV4403SR9
F. POL
5 1-5 162780
LV4403TR9 10 5-10 162781
LV4403SR96
3/4 F. NPT
5 1-5 187109
LV4403TR96 10 5-10 162782
2
victormfg.com
1
SECTION
Gas Equipment Catalog
Regulators
Large Low Pressure
Second Stage Regulators
Designed to reduce frst stage pressure of 5 to 20 PSIG down to burner pressure.
Ideal for larger commercial and industrial applications, multiple cylinder installations
and large domestic systems.
Low Pressure Second Stage Regulators
Designed to reduce frst stage pressure of 5 to 20 PSIG down to burner pressure,
normally 11 w.c. Ideal for medium commercial installation, multiple cylinder installations
and normal domestic loads.
MFR#
INLET
CONNECTION
OUTLET
CONNECTION ORIFICE SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
BONNET
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE WEBB#
LV5503B4 1/2 F. NPT
3/4 F. NPT 1/4
11 W.C. at
10 PSIG Inlet
9 to 13 W.C. Over Inlet
1,600,000
162783
LV5503B6
3/4 F. NPT
162784
LV5503B8 1 F. NPT 9/32 2,300,000 187111
LV6503B14 11/2 F. NPT 11/2 F. NPT
5/8 81/2 to 14 W.C.
8,000,000 241847
LV6503B16 2 F. NPT 2 F. NPT 9,750,000 243018
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
BONNET
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE WEBB#
LV5503G4 1/2 F. NPT 3/4 F. NPT 1/4
15 W.C. at
15 PSIG Inlet
8 to 18 W.C. Above Inlet 1,750,000 193313
MFR#
INLET
CONNECTION
OUTLET
CONNECTION ORIFICE SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE WEBB#
LV4403B4
1/2 F. NPT
1/2 F. NPT
#28 Drill
1 W.C. at 10
PSIG Inlet
9 to 13 W.C. Over Inlet
935,000
162775
LV4403B46
3/4 F. NPT
162776
LV4403B46R* 162777
LV4403B66
3/4 F. NPT
162778
LV4403B66R* 162779
LV4403B66RA**
1,000,000
262352
LV4403B66RAB*** 262353
*Backmount Design. **90 Body. ***90 Body with Brackett.
Low Pressure Second Stage
Tobacco Barn Regulator
Especially developed for drying barns in the tobacco industry. The LV5503G regulator
will supply steady and constant fow of fuel to as many as 12 to 20 burners throughout the
barn.
LV4403B66R
LV5503B4
LV5503G4
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
3
1
SECTION
Regulators
Compact Twin Stage Regulators
This compact two-stage regulator is designed to reduce container pressure down to 11 w.c.
or 2 psi delivery pressure. It is ideal for on-site cylinder applications, mobile homes and
average domestic service including small ASME and 100 to 420 pound DOT cylinders.
LV404B4
Compact Twin Stage Regulators
The compact twin-stage regulator is designed to reduce container pressure down to 11 w.c.
delivery pressure. It is ideal for on site container applications such as homes, mobile homes
and cottages for average domestic service; including small ASME tanks and 100-420 pound
DOT cylinders.
LV404B34 LV404B39
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
2ND STAGE
BONNET
VENT
POSITION
1ST
STAGE
BONNET
VENT
POSITION
2ND
STAGE
CAPACITY
BTU/HR.
PROPANE**
ACCES-
SORIES
1ST STAGE
VENT
PIPE-AWAY WEBB#
LV404B4
1/4 F. NPT
1/2 F. NPT
.219
11 W.C. at
100 PSIG
Inlet
9 to 13 W.C.
Down Over Outlet
525,000
404PE
162787
LV404B4V9 9 oclock 9 oclock 162788
LV404B46 3/4 F. NPT Down Over Outlet 162789
LV404B9
F. POL
1/2 F. NPT
Down Over Outlet 187105
LV404B9V9 9 oclock 9 oclock 214088
LV404B96 3/4 F. NPT Down Over Outlet 187106
LV404Y9 1/2 F. NPT 2 PSI 1.8 to 2.5 PSI Down Over Outlet 800,000 359411
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
2ND STAGE
BONNET
VENT
POSITION
1ST
STAGE
BONNET
VENT
POSITION
2ND
STAGE
CAPACITY
BTU/HR.
PROPANE**
ACCESSORIES
WEBB#
1ST
STAGE
VENT
PIPE-
AWAY
2ND
STAGE
VINYL
COVER BRACKET
LV404B34 1/4 F. NPT
1/2 F. NPT .100
11 W.C. at
100 PSIG
Inlet
9 to 13 W.C.
Rear Over Outlet
450,000 404PE 2302-55 2302-31
162785
LV404B39 F. POL 191088
LV404B34V9 1/4 F. NPT
Left 9 oclock
162786
LV404B39V9 F. POL 202171
Twin Stage Automatic
Changeover Regulators
These combination automatic changeover, two stage regulators are especially suitable for
homes, mobile homes, cottages, construction and other portable two cylinder installations.
Empty containers may be replaced without interrupting customers gas service.
7525B
MFR#
SERVICE &
RESERVE
INDICATOR
INLET
CONNECTIONS
OUTLET
CONNECTIONS
FACTORY
DELIVERY
PRESSURE*
ADJUSTMENT
RANGE
BONNET
VENT
POSITION
BRACKET
INCLUDED
CAPACITY
BTU/HR.
PROPANE** WEBB#
7525B23
Integral 1/4 Inverted Flare 1/2 F. NPT 11 W.C. 9 to 13 W.C. Over Outlet
2302-31 200,000 162790
7525B4 2503-22A 450,000 162792
* Set at 100 PSIG inlet pressure.
** Maximum fow based on 25 PSIG inlet pressure and 9 water column delivery pressure.
4
victormfg.com
1
SECTION
Gas Equipment Catalog
Regulators
302
302V
Compact Regulators
These compact regulators are designed for smaller outdoor grills and fsh cookers. It is
intended for use on small portable appliances that use 100,000 BTUs/hr. or less. It may not
be used on fxed pipe systems per NFPA 58, 1995 edition.
Automatic Changeover Regulator Outfts
These outfts contain the equipment required to provide automatic changeover regulation.
7523B4
7523B23
MFR# TYPE
INLET
CONNECTION
OUTLET
CONNECTION
ORIFICE
SIZE
FACTORY
DELIVERY
PRESSURE
ADJUSTMENT
RANGE
BONNET
VENT
POSITION
VAPOR
CAPACITY
BTU/HR.
PROPANE WEBB#
302
Single Stage
1/4 F. NPT
3/8 F. NPT
No. 50
Drill
11 W.C. at
100 PSIG
Inlet
9 to 13 W.C.
Small Vent
Above Inlet
125,000
86837
302V9
Drip Lip at
9 oclock
273820
302V9LS
Soft POL
Without Orifice
162715
302V9 Hard Nose
9 oclock Vent
273820
302VW Vent Port 275124
302VW
POL Hand
Wheel
186839
PIGMEGR-766 90 With QCC 1 362733
PIGMEFMCULH 1/4 With QCC 1 Straight 362734
MFR#
AUTOMATIC
CHANGEOVER
REGULATOR
INCLUDED INLET OUTLET
PIGTAILS
INCLUDED-2
PIGTAIL
SIZES
BRACKET
INCLUDED
CAPACITY
BTU/HR.
PROPANE WEBB#
5726B23 7525B23
1/4
Inverted
Flare
1/2
F. NPT
912FA20 11/8 POL
2312-31 200,000
162794
5727B23 7525B23 912FS20 7/8 POL 162795
5744B4 7526B4 912FA20 11/8 POL
2503-22 450,000
186861
5745B4 7525B4 912FS20 7/8 POL 186862
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
5
1
SECTION
Regulators
High Pressure
Pounds-to-Pounds Regulator
Industrial/Commercial
Designed to reduce propane gas container pressure down to between 3 and 100 PSIG.
Ideal for liquid or vapor service, they can be used in a variety of applications including
salamander heaters, weed burning torches, fsh cookers, tar pot heaters, and other
industrial type services.
597FA-D
MFR#
ADJUSTMENT
METHOD
INLET
CONNECTION
OUTLET
CONNECTION
RECOMMENDED
DELIVERY
PRESSURE RANGE
(PSIG)
CAPACITY
DETERMINE AT
SET PRESSURE
OF PSIG
CAPACITY
BTU/HR.
PROPANE WEBB#
597FA
Tee Handle 1/4 F. NPT 1/4 F. NPT
1-15 10 1,750,000 162716
597FB 10-30 20 3,000,000 162717
597FC 20-45 30 3,500,000 162718
597FD 40-100 60 4,500,000 162719
MFR# SERVICE
ADJUSTMENT
METHOD
INLET &
OUTLET
CONNECTION
RECOMMENDED
DELIVERY
PRESSURE
RANGE (PSIG) WIDTH
HEIGHT
(MAX.)
CAPACITY
DETERMINE AT
SET PRESSURE
OF PSIG CAPACITY WEBB#
AA1582MW
NH3
Tee Handle
1/4 F. NPT
3-25
23/16 4
20 2,100 CFH NH
3 187087
AA1582ML 20-50 30 2,400 CFH NH
3 187086
AA1582MH 45-125 60 2,600 CFH NH
3 187085
1584MN
LP-Gas
1/2 F. NPT
3-30
215/16 47/8
20
7,000,000
BTU/hr. LPG
162800
1584ML 25-50 30
7,500,000
BTU/hr. LPG
162799
1584MH 45-125 60
8,000,000
BTU/hr. LPG
186810
AA1584MW
NH3
3-25 20 4,500 CFH NH
3 187089
AA1584ML 20-25 30 4,800 CFH NH
3 162412
AA1574MH 45-125 60 5,100 CFH NH
3 189234
1586MN
LP-Gas
3/4 F. NPT
3-30
31/2 7
20
11,000,000
BTU/hr. LPG
162802
1586ML 25-50 30
12,000,000
BTU/hr. LPG
162801
1586MH 45-125 60
14,000,000
BTU/hr. LPG
189126
AA1586MW
NH3
3-25 20 7,000 CFH NH
3 162414
AA1586ML 20-50 30 7,700 CFH NH
3 162413
AA1586MH 45-125 60 8,900 CFH NH
3 189235
1588MN
LP-Gas 1 F. NPT
3-30 20
11,000,000
BTU/hr. LPG
162804
1588ML 25-50 30
12,000,000
BTU/hr. LPG
250280
1588MH 45-125 60
14,000,000
BTU/hr. LPG
162803
High Pressure
Pounds-to-Pounds Regulators
Commercial/Industrial
Designed to reduce LP gas and anhydrous ammonia container pressures to between 3 and
125 PSIG. Precision-built with a multi-million BTU capacity, the 1580M Series is perfect for
such big, tough jobs as crop dryers, asphalt batch mixing plants, road building tar wagons,
heat treating and other large industrial and commercial loads.
1584MW
6
victormfg.com
1
SECTION
Gas Equipment Catalog
Regulator Accessories
High Pressure/High Temperature
Pounds-to-Pounds
Industrial/Commercial
Designed to reduce LP-Gas container pressures to between 3 and 50 PSIG. Ideal for crop
drying, heat treating, asphalt batch mixing and other large industrial and commercial load
application utilizing high temperature LP-Gas or high temperature atmosphere under
conditions up to 300F.
High Pressure Pounds-to-Pounds
Regulator Accessories
Industrial/Commercial
Designed for use as a relief valve on frst stage regulators that comply with NFPA 58 2.57.5
exception: frst stage regulators with a rated capacity of more that 500,000 BTU/hr. shall be
permitted to have a seperate relief valve.
X1584MW
3139
MFR# SERVICES
ADJUSTMENT
METHOD
INLET & OUTLET
CONNECTION
RECOMMENDED DELIVERY
PRESSURE RANGE (PSIG)
CAPACITY
DETERMINED AT SET
PRESSURE OF PSIG
CAPACITY
BTU/HR.
PROPANE WEBB#
X1584MN
LP Gas Tee Handle
1/2 F. NPT
3-20 20 7,000,000 190688
X1584ML 25-50 30 7,500,000 190687
X1586MN
3/4 F. NPT
3-30 20 11,000,000 250279
X1586ML 25-50 30 12,000,000 250290
MFR#
SET
PRESSURE
REGULATOR
SETTINGS
CONNECTION
SIZE HEIGHT WIDTH
FLOW CAPACITY AT
120% OF SET PRESSURE
(SCFH PROPANE) WEBB#
3139-18 18 PSIG 10 PSIG
1/4 M. NPT 227/32 11/16
1357* 266443
3139-26 26 PSIG 16 PSIG 1725** 266437
3139-38 38-PSIG 20 PSIG 2304*** 315791
* Flow recorded at 21.6 PSI inlet pressure for this valve.
** Flow recorded at 31.2 PSI inlet pressure for this valve.
*** Flow recorded at 45.6 PSI inlet pressure for this valve.
Victor/F.w. Webb offers webbConnect!
you can order, check current pricing
and inventory 24/7!
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
7
1
SECTION
Regulator Accessories
Copper Pigtails
Pigtails are available in a variety of connections, sizes and styles. care should always be
taken in selecting the proper pigtail for a particular application.
Note: Engineered controls International, Inc., recommends a new pigtail be installed with
every new and replaced regulator.
912JS20
MFR# CONNECTIONS
APPROX.
LENGTH TUBE
7/8 HEX
SHORT NIPPLE
11/8 HEX
LONG NIPPLE WEBB#
ALT MARSHALL
PIG# WEBB#
912PS12
M. POL X M. POL
12
1/4
7/8
188575
912PS20 20 162812
912PS30 30 PIG1664-30 186531
912PS36 36 162813
912PS48 48 162814
912FS12
1/4 Inverted
Flare X M. POL
12 216766 PIG1665-12 186532
912FS20 20 162806
912FS30 30 275012
912FS36 36 162807
POL X 1/4
Inverted Flare
48 PIG1665-48 186535
912JS12
1/4
M. NPT X M. POL
12 162808 PIG1663-48 186530
912JS20 20 162809
912JS36 36 188577
POL X 1/4 48 PIG1669-48 186539
912PA20
M. POL X M. POL
20
11/8
162810
912PA36 36 275011 PIG1660-36 186525
912PA48 48 162811
912FA20
1/4 Inverted
Flare X M. POL
20 162805
913PS05
M. POL X M. POL
5
3/8 7/8
273819
913PS12 12 202603
913PS20 20 188582
913PS30 30 250283 PIG1680-30 186544
913PS36 36 250284
913PS48 48 188581
913JS05A
90 Pre Bent
5 186999
913JS12 12 250282
POL X 1/2 MPT 20 PIG1684-20 186547
913S20
1/4
M. NPT X M. POL
20 187000 PIG1679HP-20 186549
8
victormfg.com
1
SECTION
Gas Equipment Catalog
Regulator Accessories
PATENTED PRESTO-TAP PIGTAIL PART NUMBERS
1/4 TUBE
FUGITIVE EMISSION REDUCTION
WEBB #
CONNECTIONS
APPROX.
LENGTH
7/8 HEX
SHORT NIPPLE
PIGTAIL
LENGTH
1/4 TUBE 3/8 TUBE
M.POL x M.POL 12 PT912PS12 12 80% 91% 244167
20 PT912PS20 20 82% NA 433019
48 PT912PS48 48 88% NA 433020
1/4 Inverted Flare x M.POL 20 PT912FS20
1/4 M. NPT x M.POL 12 PT912JS12
20 PT912JS20
3/8 TUBE
CONNECTIONS
APPROX.
LENGTH
7/8 HEX
SHORT NIPPLE
M.POL x M.POL 12 PT913PS12
1/4 M. NPT x M.POL 12 PT913JS12
PATENTED TANK PRESSURE FITTING
WEBB #
PART # THREAD CORE
BODY WRENCH
FLAT
CAP WRENCH
FLAT HEX
#54 ORIFICE APPLICATION
LDS2000RV 1/8 NPT Viton 7/16 9/16 Yes Tank Pressure 244172
REGULATOR & APPLIANCE FITTING
WEBB #
PART # THREAD CORE
BODY WRENCH
FLAT
CAP WRENCH
FLAT HEX
#54 ORIFICE APPLICATION
RVL 1/8 NPT Viton 7/16 9/16 No Low Pressure 433023
Patented Pigtail Products
Applicatoin: Pigtails are available in a variety of sizes and styles. care should always be
taken in selecting the proper pigtail for a particular application.
Patented Tank Pressure Fittings
Application: The patented Presto-Tap LDS2000RV is designed to obtain pressure readings
and perform system leak testing using tank pressure without ever breaking the system.
Meets NFPA 54 & 58 requirements regarding excess fow. compatible with all Presto-Tap
gauge products when used at correct locations
Regulator & Appliance Fitting
Application: The RVL low pressure ftting is designed to obtain pressure readings at frst
and second sage regulators. compatible with all Presto-Tap
Regulators in applications
requiring the use of a bracket.
2503-19 2503-22 2302-31
Tee Check Manifolds
For use in systems that require uninterrupted gas service during cylinder exchange.
Especially for summer cottages, mobile homes and single appliance loads.
Multiple Cylinder Manifolds
Use with suitable pigtails to connect multiple cylinders together. Ideal for loads that require
more than one cylinder to be in service at a time.
1350R
1450R
1350E
1450E
POL Inlet Fittings
These inlet fttings are available for assembly into either frst stage or single stage regulators.
All except for 970JR (1/4 hose barb) are machined from brass.
970 970AX 970AXS
970AW 970HT 970S
MFR# DESCRIPTION WEBB#
970 Hard nose POL with wrench nut. 191818
970AX Hard nose POL with wrench nut and excess flow. 187003
970AXS Soft nose POL with wrench nut and excess flow. 246565
3199W Heavy duty hard nose POL with wrench nut and excess flow. 186856
970AW Soft nose POL with handwheel. 187002
970HT Soft nose POL with handwheel and 60 DMS orifice. 243117
970S Soft nose POL with wrench nut and 60 DMS orifice. 162771
970JR Hard nose POL X 1/4 hose barb. 190842
MFR# MATERIAL
FOR USE WITH
REGULATOR MODEL WEBB#
2302-31
Cadium Plated
Steel
2302 Series/404B23 162798
2503-22
LV404 Series, 2503 Series,
LV4403 Series
162797
2503-19 Aluminum 162796
MFR#
INLET
CONNECTIONS
OUTLET
CONNECTION WEBB#
1350R F. POL M. POL 162820
1450R 1/4 Inverted Flare 1/4 M. NPT 162821
MFR#
INLET
CONNECTIONS
OUTLET
CONNECTION WEBB#
1350E F. POL M. POL 162819
1450E 1/4 Inverted Flare 1/4 M. NPT 162822
11/8 HEX L/Check
MARSHALL
PIG# WEBB#
PIG1000A 186519
PIG1702A 186552
MARSHALL
PIG# WEBB#
PIG1701B 186551
PIG1702B 186553
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
11
SECTION
1
Model 046 First Stage Field Regulators
MFR# DESCRIPTION
PIPE
SIZES BODY WEBB#
EQU046-12
High Pressure Regulator
First stage with internal relief valve.
3/4
Str
181910
EQU06-16 1 181929
EQU06-20 11/4 181930
NATURAL GAS (SP 0.6) CAPACITY (SCFH) ORIFICE
OUTLET
PRESSURE PSI BODY SIZE
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2
5
3/4 1190 2213 2775 3150 3375 4013
1 1190 2213 3975 6150 6375 7123
11/4 1190 2213 3975 6375 8100 7030
10
3/4 1190 2213 3638 4258 4453 6435
1 1190 2213 3900 5395 5775 5920
11/4 1190 2213 3900 5395 5940 6660
1350 BTU PROPANE/AIR MIX (SP 1.20) CAPACITY (SCFH) ORIFICE
OUTLET
PRESSURE PSI BODY SIZE
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2
5
3/4 845 1571 1970 2237 2396 2849
1 845 1571 2822 4367 4526 5057
11/4 845 1571 2822 4526 5751 4991
10
3/4 845 1571 2583 3023 3162 4569
1 845 1571 2769 3830 4100 4203
11/4 845 1571 2769 3830 4217 4720
PROPANE (SP 1.53) CAPACITY (BTU/HR)*
OUTLET
PRESSURE PSI
BODY
SIZE
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2
5
3/4 1,866,000 3,468,272 4,349,024 4,938,680 5,289,488 6,289,664
1 1,866,000 3,468,272 6,229,952 9,641,000 9,991,808 11,163,656
11/4 1,866,000 3,468,272 6,229,952 9,991,808 12,696,264 11,019,352
10
3/4 1,866,000 3,468,272 5,702,496 6,675,304 6,978,840 10,086,352
1 1,866,000 3,468,272 6,113,016 8,456,712 9,051,344 9,280,240
11/4 1,866,000 3,468,272 6,113,016 8,456,712 9,310,096 10,439,648
Yellow Spring (04600-021-00)
Outlet Pressure 3-10 psi at 75 psi Inlet Pressure
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot
from NFPA-58, 2008.
12
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Model 143-80 Second Stage
Service Regulators
The 143-80 is designed and built for domestic gas service, as well as for commercial and
industrial applications; burners, furnaces, ovens, heaters, gas engines, etc. it can also be
used for air, LPG, nitrogen, dry cO2 and other gases.
Simple, rugged construction means dependability. Yet, it provides precise pressure control
over an amazing range of pressure and load conditions.
It is simple to install and adjust. The union nut connection makes it easy to locate the
regulator in the best installed position, and servicing is easy and convenient.
MFR# DESCRIPTION SIZE WEBB#
143-80-212
Regulator With Internal Relief Valve (IRV)
3/4 Body 181913
143-80-216 1 Body 181909
143-80-220 11/4 Body 188875
143-80-2HP Special High Pressure Outlet Up To 6 psi 1 Body 247441
Maximum Inlet Pressures Spring Ranges
OUTLET PRES-
SURE RANGES SPRING COLOR
SPRING PART
NUMBER WEBB#
31/2 to 61/2 W.C. Red 143-62-021-15 181952
5 to 81/2 W.C. Blue 143-62-021-16 188872
6 to 14 W.C. Green 143-62-021-17 274440
12 W.C. to 1 psi Orange 143-62-021-18 186673
1/2 psi to 2 psi Black & White 143-92-021-22 188876
2 psi to 6 psi Black* 139-16-021-01
Capacities for Other Gases
For capacities (in ScFH) of other gases, multiply the capacity values
by a correction factor from the table below:
OTHER
GASES SPECIFIC GRAVITY CORRECTION FACTOR
Propane 1.53 0.63
ORIFICE
SIZES 5/8 1/2 3/8 5/16 1/4 3/16 1/8
Max Inlet
Pressure
10 psi 20 psi 40 psi 40 psi 60 psi 125 psi 125 psi
* Good for use in 143 802HP Series only
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
3/4 X 3/4
0.5 340 450 510
1 480 500 510 530
2 530 560 570 580 600
3 420 600 620 630 650 670
5 250 560 700 720 730 770 790
71/2 310 700 840 860 880 900 900
10 370 830 950 970 1000 1020 1020
20 530 1200 1220 1240 1250 1270
40 860 1570 1330 1340 1450
60 1200 1660 1520
80 1500 1710
125 1800 1900
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
1 X 1
0.5 350 460 520
1 480 550 600 650
2 530 700 840 880 780
3 420 650 870 1000 920 810
5 250 580 890 1120 1160 950 970
71/2 310 700 1140 1340 1270 1140 1060
10 370 840 1360 1500 1330 1200 1180
20 530 1230 2000 1600 1480 1400
40 860 1700 2000 1640 1900
60 1200 1900 2000
80 1540 2000
125 2100 2100
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
11/4 X
11/4
0.5 350 460 520
1 480 550 680 760
2 530 700 840 1020 1030
3 420 650 870 1030 1200 1050
5 250 580 890 1180 1350 1490 1060
71/2 310 700 1140 1500 1610 1580 1060
10 370 840 1360 1700 1710 1800 1180
20 630 1230 1600 1800 1900 1900
40 860 1800 2200 1900 2000
60 1200 2100 2400
80 1550 2200
125 2250 2400
Natural Gas Chart
143-80-2, and 143-80-2HP Capacity in SCFH Natural Gas (0.6 Specifc Gravity, 14.65 psia, 60F)
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
13
SECTION
1
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
1 X 1
0.5 549 721 815
1 752 862 940 1019
2 831 1097 1317 1379 1223
3 658 1019 1364 1567 1442 1270
5 392 909 1395 1756 1818 1489 1661
71/2 486 1097 1787 2100 1991 1787 1850
10 580 1317 2132 2351 2085 1881
20 831 1928 3135 2508 2320 2194
40 1348 2665 3135 2571 2978
60 188 2978 3135
80 2414 3135
125 3292 3292
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
11/4 X
11/4
0.5 549 721 815
1 752 862 1066 1191
2 831 1097 1317 1599 1614
3 658 1019 1364 1614 1881 1646
5 392 909 1395 1850 2116 2335 1661
71/2 486 1097 1787 2351 2524 2477 1661
10 580 1317 2132 2665 2680 2821 1850
20 987 1928 2508 2821 2978 2978
40 1348 2821 3448 2978 3135
60 1881 3292 3762
80 2430 3448
125 3527 3762
Model 143-80 Second Stage
Service Regulators (continued)
Propane Gas Chart*
143-80-2, and 143-80-2HP Capacity in 1000s of BTUs of Undiluted Propane
(1.5 Specifc Gravity, 14.65 psia, 60F)
PIPE
SIZE
INLET
PRESSURE
PSI
ORIFICE SIZE
1/8 3/16 1/4 5/16 3/8 1/2 5/8
3/4 X 3/4
0.5 533 705 799
1 752 784 799 831
2 831 878 893 909 940
3 658 940 972 987 1019 1050
5 392 878 1097 1129 1144 1207 1238
71/2 486 1097 1317 1348 1379 1411 1411
10 580 1301 1489 1520 1567 1599 1599
20 831 1881 1912 1944 1959 1991
40 1348 2461 2085 2100 2273
60 1861 2602 2383
80 2351 2680
125 2821 2978
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction
factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Victor/F.w. Webb has over 125 outside
sales people available to help you. If you
need technical expertise, weve got it!
14
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Model 243 Second Stage
Service Regulators
These large capacity service regulators are designed and built for commercial, industrial
and gas distribution work. They are right at home in such places as factories and foundries,
district regulator stations, commercial laundries and laundromats, motels-hotels and
apartments, bakeries, restaurants, schools, churches and hospitals.
The versatile 243 is used for all kinds of gas fueled equipment. . .boilers, burners, furnaces,
ovens, heaters, kilns, engines, air conditioners, etc.
Remarkable feld versatility results from the union connection between the fully
interchangeable bodies and diaphragm-case assemblies. They are easy to install, adjust,
inspect and service in all kinds of piping arrangements.
while used primarily for natural gas services, Model 243 regulators perform equally well on
LPG vapor, air, dry cO2, nitrogen and other inert gas applications.
Basic Models
Outlet Pressure Ranges and Springs
Maximum Inlet Pressure, psig
MFR# DESCRIPTION SIZES TEMPERATURE LIMIT WEBB#
243-12-224
12 Diaphram with Internal Relief
11/2 Body
-20F to 150F
181915
243-12-232 2 Body 181916
243-8-220
8 Diaphram with Internal Relief
11/4 Body 181917
243-8-224 11/2 Body 181918
243-8-232 2 Body 259165
243-8HP-2 Special High Pressure Regulator 2 Body 247442
SPRING
COLOR
OUTLET PRESSURE RANGE
SPRING PART# WEBB# 243-12 243-8
Red-Black 31/2 to 61/2 W.C. 143-82-021-00 181954
Blue-Black 5 to 81/2 W.C. 143-82-021-01
Green-Black 6 to 14 W.C. 143-82-021-02
Red 31/2 to 61/2 W.C. 143-16-21-03 188870
Blue 5 to 81/2 W.C. 143-16-021-04
Green 6 to 14 W.C. 12 to 28 W.C. 143-16-021-05 254467
Orange-Black 10 to 18 W.C. 143-16-021-11
Orange 12 to 28 W.C. 1 to 2 psi 143-16-021-06 181953
Black 1 to 2 psi 2 to 41/2 psi* 143-16-021-07 181934
Cadium 11/2 to 3 psi 3 to 61/2 psi* 143-16-021-08 188871
Cadium
6 to 10 psi*
143-16-021-08
White 143-16-021-13
Clamping Plate 143161020100 308181
Capacities for Other Gases
For capacities ( in ScFH) of other
gases, multiply the capacity values by a
correction factor from the table below:
OTHER
GASES
SPECIFIC
GRAVITY
CORRECTION
FACTOR
Propane 1.53 0.63
REGULATOR
MODEL AND SIZE
ORIFICE SIZE AND ANGLE
11/4 11/4* 1 1* 3/4 3/4 1/2 3/8 1/4 .207
30 10 30 10 30 10 10 10 10 10
11/4, 243-12 15 25 25 40 60 100 125 125
11/2, 243-12 15 25 25 40 60 100 125 125
2, 243-12 15 25 25 40 40 60 100 125 125
11/4, 243-8 40 80 100 125 125
11/2, 243-8 25 40 80 100 125 125
2, 243-8 25 40 40 80 100 125
11/4, 243-8HP 40 80 100 125
11/2, 243-8HP 25 40 80 100 125
2, 243-8HP 25 40 80 100 125
* Good for use in 243 8HP Series only
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
15
SECTION
1
243 Variations
Internal Relief Valves
The 243 is available with an internal relief valve (IRV). Its a built-in safety device for
providing a limited level of over-pressure protection.
Like any relief valve, an IRV must be carefully sized.
Internal relief valves are not available in the high pressure Model 243-8HP.
Natural Gas Chart
11/2 Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
Model 243 Capacity Tables
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
11 W.C.
2 W.C. Droop
Green Spring
6 to 14 W.C.
143-16-021-05
1 2700 2300 1900 1100 750 400
2 4000 3500 2700 1900 1200 600
5 6000 5600 4500 3500 2100 1000
10 8800 8200 6500 5500 2900 1400
15 10000 9800 7700 6800 3800 1750
25 11500 9700 8100 5100 2400
40 11500 9700 7100 3200
60 12500 11500 9300 4400
80 12000 10500 5600
100 12500 11000 7000
125 11000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
11 W.C.
2 W.C. Droop
Green Spring
6 to 14 W.C.
143-16-021-05
1 4232 3605 2978 1724 1176 627
2 6270 5486 4232 2978 1881 940
5 9405 8778 7053 5486 3292 1567
10 13793 12853 10188 8621 4546 2194
15 15674 15361 12069 10659 5956 2743
25 18026 15204 12696 7994 3762
40 18026 15204 11129 5016
60 19593 18026 14577 6897
80 18809 16458 8778
100 19593 17242 10972
125 17242 12540
Propane Gas Chart
11/2 Model 243-12-2 Capacity Table in 1000s of BTUs or Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
1 psi .31 psi
Droop Orange
Spring 12 to
28 W.C.
143-16-021-06
2 6500 5000 4000 2000 1300 500
5 8000 7500 6000 4000 2200 1000
10 9000 8500 8000 5500 3000 1400
15 12000 11500 10000 7000 4000 1800
25 13500 11500 9500 5500 2400
40 13000 11000 7400 3300
60 15000 13500 10000 4500
80 15000 13000 6000
100 16000 14000 7000
125 14000 8500
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
1 psi .31
psi Droop
Orange
Spring 12
to 28 W.C.
143-16-021-06
2 10188.4 7837.2 6269.76 3134.88 2037.67 783.72
5 12539.5 11755.8 9404.64 6269.76 3448.37 1567.44
10 14107 13323.2 12539.5 8620.92 4702.32 2194.42
15 18809.3 18025.6 15674.4 10972.1 6269.76 2821.39
25 21160.4 18025.6 14890.7 8620.92 3761.86
40 20376.7 17241.8 11599.1 5172.55
60 23511.6 21160.4 15674.4 7053.48
80 23511.6 20376.7 9404.64
100 25079 21944.2 10972.1
125 21944.2 13323.2
16
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Natural Gas Chart
11/2 Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
1 psi .2 psi
Droop Black
Spring
1 to 2 psi
143-16-021-07
2 2800 2450 1500 1200 850 500
5 5500 5100 3700 2400 1600 950
10 8000 7500 5700 4000 2700 1400
15 10000 9100 7100 5300 3700 1750
25 11000 9300 7300 5100 2400
40 11000 9300 7100 3200
60 12500 11000 9300 4600
80 12500 10500 5600
100 13000 11000 7000
125 11000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
1 psi .2 psi
Droop Black
Spring
1 to 2 psi
143-16-021-07
2 4389 3840 2351 1881 1332 784
5 8621 7994 5800 3762 2508 1489
10 12540 11756 8934 6270 4232 2194
15 15674 14264 11129 8307 5800 2743
25 17242 14577 11442 7994 3762
40 17242 14577 11129 5016
60 19593 17242 14577 7210
80 19593 16458 8778
100 20377 17242 10972
125 17242 12540
Propane Gas Chart
11/2 Model 243-12-2 Capacity Table in 1000s of BTUs or Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
2 psi .6 psi
Droop Cadium
Spring
11/2 to 3 psi
143-16-021-08
5 6000 5300 4100 2700 1700 900
10 10000 9300 7100 4700 2900 1400
15 13000 12000 8800 6200 3800 1700
25 14500 11000 8600 5200 2400
40 13500 11000 7100 3200
60 15000 13500 10000 4600
80 15000 12000 5600
100 16000 12000 7000
125 12000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 1/2 3/8 1/4
30 30 10 10 10 10
11/2
Set Point
2 psi .6 psi
Droop Cadium
Spring
11/2 to 3 psi
143-16-021-08
5 9405 8307 6427 4232 2665 1411
10 15674 14577 11129 7367 4546 2194
15 20377 18809 13793 9718 5956 2665
25 22728 17242 13480 8151 3762
40 21160 17242 11129 5016
60 23512 21160 15674 7210
80 23512 18809 8778
100 25079 18809 10972
125 18809 12540
Model 243 Capacity Tables (continued)
Victor/F.w. Webb can provide
customized training for your company!
Just ask your victor sales person.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
17
SECTION
1
Model 243 Capacity Tables (continued)
Natural Gas Chart
2 Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point 11
W.C. 2 W.C.
Droop Green
Spring 6 to
14 W.C.
143-16-021-05
1 3400 3000 2100 1950 1150 750 400
2 5600 4700 3700 3400 2000 1200 600
5 10500 9000 7800 6900 3500 2100 1000
10 13000 13000 12000 9200 5500 3200 1600
15 14000 14000 15000 10500 7000 4000 1800
25 15000 20000 12000 500 5300 2400
40 20000 14500 12500 7500 3200
60 15500 13000 10000 4400
80 14000 12000 5600
100 14000 12000 7000
125 12000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point 11
W.C. 2 W.C.
Droop Green
Spring 6 to
14 W.C.
143-16-021-05
1 5329 4702 3292 3057 1803 1176 627
2 8778 7367 5800 5329 3135 1881 940
5 16458 14107 12226 10815 5486 3292 1567
10 20377 20377 18809 14420 8621 5016 2508
15 21944 21944 23512 16458 10972 6270 2821
25 23512 31349 18809 784 8307 3762
40 31349 22728 19593 11756 5016
60 24295 20377 15674 6897
80 21944 18809 8778
100 21944 18809 10972
125 18809 12540
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
1 psi
.31 psi Droop
Orange
Spring 12 to
28 W.C.
143-16-021-06
2 6500 5000 4000 4000 2000 1300 500
5 8000 7500 6000 6000 4000 2200 1000
10 9000 8500 8000 8000 5500 3000 1400
15 12000 11000 10000 10000 7000 4000 1800
25 13500 12500 11500 9500 5500 2400
40 14000 13000 11000 7400 3300
60 15000 13500 10000 4500
80 15000 13000 6000
100 16000 14000 7000
125 14000 8500
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
1 psi
.31 psi Droop
Orange
Spring 12 to
28 W.C.
143-16-021-06
2 10188 7837 6270 6270 3135 2038 784
5 12540 11756 9405 9405 6270 3448 1567
10 14107 13323 12540 12540 8621 4702 2194
15 18809 17242 15674 15674 10972 6270 2821
25 21160 19593 18026 14891 8621 3762
40 21944 20377 17242 11599 5173
60 23512 21160 15674 7053
80 23512 20377 9405
100 25079 21944 10972
125 21944 13323
Propane Gas Chart
2 Model 243-12-2 Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
Victor/F.w. Webb can help you
layout a petite 7
base board system.
