You are on page 1of 25

WCDMA UTRAN Optimization Flow

ISSUE 1.0

Huawei Confidential. All Rights Reserved

WCDMA optimization is very important part in the life of the network. Mainly, the optimization contents the preparation, single site verification, RF optimization, parameters optimization.

Internal Use

Chapter 1 Introduction of Optimization Flow Chapter 2 The preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

Introduction of Optimization Flow

Roles and Responsibility The Working Flow

Document output

Internal Use

Chapter 1 Introduction of Optimization Flow Chapter 2 The Preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

The Preparation for Projection

Getting the Network Information


Environment Partition and Optimization Group

Optimization Tools and Software

Internal Use

The Preparation for Projection

Getting the Network Information The radio network planning report The radio network optimization report (optional) The parameters tables about UTRAN The statistic data and the information reflected by users

Internal Use

The Preparation for Projection

Optimization tools and Optimization software Optimization tools UMTS scanner (DTI) UMTS test UE Digital camera, GPS, Compass YBT250 to position interference Optimization software Probe Assistant Traffic statistic data analysis Mapinfo

Internal Use

Chapter 1 Introduction of Optimization Flow Chapter 2 The preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

Single Site Verification

Preparation Checking Warning Checking the state of cell Checking the parameters of radio access network Checking the configuration: scrambling code, configuration, neighbor cell table, handover parameters

power

Internal Use

Single Site Verification

Site verification

Checking the service function of each site Signal strength Feeder Jumper LA/RA update PS attach PS attach PS detach The voice call setup PDP active Intra-frequency handover Inter-system handover Inter-system cell-reselection.

Internal Use

10

Chapter 1 Introduction of Optimization Flow Chapter 2 The preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

11

RF Optimization

Purpose

Optimize CPICH, services coverage and best server Decrease the interference at the minimum level Decrease the pilot pollution at the minimum level Optimize neighbor cells table Solve the call drop caused by RF

Internal Use

12

RF Optimization

Drive test

Preparation Tools Map Parameters Car, human resource Data analysis Poor coverage Best Server Pilot pollution Neighbor cells table Interference Call drop caused by RF

Internal Use

13

RF Optimization
HUAWEI Recommendation Description & Reason

Operator Planning Department OMC change form, signed by SE

Operator OMC Department

Operator & HUAWEI OMC Engineer modify the parameter


Internal Use
14

Chapter 1 Introduction of Optimization Flow Chapter 2 The preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

15

Parameters Optimization

Purpose of parameters optimization

Drive test
Drive test for special area Statistic analysis Conclusion

Internal Use

16

Purpose of Parameters Optimization

Purpose of parameters optimization


Decrease the access success rate Decrease the call drop Increase the quality of service

The tools and data for analysis:


scanner and UE RNC record data Statistic tools and KPI MSC & SGSN record if necessary

Internal Use

17

Drive test

The contents of drive test


The call setup test for voice service The continuous call test for voice service Idle mode test The call setup test for video phone service The continuous call test for voice service The call setup test for PS service The continuous call test for PS service

The test should be performed repeatedly to the position with problems to make sure that the problem is repeatable

Internal Use

18

Drive Test Data Analysis

Drive Test Data Analysis

Analyzing and finding out the solution for access failure (system bugs, power control parameter, cell selection and reselection parameter etc.) Analyzing and finding out the solution for drop call (system bugs, power control parameter, handover parameter etc.) Analyzing and finding out the solution for service quality related problems (system bugs, power control parameter, RLC parameter etc.)

Internal Use

19

Adjustment Recommendation and Implementation

Adjustment Recommendation and Implementation

Common Control Channel Power Allocation parameters RL Maximum Power parameters Intra-frequency Handover parameters Inter-frequency Handover parameters Inter-RAT Handover parameters Power Control parameters Access parameters Other related parameters

Internal Use

20

Test for Special Areas

Special area refers to a small district or indoors environment


Operator offices, residence of VIP Key hotels or entertainment location Government location Locations of large company or group subscribers Locations tend to be cared , such as railway station or airport

Internal Use

21

Chapter 1 Introduction of Optimization Flow Chapter 2 The Preparation for the Optimization Project

Chapter 3 Single Site Verification


Chapter 4 RF Optimization Chapter 5 Parameters Optimization Chapter 6 Optimiztion Report

Internal Use

22

Optimization Report

The optimization report should be presented after the project passes the customer acceptance. The optimization report should include:

Project background introduction Existing network status Acceptance criteria Optimization process Problem analysis and adjustment recommendation, and the effect for the implemented part Acceptance test and result Leftover problems and suggestions from the optimization point of view.

Internal Use

23

Huawei Confidential. All Rights Reserved

You might also like