You are on page 1of 2

THE INFORMATION

CENTRE IC 970
Breaking
New Ground
In Energy Management
The Autometers i nformati on centre 900 seri es i s a new range of
meters whi ch has been speci fcal l y desi gned to meet the stri ct
requi rements of swi tchboard manuf acturers around the worl d.
Desi gned to be a meter whi ch i s not onl y ver y accurate but smal l
and compact, ( 96 square mm) easy to i nstal l . I t al so has an
opti onal advantage of bei ng abl e to be ftted at a l ater date wi th
communi cati on modul es for BMS systems.
The I C 900 seri es i s a range of Mul ti f uncti on meters oferi ng many
di ferent types of i nformati on rangi ng f rom j ust kWh ( I C 910) to a
meter showi ng many parameters i ncl udi ng vol tage and current
harmoni c anal ysi ng. ( I C 990) Al l the 900 seri es meters have been
desi gned to be f ul l y compl i ant to i ntegrate wi th the Autometers
Hori zon range of modul es for data l oggi ng and i nterrogati on.
Introduction
The accuracy - cri ti cal components i n the measurement ci rcui tr y are
al l passi ve, hi gh qual i ty and stabl e. The I C 970 conforms to meter
standard BS EN 61036. Overal l measurement accuracy i s, however
dependant on the accuracy of the external current transformers.
Measurement Accuracy
The I C970 i s a si ngl e key operati on devi ce. To obtai n i nformati on
press the appropri ate key; e. g. to di spl ay vol tage, press the VOLTS
key. The fol l owi ng i nformati on wi l l be di spl ayed showi ng readout
between phase to phase and phase to neutral .
Sequence
Al though the I C 970 meter can be used i n a stand al one si tuati on,
i t i s i deal for sub meteri ng measuri ng f rom di ferent depar tments
and l ocati ons. The meter has been desi gned to accept a pl ug i n
communi cati on modul e ( RS 485) whi ch enabl es i t to work wi th the
new Autometers Systems Hori zon range of data l oggers and data
transfer systems as wel l as many other management systems.
System Use
Customer care i s the cornerstone of the companys success. A
posi ti ve ser vi ce pol i cy i s obser ved throughout ever y speci al i st area
of operati on. The personal i nvol vement of al l the di rectors at ever y
l evel , a hi ghl y trai ned and moti vated staf, f ul l y computeri sed
systems and i n depth stockhol di ng combi ne to provi de a l evel of
ser vi ce whi ch has earned the appreci ati on of customers across the
spectrum of the UK and overseas markets. Computeri sed
di stri buti on systems are geared to a consi stent 24 hour despatch of
products, wi th 20 mi nute despatch bei ng possi bl e i n response to
urgent demand for smal l orders.
Dedicated Customer Service
Meteri ng and moni tori ng equi pment ranges f rom si ngl e phase and
Pol yphase kWh el ectromechani cal meters to a sophi sti cated range
of f ul l y programmabl e i nformati on centres. Al so avai l abl e are
El ectroni c Meters, Panel Mounted Meters, Maxi mum Demand
Meters, DI N Rai l Meters and Current Transformers.
Product Range
TECHNICAL PARAMETERS
3 Phase 4 Wire (LV) 230/400 Volts
50/60 Hz 5 Amp (CT Operated)
Volts Phase to phase. Phase to neutral ,
Mi ni mum and maxi mum val ues
Amps Phase, neutral & total ,
Mi ni mum and maxi mum val ues
Power Factor Phase & total
INST kW Phase & total
INST kVARh Phase & total
Act Demand Present demand wi th ti me i nto
peri od kW, kVAR, kVA, kA
Max Demand Peak demand kW, kVAR, kVAh, kA
Energy IMP
Total kWh, kVARh, kVAh
Energy EXP Total kWh, kVARh
Pulse Outputs kWh & kVAh
INST kVAh Phase & total
Hz System Frequency
On pressi ng the i nfor mati on key, a sequence of readouts
i ndi cati ng the meter s par ameter s wi l l be di spl ayed on the
f ront panel :
Model Number CT Setti ng and Neutr al CT Setti ng
Ver si on Number Pul se Setti ngs
Ser i al Number Functi on Features
Information
VOLTAGE
L1
-
- 230. 0
L2
-
- 230. 0
L3
-
- 230. 0
L1- L2
-
- 400. 0
L2- L3
-
- 400. 0
L3- L1
-
- 400. 0
Autometers Systems Limited,
4B Al bany Road,
Chorl ton- cum-Hardy,
Manchester.
M21 0AW
Tel: +44 ( 0) 161 861 9056
Fax: +44 ( 0) 161 881 3745
www. autometers. co. uk
Email: sal es@autometers. co. uk
TECHNICAL DATA
& PERFORMANCE
Product devel opment i s conti nuous and Autometers Systems Ltd reser ves the ri ght to make al terati ons
and manuf acture wi thout noti ce. Products as del i vered may therefore di fer f rom the descri pti ons and
i l l ustrati ons i n thi s publ i cati on.
Important.
The attention of the specifer, purchaser, installer or user is drawn to special measures and
limitations to use which must be observed when these products are taken into service to
maintain compliance with the CE directives. Details of these special measures and limitations
of use are available from HMSO.
REF: IEC 1000-5-1(BS195/210788DC) IEC 1000-5-2 (BS 195/214642DC)
IEC 10000-5-6 (BS 195/210789DC).
Measurements
The uni t i s desi gned for measuri ng 3 phase i n a 4 wi re star confgurati on.

Technical Parameters
Meter standard BS EN 61036
Accuracy Acti ve 1. 0, reacti ve 2. 0
Reference Vol tage 3 x 230/400 vol t
Basi c Current 5 amp
Maxi mum Current 6 amp
Frequency 50/60 Hz
Pul se Constant 5000 i mp/kWh, 5000 i mp/kVarh
Range of vol tage 200v 250 v
Operati on temperature - 10C + 50C
Storage temperature - 10C + 60C
Humi di ty <=95%
Power consumpti on 0. 01VA @5A; 1. 5W 10VA @230 vol t
Pul se output BS EN 62053 -31

Outputs
There are two opti cal l y i sol ated vol t f ree rel ays, kWh and kVAh on the
I C 970 meter.
Pul se durati on: Programmabl e.
Def aul t 100 ms
Pul se Val ue: Programmabl e.
Def aul t 1 kWh, 1 kVah
Rel ay contacts maxi mum swi tchi ng vol tage 230 vol t 100 Ma
Maxi mum swi tchi ng current 0. 75 Amp ( swi tchi ng power 30 va)
Communication Module
Ful l y programmabl e 485 Modbus
Def aul t.
Baud Rate: 9600
Wi re Mode: 2 WI RE
Modbus Type: RTU
Pari ty Type: EVEN
Data Format: FLOATI NG POI NT
FP. Format: HI GH WORD 1st
Performance & Data
Supplied As Standard
Function 12 - Peak maximum demand reset View only
Function 13 - C.T and N.T current transformer setting Programmable
Function 21 - Pulse value Programmable
Function 22 - Pulse Duration Programmable
Function 30 - Display contrast Programmable
Function 31 - Back light Duration Programmable
Function 50 - Connection details View only
Function 51 - Relay test mode View only
Function 52 - Binary switch positions View only
Function 60 - Minimum and maximum volts View only
Function 61 - Minimum and maximum amps View only
Function 62 - Minimum and maximum neutral amp View only
Functions
Dimension and
Terminal Arrangements
9
6

m
m
89 mm
103 mm
9
0

m
m
90 mm
Sales Leafet IC970 17. 07. 07