18
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Natural Gas Chart
11/4 Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
Model 243 Capacity Tables (continued)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE
ANGLE
3/4 1/2 3/8 1/4 0.207
10 10 10 10 10
11/4
Set Point 11
wc. 2 wc
Droop Green
Spring 6 to
14 wc
143-82-021-02
1 1150 1000 650 300
2 1850 1350 1000 450 350
5 2500 2200 1750 800 550
10 2900 2700 2450 1300 900
15 3700 2950 2600 1700 1100
25 4250 4000 3300 2400 1500
40 5300 4200 3800 3200 2100
60 4850 4400 4400 2900
80 5850 5600 5600 3700
100 6000 7000 4500
125 8000 5600
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE
ANGLE
3/4 1/2 3/8 1/4 0.207
10 10 10 10 10
11/4
Set Point 11
wc. 2 wc
Droop Green
Spring 6 to
14 wc
143-82-021-02
1 1803 1567 1019 470
2 2900 2116 1567 705 549
5 3919 3448 2743 1254 862
10 4546 4232 3840 2038 1411
15 5800 4624 4075 2665 1724
25 6662 6270 5173 3762 2351
40 8307 6583 5956 5016 3292
60 7602 6897 6897 4546
80 9170 8778 8778 5800
100 9405 10972 7053
125 12540 8778
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE
ANGLE
3/4 1/2 3/8 1/4 0.207
10 10 10 10 10
11/4
Set Point 1 psi
Droop Orange
Spring 1 to 2 psi
143-16-021-06
2 1850 1150 850 450
5 2100 1700 1350 750 500
10 2700 2000 1950 1300 800
15 3150 3100 2050 1700 1000
25 4150 3250 2850 2400 1500
40 5300 3800 3600 3200 2100
60 4600 4250 4400 2900
80 4650 5600 5600 3700
100 6000 7000 4500
125 8000 5600
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE
ANGLE
3/4 1/2 3/8 1/4 0.207
10 10 10 10 10
11/4
Set Point 1 psi
Droop Orange
Spring 1 to 2 psi
143-16-021-06
2 2900 1803 1332 705
5 3292 2665 2116 1176 784
10 4232 3135 3057 2038 1254
15 4937 4859 3213 2665 1567
25 6505 5094 4467 3762 2351
40 8307 5956 5643 5016 3292
60 7210 6662 6897 4546
80 7289 8778 8778 5800
100 9405 10972 7053
125 12540 8778
Propane Gas Chart
11/4 Model 243-8-2 Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
19
SECTION
1
Natural Gas Chart
2 Model 243-12-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
Model 243 Capacity Tables (continued)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
1 psi .2 psi
Droop Black
Spring 1 to
2 psi
143-16-021-07
2 3350 3000 2000 1900 1200 1000 500
5 6600 5900 4200 3900 2400 1600 1000
10 11000 10000 7600 6500 4100 2800 1450
15 13000 12000 9300 8300 5600 3800 1700
25 15000 16500 11000 8500 5300 2400
40 20000 14000 12500 7500 3400
60 15500 13000 10000 4400
80 14000 12000 5600
100 14000 12000 7000
125 12000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
1 psi .2 psi
Droop Black
Spring 1
to 2 psi
143-16-021-07
2 5251 4702 3135 2978 1881 1567 784
5 10345 9248 6583 6113 3762 2508 1567
10 17242 15674 11913 10188 6427 4389 2273
15 20377 18809 14577 13010 8778 5956 2665
25 23512 25863 17242 13323 8307 3762
40 31349 21944 19593 11756 5329
60 24295 20377 15674 6897
80 21944 18809 8778
100 21944 18809 10972
125 18809 12540
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
2 psi .6 psi
Droop
Cadium
Spring 11/2
to 3 psi
143-16-021-08
5 8200 7400 5200 4800 2900 1900 900
10 12500 11300 8700 7800 4800 3000 1400
15 15500 14500 11500 10000 6500 3800 1700
25 18000 16500 13500 9000 5300 2400
40 20000 16500 12500 7600 3400
60 16500 15500 10000 4600
80 16000 12000 5600
100 16000 12000 7000
125 12000 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
11/4 1 3/4 3/4 1/2 3/8 1/4
30 30 30 10 10 10 10
2
Set Point
2 psi .6 psi
Droop
Cadium
Spring 11/2
to 3 psi
143-16-021-08
5 12853 11599 8151 7524 4546 2978 1411
10 19593 17712 13637 12226 7524 4702 2194
15 24295 22728 18026 15674 10188 5956 2665
25 28214 25863 21160 14107 8307 3762
40 31349 25863 19593 11913 5329
60 25863 24295 15674 7210
80 25079 18809 8778
100 25079 18809 10972
125 18809 12540
Propane Gas Chart
2 Model 243-12-2 Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
20
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Model 243 Capacity Tables (continued)
Natural Gas Chart
2 and 11/2 Model 243-8-2 Capacity Table in SCFH of Natural Gas (0.6 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
2 and 11/2
Set Point
11 W.C.
2 W.C. Droop
Green Spring
6 to 14 W.C.
143-82-021-02
1 1650 1150 1000 650 300
2 2700 2000 1400 1000 450 350
5 4800 3800 2600 1750 900 600
10 7000 5400 4200 2800 1300 900
15 9000 7400 5500 3600 1700 1100
25 11000 8800 7500 5100 2400 1500
40 11000 9600 7100 3200 2100
60 11000 9300 4400 2900
80 11500 10500 5600 3700
100 11000 7000 4500
125 8000 5600
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
11/2
Set Point 2 psi
.2 Droop
Orange Spring
1 to 2 psi
143-16-021-06
2 2100 1650 1200 850 450
5 4000 3200 2100 1300 850 550
10 6500 5200 3100 2200 1300 800
15 8400 6500 4400 3000 1700 1000
25 11000 11000 6500 4400 2400 1500
40 8600 6700 3200 2100
60 10500 9000 4400 2900
80 11500 10500 5600 3700
100 11000 7000 4500
125 8000 5600
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
2
Set Point 2 psi
.2 Droop
Orange Spring
1 to 2 psi
143-16-021-06
2 2400 1800 1700 1200 850 450
5 4000 3400 3300 2200 1300 900
10 7000 6000 5400 3500 2200 1400
15 11000 9000 7000 4600 3100 1700
25 14500 15000 10000 7400 4800 2400
40 17500 12000 10500 7000 3400
60 11000 9500 4600
80 10500 5600
100 11000 7000
125 8000
Propane Gas Chart*
2 and 11/2 Model 243-8-2 Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
2 and 11/2
Set Point
11 W.C. 2
W.C. Droop
Green Spring
6 to 14 W.C.
143-82-021-02
1 2586 1803 1567 1019 470
2 4232 3135 2194 1567 705 549
5 7524 5956 4075 2743 1411 940
10 10972 8464 6583 4389 2038 1411
15 14107 11599 8621 5643 2665 1724
25 17242 13793 11756 7994 3762 2351
40 17242 15047 11129 5016 3292
60 17242 14577 6897 4546
80 18026 16458 8778 5800
100 17242 10972 7053
125 12540 8778
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
11/2
Set Point 2 psi
.2 Droop
Orange Spring
1 to 2 psi
143-16-021-06
2 3292 2586 1881 1332 705
5 6270 5016 3292 2038 1332 862
10 10188 8151 4859 3448 2038 1254
15 13166 10188 6897 4702 2665 1567
25 17242 13480 10188 6897 3762 2351
40 17242 13480 10502 5016 3292
60 16458 14107 6897 4546
80 18026 16458 8778 5800
100 17242 10972 7053
125 12540 8778
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4 0.207
30 10 10 10 10 10
2
Set Point 2 psi
.2 Droop
Orange Spring
1 to 2 psi
143-16-021-06
2 3762 2821 2665 1881 1332 705
5 6270 5329 5173 3448 2038 1411
10 10970 9405 8484 5486 3448 2194
15 17242 14107 10972 7210 4859 2665
25 22728 23512 15674 11599 7524 3762
40 27430 18809 16458 10972 5329
60 19593 14891 7210
80 21160 16458 8778
100 17242 10972
125 1250
* Note 1: Propane chart is a mathematical extrapolation using 0.63 correction
factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
21
SECTION
1
Natural Gas Chart
11/4, 11/2, 2 Models 243-8HP Capacity Table in SCFH of Natural Gas
(0.6 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
*
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
3/4 1/2 3/8 1/4
10 10 10 10
11/4
Set Point 5 psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 3300 2050 2000 1300
15 3400 3100 2200 1700
25 4400 3650 3050 2400
40 5800 3800 3200 3200
60 4400 4100 4400
80 4500 5300 5600
100 6000 7000
125 8000
PIPE SIZE
*
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4
30 10 10 10 10
11/2
Set Point 5 psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 6000 5500 3200 2300 1300
15 8600 6500 4400 3200 1700
25 12000 9300 6100 4800 2400
40 12000 8500 6100 3200
60 10000 8700 4400
80 11000 10000 5600
100 11000 7000
125 8000
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4
30 10 10 10 10
2
Set Point 5 psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 6000 5500 3200 2400 1300
15 8600 6500 4400 3200 1700
25 13000 8200 6100 4800 2400
40 12000 8700 6100 3400
60 10000 8700 4600
80 11500 10000 5600
100 11000 7000
125 8000
Propane Gas Chart**
11/4, 11/2, 2 Models 243-8HP Capacity Table in 1000s of BTUs Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
PIPE SIZE
*
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
3/4 1/2 3/8 1/4
10 10 10 10
11/4
Set Point 5 psi 1 psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 5173 3213 3135 2038
15 5329 4859 3448 2665
25 6897 5721 4781 3762
40 9091 5956 5016 5016
60 6897 6427 6897
80 7053 8307 8778
100 9405 10972
125 12540
PIPE SIZE
*
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4
30 10 10 10 10
11/2
Set Point 5 psi 1 psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 9405 8621 5016 3605 2038
15 13480 10188 6897 5016 2665
25 18809 14577 9561 7524 3762
40 18809 13323 9561 5016
60 15674 13637 6897
80 17242 15674 8778
100 17242 10972
125 12540
PIPE SIZE
INLET
PRESSURE
(PSI)
ORIFICE SIZE AND VALVE ANGLE
1 3/4 1/2 3/8 1/4
30 10 10 10 10
2
Set Point 5 psi 1psi
Droop Cadium Spring
3 to 61/2 psi
143-16-021-08
10 9405 8621 5016 3762 2038
15 13480 9405 6897 5016 2665
25 20377 12853 9561 7524 3762
40 18809 13637 9561 5329
60 15674 13637 7210
80 17242 15674 8778
100 17242 10972
125 12540
* Special Order
** Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
Model 243 High Pressure Capacity Tables
22
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Gas Appliance Pressure Regulators
Maxitrol company manufactures a complete line of gas appliance regulators for domestic,
commercial, and industrial needs.
Balance Valve Design 210D, E & G
Main burner and pilot applications.
The balanced valve 210 Series are designed for use with intermediate pressure.
The balancing diaphragm virtually eliminates inlet pressure effect, which makes
them ideal for applications where supply pressure fuctuates.
210D, E & G
MFR# PIPE SIZES CAPACITIES TO
INLET
PRESSURES TO
OUTLET
PRESSURES
210D
1, 11/4, 11/2,
2, 21/2, & 3
6500 CFH
10 psi (700 mbar)
1.0 to 42 W.C.
(2.5 to 105 mbar)
210E 12000 CFH
210G 26000 CFH
MFR# BODY SIZES QTY. PER CASE WEBB#
210D-1 1 4 201676
210D-1010-114 11/4 4 201679
210D-112 11/2 4 201678
210D-36-24 11/2 4 199526
210D412-24 11/2 4
210E-2 2 2 198116
210E412-24 11/2 2 201673
210E412-32 2 2 201674
Natural Gas Chart
11/2 & 2 Stock Spring Violet 4-12 w.c. Model 210E Capacity Table in SCFH of Natural Gas
(0.6 Specifc Gravity 14.65 psia 60F)
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/2
8 w.c. 4450 3650 2550
.5 psi 6300 5750 5150 4050
.75 psi 7000 7500 7050 6300 5450 4050
1 psi 7000 8800 8500 7950 7250 6300
1.5 psi 7000 8800 8500 10450 9950 9250
2 psi 7000 8800 8500 10500 10500 10500
3 psi 7000 8800 8500 10500 10500 10500
5 psi 7000 8800 8500 10500 10500 10500
7.5 psi 7000 8800 8500 10500 10500 10500
10 psi 7000 8800 8500 10500 10500 10500
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
2
8 w.c. 5150 4200 2950
.5 psi 7250 6650 5950 4700
.75 psi 8000 8650 8150 7250 6300 4700
1 psi 8000 10000 9850 9150 8400 7250
1.5 psi 8000 10000 10000 12000 11500 10700
2 psi 8000 10000 10000 12000 12000 12000
3 psi 8000 10000 10000 12000 12000 12000
5 psi 8000 10000 10000 12000 12000 12000
7.5 psi 8000 10000 10000 12000 12000 12000
10 psi 8000 10000 10000 12000 12000 12000
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
23
SECTION
1
Gas Appliance Pressure Regulators (continued)
Propane Gas Chart*
11/2 and 2 Stock Spring Violet 4-12 w.c.
Model 120E Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
Natural Gas Chart
1 & 11/4 Stock Spring Violet 4-12 w.c. Model 210D Capacity Table in SCFH of Natural Gas
(0.64 Specifc Gravity 14.65 psia 60F)
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/2
8 w.c. 6975 5721 3997
.5 psi 9875 9013 8072 6348
.75 psi 10972 11756 11050 9875 8543 6348
1 psi 10972 13793 13323 12461 11364 9875
1.5 psi 10972 13793 13793 16380 15596 14499
2 psi 10972 13793 13793 16458 16458 16458
3 psi 10972 13793 13793 16458 16458 16458
5 psi 10972 13793 13793 16458 16458 16458
7.5 psi 10972 13793 13793 16458 16458 16458
10 psi 10972 13793 13793 16458 16458 16458
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
1
8 w.c. 2400 1900 1300
.5 psi 3400 3100 2700 2200
.75 psi 3500 4000 3800 3400 2900 2200
1 psi 3500 4000 4500 4300 3900 3400
1.5 psi 3500 4000 4500 4800 4800 5000
2 psi 3500 4000 4500 4800 4800 5000
3 psi 3500 4000 4500 4800 4800 5000
5 psi 3500 4000 4500 4800 4800 5000
7.5 psi 3500 4000 4500 4800 4800 5000
10 psi 3500 4000 4500 4800 4800 5000
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
2
8 w.c. 8072 6583 4624
.5 psi 11364 10423 9326 7367
.75 psi 12540 13558 12775 11364 9875 7367
1 psi 12540 15674 15439 1432 13166 11364
1.5 psi 12540 15674 15674 18809 18026 16772
2 psi 12540 15674 15674 18809 18809 18809
3 psi 12540 15674 15674 18809 18809 18809
5 psi 12540 15674 15674 18809 18809 18809
7.5 psi 12540 15674 15674 18809 18809 18809
10 psi 12540 15674 15674 18809 18809 18809
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/4
8 w.c. 3000 2400 1700
.5 psi 4000 3905 3400 2700
.75 psi 4000 5000 4700 4200 3700 2700
1 psi 4000 5000 5000 5300 4900 4200
1.5 psi 4000 5000 5000 6000 6000 6000
2 psi 4000 5000 5000 6000 6000 6000
3 psi 4000 5000 5000 6000 6000 6000
5 psi 4000 5000 5000 6000 6000 6000
7.5 psi 4000 5000 5000 6000 6000 6000
10 psi 4000 5000 5000 6000 6000 6000
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
24
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
Gas Appliance Pressure Regulators (continued)
Natural Gas Chart
11/2 Stock Spring Violet 4-12 w.c. Model 210D Capacity Table in SCFH of Natural Gas
(0.64 Specifc Gravity 14.65 psia 60F)
Propane Gas Chart*
1, 11/4 and 11/2 Stock Spring Violet 4-12 w.c.
Model 210D Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/2
8 w.c. 3100 2500 1800
.5 psi 4000 4000 3600 2800
.75 psi 4000 5000 5000 4400 3800 2800
1 psi 4000 5000 5000 5600 5100 4400
1.5 psi 4000 5000 5000 6000 6000 6500
2 psi 4000 5000 5000 6000 6000 6500
3 psi 4000 5000 5000 6000 6000 6500
5 psi 4000 5000 5000 6000 6000 6500
7.5 psi 4000 5000 5000 6000 6000 6500
10 psi 4000 5000 5000 6000 6000 6500
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
1
8 w.c. 3762 2978 2038
.5 psi 5329 4859 4232 3448
.75 psi 5486 6270 5956 5329 4546 3448
1 psi 5486 6270 7053 6740 6113 5329
1.5 psi 5486 6270 7053 7524 7524 7837
2 psi 5486 6270 7053 7524 7524 7837
3 psi 5486 6270 7053 7524 7524 7837
5 psi 5486 6270 7053 7524 7524 7837
7.5 psi 5486 6270 7053 7524 7524 7837
10 psi 5486 6270 7053 7524 7524 7837
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/4
8 w.c. 4702 3762 2665
.5 psi 6270 6121 5329 4232
.75 psi 6270 7837 7837 6583 5800 4232
1 psi 6270 7837 7837 8307 7080 6583
1.5 psi 6270 7837 7837 9405 9405 9405
2 psi 6270 7837 7837 9405 9405 9405
3 psi 6270 7837 7837 9405 9405 9405
5 psi 6270 7837 7837 9405 9405 9405
7.5 psi 6270 7837 7837 9405 9405 9405
10 psi 6270 7837 7837 9405 9405 9405
PIPE
SIZE
INLET
PRESSURE (PSI)
SET POINT
2 W.C.
SET POINT
4 W.C.
SET POINT
6 W.C.
SET POINT
9 W.C.
SET POINT
12 W.C.
SET POINT
16 W.C.
11/2
8 w.c. 4869 3919 2821
.5 psi 6270 6270 5643 4389
.75 psi 6270 7837 7837 6897 5956 4389
1 psi 6270 7837 7837 8778 7994 6897
1.5 psi 6270 7837 7837 9405 9405 10188
2 psi 6270 7837 7837 9405 9405 10188
3 psi 6270 7837 7837 9405 9405 10188
5 psi 6270 7837 7837 9405 9405 10188
7.5 psi 6270 7837 7837 9405 9405 10188
10 psi 6270 7837 7837 9405 9405 10188
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
25
SECTION
1
RV52 & RV53
RV61
RV81 & RV91
RV111
RV131
Straight-Thru-Flow-Design
RV52, RV53, RV61, RV81, RV91, RV111, RV131
1/2, 3/4, 11/4, 11/2, 2, 21/2, 3, & 4
Main burner only
The straight-thru-fow RV Series, size for size, has the highest pressure drop capacity of any
regulator design available. They are best used when supply pressure is low enough to cause
concern about capacity.
Gases: Natural, manufactured, mixed, liquifed petroleum, or LP gas-air mixture.
Features:
Greater accuracy higher pressure drop capacity.
Outlet pressure available to 42 w.c.
Available in full range of pipe sizes from 1/2 to 4.
All models tapped with NPT vent bosses.
A.G.A. Rated (except RV131) 1/2 psi (35 mbar).
MFR# PIPE SIZES CAPACITIES TO
INLET
PRESSURES TO
OUTLET
PRESSURES
RV52 1/2 & 3/4 900 CFH
1/2 psi (35 mbar) 1.0 to 12 W.C.
RV53 3/4 & 1 130 CFH
RV61 1 & 11/4 2500 CFH
1 psi (70 mbr) 1.0 to 22 W.C.
RV81
11/4, 11/2, 2 & 21/2
4500 CFH
RV91 7500 CFH
RV111 21/2 & 3 1 psi
RV131 4 Flanged 2 psi 2 psi (140 mbr) 3.0 to 42 W.C.
MFR# BODY SIZES QTY. PER CASE WEBB#
RV52-12 1/2 25 108537
RV52-34 3/4 25 196920
RV53-1 1 25 118670
RV53-34 3/4 25 108742
RV61-1 1 18 185908
RV61-114 11/4 18 188934
RV81-114 11/4 4 196848
RV91-2 2 4 109623
Natural Gas Chart
Straight thru fow RV regulator (Appliance or combustion regulators)
Capacity Table in CFHs of Natural Gas (0.64 Specifc Gravity 14.65 psia 60F)
MFR# PIPE SIZE
CSA
MAX
PRESSURE DROP IN W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4
RV52 1/2 or 3/4 450 151 214 362 302 338 370 400 427 453 478 676 828 956
RV53 3/4 or 1 710 217 306 375 433 484 530 573 612 650 684 968 1185 1369
RV61 1 or 11/4 1100 379 536 675 759 848 929 1004 1073 1138 1200 1742 2134 2464
RV81 11/4 or 11/2 2500 780 1102 1350 1559 1743 1909 2062 2204 2339 2465 3465 4269 4929
RV91 2 or 21/2 3275 1212 1714 2100 2424 2711 2969 3208 3429 3637 3834 5422 6640 7668
RV111 21/2 or 3 7500 2742 3878 4750 5485 6718 6718 7256 7757 8227 8572 14134 14862 17161
RV131 4 4734 6695 8200 9468 11596 11596 12390 13390 13390 14971 21172 25930 29942
MFR# PIPE SIZE
CSA
MAX
PRESSURE DROP IN W.C.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 2 3 4
RV52 1/2 or 3/4 705 237 335 411 473 530 580 627 669 710 749 1060 1298 1498
RV53 3/4 or 1 1113 340 480 588 679 759 831 898 959 1019 1072 1517 1857 2146
RV61 1 or 11/4 1724 594 840 1058 1190 1329 1456 1574 1682 1784 1881 2730 3345 3862
RV81 11/4 or 11/2 3919 1223 1727 2116 2444 2732 2992 3232 3455 3666 3864 5463 6691 7726
RV91 2 or 21/2 5133 1900 2687 3292 3799 4249 4654 5028 5375 5701 6010 8499 10408 12019
RV111 21/2 or 3 11756 4298 6079 7445 8597 9612 10530 11373 12159 12895 13436 22154 23295 26899
RV131 4 7420 10494 12853 14841 16593 18176 19632 20988 22261 23466 33186 40644 46932
Propane Gas Chart*
Straight thru fow RV regulator (Appliance or combustion regulators)
Capacity Table in 1000s of BTUs of Undiluted Propane Gas (1.5 Specifc Gravity 14.65 psia 60F)
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
26
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
325-5ALX
Attention: To comply with
the ANSI Z21-80 Standard
for Line Pressure Regulators,
installations exceeding 2-psi
nominal require a tested
and approved over-pressure
protection device (OPD) for
use with the regulator.
(Over-pressure protection is not
required for supply pressures
up to and including 2-psi.)
325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
Features:
cSA certifed for up to 5-psi inlet pressure.
Over-pressure protection device (OPD) to limit downstream pressure in case
of regulator failure.
Maxitrol OPD approved and tested with the regulator.
Regulators or OPDs can be ordered as separate items or as a factory assembled unit.
Self-aligning valve with lever action for dead end regulator lockup.
Optional vent limiter eliminates the need to run vent piping to an outside area.
Benefts:
Meets new ANSI standard Z21-80 for line pressure regulators for use on piping
systems such as cSST or semi-rigid copper tubing up to 5-psi.
OPD provides required downstream over-pressure protection for supply pressures
in excess of 2-psi.
Pounds to inches regulator provides precise control from pilot fows to full
regulator capacity.
Meets many utility specifcations.
Outlet Pressure Range
(all models)
Certifed spring 7-11 in W.C.
MFR#
BODY
SIZES
QTY. PER
CASE WEBB#
325-3L-12 1/2 50 252139
325-3L-38 3/8 50 252138
325-5AL-1 1 18 252142
325-5AL-12 1/2 18 252140
325-5AL-34 3/4 18 252141
325-7AL-114 11/4 4 224151
325-7AL-112 11/2 4 224152
MFR# DESCRIPTION WEBB#
MXT325-3L-38LP
LP REG 3/8" IPS AT 11"WC W/
VNT LIMITER
432833
MXT325-3L-12LP
LP REG 1/2" IPS AT 11"WC W/
VNT LIMITER
432832
MXT325-5AL-12LP
LP REG 1/2" IPS AT 11"WC
W/VNT LIMITER
432834
MXT325-5AL-34LP
LP REG 3/4" IPS AT 11"WC W/
VNT LIMITER
432836
MXT325-5AL-1LP
LP REG 1" IPS AT 11"WC W/
VNT LIMITER
432835
MXT325-7AL-114LP
LP REG 1-1/4" IPS AT
11"WC W/VNT LIMITER
432838
MXT325-7AL-112LP
LP REG 1-1/2" IPS AT
11"WC W/VNT LIMITER
432837
Natural Gas Chart
Model 325L Series 2 PSI Max Inlet Capacity Table in SCFH of Natural Gas
(0.64 Specifc Gravity 14.65 psia 60F)
MFR# PIPE SIZE
OUTLET
PRESSURE
1/2 PSI
INLET
3/4 PSI
INLET
1 PSI
INLET
11/2 PSI
INLET
2 PSI
INLET
MAX LOAD
MULTIPLE
APPLIANCES
MAX
INDIVIDUAL
APPLIANCE LOAD
325-3L 3/8 or 1/2
7 W.C. 145 200 250 250 250 250 140
10 W.C. 110 180 230 250 250 250 140
325-5AL 1/2
7 W.C. 335 425 425 425 425 425 300
10 W.C. 250 420 425 425 425 425 300
325-5AL 3/4 or 1
7 W.C. 335 475 550 550 550 550 300
10 W.C. 250 420 535 550 550 550 300
325-7AL 11/4 or 11/2
7 W.C. 690 970 1000 1000 1000 1000 900
10 W.C. 520 860 1000 1000 1000 1000 900
Special Order For 325 Series
With OPD
Vent Limiter
12A09
Accessories
Vent Limiting Means
Ball check permits free inhalation for fast regulator diaphragm response on opening cycle,
but limits gas escapement to within ANSI standards should a diaphragm rupture.
MFR# DESCRIPTION WEBB#
12A04 Optional Automatic Vent Limiting Device for RV48, RV52, RV53, RV61 77527
12A06 Optional Vent Limiting Orifice for RV48, RV52, RV53, RV61 192793
12A09
Optional Automatic Vent Limiting Device for 325-3, 325-3L, 325-3LX, OPD48, OPD600,
325-3L47 (reg. only), 325-3L48 (reg. & OPD), 325-5AL48 (OPD only), 325-5AL600 (OPD only)
109780
12A39
Optional Automatic Vent Limiting Device for 325-5A, 325-5AL, 325-ALX,
325-5AL48 (reg. only), 325-5AL600 (reg. only)
192794
12A49 Optional Automatic Vent Limiting Device for 325-7L, 325-7AL 436746
13A15 Outdoor Vent Protector for 3L and 5AL 246350
13A25 Outdoor Vent Protector for 3L and 5AL 433028
7 WC Less Vent Limiter 11 WC With Vent Limiter
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
27
SECTION
1
325 Series L-Model Line Regulators & OPDs, #2 Inlet Regulators
Natural Gas Chart
Model 325 With OPD Capacity Table in SCFH of Natural Gas
(0.64 Specifc Gravity 14.65 psia 60F)
MFR# PIPE SIZE
OUTLET
PRESSURE
1/2 PSI
INLET
3/4 PSI
INLET
1 PSI
INLET
5 PSI
INLET
MAX LOAD
MULTIPLE
APPLIANCES
MAX
INDIVIDUAL
APPLIANCE LOAD
325-3L47 3/8
7 W.C. 125 125 125 125 125 125
10 W.C. 100 125 125 125 125 125
325-3L47 1/2
7 W.C. 125 125 125 125 125 125
10 W.C. 105 125 125 125 125 125
325-3L48 1/2
7 W.C. 160 200 200 200 200 200
10 W.C. 120 200 200 200 200 200
325-5AL48 1/2
7 W.C. 235 235 235 235 235 235
10 W.C. 235 235 235 235 235 235
325-5AL48 3/4
7 W.C. 320 320 320 320 320 320
10 W.C. 245 320 320 320 320 320
325-5AL600 3/4
7 W.C. 345 425 425 425 425 425
10 W.C. 260 425 425 425 425 425
325-5AL600 1
7 W.C. 375 465 465 465 465 465
10 W.C. 285 465 465 465 465 465
Propane Gas Chart*
Model 325 with OPD Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
MFR# PIPE SIZE
OUTLET
PRESSURE
1/2 PSI
INLET
3/4 PSI
INLET
1 PSI
INLET
5 PSI
INLET
MAX LOAD
MULTIPLE
APPLIANCES
MAX
INDIVIDUAL
APPLIANCE LOAD
325-3L47 3/8
7 W.C. 196 196 196 196 196 196
10 W.C. 157 196 196 196 196 196
325-3L47 1/2
7 W.C. 196 196 196 196 196 196
10 W.C. 165 196 196 196 196 196
325-3L48 1/2
7 W.C. 251 313 313 313 313 313
10 W.C. 188 313 313 313 313 313
325-5AL48 1/2
7 W.C. 368 368 368 368 368 368
10 W.C. 368 368 368 368 368 368
325-5AL48 3/4
7 W.C. 502 502 502 502 502 502
10 W.C. 384 502 502 502 502 502
325-5AL600 3/4
7 W.C. 541 666 666 666 666 666
10 W.C. 408 666 666 666 666 666
325-5AL600 1
7 W.C. 588 729 729 729 729 729
10 W.C. 447 729 729 729 729 729
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
MFR# PIPE SIZE
OUTLET
PRESSURE
1/2 PSI
INLET
3/4 PSI
INLET
1 PSI
INLET
11/2 PSI
INLET
2 PSI
INLET
MAX LOAD
MULTIPLE
APPLIANCES
MAX
INDIVIDUAL
APPLIANCE LOAD
325-3L 3/8 or 1/2
7 W.C. 227 313 392 392 392 392 219
10 W.C. 172 282 361 392 392 397 219
325-5AL 1/2
7 W.C. 525 666 666 666 666 666 470
10 W.C. 392 658 666 666 666 666 470
325-5AL 3/4 or 1
7 W.C. 525 745 862 862 862 862 470
10 W.C. 392 658 839 862 862 862 470
325-7L 11/4 or 11/2
7 W.C. 1082 1520 1567 1567 1567 1567 1410
10 W.C. 815 1348 1567 1567 1567 1567 1410
Propane Gas Chart*
Model 325L Series 2 PSI Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
28
victormfg.com
Regulators
1
SECTION
Gas Equipment Catalog
RV12
RV20
RV47 & CV47
RV48
Rubber Seat Poppet Design Appliance Regulators
RV12, RV20, RV47 & CV47 and RV48
Main burner and pilot applications
MFR# PIPE SIZES CAPACITIES TO
INLET
PRESSURES TO
OUTLET
PRESSURES
RV12 1/8 25 CFH 1/2 psi (35 mbar)
1.0 to 12 W.C.
RV20 1/4 & 3/8 65 CFH 1/2 psi
RV47 & CV47 3/8 & 1/2 125 CFH
1/2 psi (35 mbr)
RV48 1/2 & 3/4 250 CFH
MFR# BODY SIZES QTY. PER CASE WEBB#
RV20L-38 3/8 100 185902
RV47CL-12 1/2 50 185903
RV47CL-38 3/8 50 188932
RV47L-12 1/2 50 197256
RV47L-38 3/8 50 188933
RV48CL-12 1/2 50 185905
RV48CL-34 3/4 50 185904
RV48L-12 1/2 50 185907
RV48L-34 3/4 50 185906
MFR#
BODY
SIZES
QTY. PER
CASE
STD.
SPRING SET POINT WEBB#
RV20L-38 3/8" 100 3-5" wc 4" 185902
RV48CL-12 1/2" 50 None fxed 4 or 10" 185903
RV47CL-38 3/8" 50 None fxed 4 or 10" 188932
RV47L-12 1/2" 50 4-12" 11" 197256
RV47L-38 3/8" 50 4-12" 11" 188933
RV48CL-12 1/2" 50 None fxed 4 or 10" 185905
RV48CL-34 3/4" 50 None fxed 4 or 10" 185904
RV48L-12 1/2" 50 4-12" 11" 185907
RV48L-34 3/4" 50 4-12" 11" 185906
RV48-12 1/2" 50 3-6" 4" 77528
RV48-34 3/4" 50 3-6" 4" 77529
MFR# PIPE SIZE
MAX CAPACITY
AT .3 W.C.
PRESSURE DROP
SUGGESTED
MAX SUPPLY
FOR MAIN
BURNER ONLY
SUGGESTED MAX
SUPPLY FOR MAIN
BURNER ONLY
AND PILOT
MAX INDIVIDUAL
LOAD WITH FIXED
ORIFICE VENT
LIMITER
MAX INDIVIDUAL
LOAD WITH BALL
CHECK VENT
LIMITER
RV12 1/8 15 30 25 20
RV20 1/4 or 3/8 30 65 50 30
RV47 3/8 or 1/2 30 125 90 40 90
RV47C 3/8 or 1/2 60 125 125 40 125
RV48 1/2 130 230 230 40 160
RV48 3/4 150 230 250 40 160
RV48C 1/2 130 400 275 40 160
RV48C 3/4 150 400 275 40 160
Natural Gas Chart
Poppet RV Regulator (Appliance Regulators) Capacity Table in SCFH of Natural Gas
(0.64 Specifc Gravity 14.65 psia 60F) (Min. Capacity on all models is 150 btu/hr)
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
R
E
G
U
L
A
T
O
R
S
&
A
C
C
E
S
S
O
R
I
E
S
1
Regulators
29
SECTION
1
Propane Gas Chart*
Poppet RV Regulator (Appliance Regulators) Capacity Table in 1000s of BTUs of Undiluted Propane Gas
(1.5 Specifc Gravity 14.65 psia 60F)
MFR# PIPE SIZE
MAX CAPACITY
AT .3 W.C.
PRESSURE DROP
SUGGESTED
MAX SUPPLY
FOR MAIN
BURNER ONLY
SUGGESTED MAX
SUPPLY FOR MAIN
BURNER ONLY
AND PILOT
MAX INDIVIDUAL
LOAD WITH FIXED
ORIFICE VENT
LIMITER
MAX INDIVIDUAL
LOAD WITH BALL
CHECK VENT
LIMITER
RV12 1/8 23 47 39 31
RV20 1/4 or 3/8 47 102 78 47
RV47 3/8 or 1/2 47 196 141 63 141
RV47C 3/8 or 1/2 94 196 196 63 196
RV48 1/2 204 361 361 63 251
RV48 3/4 235 361 392 63 251
RV48C 1/2 204 627 392 63 251
RV48C 3/4 235 627 392 63 251
* Propane chart is a mathematical extrapolation using 0.63 correction factor and 2,488 btu/hr = 1 cubic foot from NFPA-58, 2008.
MFR# DESCRIPTION USE WITH REGULATOR WEBB #
MXTR325C10-1022 Spring Red 10-22 325-3 325-3 185891
MXTR325C10-1530 Spring Yellow 15-30 325C 325-3 197075
MXT325E-10A-1022 Spring Red 10-22 325-5A 325-5A 110108
MXTR325E10-26A Springs 2 to 6 lbs 325-5A 309740
MXTR325E10-412 Spring Violet 4-12 325-5A 185893
MXTR325E10-P12 Spring Tagged 325-5A 185894
MXTR4810-512 Spring Blue 5-12 RV48 RV48 185889
MXTR6110-1022 Maxitrol Spring 10 to 12 RV61 254238
MXTR8110-1022 Spring Red RV81/210D 192815
MXTR8110-1530 Spring Yellow 15-30 210D RV81/210D 196945
MXTR8110-2042 Spring Black 20-42 RV81/210D 185897
MXTR8110-412 Spring Violet 4-12 RV RV81/210D 196956
MXTR8110-512 Spring Blue 5-12 RV81/210D 185898
MXTR8110-515 Spring Green 5-15 RV881 210 RV81/210D 196987
MXTR9110-1022 Spring Red 10-22 RV91/210E 185899
MXTR9110-1530 Spring Yellow 15-30 210E RV91/210E 196947
MXTR9110-412 Spring Violet 4-12 Spring RV91/210E 199275
MXTR9110-512 Spring Blue 5-12 RV91/210E 309737
Rubber Seat Poppet Design Appliance Regulators
RV12, RV20, RV47 & CV47 and RV48
Victor/F.w. Webb offers webbConnect!
you can order, check current pricing
and inventory 24/7!
30
victormfg.com
Cylinder & Service Valves
2
SECTION
Gas Equipment Catalog
Heavy Duty Cylinder Valves
for Vapor Withdrawal
This heavy duty cylinder valve is designed for vapor withdrawal of DOT cylinders up to
100 lbs. propane capacity. It is used in domestic hookups, with RVs and as a heavy duty
barbeque cylinder valve.
9103D11.6
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
FIXED LIQUID
LEVEL VENT
VALVE STYLE
DIP TUBE
LENGTH
WITH
DEFLECTOR
PRESSURE
RELIEF
VALVE
SETTING
FOR USE IN
CYLINDERS
WITH PROPANE
CAPACITY UP TO
9103D10.6
3/4 M. NPT
F. POL
CGA 510
Knurled
10.6
375 PSIG 100 lbs.
9103D11.6 11.6
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
ACCESSORIES
WEBB#
PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG POL PLUG
9103D10.6
12.7 20.3 29.0 41.3 N970P
162726
9103D11.6 162727
Cylinder Valve for RV and Small ASME
System Vapor Withdrawal
Designed especially for vapor withdrawal service in small ASME containers with surface
area up to 23.8 square feet. UL fow capacity is 645 CFM/air, per NFPA 58.
Cavagna OPD Valve
Type 1 valves intended for DOT cylinders up to 40 lbs. LP Gas capacity. This valve has
a vapor service outlet, relief valve, captive fxed liquid level gauge, and an overfll
prevention device.
Outlet thread:
Dip tube length:
Setting pressure:
Flow limiter:
Plastic cap:
Inlet thread:
Pressure relief valve:
Gas type:
Packaging:
Availability:
Type 1 ACME and POL
4.0 inches
375 PSI
No
No
3/4
Yes
LP-Gas
28
Yes
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
FIXED
LIQUID
LEVEL
VENT VALVE
STYLE
PRESSURE
RELIEF
VALVE
SETTING
FOR USE IN
CYLINDERS
WITH
PROPANE
CAPACITY
UP TO
FLOW
CAPACITY
SCFM/AIR WEBB#
9106CO 3/4 M. NPT F. POL CGA 510 None 312 PSIG ASME Tanks* 645 186998
* Surface area up to 23.8 square feet.
9106CO
MFR# SIZE WEBB#
VCT80-8169 20# 395314
VCT80-9-890-8128 30# 401280
VCT80-9-890-8185 40# 399370
VCT80-8169
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Cylinder & Service Valves
31
2
SECTION
Service Valves for ASME and DOT Containers
or Fuel Line Applications
Designed especially for vapor withdrawal service on ASME and DOT containers or in fuel
line applications. Since none of these valves have an integral pressure relief valve, they may only be
used as an accessory valve on containers that have an independent pressure relief valve suffcient for
that containers capacity.
Dual Cylinder Valve for Simultaneous
Liquid and Vapor Withdrawal
The dual cylinder valve was designed especially for industrial uses. It increases the
cylinders fexibility by permitting DOT cylinders up to 100 lbs. propane capacity to be used
interchangeably or simultaneously for either liquid or vapor withdrawal.
MFR#
BONNET
STYLE
CONTAINER
CONNECTION
SERVICE
CONNECTION
FIXED
LIQUID
LEVEL
VENT
VALVE
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#
PRESSURE DROP ACROSS VALVE
10 PSIG 25 PSIG 50 PSIG 100 PSIG
9101C1
Standard
3/4 M. NPT
F. POL
CGA 510
No 8.8 12.4 15.8 21.7 186993
9101DT11.1
Yes 8.6 12.7 16.3 22.3
273828
9101DT11.7 273829
9101R11.7 MultiBonnet Yes 7.6 11.7 15.2 20.6 162724
MFR#
CONTAINER
CONNECTION
SERVICE CONNECTION FIXED LIQUID
LEVEL VENT
VALVE STYLE
LIQUID
WITHDRAWAL
TUBE LENGTH VAPOR LIQUID
8556 3/4 M. NPT F. POL CGA 510 CGA 555 None 44
* Closing fows based on 3/8 O.D. withdrawal tube 44 long or less attached.
IMPORTANT: 1/4 O.D. pigtails or POL connections for 1/4 O.D. pigtails should not be used with these valves.
NOTES: To ensure proper functioning and maximum protection from excess fow valves, the cylinder valve should be fully opened and backseated when in use.
These valves incorporate an excess fow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess fow valves.
* To ensure proper functioning and maximum protection from excess fow valves, the cylinder valve should be fully opened and
backseated when in use.
NOTE: These valves incorporate an excess fow valve. Refer to L-500/Section F, for complete information regarding selection,
operation and testing of excess fow valves.
MFR#
PRESSURE
RELIEF
VALVE
SETTING
FOR USE
IN CYLINDERS
WITH PROPANE
CAPACITY UP TO
APPROXIMATE FILLING
RATE LIQUID FLOW, GPM CLOSING FLOW (LP-GAS)*
WEBB#
PRESSURE DROP
ACROSS VALVES VAPOR
LIQUID
10
PSIG
25
PSIG
50
PSIG
100
PSIG
25 PSIG
INLET
100 PSIG
INLET
9107K8A 375 PSIG 100 lbs. 3.3 5.4 7.7 11.1
525
SCFH
1,000
SCFH
1.7 GPM 162728
MFR#
PRESSURE
RELIEF
VALVE
SETTING
FOR USE IN
CYLINDERS
WITH PROPANE
CAPACITY UP TO
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
LIQUID CLOSING
FLOW* (LP-GAS) WEBB#
PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
8556 375 PSIG 100 lbs. 6.6 10.0 14.5 21.0 2.3 GPM 189194
Cylinder Valve for Liquid Withdrawal
Equipped with excess fow valves and liquid withdrawal tubes, they are designed for liquid
withdrawal of DOT cylinders up to 100 lbs. propane capacity. They are most often used
with heavy BTU loads found in industrial uses.
9107K8A
With Dip Tube
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
FIXED LIQUID
LEVEL VENT
VALVE STYLE
DIP TUBE
LENGTH WITH
DEFLECTOR
LIQUID
WITHDRAWAL
TUBE LENGTH
9107K8A 3/4 M. NPT CGA 555 Knurled 11.6 44
NOTE: These valves incorporate an excess fow valve. Refer to L-500/Section F, for complete information regarding selection, operation and testing of excess fow valves.
9101R11.7 9101C
32
victormfg.com
Cylinder & Service Valves
2
SECTION
Gas Equipment Catalog
Service Valve for DOT Fork Lift Containers
Designed especially for vapor or liquid withdrawal service on DOT fork lift containers. Valves
with 1.5 GPM closing fow are for use in small and medium size lift truck applications, while
those with 2.6 GPM closing fow are for large lift trucks and gantry crane type vehicles. Since
none of these valves have an integral pressure relief valve, they may only be used as an accessory valve
on containers that have an independent pressure relief valve suffcient for that cylinders capacity.
The integral excess fow valve found in all these service valves helps prevent excessive
product loss in the event of fuel line rupture.
When installed for liquid withdrawal, the 9101P6 Series has provisions for attachment
of a liquid withdrawal tube. The 9101P5 Series must be installed in containers that have
provisions for a separate liquid withdrawal.
Service Valves for ASME
Motor Fuel Containers
Designed specifcally for vapor or liquid withdrawal service on ASME motor fuel containers.
Since none of these valves have an integral pressure relief valve, they may only be used as an accessory
valve on containers that have an independent pressure relief valve suffcient for that containers capacity.
The integral excess fow valve found in all these service valves helps prevent excessive
product loss in the event of fuel line rupture.
When installed for liquid withdrawal, the 9101H6 has provisions for attachment of
a liquid withdrawal tube. All other valves must be installed in containers that have
provisions for a separate liquid withdrawal.
9101P5
9101P6
9101H6
9101H5
9101Y5H
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
LIQUID
WITHDRAWAL
CONNECTION
CLOSING FLOW (LP-GAS)
VAPOR
LIQUID
(GPM)
25 PSIG
INLET (SCFH)
100 PSIG
INLET (SCFH)
9101P5
3/4 M. NPT 3/8 M. NPT
None
430 900 1.5
9101P5H 550 1050 2.6
9101P6
1/4 NPT
430 900 1.5
9101P6H 550 1050 2.6
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM ACCESSORIES
WEBB#
PRESSURE DROP ACROSS VALVES ACME CHECK CONNECTORS
10 PSIG 25 PSIG 50 PSIG 100 PSIG MALE FEMALE CAP
9101P5
5.0 7.6 10.7 14.9
7141M 7141F
7141M-40
or
7141FP
9101P5H
9101P6
4.5 7.2 10.3 14.8
9101P6H
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
LIQUID
WITHDRAWAL
CONNECTION
CLOSING FLOW (LP GAS)
WEBB#
VAPOR
LIQUID
GPM
25 PSIG
INLET (SCFH)
100 PSIG
INLET (SCFH)
9101H5*
3/4 M. NPT
* SAE Flare
None 765** 1300** 3.6** 162499
9101H6* 1/4 NPT 550**** 1050**** 2.6**** 189199
9101Y5H*
60 Angle
* SAE Flare
None 550** 1050** 3.6** 162500
*Heavy-duty models. **Based on 3/8 O.D. pigtail, 20 long or less, connected to valve outlet. For greater lengths the pigtail must have a larger O.D. ***Same as (**) .
In addition, 1/4 O.D. pigtails or POL connections for 1/4 O.D. should not be used with this valve. ****Based on 3/8 O.D. pigtail: 20 long or less, connected to valve
outlet. Also based on 1/4 pipe size dip tube, 42 long or less, attached to special inlet connection. For longer pigtail lengths, the diameter of the pigtail must be increased.
162720
162721
186995
190685
To ensure proper functioning and maximum protection from excess fow valves, the cylinder valve should be fully opened and backseated when in use.
To ensure proper functioning and maximum protection from excess fow valves, the cylinder valve should be fully opened and backseated when in use.
33 TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Multivalve Assemblies
33
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
ASME Multivalves
are designed for use in single opening ASME containers equipped with
a 21/2 M. NPT riser. They can be used with underground ASME containers up to 639 sq.
ft. surface area, and above ground ASME containers up to 192 sq. ft. surface area. A separate
opening is required for liquid withdrawal. The MultiBonnet
is standard on
this valve. MultiBonnet
have not integral pressure relief valves, they can be used on any ASME container with an independent relief device suffcient
for that tanks capacity.
* Dip tube not installed, may be cut by customer to desired length.
For specifc repair parts, see the end of this section.
G8475RW
8593AR16.0
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
G8475RV
42 72 98 125
G8475RW
MFR#
APPROXIMATE FILLING RATE LIQUID FLOW, GPM
WEBB#
PRESSURE DROP ACROSS VALVES
10 PSIG 25 PSIG 50 PSIG 100 PSIG
8593AR16.0 42 72 98 125 162498
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
FILLING
CONNECTION
VAPOR
EQUALIZING CONNECTION
FLOAT
GAUGE
FLANGE
OPENING
CONNECTION
SIZE
UL LISTED
CLOSING FLOW
G8475RV
21/2 F. NPT F. POL CGA 510 13/4 M. Acme 11/4 M. Acme
4200 CFH
at 100 PSIG
Fits Junior Size
G8475RW
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
FILLING
CONNECTION
VAPOR
EQUALIZING
CONNECTION
FIXED
LIQUID
LEVEL
VENT
VALVE
STYLE
DIP
TUBE
LENGTH
FOR USE IN
CONTAINERS
WITH
SURFACE
AREA UP TO:
CONNECTION
SIZE
UL
LISTED
CLOSING
FLOW
8593AR16.0 11/2 M. NPT F. POL CGA 510 13/4 M. Acme 11/4 M. Acme
4200 CFH
at 100 PSIG
Knurled 16* **
MFR#
FIXED
LIQUID LEVEL
VENT VALVE
STYLE
DIP TUBE
LENGTH
PRESSURE RELIEF VALVE
FOR USE IN
*CYLINDERS WITH
SURFACE AREA
UP TO WEBB# SETTING MFR#
FLOW CAPACITY
UL ASME
G8475RV
Knurled 30* 250 PSIG
M3131G
2020
SCFM/air
1939
SCFM/air
83 sq. ft. Above Ground
276 sq. ft. Underground
187104
G8475RW MV3132G
3995
SCFM/air
n/a
192 sq. ft. Above Ground
639 sq. ft. Underground
190680
34
victormfg.com
Multivalve Assemblies
2
SECTION
Gas Equipment Catalog
DOT Multivalves
for Vapor Withdrawal
These Multivalves
6532R12.0 162735
6542A12.0
23 32 46
373827
6542R12.0 162737
6533A11.7
11 16 23
162729
6533R11.7 162736
6543A11.1
23 32 46
162730
6543R11.1 162738
6543A11.7 162731
6543R11.7 162739
6543AT10.3 273821
6543AT11.7 275093
36
victormfg.com
Multivalve Assemblies
2
SECTION
Gas Equipment Catalog
MFR# BONNET STYLE APPLICATION
CONTAINER
CONNECTION
SERVICE
CONNECTION
FILLING
CONNECTION
FIXED LIQUID LEVEL
VENT VALVE STYLE
6532A12.0 Standard
ASME*
3/4 M. NPT
F.POL CGA 510 13/4 M. Acme Knurled
6532R12.0 MultiBonnet
6542A12.0 Standard
1 M. NPT
6542R12.0 MultiBonnet
6533A11.7 Standard
DOT
3/4 M. NPT
6533R11.7 MultiBonnet
6543A11.1 Standard
1 M. NPT
6543R11.1 MultiBonnet
6543A11.7 Standard
6543R11.7 MultiBonnet
MFR#
DIP TUBE LENGTH
WITH DEFLECTOR
PRESSURE RELIEF
VALVE SETTING
FOR USE IN CYLINDERS
WITH PROPANE CAPACITY**
FOR USE
IN CONTAINERS
WITH SURFACE
AREA UP TO*** WEBB#
6532A12.0
12.0 250 PSIG
43 sq. ft.
6532R12.0 162735
6542A12.0
53 sq. ft.
373827
6542R12.0 162737
6533A11.7
11.7
375 PSIG 420 lbs. Propane
162729
6533R11.7 162736
6543A11.1
11.1
162730
6543R11.1 162738
6543A11.7
11.7
162731
6543R11.7 162739
DOT and ASME Multivalves
for Vapor Withdrawal (continued)
* UL rated fow capacities are 6532A 12.0-1180 SCFM/air, 6542A 12.0-1530 SCFM/air. ** Per CGA Pamphlet S-1.1. *** From NFPA 58, Appendix D.
ASME Multivalves
have no integral pressure relief valves, they can be used on any ASME container with an
independent relief device suffcient for that tanks capacity.
7556R12.0
MFR#
CONTAINER
CONNECTION
SERVICE
CONNECTION
VAPOR
EQUALIZING CONNECTION
CONNECTION
SIZE
UL LISTED
CLOSING FLOW
7556R12.0 3/4 M. NPT F. POL CGA 510 11/4 M. Acme 4200 CFH at 100 PSIG
7556ZT Special/Thread Connection O-Ring
MFR#
FIXED LIQUID LEVEL
VENT VALVE STYLE
DIP TUBE
LENGTH
FOR USE IN CONTAINERS
WITH SURFACE UP TO WEBB#
7556R12.0 Knurled 12 * 162742
7556ZT
37 TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
37
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Fully Internal Pop-Action Pressure Relief
Valves for Transport and Delivery Trucks
Designed specifcally for use as a primary relief valve in ASME transports and delivery
trucks with 2 and 3 NPT couplings.
Fully Internal Pop-Action Pressure Relief
Valves for Motor Fuel Containers
8543 Series relief valves are designed for use as a primary relief valve in larger ASME motor
fuel containers such as on buses, trucks and construction equipment.
8544 Series relief valves are designed for use as a primary relief valve in smaller ASME and
DOT motor fuel containers such as on tractors, lift trucks, cars and taxicabs.
A8434G
8544T
MFR#
START TO
DISCHARGE
SETTING
PSIG
CONTAINER
CONNECTION
OVERALL
HEIGHT
(APPROX.)
HEIGHT
ABOVE
COUPLING
(APPROX.)
UL ASME
SUITABLE FOR
TANKS WITH
SURFACE
AREA UP TO*
PROTECTIVE
CAP
(INCLUDED) WEBB#
(AT 120% OF
SET PRESSURE)
A8434G 250 2 M. NPT 91/16 1/2 3700 3456 175 sq. ft. A8434-11B 187081
A8436G 250 3 M. NPT 17 3/4 10210 9598 602 sq. ft. A8436-11B 162575
MFR#
CONTAINER
TYPE
START TO
DISCHARGE
SETTING PSIG
CONTAINER
CONNECTION
M. NPT
OVERALL
HEIGHT
(APPROX.)
HEIGHT
ABOVE
COUPLING
(APPROX.)
8544G
ASME
250
1
57/16 7/8
8543G 11/4
8544T 312 1
8544K DOT/ASME 375 1
8544GT ASME 250 1
8544KT DOT/ASME 375 1
MFR#
HEX
WRENCHING
SECTION
FLOW CAPACITY
SCFM/AIR***
PROTECTIVE
CAP
(INCLUDED)
ACCESSORIES
WEBB#
UL ASME
PIPEAWAY
ADAPTER
(AT 120% OF SET
PRESSURE)
8544G 15/16 1020 936 7544-41 7544-11A* 162757
8543G 111/16 1465 1400 7543-40C 7543-10** 189192
8544T 15/16 1282 1158 7544-41 7544-11A 189193
8544K 15/16 1545*** 7544-41 7544-11A 162758
8544GT 15/16 1020 936 7544-41 7544-11A 273823
8544KT 15/16 1545*** 7544-41 7544-11A 273824
* Per NFPA Pamphlet #58, Appendix D. Area shown is for UL or ASME fow ratingwhichever is larger.
T = Threadsealent
*1 M.NPT outlet connection. **11/4 M.NPT outlet connection. ***Rating also applies to DOT requirements. ****Flow
rates shown are for bare relief valves. Adapters and pipeaway will reduce fow as discussed in forewording information.
38
victormfg.com
Pressure Relief Valves & Relief Valve Manifolds
2
SECTION
Gas Equipment Catalog
Fully Internal Pop-Action Pressure
Relief Valve for DOT Fork Lift Cylinders
Designed specifcally for use as a primary relief valve on forklift cylinders, the 8545AK
reduces the possibility of improper functioning of the relief mechanism due to foreign
material build up. All guides, springs, stem and adjusting components are located inside
the cylinder removed from the direct exposure of foreign materials and debris from
the atmosphere.
8545AK With Protective Cap
MFR#
CONTAINER
TYPE
START TO
DISCHARGE
SETTING PSIG
CONTAINER
CONNECTION
M. NPT
FLOW CAPACITY
SCFM/AIR**
ACCESSORIES
(ORDER SEPARATELY)
WEBB#
PROTECTIVE
CAP
DEFLECTORS***
(ECII
RATED AT
480 PSIG)
45
ELBOW
90
ELBOW
8545AK DOT 375 3/4 400* 7545-40 7545-14A 7545-12 162759
* Classifed by U.L. in accordance with Compressed Gas Association Pamphlet S-1.1 Pressure Device Standards for Cylinders. Meets requirements for use on
DOT containers with 262 pounds or less weight of water or 109 pounds or less of LP-Gas.
** Flow rates are shown for bare relief valves. Adapters and pipeaways will reduce fow as discussed in forewording information.
*** Order protective cap #8545-41 or 7545-40.
Semi-Internal Pop-Action
Pressure Relief Valve for ASME Containers
Designed specifcally for use as a primary relief valve on ASME containers such as 250, 500
and 1,000 gallon tanks. Underwriters Laboratories lists containers systems on which these
types of valves are mounted outside the hood without additional protection, if mounted
near the hood and ftted with a protective cap.
7583G
MFR#
START TO
DISCHARGE
SETTING PSIG
CONTAINER
CONNECTION
M. NPT
OVERALL
HEIGHT
(APPROX.)
HEIGHT
ABOVE
COUPLING
(APPROX.)
WRENCH HEX
SECTION
7583G
250
3/4 83/16 17/16 13/4
8684G 1 93/8 19/16 17/8
8685G 11/4 111/16 111/16 23/8
MFR#
FLOW CAPACITY SCFW/AIR
SUITABLE FOR
TANKS WITH
SURFACE AREA
UP TO
PROTECTIVE
CAP
(INCLUDED) WEBB#
UL ASME
(AT 120% OF SET PRESSURE)
7583G 1980 1806 80 sq. ft. 7583-40X 162747
8684G 2620 2565 113 sq. ft. 8684-40 162749
8685G 4385 4035 212 sq. ft. 7585-40X 162750
39 TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
39
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Semi-Internal Pop-Action Pressure
Relief Valve for Large Storage Containers
Designed specifcally for use as a primary relief valve on large stationary storage containers,
these low profle relief valves are generally mounted in half couplings. However, they are
designed so that the inlet ports clear the bottom of a full 2 coupling. This assures that the
relief valve should always be capable of maximum fow under emergency conditions.
7534G
7534-20
7534-40
MFR#
START TO
DISCHARGE
SETTING PSIG
CONTAINER
CONNECTION
FLOW CAPACITY
SCFM/AIR*
SUITABLE FOR
TANKS WITH
SURFACE AREA
UP TO**
ACCESSORIES
WEBB#
UL ASME
PROTECTIVE
CAP
PIPEAWAY
ADAPTER
(AT 120% OF SET
PRESSURE)
7534G 250 2 M. NPT 11675 10422 708 sq. ft. 7534-40 7534-20*** 162574
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce fow as discussed in the forewording information.
** Per NFPA Pamphlet #58, Appendex D. Area shown is for UL or ASMEwhichever is larger.
*** 3 F.NPT outlet connection.
External Pop-Action Supplementary
Pressure Relief Valves for Small
Containers and DOT Cylinders
Designed for use as a supplementary relief valve on small ASME above ground and
underground containers. They may also be used as a primary or secondary relief device
on DOT cylinders, or as hydrostatic relief valves.
All working components of these relief valves are outside the container connection,
so the valves must be protected from physical damage.
MFR# CONTAINER TYPE
START TO
DISCHARGE
SETTING PSIG
CONTAINER
CONNECTION
M. NPT
OVERALL HEIGHT
(APPROX.)
WRENCH HEX
SECTION
3127G
ASME 250
1/4 131/32 7/8
3129G 1/2 219/32 11/8
3127K
DOT 375
1/4 131/32 7/8
3129K 1/2 219/32 11/8
* Flow rates shown are for bare relief valves. Adapters and pipeaways will reduce fow.
3127 Series 3127G
MFR#
FLOW CAPACITY
SCFM/AIR*
SUITABLE FOR
TANKS WITH
SURFACE AREA
UP TO*
ACCESSORIES
WEBB#
UL ASME
PROTECTIVE
CAP
PIPEAWAY ADAPTER
(AT 120% OF SET PRESSURE) MFR#
OUTLET
SIZE
3127G 295
7545-40
162420
3129G 465 3129-10 1/2 F. NPT 162429
3127K
187092
AA3126L250 23 sq. ft. (f) 187093
3131G 85 sq. ft. 3131-40 (g) 162436
AA3130UA250 249 sq. ft. (f) AA3130-40P AA3131-10 1 F. NPT 187095
W3132G 154 sq. ft.
3132-54 (g)
3132-10 11/4 F. NPT
3133-11
162444
3132G 200 sq. ft.
162442
MV3132G 190 sq. ft. 188588
3135G 300 sq. ft. 3135-54 (g) 3135-10
2 F. NPT
162447
AA3135UA250 1010 sq. ft. (f) AA3135-40PR AA3135-10 190683
3133G 320 sq. ft. 3133-40 (g) 162446
A3149G 613 sq. ft. 3149-40 (h) Included (j) 162572
AA3130UA265 261 sq. ft. (f) AA3130-40P AA3131-10 1 F. NPT 189239
(b) Not UL or ASME rated. .059 sq. in. effective area.
(c) Not UL or ASME rated. ECII
rated at 120% of set pressure.
(d) Rated at 110% of set pressure.
(f ) Per ANSI K61.1-1972. Appendix A
(g) Cap supplied with chain.
(h) Outlet 31/2-8N (F) thread, will accept 3 M. NPT pipe thread.
( j) Weep hole defector is Part No. A3134-11B.
External Pop-Action Pressure Relief
Valve for ASME Containers and
Bulk Plant Installations
Designed for use as a primary relief valve on ASME above ground and underground
containers, bulk plant installations and skid tanks. The 3131 Series may also be used as
a primary or secondary relief valve on DOT cylinders, or as a hydrostatic relief valve.
All working components of these relief valves are outside the container connection,
so the valves must be protected from physical damage.
AA3135
3135
3135-10
41 TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pressure Relief Valves & Relief Valve Manifolds
41
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
3127G SS8022G
External Hydrostatic Relief Valves
Designed especially for protection of piping and shut-off valves where there is a possibility
of trapping liquid LP-Gas or anhydrous ammonia. They may be installed in pipelines and
hoses located between shut-off valves or in the side of boss in RegO
shut-off valves.
MFR#
START TO
DISCHARGE
SETTING PSIG
VALVE
BODY
MATERIAL
CONTAINER
CONNECTION
M. NPT
HEIGHT
(APPROX.)
WRENCH
HEX
SECTION
ACCESSORIES
WEBB#
PROTECTIVE
CAP
(INCLUDED)
PIPEAWAY
ADAPTER OR
THREADS
SS8001G
250
Stainless
Steel
1/4
11/16
283973
SS8002G 1/2 189248
SS8021G 1/4
1
11/16 1/4 NPSM Thrds 162494
SS8022G 1/2
187114
SS8021J 1/4
1
11/16 1/4 NPSM Thrds 193305
SS8022J 1/2
7/8
3/8 NPT Thrds 187116
3127K
375
Brass
1/4 131/32
7545-40
162424
3129K 1/2 219/32 11/8 3129-10
3125L
400
1/4
19/16 5/8 3125-40P
162751
3127L 131/32 7/8 7545-40 162426
3129L 1/2 219/32 11/8 3129-40P 3129-10
SS8001L
Stainless
Steel
1/4 7/8 11/16
SS8021L 1/4
13/8
11/16 1/4 NPSM Thrds 162495
SS8022L 1/2
11/16
162490
SS8002U 1/2
SS8021U 1/4
1
11/16 1/4 NPSM Thrds 162496
SS8022U 1/2 3/8 NPT Thrds 189250
42
victormfg.com
Pressure Relief Valves & Relief Valve Manifolds
2
SECTION
Gas Equipment Catalog
DuoPort
.
When equipped with an integral excess fow valve (7550PX), the valve should be mounted
in a forged steel 3000 lb. half coupling. When mounted in a 11/4 X 3/4 NPT reducing
coupling, the 3/4 female thread in this coupling must be full length equivalent to a
forged steel 3000 lb. half coupling.
The excess fow valve will not function properly if these specifcations are not met.
7550P
MFR#
INLET &
OUTLET
CONNECTION
M. NPT
OUTLET
CONNECTION
F. NPT
INTEGRAL
EXCESS
FLOW
FLOW AT
1 PSIG (CV)
PRESSURE
DROP
(GPM/PROPANE)
EXCESS FLOW
APPROXIMATE
CLOSING FLOW
(GPM/PROPANE)
ACCESSORIES
WEBB#
HYDRO-
STATIC
RELIEF
VALVE
VENT
VALVE
7550P
3/4
3/4
No 13.3
3127U 3165 162760
A7550P SS8001J TSS3169 162474
7550PX
Yes 16.0
3127U 3165 162476
A7550PX SS8001J TSS3169 162475
7551P
1/2 No 8.9
3127U 3165 266448
A7551P SS8001J TSS3169 273806
A7706P
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Globe & Angle Valves
47
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Quick-Acting Valves for
Cylinder Charging Hoses
Designed primarily for use on cylinder charging hoses to provide fast, convenient
shut-off and fast opening.
These valves must be installed so that fow through the valve is in the opposite direction
to that of a conventional globe valve. This allows the inlet fow to assist in closing the
valve, even more important, helps prevent the valve from being forced open by high
pump pressure.
7901TA
MFR#
INLET
CONNECTION
F. NPT
OUTLET
CONNECTION
F. NPT
BODY
MATERIAL
FLOW AT
1 PSIG (CV)
PRESSURE DROP
(GPM/PROPANE) WEBB#
A7553A 1/4 1/4 Ductile Iron
1.95
189220
7901TA 3/8 3/8
Brass
162487
7901TB
1/2
1/4 162488
7901TC 1/2 162489
Quick-Acting Valves for Crop Driers and
Charging Manifold Hoses
7554S Series valves provide instant shut-off and fast opening control on LP-Gas crop
driers. They are ideal for charging manifold hoses, stationary fuel transfer hoses and other
applications requiring quick, positive shut-off. They are not for use with delivery truck hoses
because the handle could snag on the ground and open the valve as the hose is needed back
to the truck
7554L Series valves feature a locking handle device to help prevent accidental opening of
the valve. It is ideal for all the same applications as the 7554S Series and may be used on
delivery trucks as it incorporates the locking handle design.
Both valve series must be installed so that fow through the valve is opposite to that of
a conventional globe valve. This allows the inlet fow to assist in closing the valve and
prevents the valve from being opened by high pump pressures.
7554S
MFR#
INLET & OUTLET
CONNECTION
F. NPT
LOCKING
HANDLE
FLOW AT 1 PSIG (CV)
PRESSURE DROP
(GPM/PROPANE) WEBB#
7554SAV
1/2
No
7.3
186921
7554LAV Yes 186920
7554SV
3/4
No
11.5
162555
7554LV Yes 162553
48
victormfg.com
Globe & Angle Valves
2
SECTION
Gas Equipment Catalog
Multipurpose Valves for Liquid Withdrawal
of LP-Gas and NH3 Containers
Designed especially for use as a high capacity liquid withdrawal valve on LP-Gas and
anhydrous ammonia containers.
The A8017DH is equipped with a soft seated automatic differential back pressure check
valve in the seat disc assembly. This allows any pressure build up in the liquid transfer line
in excess of 10-15 psig above the container pressure to fow back into the container. The
transfer hose is protected against excessive liquid or vapor pressure entrapment, which adds
materially to the useful life of fexible hose. In addition to increasing hose service life, the
equalizing valve adds substantially to the operating safety of liquid transfer systems.
Multipurpose Valve for Filling and Liquid
Transfer of NH3 Containers
Designed primarily for use as a combination fller and liquid withdrawal valve on three-
opening applicator tanks or on nurse tanks.
This valve incorporates an integral excess fow valve. When product is required, the valve must be
completely open and backseated to allow the excess fow valve to function properly.
A8017DP
A8018DP
MFR#
INLET
CONNECTION
M. NPT
OUTLET
CONNECTION
F. NPT
EXCESS FLOW
APPROXIMATE
CLOSING FLOW
(GPM/PROPANE)
ACCESSORIES
WEBB#
HYDRO-
STATIC
RELIEF
VALVE
VENT
VALVE
A8017DH
11/4 1
49
Not
Required
TSS3169
187075
A8017DP 55 SS8001J 162493
A8017DLP 190679
MFR#
INLET
CONNECTION
M. NPT
OUTLET
CONNECTION
F. NPT
FILLING
CONNECTION
M. ACME
FILLING
CAPACITY
AT 20 PSIG
PRESSURE
DROP GPM/
NH3
EXCESS FLOW
APPROXIMATE
CLOSING FLOW
(GPM/NH3)
ACCESSORIES
WEBB#
HYDRO-
STATIC
RELIEF
VALVE
VENT
VALVE
A8018DP 11/4 1 13/4 74 50 SS8001J TSS3169 187076
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Ball Valves
49
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
MFR# DESC. WEBB#
JOM100-297 1/8 F X M 111346
JOM100-299 1/4 F X M 111348
JOM100-300 1/4 F X F 151225
For use on LP-Gas, fammable liquids, natural and mfg. gas,
air, N2, inert gases, including helium and CO2.
MFR# DESC. WEBB#
Model T-100 Series
JOM100-701 1/4 F. IPS 184932
JOM100-702 3/8 F. IPS 184933
JOM100-703 1/2 F. IPS 151448
JOM100-704 3/4 F. IPS 151449
JOM100-705 1 F. IPS 163961
JOM100-706 11/4 F. IPS 151450
JOM100-707 11/2 F. IPS 151451
JOM100-708 2 F. IPS 163962
JOM100-709 21/2 F. IPS
JOM100-710 3 F. IPS 151453
Model S-100 Series
JOM100-803 1/2 C X C 151454
JOM100-804 3/4 C X C 151455
JOM100-805 1 C X C 151456
JOM100-806 11/4 C X C 151457
JOM100-807 11/2 C X C 151458
JOM100-808 2 C X C 151459
JOM100-809 21/2 C X C
1/4 2
Operable from -40F to 300F
UL listed
Model T/S-100
MFR# DESC. WEBB#
Model T-204 FIP X FL
JOM101-502 1/2 X 3/8 FIP X FL 165040
JOM101-503 1/2 FIP X FL 58791
Model T-204 FL X FL
JOM101-601 1/2 X 3/8 FL X FL 178937
JOM101-602 3/8 FL X FL 184941
JOM101-603 1/2 FL X FL 184942
JOM101-604 5/8 FL X FL 184940
Model T-204 MIP X FL
JOM101-702 1/2 X 3/8 MIP X FL 164856
JOM101-703 1/2 MIP X FL 164857
MFR# DESC. WEBB#
Model T-204 FIP X FIP
JOM101-401 1/4 FIP X FIP 184937
JOM101-402 3/8 FIP X FIP 184938
JOM101-403 1/2 FIP X FIP 184939
JOM101-404 3/4 FIP X FIP 184935
Models T-204
The new Jomar System-2 FIP to Flare, Flare to Flare and
MIP to Flare valves are new products with vision. Equipped
with all the features of the Blue-Cap
.
Raised wrench fats for installation ease.
It can be used in temperatures from -40F to 300F,
making it ideal for outside use in extremely cold or
warm climates.
The T-handle can be reversed into a locked position, by
turning the handle to the off position, removing the
tamper proof alien screw and reversing the handle
180 into the slot.
Each valve is shipped with plastic thread protectors to
prevent leak causing nicks.
AGA and CGA design certifed for use with natural,
manufactured, mixed, liquifed petroleum and LP gas/
air mixture.
AGA and CGA listed 0.5, 2 lb., 5 lb., System.
Model T-204
Jomars Blue Cap
II may be used as a
150lb. steam valve/600 W.O.G.
MFR# DESC. WEBB#
JOM100-953 1/2 SS 184958
JOM100-954 3/4 SS 184951
JOM100-955 1 SS 184955
JOM100-956 11/4 SS 184956
JOM100-958 2 SS 184957
T-CS-2000 Series
Jomars T-2000 Series of steel valves are designed for rugged
industrial applications of steam, water, oil, gas and corrosive
materials. They are UL approved for LP-Gas, natural and
manufactured gas, LP gas/air mixtures and anhydrous-
ammonia. They feature solid ball construction, reinforced
P.T.F.E. seats, two piece standard port design. Double viton
o-rings prevent stem leakage. Special 2000 psi seats available
upon request.
Locking Device 100-82-3LD Series
Type 2: Fits models T/S100, T-100UE, T/S100ST,
T-100FB, T-100C and T-100SS, Size 3/4.
Type 3: Fits models T/S100, T-100UE, T/S100ST,
T-100FB, T-100C and T-100SS, Sizes 1 and 11/4.
MFR# DESC. WEBB#
JOM210-995 3/4 Locking Device 111377
JOM210-996 1 11/4 Locking Device
Models T-82 Mini Valves
Are designed for steam, water, oil or gas in commercial
and light industrial use. The minivalves are competitive,
conventional port, constructed of heavy duty forged brass,
100% Tefon seats and gland follower with double viton
o-rings, to prevent stem leakage. Sells and installs cost wise
as the leaky plug type, pet cock or gage cock without the
leaks.
Gas Ball Valves
50
victormfg.com
Ball Valves
2
SECTION
Gas Equipment Catalog
Model T-203
Equipped with all the features of the Blue-Cap
,
the System-3 has additional features making it the best
value on the valve market today.
A 1/8 NPT side tap allows a manometer to be inserted
into the valve to test line pressure, eliminating the test
tee and the labor to install it.
It can be used in temperatures down to -40F to 300F,
making it ideal for outside use in extremely cold or
warm climates.
The handle can be reversed into a locked position.
Combined with the tamper proof screw, the possibility
of unauthorized use is sharply reduced.
AGA and CGA design certifed for use with natural,
manufactured, mixed, liquifed petroleum and LP gas/
air mixture.
UL Listings: LP-Gas, fammable liquids, natural and
manufactured gas, air, N2, inert gases including
helium and CO2.
The valve is rated 150 WSP/600 WOG. Remove the plug
and you have a drainable ball valve for any fuid system.
Gas Ball Valves
(continued)
T-2000N Series Carbon Steel
Jomars T-2000N Series of steel valves are designed for
rugged industrial applications of steam, water, oil, gas and
corrosive materials. They are UL approved for LP-Gas,
natural and manufactured gas, LP-Gas air mixtures and
anhydrousammonia. They feature solid ball construction,
2nd generation P.T.F.E. seats, two piece standard port
design. Double Viton O-Rings prevent stem leakage. Special
2000 PSI seats available upon request.
Conforms to federal specifcation WW-V-35.
Latch-Lock Feature: Valve comes complete with latch
lock, which may be locked in open or closed position.
Pressure Rating: 2000 W.O.G.
MFR# DESC. WEBB#
Model T-CS-2000N-SS
JOM100-953 1/2 184958
JOM100-954 3/4 184951
JOM100-955 1 184955
JOM100-956 11/4 184956
JOM100-958 2 184957
Dimension in Inches
SIZE A B C D CV*
1/4 2.07 0.37 1.76 4.33 6.8
3/8 2.07 0.37 1.76 4.33 6.8
1/2 2.34 0.50 1.92 4.33 9.8
3/4 2.80 0.69 2.40 5.83 25
1 3.23 0.87 2.56 5.83 35
11/4 3.57 1.00 2.74 7.76 47
11/2 4.04 1.25 2.98 7.76 81
2 4.63 1.50 3.17 7.76 105
* The CV Factor is the gallons of water per minute passed
through the valve with 1 PSI pressure drop.
MFR# DESC. WEBB#
Model T-203 FIP X FIP
JOM102-301 1/4 FEM Side Tap 178938
JOM102-302 3/8 FEM Side Tap 151303
JOM102-303 1/2 FEM Side Tap 151304
JOM102-304 3/4 FEM Side Tap 151305
JOM170-105 1 FEM Side Tap 178939
Model T-203 FL X FL
JOM102-402 3/8 FL Side Tap 151306
JOM102-403 1/2 FL Side Tap 151307
JOM102-404 5/8 FL Side Tap 151308
JOM102-405 1/2 FEM X FL Side Tap 167285
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Ball Valves
51
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Lockable Valve for Meter
Special design.
Hot forged brass.
Pure Tefon
seats.
-40F +350F temperature.
Approved by AGA & CGA to ASME.
B16.33 & AGA Reqt #3-88.
Full port to DIN 3357 for maximum fow.
Double seal system allows valve to be operated in either
direction making installation easier.
Two Viton 0-rings at the stem for maximum safety.
No maintenance ever required.
600 PSI non-shock cold working pressure.
MFR# DESCRIPTION WEBB#
S80E41 3/4 Lockable Valve 250084
S80F41 1 Lockable Valve 250085
S80G41 11/4 Lockable Valve 378023
S80H41 11/2 Lockable Valve 378025
S80I41 2 Lockable Valve 378026
CODE S80E41 S800F41
D 3/4 1
L 2.519 3.188
H 1.801 1.958
With tamper proof locking cover.
s.80 NPT 3/4 & 1
MFR# SIZE WEBB#
70 Series With Tee-Handle
APO7010307 1/2 54031
APO7010407 3/4 54032
APO7010507 1 54033
APO7010607 11/4 359
APO7010707 11/2 360
APO7010807 2 361
MFR# SIZE WEBB#
80 Series Lever Handle UL Listed for Propane
APO80103 1/2 55189
APO80104 3/4 55190
APO80105 1 55191
APO80106 11/4 55192
APO80107 11/2 55193
APO80108 2 55194
Apollo Valves
Rub Brass Locking Gas Shutoffs
MFR# DESCRIPTION WEBB#
VCTS80E41 3/4 250084
VCTS80F41 1 250085
VCTS80G41 11/4 378023
VCTS80H41 11/2 378025
VCTS80I41 2 378026
8043 Series
MFR# DESCRIPTION WEBB#
VCTS80E43 3/4 With Union 378021
VCTS80F43 1 With Union 378022
VCTS80G43 11/4 With Union 378024
Made In The USA
80 Series
52
victormfg.com
Ball Valves
2
SECTION
Gas Equipment Catalog
Gases: Natural or LP-Gases.
Service Designation: 175 PSIG.
Options: Test Tap at inlet, brass or painted fnish.
100% Leakage Testing: at 1.5 times service designation
(263 PSIG); test methods meet or exceed D.O.T and ANSI
B16.33.
ISO-EN 9002: Certifed.
Threads Conform: To ANSI B1.20.1.
Warranty: 10 years against leakage under normal
operating conditions.
Chicago Faucets
Chicago Faucets multiple service valves enable the user to
access virtually any laboratory gas. Solid brass construction
with a high-gloss polished chrome fnish and color coded
handle index buttons.
Ball valve.
E7 Removable serrated hose nozzle.
Air, gas and vacuum buttons.
3/8 NPT male inlet thread.
124 PSI or approximately 29.9 Hg vacuum.
MFR# DESC. WEBB#
Laboratory Gas Valve
CFC909AGVCP 3/4 NPT Inlet 117590
760B 6276B
560B Black Iron Body
3/4, 1, 11/4, 11/2, 2
560B Black Iron Body
1/2, 3/4, 1, 11/4
MFR# DESC. WEBB#
AYM560B-8 1/2 184925
MFR# DESC. WEBB#
AYM560B-34 3/4 184924
MFR# DESC. WEBB#
AYM6276B-34 3/4 216737
AYM6276B-1 1 216738
AYM6276B-114 11/4 216739
Special Order
High Pressure
Meter Valves
Plug Style
High Pressure
Meter Valves
Ball Style
Tamperproof 175 PSIG
FLAT HEAD LOCKWING
Tamperproof 175 PSIG Patented
FLAT HEAD LOCKWING
Model 175 LWiN
MFR# DESC. WEBB#
Brass Locking Meter Valve With Union
JOM241-004B 3/4 276314
JOM241-005B 1
Pressure Tap Optional
Safe Ball
Valves
Designed with unique 1 NPS threads on both Chek-Lok
are also designed for use on permanent installations provided the excess
fow valve is sized properly for the system and piping. NOTE: In some cases, it may be
necessary to use an in-line excess fow valve to protect the downstream piping. This valve
is not recommended for use as a liquid source for pumps.
Check-Lok
valve.
Eliminates gas fow through Check-Lok
Valves
Design is the original Check-Lok. It has provided the LP-Gas industry with quality and
dependable performance for over 35 years.
These adapters must be used to connect to the 7572FC and 7580FC Check Loks to open
the check mechanism properly. A built in nylon gasket provides a gas tight seal.
7572C-14A 7572C-15A
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
WRENCH HEX
FLATS
WEBB#
7590U-10 1 UNF 3/4 F. NPT 13/4 162762
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
WRENCH HEX
FLATS
WEBB#
7572C-14A
3/4 M. NPT
3/4 F. NPT
1
162761
7572C-15A 3/4 M. NPT 162478
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
A
WRENCH HEX
FLATS
B
APPROXIMATE
LENGTH
WEBB#
7590U-20 15/8 F. UNF 3/4 F. NPT 13/4 41/8 217164
8594-3A Plug 189195
58
victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves
2
SECTION
Gas Equipment Catalog
Double Check Filler Valves for Forklift,
Motor Fuel and RV Tanks
Designed to provide fast flling of forklift, motor fuel, and recreational vehicle tanks.
Double Check Filler Valves
Double-Check Filler Valves for
Large Motor Fuel and ASME Tanks
Designed to provide fast flling of large motor fuel and ASME domestic tanks.
The 6579 Series incorporates a swing-away lower check which greatly reduces pressure drop
across the valve. This lower pressure drop promotes faster flling rates and greater effciency
resulting in more proftable operations.
7647SC
7579
6579
MFR#
(With Lanyard & Cap)
A
HOSE
CONNECTION
B
TANK
CONNECTION
M. NPT
C
WRENCH
FLATS
D
EFFECTIVE
LENGTH
(APPROX.)
PROPANE LIQUID CAPACITY
AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)***
WEBB#
10
PSIG
20
PSIG
30
PSIG
40
PSIG
50
PSIG
7647SA**
13/4 ACME 3/4
11/2 31/16
14 20 24 27 50
190841
7647SC* 13/4 21/4* 162756
* Larger 13/4 hex wrench fats. ** 30 angle on 11/4 ACME hose connection. *** Multiply fow rate by .94 to determine liquid butane capacity.
MFR#
ACME
HOSE
CONNECTION
TANK
CONNECTION
M. NPT
WRENCH
HEX
FLATS
PROPANE LIQUID CAPACITY AT VARIOUS
DIFFERENTIAL PRESSURES (GPM)
WEBB#
CAP
ONLY
CAP,
CHAIN
AND
RING
5
PSIG
10
PSIG
25
PSIG
50
PSIG
75
PSIG
7579 7579C
13/4 11/4 1
50 70 111 157 192 162745
7579P* 37 52 82 116 142 189180
6579** 6579C** 78 110 174 246 301 162467
* Incorporates 3/4 F. NPT dip pipe connection. **Swing-away lower back check valve design for higher flling rate.
NOTE: Multiply fow rate by .94 to determine liquid butane capacity.
MFR# ACME QUANTITY WEBB#
A2797-20R 11/4 25 Pack 187010
A2697-20R 13/4 25 Pack 187009
A3184-8R 21/4 20 Pack 187015
A3194-8R 31/4 10 Pack 162538
RegO
Back Pressure Check Valves are designed to allow flow in one direction only. The
check, normally held in the closed position by a spring, precludes the possibility of flow out
of the container. When flow starts into the container, the pressure overcomes the force of the
spring to open the check. When the flow stops or reverses, the check closes.
60
victormfg.com
Excess Flow, Check, Filler, Vapor Equalizing Valves
2
SECTION
Gas Equipment Catalog
MFR# ACME QUANTITY WEBB#
A2797-20R 11/4 25 Pack 187010
A2697-20R 13/4 25 Pack 187009
Single Check Filler Valves for Storage
with Supplementary Back Check Valves
Designed for use with RegO
Vapor Equalizing Valves consist of an upper back check valve and lower excess flow
valve. In the closed position, the attachment of a vapor hose coupling with its projecting
nozzle, opens the back check valve to permit flow in either direction. The lower excess flow
valve is designed to close automatically when flow out of the container being filled exceeds
the rated capacity. The valve closes automatically when the coupling is removed. Like the
double-check filler valves, the vapor equalizing valves utilize a two-piece body construction.
The lower excess flow valve will permit some leakage when the upper back check valve is
removed for emergency repairs or replacement.
RegO
Vapor Equalizing Valves are designed for use in both ASME and DOT containers.
MFR#
ACME
HOSE
CONNECTION
OUTLET
CONNECTION
M. NPT
WRENCH
HEX
FLATS
PROPANE LIQUID CAPACITY
AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)
FOR USE WITH
BACK CHECK
VALVE
WEBB#
5
PSIG
10
PSIG
25
PSIG
50
PSIG
3174C 13/4 11/4 13/4 23 33 52 74 3176 189144
3194C 31/4 3 31/2 147 208 329 465 A3196 189146
3174C
3170
MFR#
INLET
CONNECTION
OUTLET
CONNECTION
WRENCH
HEX
FLATS
APPROX. CLOSING FLOW AT
100 PSIG INLET PRESSURE
(SCFH/PROPANE VAPOR)
WEBB#
BASIC
WITH
CHAIN
& CAP
3170 11/4 3/4 11/4 7,600 189142
- 3180C 13/4 11/4 13/4 10,000 189145
Flat Gaskets Buna-N
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Excess Flow, Check, Filler, Vapor Equalizing Valves
61
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Bronze Swing Check Valves
Class 300 Y-Pattern Threaded Ends
Features:
Screwed Cap.
Always install with pressure under the disc in vertical or horizontal position.
An arrow cast on the body indicates the correct direction of fow.
MSS-SP-60. Type 3.
Working Pressures Non-Shock:
300 psi Steam, Basic Rating.
1000 psi Cold Working Pressure 1/4 to 2 (6mm 50mm).
600 psi Cold Working Pressure 21/2 to 3 (65mm 80mm).
MFR# WEBB#
CRV76E-38 6143
CRV76E-12 6144
CRV76E-34 6145
CRV76E-1 6146
CRV76E-114 6147
CRV76E-112 6148
CRV76E-2 6149
Swing Check Valve
Bronze Lift Check Valves
Class 300 Threaded Ends
Features:
MSS-SP-80, Type 1.
Suggested to be used on a compressor or similar application with constant pulsating supply.
Must be installed horizontally only.
Working Pressure Non-Shock:
300 psi Steam, Basic Rating.
1000 psi Cold Working Pressure.
Lift Check Valve
MFR# SIZE WEBB#
CRV366E-34 1/4
CRV366E-1 1
CRV366E-114 11/4
CRV366E-112 11/2
CRV366E-2 2 6159
62
victormfg.com
Internal Valves & Accessories
2
SECTION
Gas Equipment Catalog
11/4 Threaded Internal Valve for Small
Capacity Pumping Systems and Bobtail
Vapor Equalization
Designed primarily for use with LP-Gas and anhydrous ammonia as a main valve on small
capacity pumping systems, NH3 nurse tanks and in-line installations. It may also be installed
in the vapor equalizing opening on bobtail delivery trucks. Installation is quick and easy,
and it fts in both full and half couplings, as well as, in-line applications. The valve may be
activated manually by hand or cable.
A7883FK
A3209D050
Flomatic
Filler
Valves used on RegO
.
The unloading adapters can be used to withdraw liquid provided the container is equipped
with a dip pipe extending from the fller valve to the bottom of the container.
Extended Type Hose Couplings for
Vapor and Liquid Service
Designed especially for liquid filling and vapor equalization of LP-Gas and anhydrous
ammonia. The limited travel of the handle on the tailpiece minimizes spin-off, encouraging
cautious removal to properly bleed off trapped product to assure closure of the filler valve
and hose end valve. The ACME threads are machined on a rugged steel insert which is
permanently cast in the aluminum handle, providing for durability under repeated use.
3119A
3120
MFR# STYLE
A
FILLER VALVE CONNECTION
B
HOSE CONNECTION
WEBB#
3119A In-Line
13/4 F. ACME
13/4 F. ACME 162830
3120
Angle 3/4 F. NPT
162831
3121 263104
MFR#
TYPE
OF
SERVICE
HOSE
CONNECTION
M. NPT
COUPLING
CONNECTION
F. ACME
APPROX.
LENGTH
WEBB#
A7575L2*
Liquid
1/2
13/4
7
275141
A7575L3 3/4 162710
A7575L4 1 162711
A7571LB Vapor 3/4 11/4 189221
* Includes 7199-33 adapter, shipped loose.
A7575L
3121
66
victormfg.com
Adapters, Connectors & Fittings
2
SECTION
Gas Equipment Catalog
ACME Adapters
Filler Hose Adapters
These adapters are designed with minimal fow restriction and recommended for use on the
outlet of the LP-Gas delivery truck fller hose. If the controlled bleed off of the connection
indicates the fller valve on the tank being flled has failed to close, the hose adapter should
be left in place on the fller valve and disconnection should be made at the regular fller hose
coupling. (Repair of the fller valve must be made as soon as possible). An integral check
valve in these adapters helps prevent further loss of product. The standard fller valve cap
should be attached to these adapters when left on the container.
3179B
7577V
Gasket (Furnished with adapter)
ACME X Female NPT
Gasket (Furnished with adapter)
ACME X Male NPT
MFR#
BUILT-IN
VENT VALVE
FILLER VALVE
CONNECTION
HOSE
CONNECTION
PROPANE
LIQUID
CAPACITY
AT 80 PSID
WEBB#
7577V Yes
13/4 F. ACME 13/4 M. ACME 57 GPM
162764
3179B No 162763
7576 Yes
MFR# MATERIAL
A
M. ACME
B
F. NPT
C
HEX
D
E
DIAMETER
FOR SPARE
GASKET
ORDER
MFR#
WEBB#
5764A
Brass
13/4
1/4
13/4
11/2
3/4
A2697-
20R
187009
162464
5764B 3/8
1
186865
5764C 1/2 162465
5764D 3/4 186866
5764E 1 162698
5766E
21/4
1
21/4 25/16 1
A3184-
8R
187015
162704
5766F 11/4 186868
5768G
31/4
11/2
31/2 3 2
A3194-
8R
162538
194502
5768H 2 162705
A5764D Steel 13/4 1 13/4 23/16 3/4
A2697-
20R
187009 189210
MFR# MATERIAL
A
M. ACME
B
M. NPT
C
HEX
D
E
DIAMETER
FOR SPARE
GASKET
ORDER
MFR#
WEBB#
5763D
Brass
11/4 3/4 11/4 13/4 7/16
A2797-
20R
187010 189153
5765D
13/4
3/4
13/4
1 11/16
A2697-
20R
187009
186867
5765E 1 2 3/4 162700
5767F
21/4
11/4
21/4 25/16
13/16
A3184-
8R
187015
189154
5767G 11/2 1 189155
5767H 2 2 27/16 125/64 189156
5769H
31/4
2 3 2 1
A3194-
8R
162538
162706
5769K 3 31/2 3 2 189158
A5765C
Steel
13/4
1/2
13/4 23/16
17/32
A2697-
20R
187009
5/16 2
191818
970S 3/16 23/32 162771
970AX
5/16
25/64 404 1.10
187003
970AXS 246565
3199W 27/16 450 0.95 186856
970AW 1
21/16
187002
970HT 3 243117
970JR
1/4
Hose
Barb
5/32 2 190842
MFR# MATERIAL
A
M. ACME
B
M. ACME
C
HEX
D
DIAMETER
FOR SPARE
GASKET
ORDER
MFR#
WEBB#
5765M
Brass
13/4 13/4 21/16
A2697-20R
#187009
162703
5767M 21/4 21/4 25/16 125/64
A3184-8R
#187015
189157
5769M 31/4 1/2 23/4 2
A3194-8R
#162538
162708
ACME Adapters (continued)
MFR# MATERIAL
A
M. ACME
B
F. NPT
C
HEX
D
DIAMETER
WEBB#
A5764W Steel 13/4 11/4 111/16 162699
ACME Plugs
Specifically designed to withstand the everyday abuse given hose end valves on delivery
trucks and hose end couplings on risers in bulk plants. These rugged plugs protect the
coupling tip as well as prevent the entrance of dirt, dust, snow and rain. They also prevent
possible gas contamination from these same sources. The heavily ribbed outer surface
permits hand-tight make-up.
MFR# MATERIAL M. ACME
CHAIN & RING FITS PIPE
SIZE UP TO:
WEBB#
C5762N
Nylon
11/4 3/4 162463
C5765N
13/4
11/4 162466
5765PR Brass 250302
C5767N
Nylon
21/4 11/4 187102
C5769N 31/4 2 162709
POL Plugs
Highly recommended for installation in LP-Gas cylinder valve POL outlets whenever the
service line is disconnected or when the cylinder is being transported. When properly
installed, the POL plug is designed to prevent contamination of the valve outlet and guards
against product leakage if the cylinder valve is accidentally opened.
MFR# MATERIAL CONNECTION WEBB#
N970P Cycolac
M. POL CGA 510
179491
10538P
Brass
189118
3705RC 162456
(CGA 510) POL
970 Hard Nose POL
(CGA 510) POL
970AX Hard Nose POL
With Excess Flow
50-70
Micron
Filter
3199W Heavy Duty Hard Nose
POL With Excess Flow
N970P
68
victormfg.com
Adapters, Connectors & Fittings
2
SECTION
Gas Equipment Catalog
Miscellaneous Adapters
Test Adapters
MFR# MATERIAL A B
C
HEX
D E F WEBB#
1328
Brass
5/8 - 18 UNF 5/8 - 18 UNF
1/2
Hose Barb
13/16 2 11/2 162816
1331 3/4 - 16 UNF 3/4 - 16 UNF 15/16 21/8
13/4
162817
1332 7/8 - 14 UNF 7/8 - 14 UNF 11/16 21/2 162818
MFR# MATERIAL A B WEBB#
15774-1 Brass 1/4 M. NPT
Female Inverted
Flare
162501
POL Adapters
(CGA 510) POL
Male POL X Male NPT
and SAE Flare
(CGA 510) POL
Female POL X Female NPT
and Female POL
(CGA 510) POL
Female POL X Male NPT
2906G Male POL X Female NPT
(CGA 510) POL
MFR# MATERIAL
A
M. ACME
B
C
HEX
D
DIAMETER
WEBB#
2906A
Brass
1/4 1 15/16
1/4
189131
2906G 1/2 2 1 162828
MFR# MATERIAL A B
C
HEX
D
DIAMETER
WEBB#
2906D
Brass
3/8
M. NPT
11/16
15/16 11/32 189132
2906F
3/8
SAE Flare
7/8 9/32
162827
2906E
1/2
SAE Flare
21/4 162826
MFR# MATERIAL A B
C
HEX
D
DIAMETER
WEBB#
5760A
Brass
1/4
15/8 11/8
13/32 162457
5760B 3/8 35/64 162458
5760C 1/2 43/64 162459
5760D 3/4 17/8 13/8
13/32
162460
5760S
POL
CGA 510
21/8 11/8 163431
MFR# MATERIAL A B
C
HEX
D
DIAMETER
WEBB#
5761A
Brass
1/4
15/8 11/8
3/16 186863
5761B 3/8 13/32 186864
5761C 1/2
7/16
162461
5761D 3/4 162462
MFR# MATERIAL A B C WEBB#
1494-1 Brass 12 F. NPT 1/4 F. NPT 1/2 M. NPT 162823
Excess Flow Adapters
MFR# MATERIAL
A
M. NPT
B
HEX
C
DRILL
D
VAPOR AT
100 PSIG
INLET (SCFH)
LIQUID
(GPM)
WEBB#
3188B
Brass
1/2
M. NPT
1 5/16 21/2
700 1.9 246615
3188C 1180 2.9 246616
3188 Heavy Duty Hard Nose POL
With Excess Flow
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Miscellaneous Equipment
69
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
3144-91
Plastic Cap
3175P
Cap Plug
A5776
Reducer Coupling
7141FP
Cap Plug
907FP
3144-90
Metal Cap
1708
POL Cap
3194-90G
ACME Cap With
Stainless Steel Flange
Cap and Reducers
CGA 555 Swivel Adapters
MFR# MATERIAL A
B
Hex
C
Drill
D WEBB#
12982 Brass 1/4 M. NPT 11/4 3/16 115/16 190684
3144-91
Plastic Cap
3175P
Cap Plug
A5776
Reducer Coupling
7141FP
Cap Plug
907FP
3144-90
Metal Cap
1708
POL Cap
3194-90G
ACME Cap With
Stainless Steel Flange
3144-91
Plastic Cap
3175P
Cap Plug
A5776
Reducer Coupling
7141FP
Cap Plug
907FP
3144-90
Metal Cap
1708
POL Cap
3194-90G
ACME Cap With
Stainless Steel Flange
3144-91
Plastic Cap
3175P
Cap Plug
A5776
Reducer Coupling
7141FP
Cap Plug
907FP
3144-90
Metal Cap
1708
POL Cap
3194-90G
ACME Cap With
Stainless Steel Flange
3144-91
Plastic Cap
3175P
Cap Plug
A5776
Reducer Coupling
7141FP
Cap Plug
907FP
3144-90
Metal Cap
1708
POL Cap
3194-90G
ACME Cap With
Stainless Steel Flange
MFR#
CHAIN & RING
FITS PIPE SIZE
UP TO: CAP ONLY MFR# MATERIAL
THREAD
CONNECTION WEBB#
3144-91 3/4" 3144-9P 224434 Cycolac 1 1/4" F Acme
186849
3174-91 3174-9P 162832 1 3/4" F Acme
189143
3174-93 1 1/4"
A8016-9P 275116
162451
1708C 3/4" Nylon F POL CGA510
189128
7141FP 1 1/4" Brass 1 1/4" F Acme
189166
3175P 1 3/4" F Acme
192871
5776 1 3/4" M Acme x 3 1/4" F Acme
261759
3184-90 2" A8016-9P 275116 2 1/4" F Acme
162694
5774 2 1/4" M Acme x 3 1/4" F Acme
3194-90 3" 3 1/4" F Acme
162695
A3184-90 2"
Steel
2 1/4" F Acme
162694
A3194-90 3" 3 1/4" F Acme
162695
A5776 1 3/4" M Acme x 3 1/4" F Acme
187024
70
Miscellaneous Equipment
2
SECTION
Gas Equipment Catalog victormfg.com
1 Rotogages
, the vent valve is opened and the dip tube rotated slowly from
the container vapor space to the liquid space. The difference in appearance of the discharge
indicates when the liquid level is reached. Dial readings then indicate the percentage of
product in the container.
Sight Flow Indicators for Bulk Plants
Designed to promote maximum pump effciency, these indicators enable bulk plant
operators to visually inspect liquid fow conditions. With glass on both sides of the indicator,
fow can be observed from either side, even under some poor light conditions. The integral
swing check also serves as a back-check valve to prevent reverse fow and product loss if the
hose fails in a loading operation.
By installing an indicator on the upstream side of the plant pump, suction conditions can be
observed and the pump speed adjusted to obtain the maximum possible fow rate without
cavitation. Additionally, if an indicator is installed in the piping at the loading rack, just
ahead of the loading hose, the operator can maintain a constant check on pump conditions.
Both installations are designed to allow for observation to provide maximum pump
effciency and assure safe plant pump operation.
In compressor operations a sign fow indicator installed in the liquid line will give a visual
indication when the tank car or transport is emptied. Compressor operation can then be
immediately reversed to start recovery of the vapor.
A7794
MFR# WEBB#
RGOA9091R
RGOA9092R 162597
RGOA9093RS 190686
RGOA9093TS 162598
RGOA9094RS
RGOA9094TS 162600
RGOA9095RS 162602
RGOA9095TS 162678
RGOA9091-M24.0
RGOA9091-M36.0 162679
RGOA9091-M48.0 162680
RGOA9091-M60.0 162681
RGOA9091-M72.0 162988
MFR# SERVICE
CONTAINER
SIZE WEBB#
A9091-18L
LP-Gas
All Sizes 162682
A9091-18LX*
Over 1200
U.S. Gallons
MFR# FOR CONTAINER INSIDE DIAMETER
FOR USE WITH LP-GAS FOR USE WITH NH3 ELLIPSOIDAL HEADS HEMISPHERICAL HEADS
For Mobile
or Stationary
Containers
For Stationary
Containers
Only
For Mobile
or Stationary
Containers
For Stationary
Containers
Only
Side
Mounted
End
Mounted
Side
Mounted
End
Mounted
9091RM24 AA9091RM24 30 - 45 30 - 75 30 - 45 30 - 45
9092RM36 AA9092RM36 46 - 61 76 - 108 46 - 61 46 - 61
9093TSM48* 9093RSM48 AA9093TSM48* AA9093RSM48 62 - 79 109 - 147 62 - 79 62 - 79
9094TSM60* 9094RSM60 AA9094TSM60* AA9094RSM60 80 - 99 80 - 99 80 - 99
9095TSM72* 9095RSM72 AA9095TSM72* AA9095RSM72 100 - 147 100 - 147 100 - 147
MFR# INLET/OUTLET CONNECTIONS LENGTH WEBB#
A7794 2 F. NPT 53/4 162712
A7796 3 F. NPT 7 162713
* Dial permits higher flling level, as per NFPA 58, (1983) Par. 4-5.2.1, Table 4.5.2.1
* Supported design. NOTE: The dip tube must be cut to the required length (1/2 of container inside diameter minus 5-3/4).
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Miscellaneous Equipment
71
2
SECTION
2
V
A
L
V
E
S
&
A
C
C
E
S
S
O
R
I
E
S
Pull-Away Valves for Transfer Operations
Designed especially to provide pull-away protection for LP-Gas and anhydrous ammonia
transfer operations including transport and delivery truck loading and unloading, engine
fuel container flling and miscellaneous cylinder flling operations. When properly fastened
to the inlet end of the discharge hose, the valve is designed to stop gas escape from both
upstream and downstream lines in the event of a pull-away. An excessive tension pull causes
the valve to automatically separate, closing two internal back pressure checks. Only a few
cubic centimeters of gas escape at the instant of separation.
It is recommended that a convenient means be provided to safely remove the pressure from
the line upstream of each coupling half to enable reassembly of the valve. To reassemble,
simply push the male half frmly into the female half until the retaining balls slip into the
retaining groove. Check for leaks after reassembly.
NOTE: It is recommended that pull-away valves be safety-tested at least monthly to confrm that they
will separate properly in the event of a pull-away. Dry nitrogen or other inert gas is suggested for a
source of pressure during such tests.
Swing-Check ESVs for Bulk Plants
Especially designed for installation in liquid transfer lines at LP-Gas or anhydrous ammonia
bulk plants to provide for quick shut-off of liquid or vapor fow in the event of an accidental
pull-away or hose rupture, both of which can cause a fre.
A2141A6L
6016 2 ESV
MFR#
INLET/OUTLET
CONNECTIONS
NPT F.
DISCONNECT
FORCE
APPROX-LBS
RECONNECT
FORCE
APPROX-LBS
LENGTH
OF
VALVE
LP-GAS LIQUID FLOW CAPACITY
AT VARIOUS DIFFERENTIAL
PRESSURES (GPM)*
WEBB# 5 PSIG 10 PSIG 25 PSIG 50 PSIG
A2141A6
3/4 130 80 37/8 11 16 25 36
162683
A2141A6L** 162684
A2141A8 1 75 50 49/16 21 30 47 67 187008
A2141A10 11/4 160 25 55/8 52 75 120 170 189203
A2141A16 2 300 50 145/16 250 350 550 750 187007
MFR#
FOR USE
ONLY WITH
INLET/OUTLET
CONNECTIONS
LIQUID LOW CAPACITY AT
10 PSIG PRESSURE DROP (GPM) WEBB#
6024 LP 3 F. NPT 427 (NH
3
) 394985
6016 LP 2 F. NPT 427 (NH
3
) 308754
6010 LP 1 F. NPT 427 (NH
3
) 370270
* To determine NH
2
liquid fow capacity, multiply by .90.
** Lanyard.
MFR# DESCRIPTION WEBB#
6016-60C Pneumatic Open/Close Actuator 361807
6016-60D Pneumatic Release for Point of Transfer 359336
72
Miscellaneous Equipment
2
SECTION
Gas Equipment Catalog victormfg.com
Hose End Adapters for DOT Cylinder Filling
Designed to provide quick and easy flling of DOT cylinders with POL or Type 1 connections.
This adapter may be used with hydraulic and electric automatic systems or with manual
systems in conjunction with a RegO
T
a
l
l
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
C
Y
L
I
N
D
E
R
S
,
T
A
N
K
S
&
A
C
C
E
S
S
O
R
I
E
S
Cylinders, Tanks & Accessories
97
4
4
SECTION
Cylinder Hand Trucks
MFR# DESCRIPTION WEBB#
HPR70416 For LP Cylinders 182214
VCTNMP79004P For 420 lbs. Cylinders 190693
Cylinder Hand Truck
Appliance Truck
MFR# WEBB#
HPREA6061 182215
Appliance Truck
Methanol Injector
MFR # DESCRIPTION WEBB#
VCTTMI-1QL Methanol Injector 215392
TMI-1QL Methanol Injector
MFR# DESCRIPTION WEBB#
RIMABJ2 Methanol Injector Hand Held Pump Style 186594
Hand Held Pump Style
POL Valve Wrench Kit
MFR# DESCRIPTION WEBB#
VCT201 Polished POL Plugs 184417
VCT202 Valve Wrench 184418
VCT203 Handle 20-3 184419
Handle
Wrench
POL Adapter
OPD Cylinder Vise
Wrench Kit
The Best Way to Install OPD Cylinder Valves
The TTW-3 is a totally new concept in valve wrenches. It
quickens installation and removal of QC cylinder valves
from DOT containers. The wrench works on all Style 1
(QC) valves, particularly the fxed handwheel OPDs that are
mandated by the DOT for all 5 lbs. to 40 lbs. cylinders.
The TTW-3 mates to the cylinder valve QC thread, rather
than the POL thread, reducing the possibility of valve
deformation when removing or installing. The wrench
seats fush against the valve face, distributing torque across
a wider area. And the compact TTW-3 fts under the
handwheel valve and allows rotation inside the cylinder
collar, simplifying the removal and installation procedure.
The TTW-3 also incorporates a bleed orifce safety feature
that will indicate any pressure remaining in the cylinder
before removing the valve by simply opening the valve
slightly prior to loosening. The wrench is made from tough,
durable alloy and forged steel components. This long-lasting
construction resists corrosion and distortion.
MFR# WEBB#
VCTTTW-3 192938
98
victormfg.com
Cylinders, Tanks & Accessories
4
Gas Equipment Catalog
SECTION
500 gal. of water X 8.345 (pounds per gallon) = 4172.5 lbs. of
water tank weight (940#) = 3232.5 pounds of buoyancy to
overcome.
Pad length and width must be converted to feet in the chart
below to have the calculator formulas to work correctly. Good
engineering practice would be to make the pad at least 1 ft.
(6 inches on each side) bigger than the container so the
stainless anchors only have a direct vertical pull when attached
to the stainless coated cable. 3/8 coated cable should provide
enough tensile strength to overcome the bouyancy factor.
FACTORS LBS
1 CU Yard of Concrete 4000
CU ft. of Concrete 148
CU ft. of Water 62.4
1 Gal. of Water 8.345
1 CU Yard of Sand 2400
1 CU Yard of Dirt (Clean Humus or Fill) 3800
Conversion Factors
QUALITY STEEL
TANK SIZE
PAD
LENGTH
(MIN)
PAD
WIDTH
(MIN)
WEIGHT
OF
TANK
TANK H20
CAPACITY
BUOYANCY
FACTOR
NEEDED
TO KEEP IN
GROUND 4 PAD 6 PAD 9 PAD 12 PAD
120 U/G (5 8 L X 24 OD) 5.583 3 260 120 741.4 818.0212 1239.426 1859.139 2478.852
250 U/G (7 8 L X 30 OD) 7.666 3.5 480 250 1606.25 1310.426 1985.494 2978.241 3970.988
320 U/G (9 6 L X 30 OD) 9.5 3.5 620 320 2050.4 1623.93 2460.5 3690.75 4921
500 U/G (10 0 L X 37 OD) 10 4.08 940 500 3232.5 1992.672 3019.2 4528.8 6038.4
1000 U/G (15 10 L X 41 OD) 15.833 4.417 1800 1000 6545 3415.594 5175.143 7762.714 10350.29
This calculator is for general reference only. When in doubt have an engineer design a system to your individual job specifcation
and local code requirements.
Tank Buoyancy Chart for Concrete Pad Size
Magnesium Anodes
Magnesium anodes have a 10 length
of #12 electric wire attached.
MFR# DESCRIPTION WEBB#
Anode 17 #17 183403
Anode 5 #5 215998
Typical Small ASME Container Underground Installation
Iron Pipe
Anode Requirements
PIPE
PIPE SIZE LENGTH
Install 0ne 5 lbs. Anode
3/4 500
11/4 450
11/2 425
2 400
Install 0ne 17 lbs. Anode
3 700
14 500
6 400
8 350
Typical Tank
Anode Requirements
17 LBS.
ANODES
TANK SIZE REQUIRED
500 gals. 1
1,000 gals. 2
3,000 gals. 4
400 to 5,000 gals. 6
10,000 gals. 8
15,000 gals. 10
20,000 gals. 12
25,000 to 30,000 gals. 14
Pipe Wrap
MFR# DESCRIPTION WEBB#
KMC4130 Yellow Pipe Wrap, 2 X 100 243386
PAS9052R Black Pipe Wrap, 2 X 100 81161
MISUD21 Underground Gas Detector Tape 183516
VCTTRACER Tracer Wire 500 14GA 359306
ELE1207PE30-4E Tracer Wire 500 12GA 243218
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
C
Y
L
I
N
D
E
R
S
,
T
A
N
K
S
&
A
C
C
E
S
S
O
R
I
E
S
Cylinders, Tanks & Accessories
99
4
4
SECTION
Propane Storage Vessels
The withdrawal of propane vapor from a vessel lowers
the contained pressure. This causes the liquid to boil
in an effort to restore the pressure by generating vapor to
replace that which was withdrawn. The required latent
heat of vaporization is surrendered by the liquid and
causes the temperature of the liquid to drop as a result of
the heat so expended.
The heat lost due to the vaporization of the liquid is
replaced by the heat in the air surrounding the container.
This heat is transferred from the air through the metal
surface of the vessel into the liquid. The area of the vessel
in contact with vapor is not considered because the heat
absorbed by the vapor is negligible. The surface area of
the vessel that is bathed in liquid is known as the wetted
surface. The greater this wetted surface, or in other
words the greater the amount of liquid in the vessel, the
greater the vaporization capacity of the system. A larger
container would have a larger wetted surface area and
therefore would have greater vaporization capacity. If the
liquid in the vessel receives heat for vaporization from the
outside air, the higher the outside air temperature, the
higher the vaporization rate of the system. How all this
affects the vaporization rate of a 100 lbs. cylinder is shown
in a following section (return to contents and see 100#
DOT cylinders. You will note that the worst conditions
for vaporization rates are when the container has a small
amount of liquid in it and the outside air temperature is low.
Simple formulae for determining the proper number of
DOT cylinders and proper size of ASME storage containers
for various loads where temperatures may reach 0F will be
found in the sections on 100# DOT Cylinders and ASME
Storage tanks respectively
Determining Total Load
In order to properly size the storage container, regulator
and piping, the total BTU load must be determined.
The total load is the sum of all gas usage in the installation.
It is arrived at by adding up the BTU input of all appliances
in the installation. The BTU input may be obtained
from the nameplate on the appliance or from the
manufacturers literature.
Future appliances which may be installed should also
be considered when planning the initial installation to
eliminate the need for a later revision of the piping and
storage facilities.
Where it may be more desirable to have ratings expressed in
CFH, divide the total BTU load by 2516 for CFH of propane.
Approximate BTU Input for
Some Common Appliances
APPLIANCE APPROX INPUT
(BTU PER HOUR)
Range, Free Standing, Domestic 65,000
Built-in Oven or Broiler, Domestic 25,000
Built-in Top Unit, Domestic 40,000
Water Heater, Quick Recovery, Automatic Storage
30 Gallon Tank 30,000
40 Gallon Tank 38,000
50 Gallon tank 50,000
Water Heater, Automatic Instantaneous
2 gal./min. 142,800
4 gal./min. 285,000
6 gal./min. 482,000
Refrigerator 3,000
Clothes Dryer, Domestic 20,000
Incinerator, Domestic 32,000
100# DOT Cylinders
Rule of Thumb Guide
for Installing 100 lb. Cylinders
For continuous draws where temperatures may reach zero
F. Assume the vaporization rate of a 100 lb. cylinder as
approximately 50,000 BTU per hour.
Number of Cylinders per side = Total load in BTUs
50,000
Example:
Assume total load = 200,000 BTU/hr.
Cylinders per side = 200,000 = 4 cylinders per side.
50,000
This chart shows the vaporization rate of containers in terms
of the temperature of the liquid and the wet surface area
of the container. When the temperature is lower or if the
container has less liquid in it, the vaporization rate of the
container is a lower value.
Vaporization Rate 100 lbs. Propane Cylinders
(approximate)
LBS. OF
PROPANE
IN CYL.
MAXIMUM CONTINUOUS DRAW IN
BTU PER HOUR AT VARIOUS
TEMPERATURES IN DEGREES F.
0 20 40 60 70
100 113,000 167,000 214,000 277,000 300,000
90 104,000 152,000 200,000 247,000 277,000
80 94,000 137,000 180,000 214,000 236,000
70 83,000 122,000 160,000 199,000 214,000
60 75,000 109,000 140,000 176,000 192,000
50 64,000 94,000 125,000 154,000 167,000
40 55,000 79,000 105,000 131,000 141,000
30 45,000 66,000 85,000 107,000 118,000
20 36,000 51,000 68,000 83,000 92,000
10 28,000 38,000 49,000 60,000 66,000
100
victormfg.com
Cylinders, Tanks & Accessories
4
Gas Equipment Catalog
SECTION
ASME Storage Containers
Determining Propane Vaporization Capacity
Rule of Thumb Guide for ASME LP-Gas Storage Containers
Where
D = Outside diameter in inches
L = Overall length in inches
K = Constant for percent of volume of liquid in container
L
D
* These formulae allow for the temperature of the liquid to refrigerate to -20F
(below zero), producing a temperature differential of 20F for the transfer of heat
from the air to the containers wetted surface and then into the liquid. The vapor
space area of the vessel is not considered. Its effect is negligible.
Vaporizing Capacities for
Other Air Temperatures
Multiply the results obtained with the above formulae by one of the following factors for the
prevailing temperature.
PERCENTAGE OF
CONTAINER FILLED
K
EQUALS
PROPANE VAPORIZATION
CAPACITY AT 0
0
F (IN BTU.HR.)*
60 100 D X L X 100
50 90 D X L X 90
40 80 D X L X 80
30 70 D X L X 70
20 60 D X L X 60
10 45 D X L X 45
PREVAILING AIR
TEMPERATURE
(IN DEGREES F) MULTIPLIER
PREVAILING AIR
TEMPERATURE
(IN DEGREES F) MULTIPLIER
-15 0.25 +5 1.25
-10 0.50 +10 1.50
-5 0.75 +15 1.75
0 1.00 +20 2.00
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
C
Y
L
I
N
D
E
R
S
,
T
A
N
K
S
&
A
C
C
E
S
S
O
R
I
E
S
Cylinders, Tanks & Accessories
101
4
4
SECTION
Quality Steel Replacement Parts
QS PART # DESCRIPTION MFR # WEBB # ALT. MFR # ALT. WEBB #
Tank Size 120
01-001 Filler Valve 7579-T 162745
01-009-1 Float Gauge B8981-1186 HA-130AQ 315792
01-021 Multi Valve, Tube length 6.7 7556-RS 162742
01-007 Relief Valve 7583-GT 162747
01-031 U/G Float Gauge JB-302 315650
Tank Size 150
01-001 Filler Valve 7579-T 162745
01-009-1 Float Gauge B8981-1186 HA-130AQ 315792
01-021 Multi Valve, Tube length 6.7 7556-RS 162742
01-007 Relief Valve 7583-GT 162747
01-008-1 Check Lok 7590-UT 162748
01-031 U/G Float Gauge JB-302 315650
Tank Size 250
01-001 Filler Valve 7579-T 162745
01-010-1 Float Gauge HA 156-AQ 315681
01-023 Multi Valve, Tube length 8.5 7556-RS 162742
01-007 Relief Valve 7583-GT 162747
01-008-1 Check Lok 7590-UT 162748
01-017 U/G Float Gauge, L.N.R. JB350B 315667 JB332BRN 315807
01-045 U/G Float Gauge, S.N.R. JB224B
Tank Size 320
01-001 Filler Valve 7579-T 162745
01-010-1 Float Gauge HA 156-AQ 315679
01-023 Multi Valve, Tube length 8.5 7556-RS 162742
01-007 Relief Valve 7583-GT 162749
01-008-1 Check Lok 7590-UT 162748
01-017 U/G Float Gauge, L.N.R. JB350B 315661 JB332BRN 315807
01-045 U/G Float Gauge, S.N.R. JB224B
Tank Size 475
01-001 Filler Valve 7579-T 162745
01-011-1 Float Gauge HA 194-AQRN 315679
01-002 Multi Valve, Tube length 10.5 7556-RS 162742
01-012 Relief Valve 8684-GT 162749
01-008-1 Check Lok 7590-UT 162748
01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 315806
01-046 U/G Float Gauge, S.N.R. JB260C
Tank Size 500
01-001 Filler Valve 7579-T 162745
01-011-1 Float Gauge HA 194-AQ 315679
01-002 Multi Valve, Tube length 10.5 7556-RS 162742
01-012 Relief Valve 8684-GT 162749
01-008-1 Check Lok 7590-UT 162748
01-018 U/G Float Gauge, L.N.R. JB384B 315661 JB370FP-J09 315806
01-046 U/G Float Gauge, S.N.R. JB260C
Tank Size 1000
01-001 Filler Valve 7579-T 162745
01-016-1 Float Gauge HA 210-AQ 315793 HA210ARN 315677
01-025 Multi Valve, Tube length 11.3 7556-RS 162742
01-013 Relief Valve 8685-GT 162750
01-008-1 Check Lok 7590-UT 162748
01-019 U/G Float Gauge, L.N.R. JB404B 315657 JB386ERN 315805
01-047 U/G Float Gauge, S.N.R. JB280C
102
victormfg.com
Paint & Supplies
5
SECTION
Gas Equipment Catalog
Premium Industrial Coatings
Primers
A single package epoxy primer of high quality that offers excellent corrosion resistance
and fast re-coat time. This product is user friendly and offers great coverage.
MFR# DESCRIPTION WEBB#
SUM855G1368 Gray-Green Primer 184237
SUM899W1370 Off White Primer 184238
MFR# DESCRIPTION WEBB#
SUM880N2209 Foot Ring Protector, Black 184248
MFR# DESCRIPTION WEBB#
SUM880W2203 No. 5 Blued White Tank Enamel 184244
SUM880W2201 No. 7 Silicone Alkyd White 184249
MFR# DESCRIPTION WEBB#
SUM880S2205 SC1000 Tank Coating, Aluminum 184233
SUM880S2206 SC1110 Strontium Chromate, Aluminum 184234
SUM880S2207 Aluminum Enamel Paint 184235
MFR# DESCRIPTION WEBB#
SUM880G0166 Green Enamel 184182
SUM880L0184 Tan Enamel 184239
SUM885N2100 Black Enamel 184240
SUM880D0130 Mist Gray 184236
SUM885R2108 Red 184241
SUM886Y8625 Industrial Yellow 184245
Primers
Foot Ring Protector
White Paint
Aluminum Paint
Enviro-Tuff Industrial Enamels
MFR# DESCRIPTION WEBB#
SUM856X2210 XL Thinner 184251
Foot Ring Protector
A protective coating that is modifed with phenolic resins making this a great product for
the bottoms of cylinders. When applied properly, this product aids in corrosion resistance.
Can be mopped, brushed or sprayed.
White Paint
Blued White Tank enamel was formulated especially for Propane Tanks offering
elasticity, excellent weathering, one coat coverage, and user friendly. Works great with
rollers, brushing and also can be sprayed. Silicone Alkyd White is the premium of our
Tank Enamels, modifed with high percentage of silicone offering excellent gloss and
color retention. This product is highly recommended for painting storage tanks when
maximized coating life is a must.
Aluminum Paint
Tank Coating is our most popular aluminum fnish that has nearly 2 pounds of aluminum
paste in every gallon. SC1000 was formulated using premium blend of oleoresinous
varnishes. Strontium Chromate is the premium in our aluminum fnishes, all the same great
qualities of our SC1000 plus the addition of built in rust inhibitor.
Enviro-Tuff Industrial Enamels
A high quality industrial enamel offered in an assortment of colors to personalize your
tanks. This product is great for many other exterior uses.
Paint Thinner
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
P
A
I
N
T
&
S
U
P
P
L
I
E
S
Paint & Supplies
103
5
SECTION
5
Paint Accessories
MFR# DESCRIPTION WEBB#
SUMSC-TTB002 12 Trim Brush 184250
SUMKM-1009 5 Gal. Bucket 192127
SUMSC-BC003 Bucket Cover (3 Per Pkg.) 192913
SUMSC-BG-001 Bucket Grid 242094
SUMSCL9V14 9 Lambswool Roller Cover 184195
SUMSC-CR006 Contour Roller Cover 184192
SUMSC-TR09K 9 Roller Handle 184247
SUMSC-EP03P 42 Extension 3 pc. 242095
SUMSC-WB042 Pole Wire Brush
SUMSC-CR063 Contour Roller Complete 264998
12 Trim Brush 5 Gallon Bucket
Bucket Grid
Bucket Cover
Lambswool Roller Cover
Roller Handle
Contour Roller
Complete
Wire Brush
42 Extension
Coverage Data: Enamels and Primers
Premium Industrial Coatings (continued)
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
Coverage Data: Aluminums and Primers
The above data is theoretical and may vary slightly from batch to batch and also in dependent on amount of paint actually applied.
TANK SIZE
(GALLONS)
APPROX
SQ. FEET
NO. 5
BLUED WHITE
NO. 7 SILLICONE
ALKYD WHITE
100D8431
HI SOLIDS
UNI-POX PRIMER
1370 OFF WHITE
UNI-POX PRIMER
1368 GRAY GREEN
30,000 1,950 7 Gallons 7 Gallons 7 Gallons 7 Gallons 7 Gallons
18,000 1,250 5 Gallons 5 Gallons 5 Gallons 5 Gallons 5 Gallons
12,000 1,150 4 Gallons 4 Gallons 4 Gallons 4 Gallons 4 Gallons
1,000 225 1 Gallons 1 Gallons 1 Gallons 1 Gallons 1 Gallons
500 115 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon 2 Tanks Per Gallon
250 55 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon 4 Tanks Per Gallon
Sq. Ft.
Coverage per
Gal. at 1 dry mil
740 760 810 785 785
Recommended
dft. per coat
Brand Refective
V = Vinyl
P = Polyethylene (plastic)
A = 6 letters
B = 4 letters
BB = 3 letters
C = 2 letters
D = 1 letters
V72
V288-BB
V58
CYLINDER FILLING
CAPACITY CHART
W.C. LBS. PROPANE
2.39
4.78
7.17
9.56
11.9
14.3
16.7
19.1
21.5
23.9
26.2
28.6
31.0
33.4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
W.C. LBS. PROPANE
35.8
38.2
40.6
43.0
45.4
47.8
59.7
71.7
78.8
83.6
95.6
105.1
119.5
239
1
2
3
4
5
6
7
8
9
10
11
12
13
14
P101
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
PROPANE GAS 2 P.S.I.
V47
V62
Updated Test & Retest Kits
MFR# DESCRIPTION SIZE WEBB#
V31 Periodic Inspection Chart 6 X 18
V32 5 Year Inspection Kit 6 X 18 359351
V31
No Smoking Sign
MFR# DESCRIPTION SIZE WEBB#
V49 No Smoking Vinyl (Stick-On Decal) 10 X 42 188815
V49
V32
Placard Holder
MFR# DESCRIPTION WEBB#
MPH69 .050 Aluminum With Baked Enamel Finish 181423
& Stainless Steel Clip
MPH69
D.O.T. Placarding for Bulk Transporters
MFR# DESCRIPTION WEBB#
V1075 Vinyl 181435
P1075 Polyethylene 181426
G1075 Magnetic Blanket 181418
V1075
P1075
G1075
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
P
A
I
N
T
&
S
U
P
P
L
I
E
S
Signs/Decals
105
5
SECTION
5
Signs and Decals (continued)
Storage Tank Diamond for Propane
Red, Yellow, Blue & Black on White Vinyl
MFR# DESCRIPTION SIZE WEBB#
V704-3 300 Legibility 15 X 15 308184
V704-1 100 Legibility 7.5 X 7.5 269724
V704-3
V704-1
Danger Sign
MFR# DESCRIPTION SIZE WEBB#
SP53-R Black On Yellow Vinyl 4 X 9 181434
Filling Procedure Decals
MFR# DESCRIPTION SIZE WEBB#
V121 Vinyl 11 X 12 192753
P121 Polyethylene 11 X 12 269726
V122 Vinyl 11 X 12 309161
P122 Polyethylene 11 X 12 269725
V79 Black on Yellow Vinyl 2 X 31/2
V121/P121 V122/P122
V79
OPD Signs
MFR# DESCRIPTION SIZE WEBB#
P114 Retroft Chart (Blue On White Poly) 18 X 24 359348
P111 Alert Sign (4 Holes & 2 Colors) 16 X 20 251721
P114
P111
Liquid/Vapor Signs
MFR# DESCRIPTION SIZE WEBB#
V90 Red On White Vinyl 1 X 4
V90-5 Red On White Vinyl (5 per Sheet) 1 X 4 309284
V91-5 Red On White Vinyl (5 per Sheet) 1 X 4 269723
V90
V90-5 V91-5
Emergency Signs
MFR# DESCRIPTION SIZE WEBB#
V81 Pull Red On White Vinyl 10 X 12
P81 Pull Red On White Polyethylene 10 X 12 359350
V82 Push Red On White Vinyl 10 X 12
P82 Push Red On White Polyethylene 10 X 12 192752
11-V-127 Red On White Vinyl 12 X 30
11-P-127 Red On White Polyethylene 12 X 30
V81/ P81
11-V-127
11-P-127
V82/ P82
106
victormfg.com
Signs/Decals
5
SECTION
Gas Equipment Catalog
Portable Cylinder Labels
MFR# DESCRIPTION SIZE WEBB#
A16 Curved, Black Imprint 181416
AA16 Not Curved 181417
A53 Black on White Vinyl 1.5 X 5 223683
A16 (Curved)
AA16
A53
Signs and Decals (continued)
MFR# DESCRIPTION SIZE WEBB#
HZ116 Blue, Yellow, Red & Black 21/2 X 5 181419
Hazard Sign
Propane Filling Station Signs
MFR# DESCRIPTION SIZE WEBB#
M97A Single Faced (Blue On White Aluminum) 2 X 4 181421
M97-AX Exchange (Blue On White Aluminum) 2 X 4
M97-AD Double Faced (Blue On White Aluminum) 2 X 4 181413
M97-AXD Exchange (Blue On White Aluminum) 2 X 4
V14 Red & Black On White Vinyl 12 X 16 309160
C37 Red & Black On Coroplast 12 X 24
M97-FR Frame for 2 X 4 Signs With Hardware 181444
MFR# DESCRIPTION WEBB#
B/S42001 Portable Label Pusher 193975
MFR# DESCRIPTION WEBB#
MISSIGNDV Direct Vent Appliance Below 309803
M97A, M97AD M97AX, M97AXD
V14
C37
No Smoking While Refueling Decals
MFR# DESCRIPTION SIZE WEBB#
V266 Red On White Vinyl 24 X 36
V26-A Red On White Vinyl 12 X 18 309159
V26-B Red On White Vinyl 12 X 18
M26-C Baked Enamel On Aluminum 24 X 36 181441
Label Maker
VersaPrinter
Quickly create any
type of label or sign
and print as many as
you need in a matter
of minutes. . . right
from your own
computer!
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
107
6
SECTION
6
Gauges
The One Gauge
Adjustable
Liquid-Level Gauge
49S
Application
The One Gauge is a magnetically-coupled liquid-level gauge that adjusts in length and
accepts a variety of foat stem lengths. This feature makes it easy to quickly and economi-
cally replace non-functional gauges in the feld for a large variety of tank sizes. They are
UL listed.
General Information & Features
This gauge features a range of adjustable stems which, when mated with an appropriate-
length foat assembly, enables LP Gas dealers to easily replace the liquid-level gauge in
virtually all LP Gas tanks used for domestic storage or mobile applications. Models are
available with Junior bolted heads in aluminum or brass, Senior bolted heads in
aluminum, and a version with a Junior 11/4 or 1 male NPTF brass head.
The design utilizes a square-brass centershaft telescoping inside a square-aluminum
pinionshaft, both of which are housed in telescoping aluminum support tubes. An
aluminum locknut compresses an aluminum locking sleeve to secure the tubes at the
required stem length. All other components are of the same materials as standard
Rochester LP Gas gauges.
The proper foat assembly is attached to the gear housing on the adjustable stem per
instructions shown below.
Materials of Construction
Head
Aluminum or Brass
Drive Magnet
Alnico
Centershaft
Brass
Pinionshaft & Support Tubes
Aluminum
Gears, Cross Stud, & Bearings
Stainless Steel
Gear Housing
Zinc
Approvals
Gauges are UL listed for
LP Gas Service Applications
When ordering, specify:
1. Gauge head size ( Jr., Sr., 11/4 NPTF, or 1 NPTF).
2. Aluminum or brass.
3. Tank diameter, shown on nameplate.
4. Mounting location (top, side, end, or angle).
5. If the gauge is angle mounted, state the degree of angle above or below the horizontal
centerline, or the distance in inches above or below the horizontal centerline to the
center of the gauge opening.
6. If the gauge is end mounted, state the shape of the tank head
(hemispherical or semi-ellisoidal).
7. Specify the H dimension. This is the distance in inches from the surface of the tank
to the top of the mounting surface.
108
victormfg.com
Gauges
6
SECTION
Gas Equipment Catalog
Gauges
MFR# DESCRIPTION WEBB#
0049S02159BP Jr. 121/2 to 193/4 Brass Head 359139
0049S02170BP Jr. 191/2 to 331/4 Brass Head 361810
Adjustable LP Gas Gauges
Jr. Adjustable GaugesLess Float
Sr. Adjustable GaugesLess Float
1 Adjustable GaugesLess Float
11/4 Adjustable GaugesLess Float
Float Assemblies
Adjustable Kits
MFR# DESCRIPTION WEBB#
0049S02207P Sr. 121/2 to 193/4 Alum. Head 359136
0049S02208P Sr. 191/2 to 331/4 Alum. Head
MFR# DESCRIPTION WEBB#
0049S02160BP 1 - 121/2 to 193/4 Brass Head 359137
0049S02167BP 1 - 191/2 to 331/4 Brass Head 362437
MFR# DESCRIPTION WEBB#
0049S02203BP 11/4 - 121/2 to 193/4 Brass Head 359138
0049S02204BP 11/4 - 191/2 to 331/4 Brass Head 362436
MFR# DESCRIPTION WEBB#
6857S11009UP Float 24 Tank ID 359135
6857S13759UP Float 30 Tank ID 359134
6857S14379UP Float 32 Tank ID 359133
6857S17009UP Float 37.5 Tank ID 359132
6857S18509UP Float 41 Tank ID 361809
MFR# DESCRIPTION WEBB#
6287-00001K Jr. Support With 4 Floats 359140
DIAL WEBB#
5909S02733 184077
5909S02733 184077
DIAL WEBB#
5986S02733 184073
5986S02733 184073
DIAL WEBB#
5909S02733 184077
5909S02733 184077
DIAL WEBB#
5909S02733 184077
5909S02733 184077
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
109
6
SECTION
6
Gauges
6200
Application
Junior gauges are supplied standard with 0015-00007 Buna-N gasket and four 0040-00414
zinc-plated steel mounting screws (1/4 28 X 7/8) for attachment to a gauge adapter
with 2.03 [51,5] diameter bolt circle (see Rochester Machining Standard MS-501).
Models 6281 and 6284 Junior gauges used on above ground ASME storage tanks are
equipped with direct reading 5323S01749 percentage dials. Model 6281 Junior gauges
used on below ground ASME storage tanks are equipped with direct-reading 5323S01813
percentage dials. Models 6241 and 6244 Junior gauges used on ASME motor fuel tanks are
equipped with direct-reading 5323S01789 fractional dials.
General Specifcations
Temperature Range
Standard range is -40F to 158F, -40C to 70C.
Accuracy
Dependent on proper sizing of gauge and tank confguration. When equipped with Jr.
dial, overall accuracy is 5%, Sr. dial is 3%, TwinSite sender is 5%, 4 dial is 3%.
Humidity
For high humidity below ground or under chassis applications, brass, stainless steel, or
painted aluminum heads are recommended.
Shock & Vibration
Suitable for mobile service applications.
Current
200 mA maximum on TwinSite versions.
System Voltage
12 to 24 volts on TwinSite versions.
Working Pressure
375 psi. [25,8 Bar]
Approvals
Gauges are UL listed for LP Gas service applications.
When ordering, specify:
1. Gauge head size, Jr., Sr., or model #.
2. Tank diameter as shown on nameplate.
3. Mounting location (top, side, end or angle).
4. If gauge is angle mounted, state angle.
5. If gauge is end mounted, state the shape of the tank head, hemispherical or
semi-ellipsoidal.
6. The H dimension, the distance in inches from the surface of the tank to the top of
the gauge opening.
To order replacement gauge, simply furnish the information stamped on one of the fat
sections on the side of the gauge head as shown in the example.
Model number = 6244
Support length = 71/2
Tank Diameter = 14
Mfg date = B75
NOTE: Gauge head may
also be stamped with model
& unique suffx #.
6244 - 71/2- 14 B75
110
victormfg.com
Gauges
6
SECTION
Gas Equipment Catalog
Gauges
6300 Series
Application
The 6300 Series Magnetel liquid-level gauges are designed to accurately determine the
percentage of total tank volume for most liquids in stationary-storage applications. UL listed
for LP Gas and NH3 service.
General Information & Features
These Magnetel Gauges are available in four basic models:
Model 6336 Incorporates 4 [100 mm] dial and is designed for top mounting.
Model 6360 Incorporates 8 [200 mm] dial and is designed for top mounting.
Model 6339 Incorporates 4 [100 mm] dial and is designed for side, end or
angle mounting.
Model 6342 Incorporates an 8 [200 mm] dial and is designed for side, end or
angle mounting.
The large, easy-to-read dials are also easy to remove and replace. Materials of construction
vary depending on the types of liquids to be gauged. Many different optional fea- tures are
available to meet your specifc needs. These materials and options, along with their pricing
impact, are summarized for each model in price list 6300. Magnetel gauges are designed
for working pressures ranging from atmospheric to 450 [31 Bar] psig.
When Ordering, Specify:
1. Liquid to be gauged and specifc gravity.
2. Inside diameter of tank, head style: ellipsoidal, semi-ellipsoidal or hemispherical.
3. Complete model number desired from price list 6300, (example M6342-11).
4. Prefx letters for available options from price list 6300.
5. If a dial other than standard is required, furnish drawing and/or details.
6. Furnish tank drawings whenever ordering gauges for angle-mounting or for installa-
tion in vertical tanks.
7. Tank mounting fange, if required (see chart).
NOTE: The dimensions of the threaded neck on this adapter are equivalent to Schedule 80 pipe.
CAUTION: For LP Gas or NH3 applications requiring 2 NPT connection, specify Y6300 Series
Magnetel gauges which includes 0022-00525 schedule 80 adapter assembled to gauge.
99/16 [243]
Diameter
29/16 [65]
From Tank Flange Maximum
Ceramic Pointer Magnet
Alnico Magnet
High and Low Float Arm Stop
140 Float Travel
4.75 [120]
2 NPT
3.5
[89]
2.32
[59]
4.75 [120]
2 NPT
3.5
[89]
1.93 [49]
Drawing A
Drawing B
MFR#
MATES
WITH TYPE MATERIAL THREADS DIMENSIONS WEBB#
0022-00029 6300 Series 21/2 NPT
Forged Steel 1/2 - 13 UNC-2B
Reference dwg A 275098
0022-00525
Y6300
Series Only
2 NPT sch. 80 Reference dwg B
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
111
6
SECTION
6
Gauges
Magnetel
Rough Rider
Liquid-Level Gauges
M6300
Application
The M6300 series Magnetel Rough Rider gauges were designed to withstand the
vibration and shock inherent in mobile service. Their service life in over-the-road and
off-road transports, carrying liquids ranging from LP-gas to crude oil, is unsurpassed.
These gauges allow a continuous reading between 5% and 95% of tank contents.
General Information & Features
The Magnetel Rough Rider gauges are to be installed in the side or end of mobile tanks
at the centerline. They are equipped with an exclusive spring controlled shock absorber
on the foat arm which substantially reduces the stress that quickly destroys conventional
gauges. Angle mounting gauges are also available.
The M6339 incorporates a 4 [100 mm] dial and the 6342 incorporates an 8
[200 mm] dial. When necessary, the dials are easily replaceable. Refer to price list P6300
for available types, part numbers, etc., as well as other replacement parts and accessories.
Price list M6300 includes information on materials of construction, available options, and
sales and pricing policy. The Magnetel Rough Rider gauges are designed for working
pressures ranging from atmospheric to 450 [31 Bar] psig.
When Ordering, Specify:
1. Liquid to be gauged and specifc gravity.
2. Inside diameter of tank heads, ellipsoidal, semi-ellipsoidal or hemispherical.
3. Complete model number desired from price list 6300, (example M6342-11).
4. Prefx letters for available options from price list 6300.
5. If a dial other than standard is required, furnish drawing and/or details.
6. Furnish tank drawings whenever ordering gauges for angle-mounting or for
installation in vertical tanks.
7. If tank mounting fange is required, order separately from chart above.
Drawing A
MFR#
MATES
WITH TYPE MATERIAL THREADS DIMENSIONS WEBB#
0022-00029 6300 Series 21/2 NPT Forged Steel 1/2 - 13 UNC-2B Reference dwg A
MFR# DESCRIPTION WEBB#
CM6339-11-72 Magnetel 72 Diameter Tank-4 Dial 275104
CM6339-11-79 Magnetel 79 Diameter Tank-4 Dial 275102
MFR# DESCRIPTION WEBB#
0015-00019 Gasket-Spiral Wound 275100
0022-00029 21/2 MNPT 31/2 Bold Flange 275098
5137S01262 4 Dial-LPG And NH3 275125
0093S00001 4 Dial Brackets 275129
0040-00413 SS 4 Dial Bracket Screws 275135
0044-00403 Nut-Magnetel Flange 275134
0044-00404 Bolt Magnetel Flange 275130
Rough Rider-Bobtails
Parts and Adapters
112
victormfg.com
Gauges
6
SECTION
Gas Equipment Catalog
Gauges
The Eliminator
Rotogauge Replacement
For LP Gas & NH3 Service
P6293 Series
Application
The Eliminator direct-reading foat gauge is a direct replacement for 1 NPT rotary-type
dip-tube gauges in LP and NH3 storage tanks. These gauges are designed for larger tanks
up to 84 [2134mm] in diameter. The Eliminator is not intended for use in flling tanks
- its use is restricted to tanks with fxed liquid level gauges, used to determine when the
maximum fll level has been reached. The eliminator can be used in mobile applications up
to 60 [1524mm] in diameter.
How To Do The Conversion
1. After the storage tank has been evacuated, remove the rotary gauge from the 1 NPT
opening at the centerline of the head. Clean and re-tap the female threads.
2. Remove the 2 screws from the bezel. Put the bezel, screws and dial chamber
aside for the moment. Remove the 4 mounting screws holding the gauge head
to the adapter.
3. Insert the lower portion of the replacement gauge, including the foat bulb, foat
arm, gear housing and counterbalance, into the tank opening.
4. Apply three wraps of 1/2 [12mm] wide Tefon tape, or other suitable thread sealant,
to the 1 NPT threads on the steel adapter through which the gauge support passes.
5. Screw the adapter into the tank opening to achieve a leak-tight joint, and align the
gauge mounting holes in the horizontal plane.
6. Using the gasket and four mounting screws supplied, attach the gauge to the
adapter fngertight. Be sure the gauge is right side up, the bracket tab for locating
dial chamber should be on the right. Torque the mounting screws evenly to
140/150 lbs.in., [16,4Nm] using a cross pattern.
7. Reattach the 4 dial chamber and bezel to the Senior gauge head brackets using
the two screws supplied.
8. If you end up with the dial chamber upside down, you cannot solve the problem by
rotating the bracket. You must rotate the entire gauge 180.
When ordering, specify:
1. Model number.
2. Tank I.D.
3. Shape of the head.
Warning: Carefully ensure that gauge and adapter are adequately protected from damage
that might cause leakage of tank contents.
Special Order
MFR# MATES WITH WEBB#
P6293-R4400 Up to 44
P6293-R6000 44 - 60
P6293-R7200 61 - 72
P6293-R8400 73 - 84
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
113
6
SECTION
6
Gauges
Magnetic Liquid-Level Gauges
for LP Gas Service
7200/B7200
Application
The 7200 and B7200 Series Junior gauges are identical except the former has a zinc die-
cast head and the latter has a forged-brass head. Both types have 11/4 Male NPTF threads
and 2 [51] hex-wrenching sections and are equipped with direct-reading dials appropriate
for the tanks in which they are installed.
General Information & Features
Model 7281 and B7281 direct-indicating gauges are for top mounting. When used on above-
ground ASME, horizontal, domestic storage tanks, they are equipped with 5323S01749
percentage or 5323S01789 fractional dials. When used on tanks buried underground, they
are equipped 5323S01813 percentage dials. Most 420# [190 kg] vertical cylinders utilize the
5323S01835 dial. For dials used on other vertical cylinders, contact Rochester.
Model 7284 and B7284 gauges are for side, end or angle mounting. When used
on ASME motor-fuel tanks they are equipped with 5323S01789 fractional dial.
Please contact Rochester for the part numbers of the various dials used on gauges
mounted in lift-truck cylinders.
General Specifcations
Temperature Range
Standard range is -40F to 158F, -40C to 70C.
Accuracy
Dependent on proper sizing of gauge and tank confguration. With direct reading dials,
overall accuracy is 5%; with TwinSite Sender, overall accuracy is 5%.
Current
TwinSite versions, 200 mA. maximum
Voltage
TwinSite versions, 12 and 24 volts.
Working Pressure
375 psig [25, 8 Bar].
Approvals
Gauges are appropriately UL listed for LP Gas liquid-level service and/or LP Gas
automotive accessories.
When ordering, specify:
1. The tank inside diameter (shown on tank nameplate).
2. The mounting location (top, side, end or angle).
3. If the gauge is angle mounted, state the degree of angle above or below the
horizontal centerline.
4. If the gauge is end mounted, state the shape of the tank head (hemispherical or
semi-ellipsoidal).
5. The H dimension. This is the distance in inches from the surface of the tank to the
top of the threaded opening.
Typical Gauge
114
victormfg.com
Gauges
6
SECTION
Gas Equipment Catalog
Gauges
Is the gauge right for your application?
Gauges should only be installed in applications recommended by the manufacturer. Verify
that the gauge is the proper gauge for your application prior to attempting installation.
The foat may or may not have a counterbalance depending on the intended
application. Applications for light specifc gravity liquids or large tanks normally require
counterbalancing of the foat.
The gauge, mounting gasket and mounting adapter (if applicable) must be constructed of
materials compatible with the liquid to be measured and the service environ ment. The
foat, mounting screws and head must be adequately rated for your specifc pressure and
temperature service.
Is the gauge the proper size?
As a general rule, the foat pivot point should be on the horizontal centerline of the tank
when installed. The foat length dimension (measured from the foat pivot point to the end
of the foat) should be proportional to the inside tank height and is usually slightly less than
1/2 of the vertical inside height of the tank.
Gauges can be constructed for side, top or angle mounting but must be installed in the
position for which they are constructed. Hold the gauge by the support (see Figure A) in the
intended mounting attitude and operate the foat to see if it is correct for your application
(see Figure B).
Jr. & Sr. Gauge Installation
MS-501/502
CAUTION: Improper gauge or dial selection or application may result in inaccurate readings. Release
of tank contents as well as damage to equipment and safety hazard may result if tank is overflled. Fuel
exhaustion may occur if tank contents are less than indicated. LP Gas & NH3 gauge dials require an
appropriate temperature chart.
WARNING: This gauge is not a substitute for a fxed liquid level gauge or weight measurement device,
which may be required for flling.
GAUGE REMOVAL WARNING: Should it appear necessary to remove the gauge from the tank, do not
attempt removal unless under competent supervision with all due precautions taken against the hazards of
released liquid or high pressure and/or fammable gas.
HAZARDS: A hazard of fre or explosion may exist if proper methods are not used when removing or
installing the gasket. Replace gasket if gauge head is removed. Do not reuse gasket. When reinstalling
gauge align head for proper orientation of the foat inside tank.
Installation
Check color stripe on O.D.
of gasket for material.
BLUE STRIPE= NEOPRENE. Order Senior
part # 0015-00836 or Junior part # 0015-
00855 recommended for anhydrous ammonia
and specifc refrigerant applications.
RED STRIPE= BUNA-N. Order Senior
part # 0015-00004 or Junior part # 0015-
00007, recommended for specifc LP Gas &
petroleum applications.
BROWN STRIPE = VITON.
Order Senior part # 0015-00415 or
Junior part # 0015-00039.
WHITE GASKET = TEFLON.
Order Senior part # 0015-00401 or
Junior part # 0015-00405.
SPIRAL WOUND TEFLON AND STAINLESS
STEEL. Order Senior part # 0015-00462.
CAUTION: Use spiral wound gasket only with stainless
steel gauge head and allen head cap screws.
A. Fit gasket onto gauge boss.
B. Carefully insert foat into adapter or cou-
pling and work gauges gear housing and
support through adapter being careful not
to bend or damage them.
C. Check to see that gasket is properly sealed
in adapter gasket recess.
D. Align head for proper orientation of
foat inside of tank. Torque screws evenly
in several steps to the desired torque value.
When torquing use a crossing torque pattern.
CAUTION: Do not over torque. Do not re-torque later unless leaking.
Over tightening may cause damage to head and gasket.
SCREW SIZE DRY TORQUE GASKET TYPE
1/4 28 20 TO 50 IN.LBS [2,3 to 5,6 Nm] BUNA, NEOPRENE, VITON, TEFLON
5/16 24 30 TO 60 IN.LBS [3,4 to 6,8 Nm] BUNA, NEOPRENE, VITON, TEFLON
5/16 24 140 TO 150 IN.LBS [15,8 to 16,9 Nm] SPIRAL WOUND GASKET
Figure A
Figure B
MS 502 Sr. Gauges
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
115
6
SECTION
6
Gauges
These instructions are prepared to assist tradesmen and others generally familiar with liquid
storage tank equipment. Consumers are not qualifed to perform the installation described
below. If you have any questions concerning installation or operation of the gauge, contact
Rochester Gauges or one of our authorized distributors for assistance. This document is not
instructions for tank flling.
MS-516
Figure A
Figure B
An American National Standard Pipe Threads, General Purpose (INCH)
ANSI/ASME B1.20.1-1983
(Varnish threads due to chamfer on die.)
MFR# TANK SIZE WEBB#
6281-15.5-30 320 Gal-30 Diameter 275099
6281-19.25-37 500 Gal-37.5 Diameter 275097
6281-21-41 1000 Gal-41 Diameter 275096
6281-89 200# Vertical 275095
6281-85 420# Vertical 184087
Jr. Flange
Sr. Flange
MFR# TANK SIZE WEBB#
6280-00630 320 Gal-30 Diameter
6280-00637 500 Gal-37.5 Diameter
6280-00641 1000 Gal-41 Diameter
6280-01235 200# Vertical
6280-192 420# Vertical 275101
MFR#
TANK
SIZE WEBB#
B8981-01232
320 Gal-30
Diameter
B8981-1237
500 Gal-37.5
Diameter
361808
B8981-1241
1000 Gal-41
Diameter
359343
B8981-01235 200# Vertical
B8981-2009 420# Vertical 275106
1 NPT
MFR#
TANK
SIZE WEBB#
B7281-130
320 Gal-30
Diameter
275114
B7281-137
500 Gal-37.5
Diameter
275112
B7281-141
1000 Gal-41
Diameter
275111
B7281-00388 200# Vertical
B7281-00386 420# Vertical 372633
11/4 NPT
DIAL WEBB#
5909S02733 184077
5909S02733 184077
5909S02733 184077
5909S02772 275109
5909S02772 275109
DIAL WEBB#
5986S02733 184073
5986S02733 184073
5986S02733 184073
5986S02772 275107
5986S02772 275107
DIAL WEBB#
5909S02733 184077
5909S02733 184077
5909S02733 184077
5909S02772 275109
5909S02772 275109
DIAL WEBB#
5909S02733 184077
5909S02733 184077
5909S02733 184077
5909S02772 275109
5909S02772 275109
116
victormfg.com
Gauges
6
SECTION
Gas Equipment Catalog
Gauges
NOTE: Check color stripe on O.D. of gasket for material.
Senior = 2.06 [52,3] nominal diameter Junior = 1.56 [39,6] nominal diameter
BLUE STRIPE = NEOPRENE
RED STRIPE = BUNA-N
BROWN STRIPE = VITON
WHITE GASKET = TEFLON
SPIRAL WOUND TEFLON AND STAINLESS STEEL
5/16 24 screw 30 to 60 In. Lbs., [3,4 to 6,8 Nm] using a crossing pattern.
1/4 28 screw 20 to 50 In. Lbs., [2,3 to 5,6 Nm] using a crossing pattern.
#10 screw 20 to 25 In. Lbs. [2,3 to 2,8 Nm] using a crossing pattern.
Replacing Gaskets
115-793
Replacement Dials
115-794
Advanced Matrix TwinSite
Junior TwinSite
Junior Direct Reading
MFR# DESCRIPTION WEBB#
ROG0040-00414 Screw Head, Jr. 184067
ROG0040-00415 Screw Head, Sr. 184068
ROG0015-00004 Gasket, Sr. Gauge 184063
ROG0015-00007 Gasket, Mounting Jr. 184064
ROG5909S02733 Dial, Jr. W/5-1749 184077
ROG5323S01789 Dial, Jr. f/331/2 184098
ROG5909S02772 Underground ASME Rep. 275109
RBSRS-228 Remote Level Indicator 314605
R3D Dials-Remote Ready
MFR# DESCRIPTION WEBB#
5909S02733 Jr. ASME Above Ground 184077
5909S02799 Jr. ASME Under Ground 275108
5986S02733 Sr. AMSE Above Ground 184073
5909S02772 Jr. 10-82% Vertical 200/420S 275109
5986S02772 Sr. 10-82% Vertical 200/420S 275107
5987S02787 JY Taylor Style A 273836
5988S02788 JY Taylor Style B 275105
5988S02889 Jr. Taylor Vertical 420S Style B 359345
MFR# DESCRIPTION WEBB#
0015-00004 Sr. Gasket 184063
0015-00007 Jr. Gasket 184064
0040-00414 Jr. Screw 184067
0040-00415 Sr. Screw 184068
0040-00675 Jr. Screw For Brass Head 372635
Screws and Gaskets
MFR# DESCRIPTION WEBB#
5323S01789 Jr. Fractional 33 1/3# 184098
5714S02591 Snap On 33 1/3# 283967
5364S01951 Snap On 200/420s No Remote 184082
5AAAS02772 Snap On 200/420s With Remote 415723
Jr. Dials-Direct Read
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
U
G
E
S
Gauges
117
6
SECTION
6
Gauges
Pressure Gauges
MFR# DESCRIPTION WEBB#
21/2 Dial, 1/4 Brass Lower Mount, ABS Case
ASH95449 0-30 w.c. 173954
SJIGGAUGE 0-5 PSI 84202
PROP15 0-15 PSI 36483
PROP30 0-30 PSI 36484
PROP60 0-60 PSI 36485
PROP100 0-100 PSI 36486
PROP160 0-160 PSI 36487
PROP200 0-200 PSI 36488
PROP300 0-300 PSI 36489
ASH10256 0-30 PSI 36490
ASH15039 0-600 PSI 36491
ASH14223 0-1000 PSI 36492
21/2 Dial, 1/4 Brass Back Mount, ABS Case
ASH00165 0-30 PSI 77875
ASH00166 0-60 PSI 77876
ASH00167 0-100 PSI 77877
ASH00168 0-160 PSI 77878
ASH00169 0-200 PSI 176518
4 Dial, 1/4 Brass Lower Mount, ABS Case
ASH12194 0-15 PSI 36496
ASH00260 0-30 PSI 36497
ASH00261 0-60 PSI 36498
ASH00262 0-100 PSI 36499
ASH00263 0-160 PSI 36500
ASH00264 0-200 PSI 36501
ASH14143 0-300 PSI 36502
21/2 Liquid Filled Dial, 1/4 Brass Lower Mount, ABS Case
ASH00511 0-15 PSI 110914
ASH00512 0-30 PSI 110915
ASH00513 0-60 PSI 110916
ASH00509 0-100 PSI 110917
ASH00514 0-160 PSI 110918
ASH00515 0-200 PSI 110919
ASH00516 0-300 PSI 110920
ASH00517 0-400 PSI 110921
118
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
Flexible Gas Tubing
MFR# SIZE PKG. QTY WEBB#
Corrugated Stainless Steel 300 Series With Polyethylene Jacket
TRP-SS4-375-100 3/8 100 Reel 216967
TRP-SS4-375-250 3/8 250 Reel 216966
TRPSS4-500-50 1/2 50 Reel 250002
TRP-SS4-500-100 1/2 100 Reel 219618
TRP-SS4-500-250 1/2 250 Reel 87389
TRPSS4-750-50 3/4 50 Reel 250003
TRP-SS4-750-100 3/4 100 Reel 219619
TRP-SS4-750-250 3/4 250 Reel 87390
TRPSS4-100-50 1 50 Reel 250001
TRP-SS4-100-180 1 180 Reel 87391
TRPSS4-125-50 11/4 50 Reel 250000
TRP-SS4-125-150 11/4 150 Reel 205453
TRP-SS4-150-150 11/2 150 Reel 219620
TRP-SS4-200-150 2 150 Reel 219621
Description/Dimensions
* EHD (Effective Hydraulic Diameter) A relative measure of Flow Capacity. This number is used to compare individual sizes between different manufacturers.
The higher the EHD number the greater fow capacity of the piping.
Underground TracPipe
MFR# SIZE PKG. QTY WEBB#
TRPUG375-100 3/8 100 Coil 216985
TRPUG500-100 1/2 100 Coil 216986
TRPUG750-100 3/4 100 Coil 216987
TRPUG100-100 1 100 Coil 216988
TRPUG125-100 11/4 100 Coil 216989
TRPUG125-200 11/4 200 Coil 241888
TRPUG150-100 11/2 100 Coil S720800
TRPUG150-200 11/2 200 Coil 242755
TRPUG200-200 2 200 Coil 242756
MFR# SS4-375 SS4-500 SS4-750 SS4-100 SS4-125 SS4-150 SS4-200
Size (inch) 3/8 1/2 3/4 1 11/4 11/2 2
EDH (AGA Size)* 15 19 25 31 37 46 62
Jacket O.D. (max.) .668 .868 1108 1.38 1665 1920 2590
Inside Diameter (nom.) .440 .597 820 1.040 1290 1525 2060
Wall Thickness (in.) .01 .01 .01 .01 .012 .012 .012
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
119
7
SECTION
7
Counterstrike Tubing
MFR# TUBING SIZE PKG. QTY WEBB#
TRPCS-375-250 3/8 250 Reel 368348
TRPCS-500-100 1/2 100 Reel 368349
TRPCS-500-250 1/2 250 Reel 368160
TRPCS-750-100 3/4 100 Reel 368350
TRPCS-750-250 3/4 250 Reel 368159
TRPCS-100-180 1 180 Reel 368344
TRPCS-125-150 11/4 150 Reel 368345
TRPCS-150-150 11/2 150 Reel 368346
TRPCS-200-150 2 150 Reel 368347
Installation Bulletin for CounterStrike
CounterStrike
Fittings
Brass Fitting AutoFlare Insert
Straight Mechanical Fittings, Reducing Fittings
MFR# TYPE SIZE PKG. QTY. WEBB#
TRP-FST-375 Straight 3/8 (1/2 NPT) 24/box 216968
TRP-FST-500 Straight 1/2 24/box 87393
TRP-FST-750 Straight 3/4 16/box 87394
TRP-RST750-500 Reducing 3/4 - 1/2 NPT 16/box 219624
TRP-FST-1000 Straight 1 16/box 87395
TRP-RST1000-750 Reducing 1 - 3/4 NPT 16/box 219625
TRP-FST-1250 Straight 11/4 6/box 205454
TRP-FST-1500 Straight 11/2 4/box 219622
TRP-FST-2000 Straight 2 4/box 219623
Straight Fitting
Reducing Fitting
Termination Mount, Meter Termination
MFR# TYPE PKG. QTY. SIZE WEBB#
TRP-TM-375 Termination Mount 12/Box 3/8 217405
TRP-TM-500 Termination Mount 12/Box 1/2 217406
TRP-TM-750 Termination Mount 8/Box 3/4 217407
TRP-TM-1000 Termination Mount 8/Box 1 219626
TRP-90TM-375 90 Termination Mount 8/Box 3/8 217401
TRP-90TM-500 90 Termination Mount 8/Box 1/2 217402
TRP-MT6-500 6 Meter Termination 1 ea. 1/2 246855
TRP-MT12-500 12 Meter Termination 1 ea. 1/2 246856
TRPMT6-750 6 Meter Termination 1 ea. 3/4 250428
Flange Fittings
TRP-BFF-375 Iron Flange Brass 12/box 3/8 216975
TRP-BFF-500 Iron Flange Brass 12/box 1/2 87398
TRP-BFF-750 Iron Flange Mount Brass 8/box 3/4 87399
TRP-BFF-1000 Iron Flange Mount Brass 8/box 1 87376
TRP-BFF-1250 Iron Flange Mount Brass 4/box 11/4 216976
TRP-TERM-BRAC Flange Bracket 1 ea. All 222077
TRP-ELLS-375 90 Elbow Flange Mount 8/box 3/8 216981
TRPFGP-ELLS-500 90 Elbow Flange Mount 8/box 1/2 216982
Grounding Clamps
VCTC11N 1/2, 3/4 1 372312
VCTC22 11/4 - 2 372313
Termination Mount
90 Termination Mount
Meter Termination
TracPipe by TracPipe Outlet
Flange Mount Fitting
90 Elbow
Flange Mount
Mounting
Bracket
MFR# TYPE SIZE WEBB#
TRPT500-500 Tee 1/2 FIP 222078
TRPT750-750 Tee 3/4 FIP 222084
TRPT750-500 Tee 3/4 X 1/2 FIP 308740
TRPT1000-1000 Tee 1 FIP 222080
TracPipe by Pipe Outlet
TracPipe by Pipe Outlet Tee
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
121
7
SECTION
7
Accessories
MFR# DESCRIPTION SIZE PKG. QTY WEBB#
TRPSP-025 Quarter Striker Plate 3 X 2 500/box 87381
TRPSP-050 Half Striker Plate 3 X 7 100/box 87380
TRPSP-100 Full Striker 3 X 12 50/box 87379
TRPFGP-SF-617 Large Plate 61/2 X 17 276535
Half Striker
Full Striker Plate
Quarter Striker
MFR# DESCRIPTION SIZE PKG. QTY WEBB#
TRPFPY-375 Floppy Fits 3/8 3/4 50 Coil 216969
TRPFGP-FPY-500 Floppy Fits 1/2 1 50 Coil 216970
TRPFGP-FPY-750 Floppy Fits 3/4 11/4 25 Coil 216971
TRPFGP-FPY-1000 Floppy Fits 1 11/2 25 Coil 216972
TRPFPY-1250 Floppy Fits 11/4 2 25 Coil 205456
TRPFPY-1500 Floppy Fits 2 21/2 25 Coil 216973
Floppy Galvanized Steel Conduit
Floppy Strip Wound Conduit
MFR# DESCRIPTION SIZE PKG. QTY WEBB#
TRP-MI-PC Coated Manifold 3/4 X 1/2 X 1/2 (4) 1 ea. 246854
TRP-MB2 Manifold Bracket * 1 ea. 217403
TRPTERM-BRAC Flange L Bracket * 1 ea. 222077
TRPP-LC Load Center With Bracket * 1 ea. 216983
TRPFGP-MI-PC-1X Coated Manifold 11/4 X 1 X 3/4 (4) 1 ea. 256174
Manifolds
Coated Manifold
Load Center
With Bracket
Manifold Bracket
MFR# SIZE WEBB#
TRPRING-375 3/8 Spare 222083
TRPRING-500 1/2 Spare 242572
TRPRING-750 3/4 Spare 247210
Spare Split Rings
Striker Plates
MFR# SIZE WEBB#
TRPHST-12 1/2 216991
TRPHST-34 3/4 216992
TRPHST-1 1 216993
TRPHST-300 11/4 216994
TRPHST-350-6 11/2 242757
TRPHST-2 2 242758
Shrink Cuffs
(Two required for each run)
Underground TracPipe Accessories
Vent Tees
(Use when required by local codes)
MFR# SIZE WEBB#
TRPVT-125 3/8 and 1/2 216996
TRPVT-150 3/4 and 1 216997
TRPVT-200 11/4 242759
Shrink Cuffs
Vent Tees
TracPipe Pipe Wrap
MFR# DESC. WEBB#
TRP915-10H-12 Yellow Outdoor 242814
Pipe Wrap
TracPipe Tools
MFR# DESC. WEBB#
TRPTC-151 Tube Cutter for 3/8 11/4 205455
TRPTC-152 Tube Cutter for 11/4 2 216984 Tube Cutter
122
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
Safer Installation for Gas
Easy to Identify
Permanent yellow polyethylene coating.
Continuous line marking.
Traceable back to origin of manufacturing.
Mill test reports available upon request.
Easy to Install
No additional training required for installation.
Flexible
Easy to join
Compact size
Requires smaller and fewer tools than steel pipe.
Cleaner than threaded steel pipe.
Cost Effcient
Most economical line-marked tubing on the market.
Minimal labor costs due to quick and easy installation.
No on-site sleeving required for underground gas lines.
Recyclable
Copper is fully recyclable.
Copper has proven to be reliable and economical source for
interior natural gas and liquefed petroleum installations for
over 25 years. Its use has introduced vertical subdivision
concepts, individual metering and new add-on markets.
Coppers demand ranges from single-family dwellings
to row houses to multi-story apartments. Within these
dwellings, gas can be a source for furnaces, room heaters,
air conditioning units, gas-fred heating boilers and domestic
hot water heaters. Gas also economizes the use of cooking
ranges, clothes dryers, gas freplaces, gas barbeques and
decorative gas lamps.
Coated Copper Tubing
For Natural Gas and Liquefed Petroleum Gas
Standard Copper Tubing
Can Gas-Tec be used underground?
Yes, our material can be direct buried. In Canada, Gas-Tec
G/Gas is currently the only tubing that can be used both
above and below ground without any modifcation. In the
United States, most areas allow Gas-Tec Refrigeration grade
or Type L tubing to be buried, but we recommend our
Gas-Tec type L (G/Gas) due to the heavier wall thickness
on most sizes.
NOMINAL OUTSIDE WALL STANDARD
SIZE DIAMETER THICKNESS LENGTHS*
1/4 L 3/8 G/Gas .030 30 60 100 250
3/8L 1/2 G/Gas .035 30 60 100 250
1/2L 5/8 G/Gas .040 30 60 100 250
5/8L 3/4 G/Gas .042 30 60 100
3/4L 7/8 G/Gas .045 30 60 100
MFR # SIZE LENGTH WEBB#
REFRIGERATION TUBING
C/T38OD 3/8 50 2582
C/T38OD100 3/8 100 58835
C/T12OD 1/2 50 2583
C/T12OD100 1/2 100 58836
C/T58OD 5/8 50 2584
C/T58OD100 5/8 100 58837
K TUBING
C/T38K60 3/8 60 2526
C/T38K100 3/8 100 191720
C/T12K60 1/2 60 2539
C/T12K100 1/2 100 150326
C/T58K60 5/8 60 111921
L TUBING
C/T38L60 3/8 60 2552
C/T38L100 3/8 100 190614
C/T12L60 1/2 60 2553
C/T12L100 1/2 100 91639
OUTSIDE WALL STANDARD
DIAMETER THICKNESS LENGTHS*
3/8 .032 25 50 100 250
1/2 .032 25 50 100 250
5/8 .035 25 50 100 250
* Custom sizes available upon request
MFR# SIZE WEBB#
General Purpose, Yellow Coating
KMCPC38OD50 3/8 X 50 190668
KMCPC12OD50 1/2 X 50 190669
KMCPC58OD50 5/8 X 50 190670
KMCPC380D100 3/8 X 100 190671
KMCPC120D100 1/2 X 100 190672
KMCPC580D100 5/8 X 100 190673
KMCPC380D250 3/8 X 250 191023
KMCPC120D250 1/2 X 250 191024
KMCPC580D250 5/8 X 250 245837
Oil Tech, Orange Coating
KMC38X50CTD 3/8 X 50 201445
KMC12X50CTD 1/2 X 50 213315
KMC38X100CTD 3/8 X 100 201446
KMC12X100CTD 1/2 X 100 213316
Type L
KMCPC38L60 3/8 X 60 190674
KMCPC12L60 1/2 X 60 190675
KMCPC58L60 5/8 X 60 190676
KMCPC38L100 3/8 X 100 191820
KMCPC12L100 1/2 X 100 191821
Type L-G/Gas, ASTM B88/B837
General Purpose, ASTM B68/B280 Refrigeration
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
123
7
SECTION
7
MFR# SIZE WEBB#
DLKDL6-3 3/8 X 3 184977
DLKDL8-3 1/2 X 3 184978
DLKDL8-6 1/2 X 6 184979
DLKDL12-3 3/4 X 3 184975
DLKDL12-6 3/4 X 6 184976
MFR# DESCRIPTION WEBB#
VCT93UT-08 In-Line Low 361067
Pressure Sediment Trap
Drip Leg Packages
In-Line Trap
MFR# DESC. WEBB#
HFBLP350X34X1FT 3/4 X 1 FT 438652
HFBLP350X34X3FT 3/4 X 3 FT 438653
HFBLP350X34X12FT 3/4 X 12 FT 438654
HFBLP350X34X18FT 3/4 X 18 FT 438655
HFBLP350X34X20FT 3/4 X 20 FT 438656
HFBLP350X34X50FT 3/4 X 50 FT 438657
HFBLP350X1X15FT 1 X 15 FT 438658
HFBLP350X1X100FT 1 X 100FT 438659
HFBLP350X1X150FT 1 X 150 FT 438660
Gates Bulk Hose
Spiral Reinforced
Series 7132 LP Gas Hose
Features a smooth, abrasion resistant cover and the
fexibility of the 4 spiral reinforcements result in a hose that
is easier to handle and glides smoothly over any surface.
Tube: Black Nitrile.
Cover: Perforated Black Neoprene.
Reinforcement: Multiple Textile Braids.
Temp. Range: -50F to 180F.
Certied & Tested
Underground
PE Gas Pipe
MFR# SIZE WEBB#
YGP12CTS090-75 1/2 CTS X 75 378760
YGP12CTS090-100 1/2 CTS X 100 193140
YGP12CTS090-150 1/2 CTS X 150 319632
YGP12CTS090-200 1/2 CTS X 200 193141
YGP12CTS090-500 1/2 CTS X 500 183524
YGP12SDR93-100 1/2 IPS X 100 165738
YGP12SDR93-150 1/2 IPS X 150 165739
YGP12SDR93-200 1/2 IPS X 200 165740
YGP12SDR93-500 1/2 IPS X 500 183399
YGP34SDR11-50 3/4 IPS X 50 165571
YGP34SDR11-75 3/4 IPS X 75 263102
YGP34SDR11-100 3/4 IPS X 100 165741
YGP34SDR11-150 3/4 IPS X 150 165742
YGP34SDR11-500 3/4 IPS X 500 183429
YGP1CTS099-500 1 CTS X 500 183525
YGP1SDR11-100 1 IPS X 100 165572
GP1SDR11-150 1 IPS X 150 165743
YGP1SDR11-200 1 IPS X 200 165744
YGP1SDR11-500 1 IPS X 500 183430
YGP114SDR11-100 1-1/4 IPS X 100 165573
YGP114SDR11-150 1-1/4 IPS X 150 165745
YGP114SDR11-200 1-1/4 IPS X 200 165746
YGP114SDR11-500 1-1/4 IPS X 500 183431
YGP112SDR11-150 1-1/2 IPS X 150 165575
YGP112SDR11-500 1-1/2 IPS X 500 183432
YGP2SDR11-100 2 IPS X 100 165749
YGP2SDR11-200 2 IPS X 200 165751
YGP2SDR11-500 2 IPS X 500 183433
124
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping Systems
Lower Installation Costs Fewer Repairs Over Time
Residential Application
Lyall provides a wide variety of product sizes and confguration to meet residential needs.
LYCOFIT
Mechanical Fittings
LYCOFIT
provides the installer with a full visual quality check frst pipe-on and the
sleeve on in each installation for a gas tight connection.
The LYCOFIT
Mechanical Fittings
MFR# DESCRIPTION WEBB#
3-Way Tee Couplings
LYCLC010B-3TR 1/2 CTS 179029
LYCLC030B-3TR 1 CTS 179031
LYCLC050W-3TR 1/2 IPS 183470
LYCLC060Y-3TR 3/4 IPS 183467
LYCLC070Y-3TR 1 IPS 179037
LYCLC080X-3TR 11/4 IPS 183520
LYCLC200Y-3TR 2 IPS 183469
90 Elbow Couplings
LYCLC050W-ELR 1/2 IPS 183462
LYCLC010B-ELR 1/2 CTS 179040
LYCLC030B-ELR 1 CTS 179042
LYCLC060Y-ELR 3/4 IPS 183458
LYCLC070Y-ELR 1 IPS 183459
LYCLC080X-ELR 11/4 IPS 183460
LC200Y-ELR 2 IPS 183461
Repair Couplings
LYCLC080X-DER 11/4 IPS 179086
LYCLC200Y-DER 2 IPS 179087
End Caps
LYCLC010B-ECR 1/2 CTS 179014
LYCLC050W-ECR 1/2 IPS 183457
LYCLC060Y-ECR 3/4 IPS 179021
LYCLC070Y-ECR 1 IPS 183455
LYCLC080X-ECR 11/4 IPS 179023
LYCLC200Y-ECR 2 IPS 179024
Steel Pipe to PE Pipe Transitions
LYCLC050S050W-SPB 1/2 NPT X 1/2 IPS 274130
LYCLC060S060YSPB 3/4 NPT X 3/4 IPS 183510
LYCLC070S070YSPB 1 NPT X 1 IPS 183511
LYCLC080S080XSPB 11/4 NPT X 11/4 IPS 183512
LYCLC200S200YSPB 2 NPT X 2 IPS 179062
126
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping Systems (continued)
LYCOFIT
Installation Tools
Tools that make every job quick and easy.
LYCOFIT
couplings from
3/4 IPS through 2 IPS.
128
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
R.W. Lyall Propane Piping Systems (continued)
Specifcations
Meets or exceed all requirements for the Categorization of Mechanical Fittings within
ASTM D2513-90c Category 1, and requirements from the Code of Federal Regulations,
Title 49 Part 192.281 and 192.283.
Meets or exceeds NFPA-58 1002, DOT and ISO requirements.
Listed with IAPMO/UPS and CSA
Conforms to the Mechanical Fitting Specifcation as defned in ASTM F 1924.
A complete set of specifcations and test results for the product are available upon request.
Large Auto Press (LAP-100)
This heavy duty hydraulic tool is designed to provide thousands of worry free installations
quickly and easily. Installs 11/4, 11/2 and 2 IPS LYCOFIT
couplings.
MFR# DESCRIPTION WEBB#
Hydraulic Tool & ENERPAC
LYCLAP100 11/4 IPS 2 IPS 183440
LYCAHP100 ENERPAC 183535
LYCHYDPRESS Kit 191819
LycoRing
Lightweight, disposable plastic ring that easily slips over the PE pipe and securely grips the
pipe while inserting the pipe onto the LYCOFIT
ftting and eliminates the need for additional gripping tools to install fttings.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
129
7
SECTION
7
130
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
The CONSTAB CHAMFER tool is required for all CONSTAB ttings.
Other Manufactureres tools will not produce a gas-tight connection.
MFR# SIZE WEBB#
Corrugated Stainless Steel 300 Series With Polyethylene Jacket
CST0000-33-6580-04 1/2 CTS 371814
CST0000-33-6580-12 1/2 IPS 411913
CST0000-33-6580-13 3/4 IPS 371810
CST0000-33-6580-08 1 CTS 411526
CST0000-33-6580-14 1 IPS 371811
CST0000-33-6580-10 1-1/4 IPS 371813
CST0000-38-6580-16 1-1/2 IPS 269646
CST0000-33-6580-17 2 IPS 371809
Chamfer Tools
The internal seal enables each ftting to seal on scratched pipe. A seal is maintained on the smooth inside surface of the
polyethylene pipe, regardless of the exterior surface of the piping. This improved seal protection creates the ultimate design
for mechanical joints.
Each Con-Stab ftting provides the following unique features:
Two internal seals
Fixed stiffener
Self-locking gripper
Moisture lip
Uni-body construction
The Con-Stab I.D. Seal fttings provide the user with the
following advantages:
Cost effective joining method
Simple assembly
No additional assembly equipment required for
installation ( just chamfer pipe and push)
Expanded product line with various confgurations and
material options (PE 3408/4710 or PE 2406)
Uni-body design eliminating all external parts
Meets or exceeds all D.O.T., ASTM and NFPA 58 requirements
Continental Industries is an ISO 9001 Certifed Company. Continentals Con-Stab I.D. Seal product line is manufactured
and tested to the following industry standards.
ASTM D 2513 Standard Specifcation for Thermoplastic Gas Pressure Pipe, Tubing and Fittings
ASME B31.8-1995 Gas Transmission and Distribution Piping Systems
D.O.T., Title 49 of the Code of Federal Regulations, Part 192.283 (b)
NFPA 58, LP-Gas Code
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
131
7
SECTION
7
Service Head Risers
Risers without Couplings
Risers with Couplings
Couplings
Connection is made above-ground. No tool or tting is required.
MFR# SIZE WEBB#
CST1253-92-1004-36 36 1/2 NPT X 1/2 CTS 261875
CST1253-92-1004-84 84 1/2 NPT X 1/2 CTS 261885
CST1253-92-1012-36 36 1/2 NPT X 1/2 IPS 261876
CST1252-92-1012-84 84 1/2 NPT X 1/2 IPS 261886
CST1353-92-1012-36 36 3/4 NPT X 1/2 IPS 261878
CST1353-92-1012-84 84 3/4 NPT X 1/2 IPS 261888
CST1353-92-1013-36 36 3/4 NPT X 3/4 IPS 261879
CST1353-92-1013-84 84 3/4 NPT X 3/4 IPS 261889
MFR# SIZE WEBB#
CST1253-91-4604-00 1/2 NPT X 1/2 CTS 193302
CST1353-91-4604-00 3/4 NPT X 1/2 CTS 192989
CST1353-91-4612-00 3/4 NPT X1 /2 IPS 180062
CST1353-91-4613-00 3/4 NPT X 3/4 IPS 180063
CST1453-91-4614-00 1 NPT X 1 IPS 183406
CST1553-91-4615-0A 1-1/4 NPT X 1-1/4 IPS 414143
CST1652-91-4616-00 1-1/2 NPT X 1-1/2 IPS 193897
CST1752-91-4617-00 2 NPT X 2 IPS 193898
MFR# SIZE WEBB#
CST1253-91-4604-25 1/2 NPT X 1/2 CTS 411528
CST1353-91-4604-25 3/4 NPT X 1/2 CTS 411530
CST1353-91-4612-25 3/4 NPT X 1/2 IPS 411533
CST1353-91-4613-25 3/4 NPT X 3/4 IPS 411534
CST1453-91-4614-25 1 NPT X 1 IPS 411542
CST9953-99-0503-25 1-1/4 NPT X 1-1/4 IPS 411589
CST1652-91-4616-25 1-1/2 NPT X 1-1/2 IPS 411547
CST1752-91-4617-25 2 NPT X 2 IPS 411548
MFR# SIZE WEBB#
CST3259-52-1004-00 1/2 CTS 269237
CST3259-52-1012-00 1/2 IPS 269238
CST3259-52-1013-00 3/4 IPS 269239
CST3259-52-1008-00 1 CTS 370557
CST3259-52-1014-00 1 IPS 269289
CST3259-52-1015-AA 1-1/4 IPS 269240
CST3259-52-1016-00 1-1/2 IPS 269645
CST3259-52-1017-00 2 IPS 269241
132
victormfg.com
Gas Pipe, Tubing & Fittings
7
SECTION
Gas Equipment Catalog
Reducing Couplings
Repair Couplings
Tees
Reducing Tees
90 Elbows
MFR # SIZE WEBB#
CST3259-54-1204-00 1/2 IPS X 1/2 CTS 269251
CST3259-54-1304-00 3/4 IPS X 1/2 CTS 269252
CST3259-54-1404-00 1 IPS X 1/2 CTS 269254
CST3259-54-1312-00 3/4 IPS X 1/2 IPS 269253
CST3259-54-1413-00 1 IPS X 3/4 IPS 269255
CST3259-54-1513-0A 1-1/4 IPS X 3/4 IPS 413038
CST3259-54-1514-00 1-1/4 IPS X 1 IPS 269257
CST3259-54-1615-0A 1-1/2 IPS X 1-1/4 IPS 269644
MFR# SIZE WEBB#
CST3238-14-4415-AA 1-1/4 IPS 371843
CST3238-14-4417-00 2 IPS 269267
MFR# SIZE WEBB#
CST3259-50-1004-00 1/2 CTS 269212
CST3259-50-1012-00 1/2 IPS 269213
CST3259-50-1013-00 3/4 IPS 269214
CST3259-50-1008-00 1 CTS 370558
CST3259-50-1014-00 1 IPS 269215
CST3259-50-1015-AA 1-1/4 IPS 370556
CST3259-50-1016-00 1-1/2 IPS 269648
CST3259-50-1017-00 2 IPS 269217
MFR# SIZE WEBB#
CST3259-49-1304-00 3/4 IPS X 1/2 CTS 269259
CST3259-49-1404-00 1 IPS X 1/2 CTS 269260
CST3259-49-1413-00 1 IPS X 3/4 IPS 269261
CST3259-49-1715-0A 2 IPS X 1-1/4 IPS 269262
MFR# SIZE WEBB#
CST3259-51-1004-00 1/2 CTS 269218
CST3259-51-1012-00 1/2 IPS 269219
CST3259-51-1013-00 3/4 IPS 269220
CST3259-51-1008-00 1 CTS 370559
CST3259-51-1014-00 1 IPS 269221
CST3259-51-1015-AA 1-1/4 IPS 370554
CST3259-51-1016-00 1-1/2 IPS 269647
CST3259-51-1017-00 2 IPS 269223
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
P
I
P
E
,
T
U
B
I
N
G
&
F
I
T
T
I
N
G
S
Gas Pipe, Tubing & Fittings
133
7
SECTION
7
Cap-N-Go Fittings
Cap End
Pex Copper Transition Couplings
MFR# SIZE WEBB#
CST3259-57-1004-00 1/2 CTS 269224
CST3259-57-1013-00 3/4 IPS 269225
CST3259-57-1015-0A 1-1/4 IPS 269226
CST3259-57-1017-00 2 IPS 269227
MFR# SIZE WEBB#
269242 CST3259-53-1004-00 1/2 CTS
269243 CST3259-53-1013-00 3/4 IPS
269244 CST3259-53-1014-00 1 IPS
370555 CST3259-53-1015-0A 1-1/4 IPS
269246 CST3259-53-1017-00 2 IPS
MFR# SIZE WEBB#
CST9943-99-0064-00 1/2 PE X 1/2 OD COPPER 269249
CST9943-99-0065-00 1/2 PE X 5/8 OD COPPER 269250
Underground Gas Line Markers
MFR# DESCRIPTION WEBB#
MISUD21 TAPE UNDERGROUND GAS 31-140 183516
VCTTRACERWIRE TRACER WIRE 500 14A 359306
ELE1207PE30-YE Tracer Wire 500 12A 243218
Anode Bags - 17 lbs
MFR# DESCRIPTION WEBB#
CPRANODE17 ANODE MAGNESIUM BAGS 183403
134
victormfg.com
Connectors
7
SECTION
Gas Equipment Catalog
Stainless Steel Gas Connectors
Residential Stainless Steel Gas Appliance Connectors
Dormonts complete line of fexible, corrugated, Supr-Safe
Connectors
DORA50 1/2 Snap Fast Connector 163860
DORA75 3/4 Snap Fast Connector 163861
Commercial Supr-Safe
The 780-910 Universal Hot Surface Ignition Module Uni-Kit is designed for use on gas
fred systems. It is equipped with a self diagnostic green LED for quick troubleshooting.
The LED indicates if the system is in normal operati on, has gone into lockout, has a
weak fame signal, or has an internal error (a defective module).
MFR# DESCRIPTION WEBB#
780-910 Universal Hot Surface Ignition Module 155174
Test Equipment
900-575 Module Tester
The 900-575 Test Kit is designed specifcally for the professional service technician. Now
an electronic ignition module intermittent pilot, direct spark, hot surface can be quickly
and accurately diagnosed at the job site. The 900-575 Tester will diagnose all the circuit
functions on an I.C.U. Checking for proper sequence of operation and/or failure. No more
guessing which part to replace. With the 900-575 change out the defective part the frst
time, not on a return call back.
MFR# DESCRIPTION WEBB#
900-575 Ignition Module Tester 152947
720001W Quick Look Tester Q/L 360275
900-575
780-910
780-785
150
victormfg.com
Ignition Modules
8
Gas Equipment Catalog
SECTION
Replacement Controls and Components
Ignition Control Units
780-015
Add-on lockout module. Using the 780-015 module with 780-715 module will give
application lockout timing function for use on LP gas, 60 second timing lockout
on pilot and main gas fow.
780-735
Lockout Model. Flame rectifcation system. Use with gas valves 7000 BDER and 7100 DER.
Has 60 second lockout timing.
780-845
Universal lockout model has three 90 second valve trials interrupted by a six minute
purge cycle before 100% lockout.
780-735
MFR# DESCRIPTION WEBB#
780-015 Non-Lockout Flame Rectifcation System
780-735 Lockout Flame Rectifcation System 73462
780-845 Gas Ignition Control 167191
Automatic Pilot Relight Kits
The Robertshaw 785 Series automatic Pilot Relight Kits are designed for use on rooftop
heating equipment, water heaters, boilers, space heaters, unit heaters, dryers, and other
commercial, industrial, and residential appliances where the problem of pilot outage may
occur. It should only be applied to those systems which already incorporate the necessary
pilot-safety control system.
MFR# DESCRIPTION WEBB#
785-001 Automatic Pilot Relight Kit 79497
785-001
5059-23
50E47-150
Pilot Relite Control
The relite control generates sparks until a pilot fame is sensed between the electrode and
ground. When fame current is sensed between the electrode and pilot burner ground,
the relite control stops sparking. If the fame is extinguished during the heat call, the relite
control will begin sparking the instant the fame goes out.
Ignition Module for Hot Surface Ignition Systems
The Hot Surface ignition Unit is a microprocessor based gas ignition control designed
primarily for direct ignition and burner supervision applications such as gas furnaces,
boilers, water heaters and other similar devices.
ELECTRICAL
MFR# INPUT VOLTAGE RATING DESCRIPTION WEBB#
5059-23 24 VAC 0.03 Amps Spark Plug and 1/4 Spade Connectors 118717
MFR#
LOCKOUT
TIME
IGNITOR
WARM-UP
TIME
50E47
PREPURGE
TIME
(IN SECONDS) WEBB#
50E41-843 4 Seconds 45 Seconds 0 Seconds 152586
50E47-140
7 Seconds
17 Seconds
30 Seconds
192971
50E47-150
45 Seconds
85263
50E47-170 0 Seconds 152586
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Ignition Modules
151
8
8
SECTION
Ignition Controls
G600, G670
G600/G760 ignition controls are reliable, proven circuitry replacements for G60, G67
controls. In most cases the replacement controls have mounting confgurations identical
to the original device. Replacement controls feature precision timing for lockout models.
Note: G600/G670 ignition control replacement parts must be used only for feld replacement of existing
equipment. These replacement parts must not be used for new feld applications.
Universal Replacement Intermittent
Pilot Ignition Control
G779
The G779 Universal Replacement Intermittent Pilot ignition Control replaces many existing
intermittent pilot controls made by various manufacturers. It is a safety control designed for
indirect burner ignition and supervision. The G779 can be used with all gas-fred appliances
with a maximum fring rate of 400,000 Btu/hr.
Applications
The G779 replaces existing intermittent pilot ignition controls with the following
specifcations:
Flame detection using fame rectifcation technology
(ability of a fame to conduct and rectify current).
Integral or remote fame sensing.
Non-100% lockout, 100% lockout, or 100% shutoff with continuous retry.
Trial for ignition period greater than or equal to 25 seconds.
Prepurge period less than 1 second.
Pilot burners with fow rates of 1,500 Btu-hr or less.
Operating with or without vent dampers.
The G779 is not designed to replace ignition controls with the following specifcations:
Pilot fame detection by any means other than fame rectifcation.
Trial for ignition period of less than 25 seconds.
Prepurge period greater than or equal to 1 second.
Standing pilot applications.
Specifcations
Operating voltage 24 VAC at 50/60 Hz
Ignition source High voltage spark, cap active discharge
Prepurge Less than one second
Number of trials before 100% shutoff One
Trial time for ignition 25 Seconds
Retry delay period 5 Minutes
Flame failure response time 0.8 Seconds
Type of gas Natural, Liquifed Petroleum (LP), manufactured,
mixed or LP gas-air mix
G779
G600
MFR#
100%
LOCKOUT
DAMPER
PLUG REMARKS WEBB#
G600AX-1C
No
Yes 24 VAC, Terminal Bard Wiring 97579
G670AW-1C No 24 VAC, 1/4 Spade Wiring Connections 105895
MFR# DESCRIPTION WEBB#
G779LHA-1C Universal Intermittent Pilot Ignition Control 110805
152
victormfg.com
Ignition Modules
8
Gas Equipment Catalog
SECTION
Spark Ignitor
Q347
Produces spark for direct ignition of main burner.
Includes inner Kanthal electrode with ceramic insulator,
bracket and Kanthal ground strap.
Use with S87C, D, K; S89E, F and Q354A.
Universal Intermittent Pilot Module
S8610U
Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC)
Intermittent Pilot Ignition Modules. Provides electronic control of most intermittent pilot
ignition systems used on gas-fred furnaces, boilers, and other heating appliances.
Provides ignition sequence, fame monitoring and safety shutoff for intermittent pilot
central furnaces and heating appliances.
Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for
ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or
call for heat is removed.
For use in single rod of dual rod/remote sense applications.
Includes relay contacts for use with any intermittent pilot has control string with
maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or
VR8345M combination gas control recommended.
Universal Hot Surface Ignition Module
S8910U
Provides operating control of a direct ignition system using a 120 Vac hot surface ignitor.
Provides easy feld-replacement of a wide range of hot surface ignition modules
manufactured by Honeywell, Robertshaw, and White-Rodgers. Refer to the product
specifcations sheet for specifc models that can be replaced by the S8910U.
For 120 VAC (up to 5.0A) hot surface igniter (Norton 201/271 or equivalent).
The S8910U can be used only for direct replacement of specifc installed models. Check
the product specifcation sheet before replacing an existing hot surface module with the
S8910U. If the existing module is not listed, do not use the S8910U to replace it. Always use
the selection tab specifed in the product specifcation sheet for the existing module being
replaced. Replacement of an unlisted module or use of a selection tab other than specifed
can result in appliance malfunction.
S8610U3009
S8910U1000
Q347
MFR# ROD ANGLE WEBB#
Q347A1004 Standard Orientation 188456
IGNITION LOCKOUT IGNITION TRIALS
MFR# DESCRIPTION TRIAL TIME TIMING TO LOCKOUT WEBB#
S8610U3009 Intermittent Pilot Control Continuous Retry 90 Sec. Max. Continuous Retry 74468
IGNITION LOCKOUT IGNITION TRIALS
MFR# DESCRIPTION TRIAL TIME TIMING TO LOCKOUT WEBB#
S8610U1000 Hot Surface Ignition Control 4 Sec. or 7 Sec. 4 Sec. or 7 Sec. 1 or 3 92054
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Ignition Modules
153
8
8
SECTION
Gas Ignition Modules
S89C Hot Surface Ignition Module
Provide electronic control of 120V hot surface ignition systems used in furnaces,
boilers and other heating appliances.
S89C is for systems with combination ignitor-sensor.
Use with Norton 201 Hot Surface Ignitors or equivalent.
Lockout after one trial for igniting if main burner fails to ignite.
Reset from thermostat after lockout.
Y8610U Universal Retrot Intermittent Pilot Gas Burner ignition Systems
Complete kits converting conventional standing pilot system to intermittent pilot system.
For use with 24 VAC gas-fred atmospheric furnaces, boiler and heating appliances.
Y8610U kits are for use with natural or LP gas; provides 100 percent pilot gas shutoff
if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
Ignition trial/delay sequence is repeated until the appliance lights or call for heat
is removed.
S9200U1000 Universal Hot Surface Ignition Integrated Furnace Control
Controls a standard induction-type circulating fan motor.
Main burner ignition using a 120V hot surface igniter.
Flame rectifcation circuit to monitor fame presence.
Monitoring of system pressure switch, high temperature limit, and rollout functions.
Appliance operation/safety requirements controlled via microprocessor.
Control of a standard induction-type circulating fan motor (based on appliance
requirements), in response to a conventional low voltage or EnviraCOM thermostat.
LED system status, performance and diagnostic indication.
Wire harnesses provided for simple replacement of most IFCs and integration with most
heating and cooling appliances.
Twinning capability
EnviraCOM communication capability to enable local and/or remote system status,
diagnostics, troubleshooting, and HVAC system control.
S89C
Y8610U
S9200U1000
MFR# LOCKOUT TIMING IGNITION TRIAL TIME WEBB#
S89C1087 6 Sec. 6 Sec. 95080
S89C1095 15 Sec. 15 Sec. 152200
MFR# IGNITION SEQUENCE TYPICAL GAS CONTROL GAS TYPE WEBB#
Y8610U3003
Continuous Retry
(after trial for ignition,
pilot gas shuts off for 5 minutes,
then another trial for
pilot ignition takes place)
VR8304M Dual Valve
Combination Gas Control
LP/Natural 74467
MFR#
AMBIENT
TEMP. (F)
PRE-
PURGE
HSI
WARMUP
TIME
POST-
PURGE
HEAT
ON FAN
DELAY
HEAT
OFF FAN
DELAY
COOL
FAN ON
DELAY
COOL
FAN OFF
DELAY
GAS CONTROL
USED WITH WEBB#
S9200U1000
40 F to
+175 F
30
seconds
17/27 or
30/30
seconds
15
seconds
30 or 60
seconds
60, 90,
120, or 180
seconds
5 seconds
0 or 60
seconds
Any 24 VAC
redundant, direct
ignition gas control
rated at 1.5A or less.
Honeywell VR8205
recommended.
372843
154
victormfg.com
Gas Valves
8
SECTION
Gas Equipment Catalog
Water Heating
Domestic, Commercial & Recreational Vehicle Water Heater Thermostat Uni-Kits
110 Series
The 110-Series Water Heater Thermostat Uni-Kit
The Uni-Line 712 series pilot ignition system features fame rectifcation with solid-state
logic and fame sensing to provide automatic sequencing that will ensure proper operation
of an intermittent pilot ignition device. The 712 series pilot ignition system features quick
and easy installation with complete in-depth instructions and trouble shooting information.
Uni-Kit
4200
Cycle-Pilot
Retrot Kit
Control system designed to eliminate standing pilots by converting to cyclepilot
controls with automatic spark ignition. Gas valve functions are terminated on a
printed circuit board that exits through the mercury fame sensor receptacle housing,
on the terminal panel side.
Features
Eliminates gas wasted by a standing pilot.
Eliminates pilot outage problems due to occasional drafts.
Each package contains the controls and hardware needed for conversion to
cycling pilot operation.
Uses existing pilot burner and wiring.
21D18-3
Packages Available
Specifcations
MFR#
GAS
VALVE
IGNITION
UNIT DESCRIPTION WEBB#
Nonlockout Models Caution: Do not use on LP. Gas Applications
712-016
700-055
3/4 X 3/4
780-715
(Nonlockout)
Natural Gas Only Nonlockout Pressure regulator is
factory-set at 3.5 W.C. 350,000 Btu Max
189792
MFR#
BODY
TYPE
INLET
SIDE
F
INLET
REAR
H
OUTLET
SIDE
E
OUTLET
SIDE
G
PILOT
OUTLET
CAPILLARY
LENGTH
MOUNTING
POSITION
BULB
SIZE WEBB#
150 to 550 F (Degrees)
4200-025
Uni-IGI
#2
3/8
Pipe
3/8
Pipe
3/8
Pipe
3/8
Pipe
Side &
Rear
54 4-Way
3/16
Nickel
Low (200 F) to 550 F (Degrees)
4200-026
Uni-IGI
#2
3/8
Pipe
3/8
Pipe
3/8
Pipe
3/8
Pipe
Side &
Rear
54 4-Way
3/16 x
143/4
Nickel
186688
MFR#
INLET
SIZE
(FPT)
INLET/
OUTLET
SIZE PILOT
CAPILLARY
LENGTH
MOUNTING
POSITION BULB SIZE WEBB#
4200-005 #2 1/2 Pipe Side 48 4-Way 3/16 X 143/4 Nickel 186685
MFR#
COIL
VOLTAGE
60 Hz
ELECTRICAL
RATING
INLET/
OUTLET
SIZE
CAPACITY
A.G.A.
STANDARD GAS GAS TYPE WEBB#
21D18-3 24 VAC 0.61 amps 3/4 X 3/4 280,000 Natural Only 188186
MFR#
GAS
VALVES
FLAME
SENSOR
ELECTRODE
ASSEMBLY
PILOT
RELIGHT
WIRING
HARNESS
21D18-3 38C84-426 3098-134 760-56 5059-23 F115-0084
160
victormfg.com
Gas Valves
8
SECTION
Gas Equipment Catalog
SmartValve System
SV9501
Combines gas fow control and electronic intermittent pilot sequencing functions into
a single unit.
Suitable for a wide range of gas-fred appliances including residential furnaces,
roof-top furnaces, residential boilers, unit heaters, infrared heaters, space heaters and
commercial cooking units
Replaces SV9500, SV9501 and SV9502 control. See installation instructions for
specifc models. Ignition sequence includes timed trial for ignition.
Accessories
SV9501
Gas Valves,Electronic Single Stage
Standing Pilot
V800 Low Voltage Combination Gas Controls
Provide complete control of continuous pilot gas-fred central furnaces and boilers.
Include pilot fow adjustment screw.
Complete safety shutoff on pilot fame failure.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
VR8200 Continuous Pilot Dual Automatic Valve Combination Gas Controls
Combination gas controls for use in 24 VAC gas-fred, standing pilot appliances with
capacities from 20 to 200 cfh.
Controls include manual valve, two automatic operators, servo pressure regulator
and pilot adjustment.
Compact size.
Provide two automatic valves.
Solenoid-operated frst automatic valve opens on thermostat call for heat; closes
when call for heat ends. Diaphragm-operated second automatic valve opens under
control of regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available. LITE-RITE (OFF-PILOT-ON)
lighting sequence.
All adjustments, wiring connections and pilot outlet are accessible from top of control.
Adjustable servo regulator effectively maintains almost constant gas output pressure
under wide fuctuations in gas supply pressure.
Compatible with ECO connector.
V800
VR8200
MFR# SIZE
TEMPERATURE
RATINGS
PRESSURE
REGULATOR
SETTING
PRE-
PURGE
OPENING
CHARACTERISTICS WEBB#
SV9501M2528 1/2 -40 F To 175 F 3.5 W.C. None Standard Opening 210277
SV9502H2522 1/2 -40 F To 175 F 3.2 W.C. 15 Sec. Slow Opening 214000
SV9602P4816 3/4 -40 F To 175 F 3.5 W.C. 30 Sec. Step Opening 424578
MFR#
TYPE OF
GAS
PRESSURE
REGULATOR
SETTING
INLET/
OUTLET
SIZE INCLUDES WEBB#
V800A1070
Natural
Or LP
3.5 W.C.
3/4 X 3/4
One 3/4 X 1/2 Reducer
Bushings/Adapters
35054
V800A1088 1/2 X 3/4
Two 3/4 X 1/2, One 1/2 X 3/8
Reducer Bushings/Adapters
35055
MFR#
TYPE
OF GAS
PRESSURE
REGULATOR
SETTING
INLET/OUTLET
SIZE
OPENING
CHARACTERISTICS INCLUDES WEBB#
VR8200A2132 Natural 3.5 W.C. 1/2 X 1/2 Standard
1/2 X 3/8 Reducer Bushings;
38389014 bag assembly - 3/4 straight
flange with O ring screws and wrench;
and 393891 Natural to LP Gas
Conversion Kit
68950
Q3400A1024 Ignitors 154343
39369 Natural to LP Conversion Kit 184601
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Gas Valves
161
8
SECTION
8
Gas Valves, Electronic Single Stage
Intermittent Pilot
VR8204 Intermittent Pilot Dual Automatic Valve Combination Gas Controls
Combination gas control for use in 24 VAC gas-fred intermitent pilot appliances with
capacities from 20 to 200 cfh.
Controls include manual valve, two automatic operators, servo pressure regulator
and pilot adjustment.
Use with S86F,H; S8600F,H and S8610 Control Modules.
Compact size.
Provide two automatic valves.
Solenoid-operated frst automatic valve opens on thermostat call for heat;
closes when call for heat ends. Diaphragm-operated second automatic valve opens
under control of regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available.
All adjustments, wiring connections and pilot outlet are accessible from top of control.
ON-OFF lighting sequence.
VR8204
Gas Valves, Electronic Single Stage
Standing Pilot
VR8300 Continuous Pilot Dual Automatic Valve Combination Gas Control
Combination gas control for use in 24 VAC gas-fred standing pilot appliances
with capacities from 30 to 300 cfh.
Controls include safety shutoff, manual valve, two automatic operators,
pressure regulator and pilot adjustment.
Compact size.
Provide two automatic valves.
Solenoid-operated frst automatic valve opens on thermostat call for heat; closes
when call for heat ends. Diaphragm-operated second automatic valve opens under
control of regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Standard and slow opening natural gas models include natural to LP gas conversion
kit; LP to natural gas conversion kit also available.
All adjustments, wiring connections and pilot outlet are accessible from top of control.
Adjustable servo regulator effectively maintains almost constant gas output
pressure under wide fuctuations in gas supply pressure.
Compatible with ECO connector.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
VR8300
MFR#
TEMPERATURE
RATINGS
PRESSURE
REGULATOR
SETTING
INLET/
OUTLET
SIZE
OPENING
CHARACTER-
ISTICS INCLUDES WEBB#
VR8204A2076 -18 F to +79 F 3.5 W.C. 1/2 X 1/2 Standard
3/4 X 3/8 Reducer
Bushing 393691
Natural to LP Gas
Conversion Kit
76221
MFR#
PRESSURE
REGULATOR
SETTING
INLET/
OUTLET
SIZE INCLUDES WEBB#
VR8300A4516 3.5 W.C. 3/4 X 3/4
Two 3/4 X 1/2 Reducer Bushings; 383200EOO adapter,
Q340 (36) thermocouple with adapters,
393691 Natural to LP Gas Conversion Kit
86743
162
victormfg.com
Gas Valves
8
SECTION
Gas Equipment Catalog
Gas Valves, Electronic Single Stage
Direct Ignition
VR8345 Universal Electronic Ignition Combination Gas Control
Universal electronic ignition combination gas control for use with direct spark ignition, hot
surface ignition or intermittent pilot ignition in 24 VAC, gas-fred appliances, with capacities
from 30 to 415 cfh.
Control includes manual valve, two automatic operators, pressure regular,
pilot adjustment, pilot plug and ignition adapter.
Replaces virtually any IP, HSI, or DSI gas control.
For use with natural or manufactured gas or LP gas. Includes converter kit to adapt
from natural to LP gas.
Compact size.
All adjustments and wiring connections accessible from top of control.
Four-inch swing radius allows easy rotation into position inside the tightest
furnace vestibules.
Clearly marked, keyed terminal block allows quick attachment of wires and IP/DSI/
HSI jumper.
Internal inlet screen blocks contaminants in gas line from entering valve.
VR8345
VS830
Gas Valves, Millivolt
VS830 Millivoltage Combination Gas Controls
Provide complete control of continuous pilot gas-fred central furnaces and boilers.
Include pilot fow adjustment screw.
Easy to install, adjust and service; all adjustments and connections are accessible
from top of control.
Add separate energy cutoff (ECO) where codes call for dual safety shutoff.
Complete safety shutoff on pilot fame failure.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
ECO connector for V800 models. Part No. 392451-1.
MFR#
INLET/
OUTLET
SIZE
PRESSURE
REGULATOR
SETTING
TYPE
OF GAS INCLUDES WEBB#
VR8345M4302 3/4 X 3/4 3.5 W.C. Natural
Two 3/4 X 1/2 NPT Reducer Bush-
ings and one 1/2 X 3/4 NPT Bushing
93587
MFR# INLET/OUTLET SIZE
PRESSURE
REGULATOR SETTING TYPE OF GAS WEBB#
VR820A1047 1/2 X 3/4
3.5 W.C. Natural
35056
VR820A1054 3/4 X 3/4 35057
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Thermocouple & Thermopile Generators
163
8
SECTION
8
Thermocouples and Pilots
1950 & 1951 Thermopiles
The 1950 and 1951 Thermopiles (pilot
generators) are designed for use on
self-positioned gas control systems.
1970 Uni-Couples 20 to 30 Millivolts
The 1970 Series Uni-Couples unique design allows for
installation to virtually all pilot burners. The versatile zip
nut may be pushed, pulled or threaded onto the thermo-
couples rolled threads for proper positioning in every
application. The stainless steel tip (longer life), extended
cold junction (greater voltage output potential), copper tube
(corrosion protection with low electrical resistance), and
lock washer equipped coaxial connection (resists loosening
due to vibration or changes in ambient temperature) make
the Uni-Couple the single most versatile thermocouple
available today.
1980 Snap-Fit Thermocouples
The 1980 Series Snap-Fit Thermocouples offer easy
installation into the majority of pilot burners. Both slim and
standard thermocouple types are available in the 1980 Series
without complicated adapters, but with the extra insulation
from high ambient temperatures that the brass sheath offers
when needed. The 1980 is constructed of the same materials
as used in the 1970.
1960-027 Low Mass Thermocouple
The 1960-027 is a special low-mass or quick dropout
thermocouple. It is usually found on applications that
require an oxygen depletion system on the thermo safety.
Also found on many L.P. gas applications that require a
quick dropout of the thermo safety if there is a loss of
pilot fame.
Note: Has standard thermocouple threads.
Will not ft applications with metric threads.
Replacement Parts
Thermocouple Test Adapter
Adapter to test thermocouple and thermopile closed circuit.
Shank Extension
Increases length of 11/4 and 13/8 shank models to
approximately 3.
Junction Block Adapter
The 1922-001 adapter allows the high limit switch to be
connected into the thermocouple cicuit on valves without
the slotted magnet.
MFR# DESCRIPTION WEBB#
10-238 Thermocouple Test Adapter 167043
MFR# LENGTH WEBB#
1970-018 18 167188
1970-024 24 167189
1970-030 30 167190
1970-036 36 85375
1970-048 48 155170
1970-060 60 186644
1970-072 72 85441
MFR# LENGTH WEBB#
1960-027 27 217093
MFR# LENGTH WEBB#
1980-018 18 73470
1980-024 24 73471
1980-030 30 186645
1980-036 36 73472
1980-048 48 152596
1980-060 60 73473
1980-072 72 188181
MFR# DESCRIPTION WEBB#
10-250 Shank Extension 80696
MFR# DESCRIPTION WEBB#
1922-001 Junction Box Adapter 75109
Y99AN-1H Junction Block Adapter 178174
1950-001
1950-002
1950-003
1950-532
1950-548
1951-001
1951-536
MFR# LENGTH
INCLUDES PG9
PILOT ADAPTER
CONNECTION
TYPE WEBB#
36
48
60
36
48
36
36
82642
194065
186640
192848
186641
73469
111602
Two Lead
Coaxial
Y99AN-1H
1922-001
164
victormfg.com
Thermocouples & Thermopile Generators
8
SECTION
Gas Equipment Catalog
Replacement
Thermopile Generators
Q313
Provide power for millivoltage,
self-powered control systems.
Eliminate the need for outside
power source.
Easy push-in installation.
Include spade terminals.
Individually skin packed,
each unit ordered represents
one thermopile generator.
Universal
30 mV Thermocouple
Q340
There is a Q340 for every gas-fred heating system application.
Replace almost any 30 mV thermocouple.
Average operating life of ten years.
Available in a variety of lead lengths.
Q340A1066
Q340A1074
Q340A1082
Q340A1090
Q340A1108
MFR# LENGTH (IN) WEBB#
18
24
30
36
48
30876
30877
30878
30879
86216
K19AT-18H
K19AT-24H
K19AT-30H
K19AT-36H
K19AT-48H
K19AT-60H
MFR# LENGTH (IN) TYPE WEBB#
18
24
30
36
48
60
183569
183570
183571
152513
155142
183574
Super Slim Jim
Standard BASO
Thermocouple
K15 Series
The K15 Series Thermocouples are designed for
use in standing pilot ignition systems. They are used
primarily with BASO brand automatic pilot controls
and pilot burners.
K15DS models are standard thermocouples. K15FS models
are snap-on thermocouples that allow for fast, easy
assembly. The K15WS model is a wholesale thermocouple
that is supplied with additional fttings.
Husky High Performance
Thermocouple
K16 Series
The K16 Series are heavy-duty,
high performance thermocouples
that provide high output for
residential, commercial, and
industrial applications. The
Husky is a replacement
for BASO 17D, 50, 58D, 87D,
88D, 97D, 107D, and K15DA
thermocouples. The K16 is packed with adapters to
allow the necessary replacement. K16BT models are
standard thermocouples. K16RA models are nickel
plated thermocouples. K16WT models are wholesale
thermocouples that are supplied with additional fttings.
K16BT-18H
K16BT-24H
K16BT-30H
K16BT-36H
K16RA-60C
K16WT-48H
MFR# LENGTH (IN) TYPE WEBB#
18
24
30
36
60
48
183564
152511
183565
96960
194088
183568
Husky
Husky Nickel Plated
Husky With Fittings
K15DS-18H
K15DS-24H
K15DS-30H
K15DS-36H
K15FS-24H
K15FS-36H
K15WS-48H
MFR# LENGTH(IN) TYPE WEBB#
18
24
30
36
24
36
48
184577
183556
183557
184579
183561
183562
183563
Standard BASO
Snap in BASO
Standard BASO With Fittings
MFR# RESISTANCE INCLUDES
LEAD
LENGTH WEBB#
1/2 thermopile
attaching nut
Push-in clip
PG9 adapter
(part #393948)
Push-in clip,
1/2 thermopile
attaching nut
Includes junction
box for series
hook up with high
limit switch
Q313A1055 47 2.90 ohm 188174
Q313A1139 83335
Q313A1170 85874
Q313A1188 35 2.89 ohm 84659
Q313B1005 86741
Super Slim Jim
Universal
Replacement
Thermocouples
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Pilot Burner & Orifces
165
8
SECTION
8
Gauging Drill Kit GDK4080
Plastic box contains 41 drill sizes: #40 80, and GB3020H tapered broach.
Anderson & Forrester Inc.
MFR# DESCRIPTION WEBB#
ANFGDK4080 Gauging Drill Kit 188739
Tapered Broach GB3015
Three cornered broach. Tapered from .003 to .013. A must for cleaning Pilot Orifces.
MFR# DESCRIPTION WEBB#
ANFGB3015 Three Cornered Broach 180504
Master Pilot Orice Assortment Kit MIK132LP
In one kit you now have 32 of the most needed pilot orifces with over 100 pieces. These
are replacement pilot orifces for Penn Baso, Robertshaw, General Controls, Honeywell
and White-Rodgers. A must for every effcient serviceman. Cabinet is made of heavy gauge
steel with durable baked enamel fnish and radius bottom sections for easy removal.
MFR# DESCRIPTION WEBB#
ANFMI132LP Pilot Orifce Assortment Kit 180534
Master Adapter Kit MIK100
Includes all tools needed to assemble MI100 adapters.
MFR# DESCRIPTION WEBB#
ANFMIK100 Master Adapter Kit 180533
ANFMI100 Universal Adapter 180532
Servicemans Friend TL051
For use with fow meter and other applications. One end of ftting has 1/8 pipe thread,
1/4 pipe thread and special 5/16 X 32 thread. Opposite end has regular hose ftting, also
1/8 straight pipe thread. Hose can be used on either end.
Gauging Reamer Kit GRK5000
Have the correct size reamer when you need it. Our kit contains each size in a slim
plastic case.
MFR# DESCRIPTION WEBB#
ANFGRK5000 Gauging Reamer Kit 180593
ANFGR5070 Gauging Reamer, #70, 5 Pack 180602
ANFGR5080 Gauging Reamer, #80 180598
Servicemans Orice Assortment Kit MIK131LP
The MIK131 orifce cabinet contains 23 of those orifces most commonly used.
Over 300 orifces in proportion to normal demand.
MFR# DESCRIPTION WEBB#
ANFTL051 Servicemans Friend 180578
MFR# DESCRIPTION WEBB#
ANFMIK131LP Orifce Assortment 188738
Gauging Drill Kit
Tapered Broach
Gauging Reamer Kit
Master Adapter Kit
Master Orice Kit
Servicemans Orice Kit
Servicemans Friend
166
victormfg.com
Pilot Burner & Orifces
8
SECTION
Gas Equipment Catalog
Compression Fittings
Break-away type separates upon tightening.
MFR# DESCRIPTION WEBB#
ANFCF639 1/8 Short Breakaway Nut 180414
ANFCF640 3/16 Short Breakaway Nut 180415
ANFCF641 1/4 Short Breakaway Nut 180388
HON386449-1 1/4 Breakaway Nut 102371
ANFCF642 1/4 Medium Breakaway Nut 180599
EMPR1633-2 1/8 Long Breakaway Nut 181653
HON386449-4 1/4 Long Breakaway Nut 223431
EMPR2972 1/4 Long Breakaway Nut 181654
EMPR1633-4-2 1/4 X 1/8 Long Breakaway Nut 181653
RBS4590-065 1/8 Short Breakaway Nut 93031
RBS4590-067 3/16 Short Breakaway Nut 93030
RBS4590-069 1/4 Short Breakaway Nut 93028
RBS4590-071 3/8 Short Breakaway Nut 186719
RBS4590-072 7/16 Short Breakaway Nut 189070
Anderson & Forrester Inc.
Gas Orifces &
Gauging Drills
(continued)
Orice Caps
MFR# DESCRIPTION WEBB#
ANFCO400-72 LP, 1/2 Hex, 3/8-40 UNS 180416
ANFCO401 Blank, 1/2 Hex, 1/2-27 NPT 180419
ANFCO403 Bored, 1/2 Hex, 3/8-27 UNS 180421
ANFCO404 Blank, 9/16 Hex, 1/2-27 UNS 180422
ANFCO406 Blank, 1/2 Hex, 3/8-27 UNS 180424
Orice Hex Plugs
MFR# DESCRIPTION WEBB#
ANFPO505 Blank, 1/2 Hex, 1/8-27 NPT 180541
ANFPO508 Blank, 1/4 Hex, 1/4-28 UNF 180544
ANFPO511 Blank, 1/2 Hex, 7/16-27 UNS 180546
ANFPO518 Blank, 3/8 Round, 11/32-32 Special 180549
MFR# GAS TYPE TUBE SIZE ORIFICE SIZE WEBB#
10-030 LP 1/4 or 3/16 .010 186598
10-261 LP 1/4 .0088 186605
PILOT GAS TUBE ORIFICE
MFR# USAGE TYPE SIZE SIZE WEBB#
10-066 #70 & #71 Nat. 3/16 .018
10-043 #70 & #71 Nat. & L.P. 3/16 .014 85387
10-045 #40A L.P. 3/16 .013 186600
Replacement
Parts &
Accessories
Pilot Orifces
Pilot Tube
Just bend and cut to length! Keep a few on your truck to
take care of clogged pilots! 3/16 pilot tube, 17 long with
4 port orifce hood.
MFR# DESCRIPTION WEBB#
10-383 3/16 X 17 Pilot Tube 189026
Aluminum Tubing
A full range of diameter sizes in 50 lengths,
and for convenience, 5 lengths with fttings.
MFR# O.D. SIZE LENGTH WEBB#
11-016 7/16 5 94204
11-017 3/8 5 155172
11-191 1/8 50 153380
11-193 1/4 50 155171
11-195 3/8 50 155173
11-291 1/8 5 212789
11-292 3/16 5 73442
11-293 1/4 5 73443
10-043
10-045
10-066
10-028 10-261
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
G
A
S
H
E
A
T
I
N
G
Pilot Burner & Orifces
167
8
SECTION
8
Pilot Burner
Q314
Nonprimary-aerated, insert orifce type pilot burner for main burner ignition with
Q340 or Q390 Thermocouple for Pilotstat safety control operation.
Use with Q313 Thermopile Generator for 750 mV powerpile applications.
Q314
Q327
Primary-aerated, spud orifce-type pilot burner for main burner ignition with
Q340 or Q390 Thermocouple for Pilotstat safety control operation.
Use with Q313 Thermopile Generator for 750 mV powerpile applications.
Q345
Nonprimary-aerated, combination pilot burner and ignitor. Used with the S86, S8610,
or S8670 in intermittent pilot systems.
Includes pilot burner with bracket, ceramic-insulated Kanthal fame
rod/spark ignitor and ground strap.
Q345A
Q347
Combination Type Pilot Burner
The J991MDA-2 through J999MDA-2 models are universal replacement pilot burners
for J10(-)DDA, J11(-)DDA (D10and D11) types.
The pilot burners are individually packaged in a plastic bag. 10 bags per carton.
Multi-Mount Universal Pilot Burner
The J Series BASO universal replacement pilot burners are supplied in three models.
Mounting brackets on all four sides of each burner permit adaptation to almost
any application.
The pilot burners are individually packed in a plastic bag. 10 bags per carton.
Three tapped holes in each bracket for vertical adjustment.
Natural and LP gas orifce supplied.
Nuts and bolts furnished in each package.
#2
#7
#8 #9
J999MHA-2 J999MKA-2
J999MYA-2
Q314A4586
Q314A6094
Q314A4585
LP; Natural B
Front
Left
Right
MFR# TYPE OF GAS
MOUNTING
BRACKET
DIRECTION OF
FRONT TIP WEBB#
80635
86742
Q345A1305
Q345A1313
MFR# DIRECTION OF FRONT TIP TYPE OF GAS WEBB#
Front
Left
Natural
152195
152196
J992MDA-2H
J997MDA-2H
J998MDA-2H
J999MDA-2H
MFR# TIP POSITION NATURAL GAS ORIFICE LP GAS ORIFICE WEBB#
2
7
8
9
Y90AA-3223
Y90AA-3221
Y90AA-3223
Y90AA-3223
Y90AA-4213
Y90AA-4211
Y90AA-4212
Y90AA-4212
183617
118696
118697
183554
J999MHA-2H
J999MKA-2H
J999MYA-211
MFR# TYPE OF PILOT NATURAL GAS ORIFICE LP GAS ORIFICE WEBB#
L Channel
Shell
Y Channel
Y90AA-7223
Y90AA-7221
Y90AA-6221
Y90AA-4211
Y90AA-4210
Y90AA-4211
118699
183620
MFR# DESCRIPTION TYPE OF GAS WEBB#
Q327A1626 Bat Wing LP; Natural 88371
168
victormfg.com
Pilot Burner & Orifces
8
SECTION
Gas Equipment Catalog
Gas Ignition Controls
Replacement Sensors
MFR# DESCRIPTION WEBB#
10-277 S1 Sensor has 1/4 quick-connect terminal 203364
Pilot Kits
1810-100 Universal 2BLC Pilot Uni-Kit
125
45.7
50
15.2
PBGMB 24-23-24
21
533.4
15.5
393.7
10.5
266.7
20.5
520.7
22.75
577.9
29.25
743.0
28.25
717.6
28.25
717.6
150
45.7
75
22.9
PBGMB 30-23-24
27.5
698.5
22
558.8
10.5
266.7
20.5
520.7
22.75
577.9
35.75
908.1
34.75
882.7
34.75
882.7
200
61.0
110
33.5
PBGMB 28-25-26
27.5
698.5
22
558.8
10.5
266.7
25.5
647.7
24.75
628.7
33.75
857.3
32.75
831.9
32.75
831.9
Specifcations subject to change.
176
victormfg.com
Pump Accessories
9
SECTION
Gas Equipment Catalog
Victor/F.w. Webb stocks
siemens generators.
Power Rewind Reels with
Bottom-Mounted Guidemaster (continued)
Notes:
1. Upon request, reels can be supplied with drum lengths other than shown and with disc sizes in
other diameters.
2. When ordering power rewind models, prefx model number with:
A = Air Rewind Supplied with control valve and hose.
E = Explosion Proof Electric Rewind (1/2 HP) Supplied with explosion proof switch, solenoid and
junction box.
HD = Hydraulic Rewind Not supplied with control valve.
3. Dimension J is maximum, with fully extended Guidemaster in operating position. Dimension K is
maximum, with fully extended Guidemaster in traveling position opposite rewind motor, as shown
in dimensional drawing. Dimension L is maximum, with fully extended Guidemaster in travelling
position on same side as rewind motor. (The telescoping feature of the Guidemaster permits each of
these dimensions to be reduced up to 4.) Maximum distance from frame of reel to outside edge of
Guidemaster locked in traveling position is 11.
HOSE CAPACITY
OF REEL FEET (M) MFR# REEL DIMENSIONS INCHES (MM)
APPROX
WEIGHT LB.
KG.
WEBB#
I.D. (IN)
I.D. (MM)
1
25.4
11/2
38.1
FOR POWER REWIND
SEE NOTE 2
G H J K L NET SHIP
O.D. (IN)
O.D. (MM)
1.5
38.1
2.16
54.8
125
45.7
50
15.2
PBGMB 24-23-24
23.5
596.9
12.12
307.8
51
1295.4
39.75
1009.7
33
838.2
160
73
185
84
150
45.7
75
22.9
PBGMB 30-23-24
23.5
596.9
12.12
307.8
51
1295.4
43
1092.2
35.25
920.8
170
77
200
91
200
61.0
110
33.5
PBGMB 28-25-26
27.88
708.2
15.5
393.7
52
1320.8
42
1066.8
35.25
895.4
173
78
203
92
Specifcations subject to change.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pump Accessories
177
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
FLEX HOSE
Flex Connectors
MFR# SIZE WEBB#
FLES50-12 1/2 X 12 187507
FLES75-12 3/4 X 12 187508
FLES100-12 1 X 12 187500
FLES125-12 11/4 X 12 187501
FLES125-18 11/4 X 18 187502
FLES150-12 11/2 X 12 187503
FLES200-14 2 X 14 187505
FLES300-24 3 X 24 187506
Self-Cleaning Strainers
Style B 112, 600#, Threaded, Ductile Iron
SC000B112AD
Style C 103, 600#, Threaded with Bolted Cover,
Ductile Iron
SC000C103AD
Style A 105, 300#, Flanged, Ductile Iron
SC000C103AD
Applications:
General purpose Stainless Steel double braided metal
fexible gas hose assemblies code rated @ 350 psi available
with NPT, ASME fanges, and pipe weld ends. For use
typically as a vibration dampener/fexible connector
1/2 4 sizes on pump, compressor, and generators.
Also available UL536 listed Metal Hose Assemblies suited
for Natural Flammable and Combustible Liquid and Gas
Service @ 175 psi.
All fexible connectors pictured have schedule 80 NPT
threaded end with a corrugated stainless hose covered with
a double braided stainless steel assembly cover.
LP Gas Flowmeter
MFR# DESCRIPTION SIZE WEBB#
LIQLPM102 1 Gal. Register 3/4 182604
2
Internationally recognized for our
superior fowmeter replacement parts,
Liqua-Tech now offers the Model
LPM-102 LP Gasliquid fowmeter.
Designed for retail sales dispensing
units, the LPM-102 offers the widest
fow range, (3-18 gpm) available
in a meter of this type. In
addition, the LPM-102 contains
all required accessories including
vapor eliminator, strainer and
differential valve.
Other sizes can be custom made.
MFR# SIZE WEIGHT WEBB#
SCSB112AD-34 3/4 21/2 lbs. 184112
SCSB112AD-1 1 41/2 lbs. 261609
SCSB112AD-114 11/4 7 lbs. 184114
SCSB112AD-112 11/2 8 lbs. 184115
SCSB112AD-2 2 15 lbs. 193217
MFR# SIZE WEIGHT WEBB#
2 20 lbs.
SCB112AD-3 3 41 lbs. 202666
4 100 lbs.
MFR# SIZE WEIGHT WEBB#
2 39 lbs.
SCSSC0300A105AD 3 65 lbs. S497139
SCSSC0400A105AD 4 130 lbs. S497138
178
victormfg.com
Pump Accessories
9
SECTION
Gas Equipment Catalog
Swivel Connectors
Full-Circle offers a complete line of swivel connectors designed for use with thin to viscous
liquids and liquefed gases.
Straight-through hose end swivels allow the fller valve to rotate 360. This enables the
driver to make tank connections without fghting the hose. It also prevents hose twisting
upon reel-up.
For bulk-head use, the 90 swivel allows for the use of a shorter transfer hose and enables
the operator to safely sweep the hose to one side for proper, out of the way storage.
The design is ideally suited for hose reel use as the sealed high load ball bearing can
tolerate misalignment problems that could cause product leakage in other swivel types.
The tri-directional movement of the three-piece seal package continually compensates
for eccentric movement.
The Zero maintenance design is of critical importance, especially for leading/unloading
arms that must be constructed high in the air for railroad tankcar transfer operation.
Safety First All swivels produced by Full-Circle for LP-gas, ammonia, and fammable liquids
are listed by the Underwriters Laboratories and are designed and tested in accordance with
the U.L.-567 standard, your assurance that the product has been tested to a standard of
safety.
No Maintenance Design All Full-Circle swivels unitize a sealed high load ball bearing.
No greasing or lubrication is ever required.
No Rotating Rubber Seals All full-circle swivels incorporate the superseal mechanical
seal. This patented design allows the seal ring to foat between two metallic seals. While
in operation, the seal ring rotates at one-half the swivel rotational speed. The tri-directional
movement of the seal components allows for continuous adjustment due to vibration,
misalignment, and temperature extremes. Upon depressurization, the seal spring maintains
a constant force on the seal package, preventing product leakage in zero to low pressure
environments.
Misalignment Minimized All Full-Circle swivels utilize a radial contact ball bearing
with extremely high load ratings. The bearing is sealed for life and requires no periodic
lubrication. The ball bearing completely supports the rotating portion of the swivel to
ensure smooth and easy movement.
Field Replacement Components All full-circle swivels are designed so that replacement
parts can be installed simply and easily in the feld with no special tools required.
Additional Notes
Temperature range:
-40F to + 350F
Hydrostatic test pressure:
2000 psi for ammonia swivels,
1750 psi for other liquid/
liquefed gases
Maximum working pressure:
400 psi for ammonia swivels, 350
psi for other liquid/liquefed gases
Maximum rotatinal speed:
1000 RPM
Maximum load on ball bearing at
33 RPM:
5000 lbs for 11/2 and 2 swivels,
2000 lbs for other SMAC prefx
swivels, and 1000 lbs for JO prefx
swivels
U.L. Standard:
567
SMAC-112LN; 11/2 FNPT 90 Swivel
90 Type
Straight Through Type
Straight-Through Hose End
Filler Valve Type
Straight Through Type Same thread size for inlet and outlet
90 Type Same thread size for inlet and outlet
Straight Through Hose-End Filler Valve Type Allows fller valve to rotate 360
MFR# SIZE THREADS A B WEIGHT WEBB#
SMAC-3490LN 3/4 X 3/4
Female NPT
3 45/8 63/4 lbs. 283972 SMAC-190LN 1 X 1
SMAC-114LN 11/4 X 11/4
SMAC-112LN 11/2 X 11/2
31/4 43/4 131/8 lbs. 309126
SMAC-200LN 2 X 2
MFR# SIZE THREADS A B WEIGHT WEBB#
SMAC-34STLN 3/4 X 3/4
Female NPT
51/4 31/16 41/2 lbs. SMAC-1STLN 1 X 1
SMAC-114STLN 11/4 X 11/4
SMAC-112STLN 11/2 X 11/2
511/16 47/8 113/4 lbs.
SMAC-200STLN 2 X 2
MFR# SIZE THREADS A B WEIGHT WEBB#
JO-1LN 1 X 1 Female X Male 33/8 21/2 11/2 lbs. 246584
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pump Accessories
179
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Krug Compressor
MFR# DESCRIPTION WEBB#
KRUH50LP Transfer Compressor, LP Engine 182405
KRUH50G Transfer Compressor, Gas Engine 182404
QTY MFR# DESCRIPTION WEBB#
Liquid Transfer Hose
30 HOS3/4 3/4 LP Hose 185604
2 HOSHY12-12MP 3/4 Hydraulic Coupling, 2 pieces in kit 185576
Compressor Inlet Hose (Bobtail to Compressor)
12 HOS1/2 1/2 LP Hose 185581
2 HOS7661-08MP08TY 1/2 Hydraulic Coupling 193208
Compressor Outlet Hose (Compressor to Tank to be Evacuated)
25 HOS1/2 1/2 LP Hose 185581
2 HOS7661-08MP08TY 1/2 Hydraulic Coupling 193208
Fittings
1 RGO3175 3/4 Hose Coupling 162687
1 F/S34CO3SE 3/4 Hose Coupling, 3M 8735
1 RGO7550P 3/4 Transfer Angle Valve 162760
1 RGO3165CP 1/4 Bleeder Valve* 186852
1 RGO7590U-10 3/4 Check Lock Adapter* 162762
1 RGO3175B 1/2 Hose Coupling 186853
1 RGO3171A 1/2 Vapor Coupling 162686
2 JOM100-703 1/2 Ball Valve 151448
Basic Hose Kit
*Install in 7550P for new style Checklok
180
victormfg.com
Pump Station Kits
9
SECTION
Gas Equipment Catalog
Pump Station Without Meter
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pump Station Kits
181
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Pump Station Without Meter (continued)
Pump Station Schematic Drawing Key No Meter
DRAWING QTY ALPHA CODE DESCRIPTION WEBB#
1 1 G/T1000AG 1000 Gal. Above Ground LP Tank 185224
1 1 G/T500AG-B 500 Gal. Above Ground LP Tank 215818
2 (A,B,C) 1 VCTTANKST Victor Tank Stands, Pump Mount, and Meter Mount 184438
3 42 D/P114BPE 11/4 X 21 sch40 black pipe price per foot. Use 2 full lengths each leg for 1000 gal., cut 2 to 16 for 500 gal. 45533
4 Checklok Emergency Liquid Evacuation Valve (Possible Rego 7590U)
5 POL Service/Vapor Evacuation Valve (Possible Rego 7556R12.0)
6 Double Check Filler Valve (Possible Rego 7579)
7 1 RGOA8017DP Bottom Tank Valve Liquid Service 11/4 X 1 162493
8,9 1 CRKC12SMB Corken Pump C12SMB 11/2 Pnlet 1 Putlet 1 HP Motor With Switch Mounted On Motor And B166 Bypass 181039
10 1 NIPCS114X1XH 11/4 X 1 Concentric Swedge Nipple XH 187220
11 2 F/S114903SE 11/4 90 Elbow 3000# Forged Steel Threaded 8693
12 1 NIP114X10XH 11/4 X 10 XH Black Nipple 187212
13 1 SCSB112AD-114 11/4 Ductile Iron Strainer Threaded 184114
14 1 F/S34PL 3/4 Plug 3000# Forged Steel Square Head Threaded 8831
15 1 NIP114X8XH 11/4 X 8 XH Black Nipple 14636
16 1 FLES125-12 11/4 X 12 Stainless Steel Double Braided Flex Connector With SCH80 Threaded Ends 187501
17 1 F/S114UN3SE 11/4 Union 3000# Forged Steel Threaded 9101
18 1 F/S112X114BU 11/2 X 11/4 Bushing Forged Steel 8872
19 1 NIPCS1X34XH 1 X 3/4 Concentric Swedge Nipple XH 187219
20 1 F/S34T3SE 3/4 Tee 3000# Forged Steel Threaded 8715
21 4 NIP34X6XH 3/4 X 6 XH Black Nipple 14602
22 1 RGO3127U Rego 1/4 Hydrostatic Relief Valve 450# 162428
25 1 F/S14S903SE 1/4 Street 90 Elbow 3000# Forged Steel Threaded 8723
26 1 CRK1449 Corken Gauge Adapter/Pressure Snubber 1/4 M/F 181098
27 1 RGO1224WA Rego 1/4 Needle Valve 186802
28 1 F/S14C03SE Coupling 3M FS TH 1/4
29 1 GAUP300 Ashcroft 21/2 Dial 1/4 Bottom Connection 0-300 psi 36489
31 21 D/P34XHBPE 3/4 X 21 SCH 80 Black Pipe Price Per Foot 45478
30 6 F/S34903SE 3/4 90 Elbow 3000# Forged Steel Threaded 8691
32 1 RGO7550P Rego 3/4 Angle Valve M/F 162760
33 1 RGO7590U-10 Rego Check-lok Adapter, Possible Alternate RGO7572-14C For Older Style Check-lok 162762
34 1 F/S34CO3SE 3/4 Coupling 3000# Forged Steel Threaded 8735
35 2 HGR1GUBOLT 1 Galvanized U-Bolt With Nuts 69033
36A 3 HOS3/4 3 - 3/4 LP Dayco Hose 185604
36B 2 HOSHY12-12MP 3/4 Hydraulic Hose Ends For Dayco Hose 185576
37 1 RGOA2141A6 Rego 3/4 Breakaway/Pullaway Coupling 162683
38 1 F/S34X12BU 3/4 X 1/2 Bushing 3000# Forged Steel 8857
39A 18 HOS1/2 18 - 1/2 LP Dayco Hose 185581
39B 2 HOS7661-08MP08TY 1/2 Hydraulic Hose Ends For Dayco Hose 193208
40 1 RGO7901TB Rego 1/2 X 1/4 Snap Acting Hose Valve 162488
41 1 RGO7193D-10 1/4 X MPOL Rego Hose Adapter 186884
not shown 1 RGO7193T-10 FPOL X 15/16 F Acme Adapter Rego FPOL-QCC1 Adapter 162472
not shown 1 FBS1124 Fairbanks 1124 1000# Scale 181957
182
victormfg.com
Pump Station Kits
9
SECTION
Gas Equipment Catalog
Pump Station With Meter
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pump Station Kits
183
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Pump Station With Meter (continued)
Pump Station Schematic Drawing Key With Meter
DRAWING QTY ALPHA CODE DESCRIPTION WEBB#
1 1 G/T1000AG Tank LP Above Ground 1000 Gal. 185224
1 1 G/T500AG-B Tank LP Above Ground Bot./Drn. 500 215818
2 2 SAE38RNUT Nut Short Ref. 3/8 * NS45 E6NUT 34571
3 1 SAE38X14MUN Union 3/8 X 1/4 FLR X M * U1-6B 19780
4 1 SAE38X14M90 ELL 90 3/8 X 1/4 FLR X M * E1-6B 19834
5 1 PIG1005 POL X 3/8 Male Flare 186522
6 2 SAE58X34MUN Union 5/8 X 3/4 FLR X M * U1-10E 19791
7 2 SAE58RNUT Nut Short Ref 5/8 * NS410 E10NU 34814
8 1 RGO7550P Valve Angle Trans. * 3/4 162760
9 1 RGO7590U-10 Adapter Check Lock * 3/4 162762
10 2 RGO3127U Valve Relief Hydro 450 1/4 162428
11 1 RGOA8017DP Valve Multi Purpose 11/4 MN 162493
12 1 NIPCS114X1XH Nipple Conc. Swedge 11/4 X 1 X H 187220
13 1 F/S1903SE Elbow 90 3M FS TH 1 8692
14 1 NIP1X 3XH Nipple Black X H 1 X 3 STL 14612
15 1 F/S114903SE Elbow 90 3M FS TH 11/4 8693
16 1 NIP114XHPAK Nipple BLK X H PAK 1 EA 11/4 X CLO 111655
17 1 SCSB112AD-114 STRNR 11/4 DI 600 THD 20 MESH 184114
18 1 F/S1PL Plug 3M FS SQ HD 1 8832
19 1 FLES125-12 Hose 11/4 X 12 SS SGL BRD S80MN 187501
20 1 F/S114UN3SE Union 3M FS TH AAR 11/4 9101
21 1 NIPCS112X114XH Nipple Conc. Swedge 11/2 X 11/4 X H 187221
22 1 CRKC12SMB Kit Pump 1 HP MTR MNT SW 3/4 BY 181039
23 1 NIPCS1X34XH Nipple Conc. Swedge 1 X 3/4 X H 187219
24 1 F/S34T3SE Tee 3M FS TH 3/4 8715
25 1 NIP34XHPAK Nipple BLK X H PAK 1 EA 3/4 X CLO 111669
26 1 F/S34UN3SE Union 3M FS TH AAR 3/4 9099
27 1 NIP34X24XH Nipple Black 34 X 24 X H WLD 318897
28 3 F/S34903SE Elbow 90 3M FS TH 3/4 8691
29 1 F/S34T3SE Tee 3M FS TH 3/4 8715
30 1 F/S34X12BU Bushing 3M FS HEX 3/4 X 1/2 8857
31 1 RGO3129U Valve Relief Hydro 450 1/2 162432
32 1 LIQLPM102 Meter Flow With 1 Gallon Register 182604
33 1 RGO3272G Valve Excess Flow 3/4 162584
34 3 HOS3/4 Hose LP 3/4 7132-75354 185604
35 2 HOSHY12-12MP Coupling Hydraulic 3/4 185576
36 1 RGOA214A6 Valve Pull Away 3/4 162683
37 1 F/S34X12BU Bushing 3M FS Hex 3/4 X 1/2 8857
38 18 HOS1/2 Hose LP 1/2 7132-50354 185581
39 2 HOS7661-08MP08TY Coupling Hydraulic 1/2 193208
40 1 RGO7901TB Valve Quick Act 1/4 FN X 1/2 FN 162488
41 1 RGO7193D-10 Connector Fill With Soft Nose 186884
42 1 RGO7193T-10 Adapter Fill FPOL X 15/16 AC 162472
43 1 RGO07193L-10A Connector Fill 162471
184
victormfg.com
Pump Station Kits
9
SECTION
Gas Equipment Catalog
Pump Station With Meter (continued)
Pump Station Schematic Drawing Key With Meter
DRAWING QTY ALPHA CODE DESCRIPTION WEBB#
44 1 RGO5760A Adapter FP X 1/4 FN 162457
45 1 SHR901H FPOL X 13/4 Acme S 184119
46 1 CRK1449 Adapter Pressure Gauge 181098
47 1 F/S14S903SE Elbow 90 3M FS TH ST 1/4 8723
48 1 RGO1224WA Valve Needle Brass 1/4 186802
49 1 F/S14CO3SE Coupling 3M FS TH 1/4 8732
50 1 ASH00516 Gauge 63 3005PHL 02L 300 110920
51 42 D/P2BPE Pipe S40 BLK PE 2 X FT 45504
52 8 HGR12GWASHER Washer Flat PLT 1/2 130 PG 69051
53 4 HGR12GNUT Nut HEX HD PLT 1/2 110 HPG 69046
54 4 HGR12X2GBOLT Bolt HEX HD GAL 1/2 X 2 41 PG 34458
55 1 VCTTANKST Stands Tank With Pump 184438
56 1 FBS1124 Scale Portable Beam 181957
57 1 MIL48-89-1565 Bit Twist Drill 1/4 74665
58 1 MIL48-89-1645 Bit Twist Drill 1/2 247642
59 15 Feet 1/4 K Soft Copper 362953
60 10 Feet 1/2 K Soft Copper 360279
Victor/F.w. Webb
stocks york furnaces.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pumps/Compressors
185
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Coro-Flo
Turbine Pumps
C-Model With Close Coupled Motor
SPECIFICATIONS MODEL
10 12 13 14
Inlet 11/4 NPT 11/2 NPT 11/2 NPT 11/2 NPT
Outlet 1 NPT 1 NPT 1 NPT 1 NPT
RPM-60 Hz 3450 3450 3450 3450
Max. Differential Press.
50 Hz PSI (Bar) 60 (4.1) 75 (5.2) 75 (5.2) 75 (5.2)
60 Hz PSI (Bar) 70 (4.8) 100 (6.9) 125 (8.6) 125 (8.6)
Mounting Options
Close Coupled Yes Yes Yes Yes
Direct Driven (101) Yes Yes Yes Yes
V-Belt (103) Yes Yes Yes Yes
Direct Mounted Frame
(DS/DL) Yes Yes Yes Yes
Double Seal Option
(Except C-Model) Yes Yes Yes Yes
Flange Option
11/2 X 1 300# Yes Yes Yes Yes
(Except C-Model)
Impeller Material Opt. Bronze (Standard), Ductile Iron, Stainless Steel
O-Ring Material Opt.
Tefon(r), Viton(r), Buna-N (Standard), Neoprene(r), Tefon(r),
Ethylene-Propylene Viton(r), Ethylene-Propylene
Seal Seat
Material Options
Ceramic Ni-Cast Iron, Cast Iron (Standard), Ni-Resist, Stainless Steel,
SS304, Tungsten Carbide Tungsten Carbide, Ceramic
Temperature -25/225F -25/225F -25/225F -25/225F
(min/max) -32/107C -32/107C -32/107C -32/107C
Maximum Driver 5 HP 10 HP 10 HP 20 HP
3.7 KW 7.5 KW 7.5 KW 15 KW
MFR# DESCRIPTION WEBB#
Dispensing Station Pumps
CRKC10S 3/4 HP, 115/230V Remote 181031
CRKC10SB 3/4 HP, Remote Switch, Bypass 181032
CRKC10SM 3/4 HP, 115/230V Switch 181033
CRKC10SMB 3/4 HP, SW Mount & Bypass 181034
CRKC12 1 HP Motor 181035
CRKC12S 1 HP 115/208/230 Remote 181036
CRKC12SB 1 HP Motor, Remote Switch 181037
CRKC12SM 1 HP 115/208/230 Switch 181038
CRKC12SMB 1 HP Kit, SW Mount 3/4 Bypass 181039
CRKC13 2 HP Motor 212890
CRKC14 3 HP Motor, SW Mount 204939
Stationary Applications
Designed specifcally for LPG
The Corken Coro-Flo
pump was designed for LPG, NH3 and other light liquids. For low-
capacity, medium-head pumping, the Coro-Flo pump is the pump of choice. Extremely
quiet and free of vibration and pulsation, the Coro-Flo pump provides trouble-free service
and long life for volatile liquids such as LPG. The exclusive turbine construction provides
smooth continuous fow through the pump case, resulting in higher effciency and greater
capacity and pressure for the same size motor. The one moving part, the impeller, foats on
the shaft without contacting adjacent surfaces, thus extending pump life.
Simple to Service
The Coro-Flo
pump has been designed for simplicity of inspection and service. The cover
can be removed and the impeller and seal serviced without disturbing the piping. The
balanced mechanical seal is furnished with its own sleeve, providing extremely reliable service.
The Coro-Flo pump is listed by Underwriters Laboratories, Inc. for use in LP-Gas and
anhydrous ammonia service.
186
victormfg.com
Pumps/Compressors
9
SECTION
Gas Equipment Catalog
MOTOR (A) RECOMMENDED WIRE SIZE, AWG
MODEL HP
MOTOR
PHASE VOLTS
APPROXIMATE FULL
LOAD AMPERES
LENGTH OF RUN IN FEET
0-100 TO 200 TO 300
C9
C10
3/4
115
230
9.0
5.0
12
12
8
12
6
12
C12 1 1
115
230
16.0
8.0
8
12
6
12
4
10
C13 2 1 115
230
20.0
10.0
8
12
4
10
2
8
C14 3 3 230
460
8.0
4.0
12
12
12
10
12
8
Coro-Flo
Turbine Pumps
Stationary Applications (continued)
FOR MODELS C9, C10, C12 AND C13 FOR MODELS C14 ONLY
115V
2277-X1 OR 2277-X2 SWITCH
LINE
LINE
L2 T2
L1
T1
T2
T3
T4
T1 L1
T2 L2
T1
T3
T1
T2
T4
LINE
LINE
208-230V
2277-X1 OR 2277-X2 SWITCH
208-230V 460V
LINE
LINE
4 7 1
8 2
9
7
8
9 3
5
6
4
5
6
LINE
LINE
LINE
1
2
3
LINE
FOR MODELS C9, C10, C12 AND C13 FOR MODELS C14 ONLY
115V
2277-X1 OR 2277-X2 SWITCH
LINE
LINE
L2 T2
L1
T1
T2
T3
T4
T1 L1
T2 L2
T1
T3
T1
T2
T4
LINE
LINE
208-230V
2277-X1 OR 2277-X2 SWITCH
208-230V 460V
LINE
LINE
4 7 1
8 2
9
7
8
9 3
5
6
4
5
6
LINE
LINE
LINE
1
2
3
LINE
Wire Sizing Chart
Pump must rotate in the direction shown on pump case. If not, switch any two of the three incoming 3 phase lines.
Victor/F.w. Webb stocks
electrical test equipment.
See our tools section in this catalog.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pumps/Compressors
187
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Coro-Flo
Pumps
F-Model 101 Direct Drive
FF150CD6A
DS/DL-Model Direct Mounted
MFR# DESCRIPTION WEBB#
Dispensing Station/Aerosol/Refrigerant Pumps
CRKF10CD Pump f/10 181043
CRKF12CD Bare Coro-Flo 181044
CRKF14CD Bare Coro-Flo 181045
CRKDL14 Direct Mount, Large Frame 181211
CRKDS12CDC Direct Mount, Small Frame 181216
FF150CD6A Autogas Pump 369968
SPECIFICATIONS
MODELS
FF150 DLF150
Inlet 11/2 ANSI 300# R.F. Flange 11/2 ANSI 300# R.F. Flange
Outlet 1 ANSI 300# R.F. Flange 1 ANSI 300# R.F. Flange
RPM50 Hz 2,880 2,880
RPM60 Hz 3,450 3,450
Maximum Working Pressure
28.5 bar
(400 psi)
28.5 bar
(400 psi)
Maximum Differential Pressure
50 Hz
60 Hz
200 psi (13.8 bar)
250 psi (17.2 bar)
200 psi (13.8 bar)
250 psi (17.2 bar)
Mounting Options
Direct Driven (101) Yes No
V-Belt (103) Yes No
Direct Mounted Frame No Yes
Impeller Material Options Bronze (Standard), Ductile Iron, Stainless Steel
O-Ring Material Options Buna-N (Standard), Neoprene
1, PTFE
1, Viton
1, Ethylene-Propylene
Seal Seat Material Options Cast Iron (Standard), Ni-Resist, Stainless Steel, Tungsten Carbide, Ceramic
Temperature
(Min/Max)
(-25) 225F
(-32) 107C
(-25) 225F
(-32) 107C
Maximum Driver
20 hp
15kW
20 hp
15kW
Type of Electric Motor Rigid-Base C-Face
Autogas Pumps Operating Specifcations
1 Neoprene
, Viton
and PTFE
are registered trademarks of the
DuPont Company.
Autogas Pumps
Corken Autogas Pump achieves new levels of performance with higher fows at high
differential pressures, non-pulsating and quiet transfer, longer pump life and a design that
is easy to repair. The pump is also versatile enough to be used in like applications such as
cylinder flling, vaporizer feeding, or bulk transfer.
F-Model
The F-Model pump is the base plate mounted version. Coro-Flo
Pumps (continued)
Autogas Capacity Chart
Victor/F.w. Webb stocks the laars
mascot gas boiler. it provides both heat
and domestic hot water!
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Pumps/Compressors
189
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Coro-Vane
Pumps
Bulk Filling, Carousel Filling & Cylinder Filling
MFR# DESCRIPTION WEBB#
Stationary Plant Pumps
CRK521EF* Stationary Coro-Vane 181022
CRK521EG103* Coro-Vane Pump With Mount 181023
CRK1021EF* Bare Coro-Vane Pump 181013
CRK1021EF103* Coro-Vane Pump With Mount 284T 181042
Z3500 Coro-Vane Z-Pump 401115
Z3500-103 Pump With Mount 401116
521
521 1021 1521
1021 1521
10 20 30 40 50 60 80
420
640
860
950
420
640
860
950
100 150 200
GPM
M
3
/hr
R
P
M
250 300
100 PSID
(6.90 Bar)
40 PSID
(2.76 Bar)
Corken Coro-Vane
Truck Pumps
Z3200
Z4200
Specications
SPECIFICATIONS MODELS
Z3200 Z4200
Suction Flange 3 4
300# ANSI 300# ANSI
Discharge Flange 2 2
NPT EI Dual NPT
Maximum RPM 800
Minimum -25F
Temperature (-32C)
Maximum 225F
Temperature (107C)
Maximum 400 PSIG
Working Pressure (28.6 Bar)
Maximum 125 PSID
Differential Pressure (8.6 Bar)
Discharge
Flange Open Yes No
Internal Relief Valve Yes Yes
Steel Slip-On
Flange Option Yes Yes
Z3200 Performance Chart
PUMP SPEED
DIFFERENTIAL
PRESSURE
APPROXIMATE
DELIVERY ON PROPANE BRAKE HP REQUIRED
PUMP TORQUE
REQUIRED
RPM PSI BAR GPM LPM BHP KW FT. LBS. KG/M
800
800
50
100
6.9
121
110
460
420
6.6
10.6
4.9
7.9
43.4
69.3
6.0
9.6
650
650
50
100
3.4
6.9
98
88
371
333
5.2
8.2
3.9
6.1
42.0
66.3
5.8
9.2
500
500
50
100
3.4
6.9
73
63
276
238
3.8
5.8
2.8
4.3
39.9
60.9
5.5
8.4
The Z-Series Coro-Vane
1, PTFE
1, Viton
1, Ethylene-Propylene*
MFR# DESCRIPTION WEBB#
B166B75B 3/4 Coro-Flo
/Autogas 181026
B166B1B 1 Coro-Flo
/Autogas 181025
B177125B 11/4 Coro-Vane
181027
B177150 11/2 Coro-Vane
181028
B1772B 2 Coro-Vane
181029
T1661.25 11/4 Truck Pump 181049
Bypass ValvesSpecifcations for B166, T166, B177 and ZV200
* Ethylene-Proplyene not available for B177, 1 PTFE
, Vitron
and Neoprene
3
1014
2
1014-1
2
Case Clearance Shim
(.002 Red)
Case Clearance Shim
(.003 Green)
As
Req.
As
Req.
181071
4
2-246
2, 3
2-247E
2
Case O-Ring (Non-Tefon
1
)
Case O-Ring Tefon
1
1
1
5
1003-09
6
1003-0
6
1003-2
6
1003-3
6
1003-4
6
1003-5
6
Impeller, BrassModel 9
Impeller, BrassModel 10
Impeller, BrassModel 12
Impeller, BrassModel 13
Impeller, BrassModel 14
Impeller, BrassModel 15
1
1
1
1
1
1
181060
181062
181063
181064
6
113-CX_
3
113-CXA
113-CXB
113-CXD
113-CXE
Seal Assembly
Seal Assembly
Seal Assembly
Seal Assembly
Seal Assembly
1
1
1
1
1
181075
181076
181077
181057
7
1004-1X
1004-11X
1004-2X
1004-21X
Seal Housing, Steel
(Non-Tefon
1
O-Rings)
Seal Housing, SS
(Non-Tefon
1
O-Rings)
Seal Housing, Steel
(Non-Tefon
1
O-Rings)
Seal Housing, SS
(Non-Tefon
1
O-Rings)
1
1
1
1
310362
8
1013
1013-1
Housing Adjustment Shim
(0.010)
Housing Adjustment Shim
(0.020)
As
Req.
As
Req.
181069
13 1914-1 Nameplate 1
14
7012-
006SF019E
Phillips Head Screw 6 32X1/4 2
15
7002-
037NC087A
Socket Head Cap Screw 8
16 1015 Adapter Ring 1
17
2497
2497-1
Woodruff Key, Steel
Woodruff Key, SS
1
1
18
2555
2556
2557
5
2895
5
2896
5
4261
4
Motor 3/4 HP Models 9, 10
Motor 1 HP Model 12
Motor 3 HP Models 14, 15
Motor 3/4 HP,
Obsolete Models 9E, 10
Motor 11/2 HP,
Obselete Model 12E
Motor 2 HP Model 13
1
1
1
1
1
1
181167
181168
1
Registered trademarks of the DuPont Company.
2
Included with seal assembly/repair kit 113-CX_.
3
_Denotes O-Ring Code.
4
Prior to S.N. PR166727 motor part number was 3760.
5
Starting with S.N. PW168290 will be new motor frame size.
6
Add a 1 to # for iron or a 2 for stainless steel
(example: model 10 with iron is 1003-01).
198
victormfg.com
Repair Parts
9
SECTION
Gas Equipment Catalog
Parts Details for Models
F9C to F15C, FF9 to FF15C and F109 to F115
REF# MFR# DESCRIPTION QTY WEBB#
1
7001-
031NC100A
Hex Head Cap Screw 8
2
1001-09
1001-0
1001-2
1001-3
1001-4
1001-5
CoverModel 9
CoverModel 10
CoverModel 12
CoverModel 13
CoverModel 14
CoverModel 15
1
1
1
1
1
1
3
1014
2
1014-1
2
Case Clearance Shim
(.002 Red)
Case Clearance Shim
(.003 Green)
As
Req.
As
Req.
181071
4
2-246
2, 3
2-247E
2
Case O-Ring (Non-Tefon
1
)
Case O-Ring Tefon
1
1
1
5
1003-09
4
1003-0
4
1003-2
4
1003-3
4
1003-4
4
1003-5
4
ImpellerModel 9
ImpellerModel 10
ImpellerModel 12
ImpellerModel 13
ImpellerModel 14
ImpellerModel 15
1
1
1
1
1
1
181060
181062
181063
181064
6
113-CX_
3
113-CXA
113-CXB
113-CXD
113-CXE
Seal Assembly
Seal Assembly
Seal Assembly
Seal Assembly
Seal Assembly
1
1
1
1
1
181075
181076
181077
181057
7
1004-1X
1004-11X
1004-2X
1004-21X
Seal Housing, Steel
(Non-Tefon
1
O-Rings)
Seal Housing, SS
(Non-Tefon
1
O-Rings)
Seal Housing, Steel
(Non-Tefon
1
O-Rings)
Seal Housing, SS
(Non-Tefon
1
O-Rings)
1
1
1
1
310362
8
1013
1013-1
Housing Adjustment Shim
(0.010)
Housing Adjustment Shim
(0.020)
As
Req.
As
Req.
181069
9 2-224_
3
O-Ring (Housing) 1
10 3442 Pipe Plug, 1/4 1
11 3444 Pipe Plug, 3/4 1
REF# MFR# DESCRIPTION QTY WEBB#
12
1002-09
1002-0
1002-2
1002-3
1002-4
1002-5
4206-09
4206-0
4206-2
4206-3
4206-4
4206-5
CaseModel 9
CaseModel 10
CaseModel 12
CaseModel 13
CaseModel 14
CaseModel 15
CaseANSI Flanged Model 9
CaseANSI Flanged Model 10
CaseANSI Flanged Model 12
CaseANSI Flanged Model 13
CaseANSI Flanged Model 14
CaseANSI Flanged Model 15
1
1
1
1
1
1
1
1
1
1
1
1
13 1914-1 Nameplate 1
14
7012-
006SF019E
Phillips Head Screw 6 32X1/4 2
15 5002-281 Bearing Retainer Ring 1
16 1238 Bearing Cap 1
17 1006 Grease Seal 1 181067
18 5102-118 Bearing Retainer Ring 1
19 2758 Ball Bearing 1 181176
20 5000-281 Bearing Retainer Ring 1
21
2497
2
2497-1
2
#5 Woodruff Key, Steel
#5 Woodruff Key, SS
1
1
22
1234
1234-1
Shaft
Shaft, Stainless Steel
1
1
181091
23 3226 Key 1
24 2759 Ball Bearing 1 181177
25 1010-2 Frame 1
26
7002-
037NC087A
Socket Head Screw 4
27 2158 Grease Zerk 2
28 2159 Lubricap 2
1
Registered trademarks of the DuPont Company.
2
Included with seal assembly/repair kit 113-CX_.
3
_Denotes O-Ring Code.
4
Prior to S.N. PR166727 motor part number was 3760.
5
Starting with S.N. PW168290 will be new motor frame size.
6
Add a 1 to # for iron or a 2 for stainless steel
(example: model 10 with iron is 1003-01).
O-Ring Code
A
Buna-N
B
Neoprene
1
D
Vitron
1
E
Tefon
1
G
Ethylene
Propylene
1
K
Kalrez
1
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Repair Parts
199
9
SECTION
P
U
M
P
S
/
C
O
M
P
R
E
S
S
O
R
S
9
Parts Details For Stationary Coro-Vane
Pumps
Models 521 and 1021
200
victormfg.com
Repair Parts
9
SECTION
Gas Equipment Catalog
Parts Details For Stationary Coro-Vane
Pumps
Models 521 and 1021 (continued)
REF# MFR# DESCRIPTION QTY WEBB#
1
1162-2
1201-2
Cam (521)
Cam (1021)
1
1
181078
181086
2
2832
2841
Case (521)
Case (1021)
1
1
3
1172-2.5
3
1172-2
3
1206-3
4
2.5 Flange (521)
2 Flange (521)
3 Flange (1021)
1
1
2
4
2-234_
2, a
2-245_
2
2-249_
2
Flange O-Ring (521)
Flange O-Ring 3 (1021)
Flange O-Ring 4 (1021)
2
2
2
181148
5 2-112_
2
Adjusting Screw O-Ring 1
6 2590 Flush Seal Plug 1/8 NPT 1
7 2252 Relief Valve Adjusting Screw 1
8
1174
1207
Valve Cap (521)
Valve Cap (1021)
1
1
9
1242-X
1227
Relief Valve Spring & Guide (521)
Relief Valve Spring Guide (1021)
1
1
10
2-224_
2
2-228_
2
Relief Valve Cap O-Ring (521)
Relief Valve Cap O-Ring (1021)
1
1
11
1241
1224
Relief Valve (521)
Relief Valve (1021)
1
1
12
1242
1226
Relief Valve Spring (521)
Relief Valve Spring (1021)
1
1
13
1170
1309
Cam Key (521)
Cam Key (1021)
1
1
14
1168-7
1308-9
Blade (521)
Blade (1021)
10
10
181094
15
116-1X1R
1208-1X1R
Rotor & Shaft Assembly (521)
Rotor & Shaft Assembly (1021)
1
1
181089
16 1358 Grease Seal 2
17 1164-1 Bearing Cap 2
18 2158 Grease Zerk 1/8 NPT 2
19 1769 Bearing Housing 2
20 1343 Relief Fitting (Seal Vent) 2
21
1769-X_
1, 2, a
1769-XR_
1,2,a
Seal Assembly
Seal AssemblyReplacement
2
2
181126
181127
22
1163-2
8
1209-1
8
Sideplate (521)
Sideplate (1021)
2
2
23
1161-4
1205-4
Head (521)
Head (1021)
2
2
24
2754-X
2755
2754
Roller BearingComplete
Bearing Inner Race
Bearing Outer Race
2
2
2
35
7001-037
NC125A
7001-037
NC125A
Hex Head Bolt 3/8 16X1 1/4
(521)
Hex Head Bolt 3/8 16X1 1/4
(1021)
28
32
36
7001-037
NC150A
Hex Head Bolt 3/8 16X1 1/2 8
37
5
Retainer 2
38
5
Seal Seat 2
39 2-227_
2
Seal Seat O-Ring 2
40 2159 Lubricant #2 2
41 1359 Lubricant Instruction Tag 2
42
7003-004
DR0198
Round Head Plated Drive Screw
4X3/16
2
1
Seal assemblies are available in two forms:
a. Complete seal kit including bearing housing,
seat adapter plate, bearings, retainer ring,
seal and O-Rings. Part number 1769-X_
2
.
b. Field replacement seal assembly containing only
the seal and O-Rings. Part number 1769-XR_
2
.
2
_denotes O-Ring code
3
Optional fanges, (model 521):
1172-1.5 1/2 NPT
1172-1.5S 1/2 Weld
1172-2 2 NPT
1172-2S 2 Weld
1172-2.5 21/2 NPT
1172.2.5S 2 1/2 Weld
4
Optional fanges, (model 1021):
1206-3S 3 Weld
1206-4 4 NPT
1206-4S 4 Weld
5
Not available separately.
6
Neoprene
, Viton
, and Tefon
Pumps
C51/F51 Standard Repair Kits
(no kit available) C51/F51 Additional Spare Parts
521 Repair Kit 2904-X2
1
521 Additional Spare Parts
F1521 Additional Spare Parts
1021/F1021 Additional Spare Parts
MFR# DESCRIPTION QTY WEBB#
2296-1X_5 Seal Assembly 1
2451-2 Vane 8
2-154_ Case O-Ring 2
2491 Sideplate 2
MFR# DESCRIPTION QTY WEBB#
2492-X Rotor & Shaft Assembly 1
2471 Roller Bearing 2
MFR# DESCRIPTION QTY WEBB#
1163-2 Sideplate 2
181179
1168-7 Vane 10
1358 Grease Seal 2
1769-XRA Seal Assembly (Replacement) 2
2-112A O-Ring, Buna-N 1
2-224A O-Ring, Buna-N 1
2-227A O-Ring, Buna-N 2
2-234A O-Ring, Buna-N 2
2-261A O-Ring, Buna-N 2
2010 Flange Gasket 3
2014 Grease Seal, Thrust 1
2754-X Roller Bearing 2
MFR# DESCRIPTION QTY WEBB#
1166-1X1R Rotor & Shaft Assembly 1
1162-2 Cam (Liner) 1 181078
F1521 Repair Kit 2907-X3
1
MFR# DESCRIPTION QTY WEBB#
1358 Grease Seal 2
1769-XRA Seal Assembly (Replacement) 2
2-234A O-Ring, Buna-N 3
2-238A O-Ring, Buna-N 1
2-245A O-Ring, Buna-N 1
2-249A O-Ring, Buna-N 1
2-268A O-Ring, Buna-N 2
2014 Grease Seal, Thrust 1
2754 Bearing Outer Race 2
3209 Ball Bearing 1
3476-L Sideplate, Left 1
3476-R Sideplate, Right 1
3477 Vane 6
MFR# DESCRIPTION QTY WEBB#
3350-X1R Rotor & Shaft Assembly 1
1792-1 Cam (Liner) 1
1021/F1021 Repair Kit 2906-X2
MFR# DESCRIPTION QTY WEBB#
1209-1 Sideplate 2
181182
1308-9 Vane 10
1358 Grease Seal 2
1769-XRA Seal Assembly (Replacement) 2
2-112A O-Ring, Buna-N 1
2-228A O-Ring, Buna-N 1
2-245A O-Ring, Buna-N 2
2-249A O-Ring, Buna-N 2
2-268A O-Ring, Buna-N 2
2014 Grease Seal, Thrust 1
2754-X Roller Bearing 2
MFR# DESCRIPTION QTY WEBB#
1208-1X1R Rotor & Shaft Assembly 1 181089
1201-2 Cam (Liner) 1 181086
1
All repair kits have Buna-N O-Rings which are suitable for both
LPG and NH
3
applications.
204
victormfg.com
Repair Parts
9
SECTION
Gas Equipment Catalog
Repair/Re-build Kits
Z2000, ZH2000, ZX2000, ZXH2000
Repair Kit 3193-X1
Z4200, ZH4200, Z4500
Repair Kit 3197-X1
Z3500 Repair Kit 3195-X2
Z3200, ZH3200 Repair Kit 3195-X1
MFR# DESCRIPTION QTY WEBB#
2-224A O-Ring, Buna-N 1
2-231A O-Ring, Buna-N 2
2754-X Roller Bearing 2
4262-X Vane Driver 3
4428 Vane 6
4431-XA2 Seal Assembly 2
4432 Thrust Bearing 2
4435 Thrust Bearing Mounting Ring 2
4439 Bearing Cap Shim (0.002) 8
4439-1 Bearing Cap Shim (0.010) 2
4439-2 Bearing Cap Shim (0.020) 2
4441 Grease Seal 2
2270 Shaft Key 1
MFR# DESCRIPTION QTY WEBB#
2-231A O-Ring, Buna-N 1
2-234A O-Ring, Buna-N 2
4460-X Roller Bearing 2
4449-X Vane Driver 5
4448 Vane 6
4464-XA2 Seal Assembly 2
4453 Thrust Bearing 2
4454 Thrust Bearing Mounting Ring 2
4458 Bearing Cap Shim (0.002) 8
4458-1 Bearing Cap Shim (0.010) 2
4458-2 Bearing Cap Shim (0.020) 2
4463 Grease Seal 2
4459 Shaft Key 1
Z2000, ZH2000, ZX2000, ZXH2000
Re-Build Kit 3194-X1 includes
all items in the Repair Kit plus
the following:
Z3200, ZH3200 Re-Build Kit 3196-X1
includes all items in the Whole Kits
Repair Kit (#181238)plus the following:
Z3500 Re-Build Kit 3196-X2
includes all items in the Repair Kit
plus the following:
Z4200, ZH4200, Z4500 Re-Build Kit
3198-X1 includes all items in the
Repair Kit plus the following:
MFR# DESCRIPTION QTY WEBB#
4414 Cam 1
4427 Sideplate 2
MFR# DESCRIPTION QTY WEBB#
4242 Cam 1 181217
4231 Sideplate 2
MFR# DESCRIPTION QTY WEBB#
5539 Cam 1
3935 Sideplate 2
MFR# DESCRIPTION QTY WEBB#
4443 Cam 1
4446 Sideplate 2
MFR# DESCRIPTION QTY WEBB#
2-228A O-Ring, Buna-N 2
2754-X Roller Bearing 2
5554-X Vane Driver 3
3936 Vane 6
4431-XA2 Seal Assembly 2
4432 Thrust Bearing 2
4435 Thrust Bearing Mounting Ring 2
4439 Bearing Cap Shim (0.002) 8
4439-1 Bearing Cap Shim (0.010) 2
4439-2 Bearing Cap Shim (0.020) 2
4441 Grease Seal 2
2270 Shaft Key 1
MFR# DESCRIPTION QTY WEBB#
2-224A O-Ring, Buna-N 1
181237
2-234A O-Ring, Buna-N 2
2754-X Roller Bearing 2
4262-X Vane Driver 3
4232 Vane 6
4431-XA2 Seal Assembly 2
4432 Thrust Bearing 2
4435 Thrust Bearing Mounting Ring 2
4439 Bearing Cap Shim (0.002) 8
4439-1 Bearing Cap Shim (0.010) 2
4439-2 Bearing Cap Shim (0.020) 2
4441 Grease Seal 2
2270 Shaft Key 1
1
All repair kits have Buna-N O-Rings which are suitable for both
LPG and NH
3
applications.
TO ORDER, CALL: 800.243.9360 CT: 860.722.2433 FAX: 800.274.2004
Generators
205
10
SECTION
M
I
S
C
E
Q
U
I
P
M
E
N
T
10
Guardian